Abdul-Khaaliq Mohamed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdul-Khaaliq Mohamed has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Vered Aharonson
University of the Witwatersrand
2 shared publications Gabriel D. Eisenberg
1 shared publicationKyle G.H.M. Fyvie
1 shared publicationL. R. John
Deparrtment of Human Biology, University of Cape Town, Cape Town, South Africa
1 shared publication- Muhammed Aswat
School of Electrical and Information Engineering, University of Witwatersrand, Johannesburg 2050, South Africa
1 shared publication Shani Feller
University of the Witwatersrand, Private Bag 3, 2050, Johannesburg, South Africa
1 shared publication
Latest Publications
- Open Access
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 409-412
Bayesian input model selection for wrist control by a bionic hand
Dynamic causal modelling is a promising tool to quantify hand movement neural control. It portrays the temporal path of signals across a network of distinct motor control areas in the brain. Optimising the input representation for this modelling framework-including defining the input signal and its entry point into the motor-control network- could enhance its ability to explain interactions within the brain. A more precise characterisation of these inputs may also shed light on visuomotor coordination, which is linked to efficient brain-computer interface usage and bionic hand control. This study applied Bayesian selection to determine the optimal input model. Electroencephalography recordings were acquired from three participants who performed wrist extension and wrist flexion movements. Nine candidate input models were compared using the Bayesian selection's logevidence. The selection was evaluated by the spectral variance between each participant’s measured spectrograms and those predicted by the winning model. In all participants, the same input model was selected: an input signal of three gamma functions entering the left and right premotor cortices. This input model provides insights into visuomotor coordination and can improve the performance of a brain-computer interface controlling a bionic hand.
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 409-412
Open AccessBayesian input model selection for wrist control by a bionic hand
Dynamic causal modelling is a promising tool to quantify hand movement neural control. It portrays the temporal path of signals across a network of distinct motor control areas in the brain. Optimising the input representation for this modelling framework-including defining the input signal and its entry point into the motor-control network- could enhance its ability to explain interactions within the brain. A more precise characterisation of these inputs may also shed light on visuomotor coordination, which is linked to efficient brain-computer interface usage and bionic hand control. This study applied Bayesian selection to determine the optimal input model. Electroencephalography recordings were acquired from three participants who performed wrist extension and wrist flexion movements. Nine candidate input models were compared using the Bayesian selection's logevidence. The selection was evaluated by the spectral variance between each participant’s measured spectrograms and those predicted by the winning model. In all participants, the same input model was selected: an input signal of three gamma functions entering the left and right premotor cortices. This input model provides insights into visuomotor coordination and can improve the performance of a brain-computer interface controlling a bionic hand.
- Open Access
- 18 March 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (3) , 187
Single-Trial Electroencephalography Discrimination of Real, Regulated, Isometric Wrist Extension and Wrist Flexion
Improved interpretation of electroencephalography (EEG) associated with the neural control of essential hand movements, including wrist extension (WE) and wrist flexion (WF), could improve the performance of brain–computer interfaces (BCIs). These BCIs could control a prosthetic or orthotic hand to enable motor-impaired individuals to regain the performance of activities of daily living. This study investigated the interpretation of neural signal patterns associated with kinematic differences between real, regulated, isometric WE and WF movements from recorded EEG data. We used 128-channel EEG data recorded from 14 participants performing repetitions of the wrist movements, where the force, speed, and range of motion were regulated. The data were filtered into four frequency bands: delta and theta, mu and beta, low gamma, and high gamma. Within each frequency band, independent component analysis was used to isolate signals originating from seven cortical regions of interest. Features were extracted from these signals using a time–frequency algorithm and classified using Mahalanobis distance clustering. We successfully classified bilateral and unilateral WE and WF movements, with respective accuracies of 90.68% and 69.80%. The results also demonstrated that all frequency bands and regions of interest contained motor-related discriminatory information. Bilateral discrimination relied more on the mu and beta bands, while unilateral discrimination favoured the gamma bands. These results suggest that EEG-based BCIs could benefit from the extraction of features from multiple frequencies and cortical regions.
- 18 March 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (3) , 187
Open AccessSingle-Trial Electroencephalography Discrimination of Real, Regulated, Isometric Wrist Extension and Wrist Flexion
Improved interpretation of electroencephalography (EEG) associated with the neural control of essential hand movements, including wrist extension (WE) and wrist flexion (WF), could improve the performance of brain–computer interfaces (BCIs). These BCIs could control a prosthetic or orthotic hand to enable motor-impaired individuals to regain the performance of activities of daily living. This study investigated the interpretation of neural signal patterns associated with kinematic differences between real, regulated, isometric WE and WF movements from recorded EEG data. We used 128-channel EEG data recorded from 14 participants performing repetitions of the wrist movements, where the force, speed, and range of motion were regulated. The data were filtered into four frequency bands: delta and theta, mu and beta, low gamma, and high gamma. Within each frequency band, independent component analysis was used to isolate signals originating from seven cortical regions of interest. Features were extracted from these signals using a time–frequency algorithm and classified using Mahalanobis distance clustering. We successfully classified bilateral and unilateral WE and WF movements, with respective accuracies of 90.68% and 69.80%. The results also demonstrated that all frequency bands and regions of interest contained motor-related discriminatory information. Bilateral discrimination relied more on the mu and beta bands, while unilateral discrimination favoured the gamma bands. These results suggest that EEG-based BCIs could benefit from the extraction of features from multiple frequencies and cortical regions.
- Open Access
Low-Cost Dynamometer for Measuring and Regulating Wrist Extension and Flexion Motor Tasks in Electroencephalography Experiments
A brain–computer interface could control a bionic hand by interpreting electroencephalographic (EEG) signals associated with wrist extension (WE) and wrist flexion (WF) movements. Misinterpretations of the EEG may stem from variations in the force, speed and range of these movements. To address this, we designed, constructed and tested a novel dynamometer, the IsoReg, which regulates WE and WF movements during EEG recording experiments. The IsoReg restricts hand movements to isometric WE and WF, controlling their speed and range of motion. It measures movement force using a dual-load cell system that calculates the percentage of maximum voluntary contraction and displays it to help users control movement force. Linearity and measurement accuracy were tested, and the IsoReg’s performance was evaluated under typical EEG experimental conditions with 14 participants. The IsoReg demonstrated consistent linearity between applied and measured forces across the required force range, with a mean accuracy of 97% across all participants. The visual force gauge provided normalised force measurements with a mean accuracy exceeding 98.66% across all participants. All participants successfully controlled the motor tasks at the correct relative forces (with a mean accuracy of 89.90%) using the IsoReg, eliminating the impact of inherent force differences between typical WE and WF movements on the EEG analysis. The IsoReg offers a low-cost method for measuring and regulating movements in future neuromuscular studies, potentially leading to improved neural signal interpretation.
Open AccessLow-Cost Dynamometer for Measuring and Regulating Wrist Extension and Flexion Motor Tasks in Electroencephalography Experiments
A brain–computer interface could control a bionic hand by interpreting electroencephalographic (EEG) signals associated with wrist extension (WE) and wrist flexion (WF) movements. Misinterpretations of the EEG may stem from variations in the force, speed and range of these movements. To address this, we designed, constructed and tested a novel dynamometer, the IsoReg, which regulates WE and WF movements during EEG recording experiments. The IsoReg restricts hand movements to isometric WE and WF, controlling their speed and range of motion. It measures movement force using a dual-load cell system that calculates the percentage of maximum voluntary contraction and displays it to help users control movement force. Linearity and measurement accuracy were tested, and the IsoReg’s performance was evaluated under typical EEG experimental conditions with 14 participants. The IsoReg demonstrated consistent linearity between applied and measured forces across the required force range, with a mean accuracy of 97% across all participants. The visual force gauge provided normalised force measurements with a mean accuracy exceeding 98.66% across all participants. All participants successfully controlled the motor tasks at the correct relative forces (with a mean accuracy of 89.90%) using the IsoReg, eliminating the impact of inherent force differences between typical WE and WF movements on the EEG analysis. The IsoReg offers a low-cost method for measuring and regulating movements in future neuromuscular studies, potentially leading to improved neural signal interpretation.
- Open Access
- 1 January 2021
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 54 (21) , 109-114
Investigating ICA for EEG Electrode Optimization for The Differentiation Between Right-Hand and Left-Hand Movements
- 1 January 2021
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 54 (21) , 109-114
Open AccessInvestigating ICA for EEG Electrode Optimization for The Differentiation Between Right-Hand and Left-Hand Movements
- 1 December 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (2) , 151-156
Real-Time Segmentation and Feature Extraction of Electromyography: Towards Control of a Prosthetic Hand
- 1 December 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (2) , 151-156
Real-Time Segmentation and Feature Extraction of Electromyography: Towards Control of a Prosthetic Hand
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 6289-6293
Single-trial EEG discrimination between wrist and finger movement imagery and execution in a sensorimotor BCI
A Brain-computer interface (BCI) may be used to control a prosthetic or orthotic hand using neural activity from the brain. The core of this sensorimotor BCI lies in the interpretation of the neural information extracted from electroencephalogram (EEG). It is desired to improve on the interpretation of EEG to allow people with neuromuscular disorders to perform daily activities. This paper investigates the possibility of discriminating between the EEG associated with wrist and finger movements. The EEG was recorded from test subjects as they executed and imagined five essential hand movements using both hands. Independent component analysis (ICA) and time-frequency techniques were used to extract spectral features based on event-related (de)synchronisation (ERD/ERS), while the Bhattacharyya distance (BD) was used for feature reduction. Mahalanobis distance (MD) clustering and artificial neural networks (ANN) were used as classifiers and obtained average accuracies of 65 % and 71 % respectively. This shows that EEG discrimination between wrist and finger movements is possible. The research introduces a new combination of motor tasks to BCI research.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 6289-6293
Single-trial EEG discrimination between wrist and finger movement imagery and execution in a sensorimotor BCI
A Brain-computer interface (BCI) may be used to control a prosthetic or orthotic hand using neural activity from the brain. The core of this sensorimotor BCI lies in the interpretation of the neural information extracted from electroencephalogram (EEG). It is desired to improve on the interpretation of EEG to allow people with neuromuscular disorders to perform daily activities. This paper investigates the possibility of discriminating between the EEG associated with wrist and finger movements. The EEG was recorded from test subjects as they executed and imagined five essential hand movements using both hands. Independent component analysis (ICA) and time-frequency techniques were used to extract spectral features based on event-related (de)synchronisation (ERD/ERS), while the Bhattacharyya distance (BD) was used for feature reduction. Mahalanobis distance (MD) clustering and artificial neural networks (ANN) were used as classifiers and obtained average accuracies of 65 % and 71 % respectively. This shows that EEG discrimination between wrist and finger movements is possible. The research introduces a new combination of motor tasks to BCI research.