Megan Holtzman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Megan Holtzman has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Daphne I. Townsend
Department of Systems and Computer Engineering, Carleton University, Ottawa, Canada
1 shared publicationDaphne Townsend
Department of Systems and Computer Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6 Canada
1 shared publicationFrank Knoefel
Department of Systems and Computer Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6 Canada
1 shared publication- Frank Knoefel
Memory Care Research Group, Bruyère Health Research Institute, Ottawa, ON, Canada
1 shared publication - Monique Frize
Department of Systems and Computer Engineering, Carleton University, Ottawa, Canada
1 shared publication Rafik Goubran
Department of Systems and Computer Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6 Canada
1 shared publication
Latest Publications
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 381-384
Breathing sensor selection during movement
A pressure sensor array placed below a mattress can be used to estimate the breathing effort signal unobtrusively. When multiple breathing effort sensor outputs are available, there is sometimes a need to choose the sensor with the best approximation of the actual breathing effort. Previous work with pressure sensor arrays placed on top of or under mattresses used for respiration rate and breathing signal estimation have used either the amplitude or the power spectrum to choose the most representative sensor. These methods are both useful when the subject is still; however, pressure sensor signals also contain movement. We propose and test a spectral ratio method for selection in the presence of movement. The spectral ratio method is good at finding strong breathing signals and at discriminating movement signals from strong breathing signals. This method provides a mean correlation to respiration bands that is 4% higher than the next best method during small movements and 14% higher during larger movements.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 381-384
Breathing sensor selection during movement
A pressure sensor array placed below a mattress can be used to estimate the breathing effort signal unobtrusively. When multiple breathing effort sensor outputs are available, there is sometimes a need to choose the sensor with the best approximation of the actual breathing effort. Previous work with pressure sensor arrays placed on top of or under mattresses used for respiration rate and breathing signal estimation have used either the amplitude or the power spectrum to choose the most representative sensor. These methods are both useful when the subject is still; however, pressure sensor signals also contain movement. We propose and test a spectral ratio method for selection in the presence of movement. The spectral ratio method is good at finding strong breathing signals and at discriminating movement signals from strong breathing signals. This method provides a mean correlation to respiration bands that is 4% higher than the next best method during small movements and 14% higher during larger movements.
- 10 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 60 (5) , 1751-1760
Measurement of Torso Movement With Delay Mapping Using an Unobtrusive Pressure-Sensor Array
The use of unobtrusive sensors for physiological monitoring is growing in popularity. With advantages such as their noncontact nature plus limited physical and cognitive load on the user, unobtrusive sensors will likely increase acceptance and usefulness in biomedical monitoring. Biomedical applications for unobtrusive pressure sensors include the analysis of bed transfer sequences and the extraction of breathing rate during long-term trend analysis and health monitoring. This paper proposes an algorithm to measure torso movement using an unobtrusive pressure-sensor array. This work makes use of the information captured by measuring the respiratory-signal delay between sensors in the array. The novel contributions are using cross-correlation to realign polarity-adjusted signals from a pressure-sensor array and to create a map of delays across the torso. Not only is the advantage in adjusting the polarity of inverted signal clearly demonstrated, but in many cases, the realignment according to the delay increases the signal amplitude and further improves the signal-to-noise ratio in many cases. The map of delays between the pressure sensors' signals reveals important information about movement timing in the torso while breathing.
- 10 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 60 (5) , 1751-1760
Measurement of Torso Movement With Delay Mapping Using an Unobtrusive Pressure-Sensor Array
The use of unobtrusive sensors for physiological monitoring is growing in popularity. With advantages such as their noncontact nature plus limited physical and cognitive load on the user, unobtrusive sensors will likely increase acceptance and usefulness in biomedical monitoring. Biomedical applications for unobtrusive pressure sensors include the analysis of bed transfer sequences and the extraction of breathing rate during long-term trend analysis and health monitoring. This paper proposes an algorithm to measure torso movement using an unobtrusive pressure-sensor array. This work makes use of the information captured by measuring the respiratory-signal delay between sensors in the array. The novel contributions are using cross-correlation to realign polarity-adjusted signals from a pressure-sensor array and to create a map of delays across the torso. Not only is the advantage in adjusting the polarity of inverted signal clearly demonstrated, but in many cases, the realignment according to the delay increases the signal amplitude and further improves the signal-to-noise ratio in many cases. The map of delays between the pressure sensors' signals reveals important information about movement timing in the torso while breathing.