Paul R. Roberts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paul R. Roberts has a total of 275 co-authors. Here are the top co-authors by number of shared publications:
- John Mark Morgan
University of Southampton, Southampton, United Kingdom
7 shared publications - David G. Wilson
Department of Cardiology, Worcester Royal Hospital, Worcester WR5 1DD, UK
4 shared publications - Paul A. Scott
Wessex Cardiothoracic Unit, Southampton University Hospitals NHS Trust, Tremona Road, Southampton SO16 6YD, UK
3 shared publications A. D'Avila
2 shared publicationsA.M. Yue
2 shared publications- John M. Morgan
Cardiology & Electrophysiology, University Hospital Southampton, Southampton, UK
2 shared publications
Latest Publications
- Open Access
- 14 October 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002574
Predictors of death without prior appropriate therapy in ICD recipients: the comorbidities, frailty and functional status (COMFFORT study)
Objective Most patients who have an implantable cardioverter-defibrillator (ICD) implant do not receive life-prolonging therapy from it. Little research has been undertaken to determine which patients benefit the least from ICD therapy. As patients age and accumulate comorbidities, the risk of death increases and the benefit of ICDs diminishes. We sought to evaluate the impact of comorbidity, frailty, functional status on death with no prior appropriate ICD therapy. Methods A prospective, multicentre, observational study involving 12 English hospitals was undertaken. Patients were eligible for inclusion for the study if they were scheduled to have a de novo, upgrade to or replacement of a transvenous or subcutaneous ICD or cardiac resynchronisation therapy device and defibrillator (CRT-D). Baseline characteristics were collected. Participants were asked to complete a frailty assessment (Fried score) and a functional status questionnaire (EuroQol 5-Dimension 5-Level (EQ-5D-5L)). The Charlson Comorbidity Index was calculated. Patients were prospectively followed up for 2.5 years. The primary outcome was death with no prior appropriate therapy. Results In total, 675 patients were enrolled, mean age 65.7 (IQR 65–75) years. A total of 63 patients (9.5%) died during follow-up, 58 without receiving appropriate ICD therapy. Frailty was present in 86/675 (12.7%) and severe comorbidity in 69/675 (10.2%). Multivariate predictors of death with no appropriate therapy were identified and a risk score comprising frailty, comorbidity, increasing age, estimated glomerular filtration rate and EQ-5D-5L was developed. Conclusion Comorbidities, frailty and the EQ-5D-5L score are powerful, independent predictors of death with no prior appropriate therapy in ICD/CRT-D recipients.
- 14 October 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002574
Open AccessPredictors of death without prior appropriate therapy in ICD recipients: the comorbidities, frailty and functional status (COMFFORT study)
Objective Most patients who have an implantable cardioverter-defibrillator (ICD) implant do not receive life-prolonging therapy from it. Little research has been undertaken to determine which patients benefit the least from ICD therapy. As patients age and accumulate comorbidities, the risk of death increases and the benefit of ICDs diminishes. We sought to evaluate the impact of comorbidity, frailty, functional status on death with no prior appropriate ICD therapy. Methods A prospective, multicentre, observational study involving 12 English hospitals was undertaken. Patients were eligible for inclusion for the study if they were scheduled to have a de novo, upgrade to or replacement of a transvenous or subcutaneous ICD or cardiac resynchronisation therapy device and defibrillator (CRT-D). Baseline characteristics were collected. Participants were asked to complete a frailty assessment (Fried score) and a functional status questionnaire (EuroQol 5-Dimension 5-Level (EQ-5D-5L)). The Charlson Comorbidity Index was calculated. Patients were prospectively followed up for 2.5 years. The primary outcome was death with no prior appropriate therapy. Results In total, 675 patients were enrolled, mean age 65.7 (IQR 65–75) years. A total of 63 patients (9.5%) died during follow-up, 58 without receiving appropriate ICD therapy. Frailty was present in 86/675 (12.7%) and severe comorbidity in 69/675 (10.2%). Multivariate predictors of death with no appropriate therapy were identified and a risk score comprising frailty, comorbidity, increasing age, estimated glomerular filtration rate and EQ-5D-5L was developed. Conclusion Comorbidities, frailty and the EQ-5D-5L score are powerful, independent predictors of death with no prior appropriate therapy in ICD/CRT-D recipients.
- 5 December 2018
- Published by Taylor & Francis in Future Cardiology
- Vol. 15 (1) , 9-15
Design and Evaluation of the Micra Transcatheter Pacing System for Bradyarrhythmia Management
Permanent cardiac pacemakers have traditionally comprised a surgically implanted subcutaneous pulse generator affixed to at least one transvenous pacing lead. Despite technological advances, implant-related complications and transvenous-lead failure rates have remained high. The Micra Transcatheter Pacing System is a miniaturized single chamber pacemaker that is implanted directly into the right ventricle, eliminating the subcutaneous pocket and creating a leadless pacemaker system. Registry data show an extremely high implant success rate, significantly lower major complication rates than transvenous pacemakers, stable pacing parameters and reliable battery performance. In this review we summarize the available clinical literature and highlight the promising efficacy and safety of the Micra Transcatheter Pacing System.
- 5 December 2018
- Published by Taylor & Francis in Future Cardiology
- Vol. 15 (1) , 9-15
Design and Evaluation of the Micra Transcatheter Pacing System for Bradyarrhythmia Management
Permanent cardiac pacemakers have traditionally comprised a surgically implanted subcutaneous pulse generator affixed to at least one transvenous pacing lead. Despite technological advances, implant-related complications and transvenous-lead failure rates have remained high. The Micra Transcatheter Pacing System is a miniaturized single chamber pacemaker that is implanted directly into the right ventricle, eliminating the subcutaneous pocket and creating a leadless pacemaker system. Registry data show an extremely high implant success rate, significantly lower major complication rates than transvenous pacemakers, stable pacing parameters and reliable battery performance. In this review we summarize the available clinical literature and highlight the promising efficacy and safety of the Micra Transcatheter Pacing System.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i175-i176
P911Universal S-ICD eligibility: eliminating the need for pre-implant screening using mathematical vector rotation and a gradient filter
Funding Acknowledgements: Unrestricted fellowship grant from Boston Scientific
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i175-i176
P911Universal S-ICD eligibility: eliminating the need for pre-implant screening using mathematical vector rotation and a gradient filter
Funding Acknowledgements: Unrestricted fellowship grant from Boston Scientific
- Open Access
- 1 September 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (9) , 1375-1379
A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry
- 1 September 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (9) , 1375-1379
Open AccessA leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry
- 1 April 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 209, 96-97
“Leadless” pacing of the left ventricle in adult congenital heart disease
- 1 April 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 209, 96-97
“Leadless” pacing of the left ventricle in adult congenital heart disease
- 14 October 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 203, 407-408
Leadless pacing: The old with the new
- 14 October 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 203, 407-408
Leadless pacing: The old with the new
- 8 January 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (4) , 511-513
Strategies to reduce infections during the cardiac implantable electronic device implant: a time to name and shame
- 8 January 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (4) , 511-513
Strategies to reduce infections during the cardiac implantable electronic device implant: a time to name and shame
- Open Access
- 1 October 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (suppl_4) , iv18-iv21
MODERATED POSTERS, SESSION 2
ICD therapy effectively prevents sudden cardiac death (SCD) in appropriately selected patients. However identifying patients with greatest potential to benefit from ICD therapy remains a challenge. This is in part due to the fact that many current risk stratification tools are not specific for mode of death. The extent of left ventricular (LV) scar, characterized by late gadolinium enhancement cardiac MRI (LGE-CMR), has been shown to predict the occurrence of ventricular arrhythmias in ICD recipients independently of LVEF and has been proposed as a novel test to guide patient selection for ICD therapy. However the specificity of LGE-CMR scar quantification for SCD versus non-SCD is unclear.
- 1 October 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (suppl_4) , iv18-iv21
Open AccessMODERATED POSTERS, SESSION 2
ICD therapy effectively prevents sudden cardiac death (SCD) in appropriately selected patients. However identifying patients with greatest potential to benefit from ICD therapy remains a challenge. This is in part due to the fact that many current risk stratification tools are not specific for mode of death. The extent of left ventricular (LV) scar, characterized by late gadolinium enhancement cardiac MRI (LGE-CMR), has been shown to predict the occurrence of ventricular arrhythmias in ICD recipients independently of LVEF and has been proposed as a novel test to guide patient selection for ICD therapy. However the specificity of LGE-CMR scar quantification for SCD versus non-SCD is unclear.
- Open Access
- 1 June 2009
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (Supplement)
Poster Session 2: Pacing leads
Background: A desirable left ventricular (LV) pacing site is thought to enhance the likelihood of benefit with cardiac resynchronization therapy (CRT). The Model 4196 LV lead is a small (4Fr), dual electrode lead. We sought to assess the association of pacing from a desirable (non-anterior) site with clinical outcome.
- 1 June 2009
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (Supplement)
Open AccessPoster Session 2: Pacing leads
Background: A desirable left ventricular (LV) pacing site is thought to enhance the likelihood of benefit with cardiac resynchronization therapy (CRT). The Model 4196 LV lead is a small (4Fr), dual electrode lead. We sought to assess the association of pacing from a desirable (non-anterior) site with clinical outcome.
- Open Access
- 1 June 2009
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (Supplement)
Poster Session 2: CRT: techniques and imaging
Purpose: A large number of groups have investigated the individual haemodynamic benefits of atrioventricular (AV) and ventricular - ventricular (VV) optimisation, and a few groups have looked at the overall benefit of the optimisation process. However, the relative benefits of AV and VV optimisation have been poorly studied. This study aims to compare the effects of AV and VV optimisation using echocardiographic Doppler measures, thoracic impedance measures of stroke volume (SV) and blood pressure (BP) assessment.
- 1 June 2009
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (Supplement)
Open AccessPoster Session 2: CRT: techniques and imaging
Purpose: A large number of groups have investigated the individual haemodynamic benefits of atrioventricular (AV) and ventricular - ventricular (VV) optimisation, and a few groups have looked at the overall benefit of the optimisation process. However, the relative benefits of AV and VV optimisation have been poorly studied. This study aims to compare the effects of AV and VV optimisation using echocardiographic Doppler measures, thoracic impedance measures of stroke volume (SV) and blood pressure (BP) assessment.