Michael Gould
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Gould has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Kai-Mei C. Fu
University of Washington
3 shared publications Nicole Thomas
Department of Electrical Engineering, University of Washington, 185 Stevens Way, Seattle, Washington 98195-2500, USA
3 shared publicationsFariba Hatami
Department of Physics, Humboldt-Universitat zu Berlin, 12489 Berlin, Germany
2 shared publications- Emma R. Schmidgall
Univ. of Washington (United States)
1 shared publication Hamed Arami
Dept. of Material Science and Engineering Univ. of Washington Box 352120 98195-2120 Seattle WA USA
1 shared publication- Hamed Arami
Materials Science and Engineering, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
1 shared publication
Latest Publications
- 1 January 2018
- Published by Optica Publishing Group
- p. FM1H.2
Frequency Control of Single Quantum Emitters in Integrated Photonic Circuits
We demonstrate a potential integrated-circuit architecture for quantum computation with nitrogen vacancy centers in diamond. The combination of photonic device integration and eletrodes enables both high emission rates and tuning of the emission frequency.
- 1 January 2018
- Published by Optica Publishing Group
- p. FM1H.2
Frequency Control of Single Quantum Emitters in Integrated Photonic Circuits
We demonstrate a potential integrated-circuit architecture for quantum computation with nitrogen vacancy centers in diamond. The combination of photonic device integration and eletrodes enables both high emission rates and tuning of the emission frequency.
- Open Access
- 15 January 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 33 (3) , B35-B42
Large-scale GaP-on-diamond integrated photonics platform for NV center-based quantum information
We present chip-scale transmission measurements for three key components of a gallium-phosphide (GaP)-on-diamond integrated photonics platform: waveguide-coupled disk resonators, directional couplers, and grating couplers. We also present proof-of-principle measurements demonstrating nitrogen-vacancy (NV) center-emission coupled into selected devices. The demonstrated device performance, uniformity, and yield place the platform in a strong position to realize measurement-based quantum information protocols utilizing the NV center in diamond.
- 15 January 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 33 (3) , B35-B42
Open AccessLarge-scale GaP-on-diamond integrated photonics platform for NV center-based quantum information
We present chip-scale transmission measurements for three key components of a gallium-phosphide (GaP)-on-diamond integrated photonics platform: waveguide-coupled disk resonators, directional couplers, and grating couplers. We also present proof-of-principle measurements demonstrating nitrogen-vacancy (NV) center-emission coupled into selected devices. The demonstrated device performance, uniformity, and yield place the platform in a strong position to realize measurement-based quantum information protocols utilizing the NV center in diamond.
- Open Access
- 18 August 2014
- Published by AIP Publishing in Applied Physics Letters
- Vol. 105 (7) , 072406
Room-temperature detection of a single 19 nm super-paramagnetic nanoparticle with an imaging magnetometer
We demonstrate room temperature detection of isolated single 19 nm super-paramagnetic nanoparticles (SPNs) with a wide-field optical microscope platform suitable for biological integration. The particles are made of magnetite (Fe3O4) and are thus non-toxic and biocompatible. Detection is accomplished via optically detected magnetic resonance imaging using nitrogen-vacancy defect centers in diamond, resulting in a DC magnetic field detection limit of 2.4 μT. This marks a large step forward in the detection of SPNs, and we expect that it will allow for the development of magnetic-field-based biosensors capable of detecting a single molecular binding event.
- 18 August 2014
- Published by AIP Publishing in Applied Physics Letters
- Vol. 105 (7) , 072406
Open AccessRoom-temperature detection of a single 19 nm super-paramagnetic nanoparticle with an imaging magnetometer
We demonstrate room temperature detection of isolated single 19 nm super-paramagnetic nanoparticles (SPNs) with a wide-field optical microscope platform suitable for biological integration. The particles are made of magnetite (Fe3O4) and are thus non-toxic and biocompatible. Detection is accomplished via optically detected magnetic resonance imaging using nitrogen-vacancy defect centers in diamond, resulting in a DC magnetic field detection limit of 2.4 μT. This marks a large step forward in the detection of SPNs, and we expect that it will allow for the development of magnetic-field-based biosensors capable of detecting a single molecular binding event.
- Open Access
Room-temperature detection of single 20 nm super-paramagnetic nanoparticles with an imaging magnetometer
We demonstrate room temperature detection of single 20 nm super-paramagnetic nanoparticles (SPNs) with a wide-field optical microscope platform suitable for biological integration. The particles are made of magnetite (Fe3O4) and are thus non-toxic and biocompatible. Detection is accomplished via optically detected magnetic resonance imaging using nitrogen-vacancy defect centers in diamond, resulting in a DC magnetic field detection limit of 2.3 {\mu}T. This marks a large step forward in the detection of SPNs, and we expect that it will allow for the development of magnetic-field-based biosensors capable of detecting a single molecular binding event.
Open AccessRoom-temperature detection of single 20 nm super-paramagnetic nanoparticles with an imaging magnetometer
We demonstrate room temperature detection of single 20 nm super-paramagnetic nanoparticles (SPNs) with a wide-field optical microscope platform suitable for biological integration. The particles are made of magnetite (Fe3O4) and are thus non-toxic and biocompatible. Detection is accomplished via optically detected magnetic resonance imaging using nitrogen-vacancy defect centers in diamond, resulting in a DC magnetic field detection limit of 2.3 {\mu}T. This marks a large step forward in the detection of SPNs, and we expect that it will allow for the development of magnetic-field-based biosensors capable of detecting a single molecular binding event.