Litai Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Litai Ma has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Yi Yang
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
5 shared publicationsHao Liu
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, China
4 shared publicationsQuan Gong
4 shared publicationsHao Liu
3 shared publications- Jiancheng Zeng
Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, China
3 shared publications Kerui Zhang
Department of Orthopedics, Orthopedic Research Institute, West China Hospital Sichuan University Chengdu China
3 shared publications
Latest Publications
- Open Access
- 20 June 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1532207
A finite element study for tibial fractures: analyze the biomechanical condition of the tibial fracture area to provide guidance for subsequent treatment
Introduction: Distal tibial fractures are common fracture sites and usually require surgical treatment to achieve anatomical reduction. Intramedullary nails (IMN) are widely used in orthopedics for stabilizing fractured bones and treating limb deformities. The process of postoperative bone healing is of great significance for patient rehabilitation and can guide subsequent treatment methods. However, the current radiographic techniques used to determine the degree of fusion, such as X-ray, need to be improved in accuracy and have some radiation effects. Several studies suggested that the mechanical load on the fracture area could reflect the bone healing process and evaluated the stability of fracture area. The aim of this study is to investigate the biomechanical changes in the fracture area during bone healing and IMN, and to prepare for the subsequent placement of intelligent stress and displacement sensors based on the changes in stress and displacement, in order to provide guidance for the treatment and rehabilitation of postoperative fractures.Methods: Finite element (FE) models representing different healing stages of tibial fractures were developed. All conditions were applied to simulate the stress and strain of the IMN fixation system under normal tibial stress.Results: The stress at the fracture area on the IMN gradually decreases, while the stress on the callus gradually increases until reaching a stable state at the 12th week after surgery. And the deformation value and the displacement value of the callus decrease and stabilize over time. Based on the changes in stress at the fracture area of the IMN and the displacement value of the callus, we can place a stress sensor at the fracture area of the IMN and a displacement sensor at the callus area.Conclusion: This study utilized FE analysis to evaluate stress, deformation and displacement between the IMN and bone during the healing process of tibial fractures in four stages. By combining these aspects, the degree of bone healing can be assessed. This research enables orthopedic doctors to monitor the progression of fracture healing without relying solely on imaging examinations. Furthermore, it aids in guiding patients to undergo appropriate rehabilitation training for better recovery.
- 20 June 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1532207
Open AccessA finite element study for tibial fractures: analyze the biomechanical condition of the tibial fracture area to provide guidance for subsequent treatment
Introduction: Distal tibial fractures are common fracture sites and usually require surgical treatment to achieve anatomical reduction. Intramedullary nails (IMN) are widely used in orthopedics for stabilizing fractured bones and treating limb deformities. The process of postoperative bone healing is of great significance for patient rehabilitation and can guide subsequent treatment methods. However, the current radiographic techniques used to determine the degree of fusion, such as X-ray, need to be improved in accuracy and have some radiation effects. Several studies suggested that the mechanical load on the fracture area could reflect the bone healing process and evaluated the stability of fracture area. The aim of this study is to investigate the biomechanical changes in the fracture area during bone healing and IMN, and to prepare for the subsequent placement of intelligent stress and displacement sensors based on the changes in stress and displacement, in order to provide guidance for the treatment and rehabilitation of postoperative fractures.Methods: Finite element (FE) models representing different healing stages of tibial fractures were developed. All conditions were applied to simulate the stress and strain of the IMN fixation system under normal tibial stress.Results: The stress at the fracture area on the IMN gradually decreases, while the stress on the callus gradually increases until reaching a stable state at the 12th week after surgery. And the deformation value and the displacement value of the callus decrease and stabilize over time. Based on the changes in stress at the fracture area of the IMN and the displacement value of the callus, we can place a stress sensor at the fracture area of the IMN and a displacement sensor at the callus area.Conclusion: This study utilized FE analysis to evaluate stress, deformation and displacement between the IMN and bone during the healing process of tibial fractures in four stages. By combining these aspects, the degree of bone healing can be assessed. This research enables orthopedic doctors to monitor the progression of fracture healing without relying solely on imaging examinations. Furthermore, it aids in guiding patients to undergo appropriate rehabilitation training for better recovery.
- Open Access
- 2 April 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (5) , 1464-1477
Comparative Analysis of Three Vertebral Screw Placement Directions in Anterior Thoracolumbar Fracture Surgery: A Finite Element Study
Background: Thoracolumbar fractures, especially burst fractures, are common severe spinal injuries requiring surgery. The main goals are to restore spinal stability and normal curvature, relieve nerve compression, and prevent further neurological damage. Minimally invasive techniques are increasingly used in spinal surgery. This study aims to use finite element analysis to compare two new thoracolumbar anterior fixation systems: Hybrid cross‐thoracolumbar fixation system and new hybrid cross‐thoracolumbar fixation system (HXTL and NHXTL) with Medtronic's ANTERIOR system, providing a theoretical reference for surgeries.Method: A finite element model of the T12–L2 vertebrae of a 27‐year‐old healthy male was built based on CT images. The model was processed, optimized, meshed, and analyzed using software. In vitro biomechanical tests were compared with the finite element model results to verify the model's validity. A 500 N compressive load and a 10 N m bending moment were applied to the upper surface of T12. The stress and displacement of the vertebral body and the stress state of the support body of the two models under various conditions like forward flexion and backward extension were observed and analyzed.Results: The study compared the biomechanical performance of the HXTL, NHXTL, and ANTERIOR systems under six physiological conditions. The vertebral body displacement of the three systems was maximum under forward flexion. During right flexion, the HXTL displacement was significantly greater than that of the ANTERIOR and NHXTL systems, while during extension, the HXTL and NHXTL displacements were significantly less than those of the ANTERIOR system. Under other motion conditions, the displacements were relatively small. In terms of vertebral body stress, the ANTERIOR model had the maximum stress during left flexion, significantly greater than that of the other two. In terms of titanium mesh stress, the HXTL system had significantly higher stress during extension and left rotation compared to the other two systems. In terms of nail–rod stress, the ANTERIOR system had higher stress in all directions than the HXTL and NHXTL systems.Conclusion: Compared with the ANTERIOR system, the HXTL system reduces the surgical incision through oblique nail placement, can reduce the risk of nail–rod failure, and increase the stability of the titanium mesh between vertebral bodies, but it also brings a higher risk of subsidence. The NHXTL model not only reduces the surgical incision and the risk of accidental injury to contralateral blood vessels but also reduces the risk of nail–rod failure and does not increase the risk of titanium mesh subsidence. It is a more optimized choice.
- 2 April 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (5) , 1464-1477
Open AccessComparative Analysis of Three Vertebral Screw Placement Directions in Anterior Thoracolumbar Fracture Surgery: A Finite Element Study
Background: Thoracolumbar fractures, especially burst fractures, are common severe spinal injuries requiring surgery. The main goals are to restore spinal stability and normal curvature, relieve nerve compression, and prevent further neurological damage. Minimally invasive techniques are increasingly used in spinal surgery. This study aims to use finite element analysis to compare two new thoracolumbar anterior fixation systems: Hybrid cross‐thoracolumbar fixation system and new hybrid cross‐thoracolumbar fixation system (HXTL and NHXTL) with Medtronic's ANTERIOR system, providing a theoretical reference for surgeries.Method: A finite element model of the T12–L2 vertebrae of a 27‐year‐old healthy male was built based on CT images. The model was processed, optimized, meshed, and analyzed using software. In vitro biomechanical tests were compared with the finite element model results to verify the model's validity. A 500 N compressive load and a 10 N m bending moment were applied to the upper surface of T12. The stress and displacement of the vertebral body and the stress state of the support body of the two models under various conditions like forward flexion and backward extension were observed and analyzed.Results: The study compared the biomechanical performance of the HXTL, NHXTL, and ANTERIOR systems under six physiological conditions. The vertebral body displacement of the three systems was maximum under forward flexion. During right flexion, the HXTL displacement was significantly greater than that of the ANTERIOR and NHXTL systems, while during extension, the HXTL and NHXTL displacements were significantly less than those of the ANTERIOR system. Under other motion conditions, the displacements were relatively small. In terms of vertebral body stress, the ANTERIOR model had the maximum stress during left flexion, significantly greater than that of the other two. In terms of titanium mesh stress, the HXTL system had significantly higher stress during extension and left rotation compared to the other two systems. In terms of nail–rod stress, the ANTERIOR system had higher stress in all directions than the HXTL and NHXTL systems.Conclusion: Compared with the ANTERIOR system, the HXTL system reduces the surgical incision through oblique nail placement, can reduce the risk of nail–rod failure, and increase the stability of the titanium mesh between vertebral bodies, but it also brings a higher risk of subsidence. The NHXTL model not only reduces the surgical incision and the risk of accidental injury to contralateral blood vessels but also reduces the risk of nail–rod failure and does not increase the risk of titanium mesh subsidence. It is a more optimized choice.
- Open Access
- 2 September 2024
- Published by Wiley in Orthopaedic Surgery
- Vol. 16 (11) , 2821-2833
How Does the Stress in the Fixation Device Change during Different Stages of Bone Healing in the Treatment of Fractures? A Finite Element Study of External Fixation for Tibial Fractures
Background: Although the specific relationship between the stress changes in the external fixator during tibial fracture treatment and the bone healing process remains unclear, it is believed that stress variations in the external fixator scaffold can, to a certain extent, reflect the progress of tibial healing.Objective: This study aims to propose a non‐invasive method for assessing the degree of fracture healing by monitoring the changes in stress transmission, the locations of stress‐sensitive points, and displacement in the external fixator‐tibia system during the healing process of tibial fractures.Methods: In this study, finite element models of tibial fractures at various healing stages were developed. Physiological conditions, including axial, torsional, and bending loads on the tibia, were simulated to evaluate stress and strain within the external scaffold‐tibia system under normal physiological loading conditions.Results: The results indicate variations in the stress distribution between the external fixator and the tibia during different stages of healing. In the early phase of fracture healing, the external fixator plays a crucial role as the primary load‐bearing unit under all three loading conditions. As the fracture healing progresses, the stress on the tibia gradually increases, concentrating on the medial part of the tibia under axial and torsional loading, and at the upper and lower ends, as well as the central part of the anterior and posterior tibia during bending loading. The stress at the callus gradually increases, while micro‐movements decrease. The stress within the external bracket gradually decreases, with a tendency for the connecting rod to transfer stress towards the screws. Throughout the fracture healing process, the location of maximum stress in the external fixator remains unchanged. Under axial and torsional loading, the maximum stress is located at the intersection of the lowest screw and the bone cortex, while under bending loading, it is at the intersection of the second screw and the connecting rod.Conclusion: During the bone healing process, stress is transferred between the external fixation frame and the bone. As bone healing advances, the stress on the connecting rods and screws of the external fixation frame decreases, and the amplitude of stress changes diminishes. When complete and robust fusion is achieved, stress variations stabilize, and the location of maximum stress on the external fixation frame remains unchanged. The intersections of the lowest screw and the bone cortex, as well as the second screw and the connecting rod, can serve as sensitive points for monitoring the degree of bone healing.
- 2 September 2024
- Published by Wiley in Orthopaedic Surgery
- Vol. 16 (11) , 2821-2833
Open AccessHow Does the Stress in the Fixation Device Change during Different Stages of Bone Healing in the Treatment of Fractures? A Finite Element Study of External Fixation for Tibial Fractures
Background: Although the specific relationship between the stress changes in the external fixator during tibial fracture treatment and the bone healing process remains unclear, it is believed that stress variations in the external fixator scaffold can, to a certain extent, reflect the progress of tibial healing.Objective: This study aims to propose a non‐invasive method for assessing the degree of fracture healing by monitoring the changes in stress transmission, the locations of stress‐sensitive points, and displacement in the external fixator‐tibia system during the healing process of tibial fractures.Methods: In this study, finite element models of tibial fractures at various healing stages were developed. Physiological conditions, including axial, torsional, and bending loads on the tibia, were simulated to evaluate stress and strain within the external scaffold‐tibia system under normal physiological loading conditions.Results: The results indicate variations in the stress distribution between the external fixator and the tibia during different stages of healing. In the early phase of fracture healing, the external fixator plays a crucial role as the primary load‐bearing unit under all three loading conditions. As the fracture healing progresses, the stress on the tibia gradually increases, concentrating on the medial part of the tibia under axial and torsional loading, and at the upper and lower ends, as well as the central part of the anterior and posterior tibia during bending loading. The stress at the callus gradually increases, while micro‐movements decrease. The stress within the external bracket gradually decreases, with a tendency for the connecting rod to transfer stress towards the screws. Throughout the fracture healing process, the location of maximum stress in the external fixator remains unchanged. Under axial and torsional loading, the maximum stress is located at the intersection of the lowest screw and the bone cortex, while under bending loading, it is at the intersection of the second screw and the connecting rod.Conclusion: During the bone healing process, stress is transferred between the external fixation frame and the bone. As bone healing advances, the stress on the connecting rods and screws of the external fixation frame decreases, and the amplitude of stress changes diminishes. When complete and robust fusion is achieved, stress variations stabilize, and the location of maximum stress on the external fixation frame remains unchanged. The intersections of the lowest screw and the bone cortex, as well as the second screw and the connecting rod, can serve as sensitive points for monitoring the degree of bone healing.
- Open Access
- 3 January 2024
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 14, 1281506
MRI radiomics-based decision support tool for a personalized classification of cervical disc degeneration: a two-center study
Objectives: To develop and validate an MRI radiomics-based decision support tool for the automated grading of cervical disc degeneration.Methods: The retrospective study included 2,610 cervical disc samples of 435 patients from two hospitals. The cervical magnetic resonance imaging (MRI) analysis of patients confirmed cervical disc degeneration grades using the Pfirrmann grading system. A training set (1,830 samples of 305 patients) and an independent test set (780 samples of 130 patients) were divided for the construction and validation of the machine learning model, respectively. We provided a fine-tuned MedSAM model for automated cervical disc segmentation. Then, we extracted 924 radiomic features from each segmented disc in T1 and T2 MRI modalities. All features were processed and selected using minimum redundancy maximum relevance (mRMR) and multiple machine learning algorithms. Meanwhile, the radiomics models of various machine learning algorithms and MRI images were constructed and compared. Finally, the combined radiomics model was constructed in the training set and validated in the test set. Radiomic feature mapping was provided for auxiliary diagnosis.Results: Of the 2,610 cervical disc samples, 794 (30.4%) were classified as low grade and 1,816 (69.6%) were classified as high grade. The fine-tuned MedSAM model achieved good segmentation performance, with the mean Dice coefficient of 0.93. Higher-order texture features contributed to the dominant force in the diagnostic task (80%). Among various machine learning models, random forest performed better than the other algorithms (p < 0.01), and the T2 MRI radiomics model showed better results than T1 MRI in the diagnostic performance (p < 0.05). The final combined radiomics model had an area under the receiver operating characteristic curve (AUC) of 0.95, an accuracy of 89.51%, a precision of 87.07%, a recall of 98.83%, and an F1 score of 0.93 in the test set, which were all better than those of other models (p < 0.05).Conclusion: The radiomics-based decision support tool using T1 and T2 MRI modalities can be used for cervical disc degeneration grading, facilitating individualized management.
- 3 January 2024
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 14, 1281506
Open AccessMRI radiomics-based decision support tool for a personalized classification of cervical disc degeneration: a two-center study
Objectives: To develop and validate an MRI radiomics-based decision support tool for the automated grading of cervical disc degeneration.Methods: The retrospective study included 2,610 cervical disc samples of 435 patients from two hospitals. The cervical magnetic resonance imaging (MRI) analysis of patients confirmed cervical disc degeneration grades using the Pfirrmann grading system. A training set (1,830 samples of 305 patients) and an independent test set (780 samples of 130 patients) were divided for the construction and validation of the machine learning model, respectively. We provided a fine-tuned MedSAM model for automated cervical disc segmentation. Then, we extracted 924 radiomic features from each segmented disc in T1 and T2 MRI modalities. All features were processed and selected using minimum redundancy maximum relevance (mRMR) and multiple machine learning algorithms. Meanwhile, the radiomics models of various machine learning algorithms and MRI images were constructed and compared. Finally, the combined radiomics model was constructed in the training set and validated in the test set. Radiomic feature mapping was provided for auxiliary diagnosis.Results: Of the 2,610 cervical disc samples, 794 (30.4%) were classified as low grade and 1,816 (69.6%) were classified as high grade. The fine-tuned MedSAM model achieved good segmentation performance, with the mean Dice coefficient of 0.93. Higher-order texture features contributed to the dominant force in the diagnostic task (80%). Among various machine learning models, random forest performed better than the other algorithms (p < 0.01), and the T2 MRI radiomics model showed better results than T1 MRI in the diagnostic performance (p < 0.05). The final combined radiomics model had an area under the receiver operating characteristic curve (AUC) of 0.95, an accuracy of 89.51%, a precision of 87.07%, a recall of 98.83%, and an F1 score of 0.93 in the test set, which were all better than those of other models (p < 0.05).Conclusion: The radiomics-based decision support tool using T1 and T2 MRI modalities can be used for cervical disc degeneration grading, facilitating individualized management.
- 1 March 2016
- Vol. 30 (3) , 328-35
[PRELIMINARY EFFECTIVENESS OF POLYAMINOACID/NANO-HYDROXYAPATITE/CALCIUM SULFATE CAGE IN LUMBAR FUSION SURGERY].
To discuss the early effectiveness of polyaminoacid/nano-hydroxyapatite/calcium sulfate (PAA/HA/CS) Cage (PHC Cage) in lumbar fusion surgery. Thirty cases undergoing lumbar fusion of single segment between March and September 2014 were enrolled in this study. The patients were randomly divided into the trial group (n = 20) and the control group (n = 10). The PHC Cage was implanted in the trial group, while the polyetheretherketone (PEEK) Cage was implanted in the control group. The patients of 2 groups mainly presented lumbocrural pain and lower limb radiation pain or numbness. There was no significant difference in gender, age, type, affected segment, disease duration, preoperative intervertebral height, the lordosis angle of fusion segments, and the Oswestry Disability Index (ODI) between 2 groups (P > 0.05). Lateral lumbar X-ray films and three dimensional CT were taken preoperatively and at 1 week and 3, 6, and 12 months postoperatively. The intervertebral height and the lordosis angle of fusion segments at 1 week and 3, 6, and 12 months after operation and ODI at 3, 6, and 12 months after operation were measured; and the bone graft fusion rate was evaluated according to Brantigan criteria. There was no significant difference in operation time, intraoperative blood loss, and the amount of autologous blood transfusion between 2 groups (P > 0.05). Healing by first intention as obtained in 30 cses. All patients were followd up 12 months. The intervertebral height of fusion segments, the lordosis angle of fusion segments, and ODI at each time point after operation were significantly improved when compared with preoperative ones (P < 0.05). The ODI showed significant difference between 3 months and 6, 12 months (P < 0.05), but there was no significant difference between the other time points after operation (P > 0.05). There was no significant difference in the intervertebral height and the lordosis angle of fusion segments between groups at different time points (P > 0.05). There was no significant difference in the above indexes between the trial group and the control group at each time point (P > 0.05). At last follow-up, 5 cases were rated as Brantigan grade E, 13 cases as grade D, and 2 cases as grade C in the trial group; 4 cases were rated grade E, 5 cases as grade D, and 1 case as grade C in the control group. The bone fusion rate was 90% in 2 groups. The PHC Cage can effectively restore and maintain the disc height of fusion segment, normal sequence and biomechanical stability of the lumbar spine. The PHC Cage is similar to the PEEK Cage and has good clinical outcome in short-term follow-up.
- 1 March 2016
- Vol. 30 (3) , 328-35
[PRELIMINARY EFFECTIVENESS OF POLYAMINOACID/NANO-HYDROXYAPATITE/CALCIUM SULFATE CAGE IN LUMBAR FUSION SURGERY].
To discuss the early effectiveness of polyaminoacid/nano-hydroxyapatite/calcium sulfate (PAA/HA/CS) Cage (PHC Cage) in lumbar fusion surgery. Thirty cases undergoing lumbar fusion of single segment between March and September 2014 were enrolled in this study. The patients were randomly divided into the trial group (n = 20) and the control group (n = 10). The PHC Cage was implanted in the trial group, while the polyetheretherketone (PEEK) Cage was implanted in the control group. The patients of 2 groups mainly presented lumbocrural pain and lower limb radiation pain or numbness. There was no significant difference in gender, age, type, affected segment, disease duration, preoperative intervertebral height, the lordosis angle of fusion segments, and the Oswestry Disability Index (ODI) between 2 groups (P > 0.05). Lateral lumbar X-ray films and three dimensional CT were taken preoperatively and at 1 week and 3, 6, and 12 months postoperatively. The intervertebral height and the lordosis angle of fusion segments at 1 week and 3, 6, and 12 months after operation and ODI at 3, 6, and 12 months after operation were measured; and the bone graft fusion rate was evaluated according to Brantigan criteria. There was no significant difference in operation time, intraoperative blood loss, and the amount of autologous blood transfusion between 2 groups (P > 0.05). Healing by first intention as obtained in 30 cses. All patients were followd up 12 months. The intervertebral height of fusion segments, the lordosis angle of fusion segments, and ODI at each time point after operation were significantly improved when compared with preoperative ones (P < 0.05). The ODI showed significant difference between 3 months and 6, 12 months (P < 0.05), but there was no significant difference between the other time points after operation (P > 0.05). There was no significant difference in the intervertebral height and the lordosis angle of fusion segments between groups at different time points (P > 0.05). There was no significant difference in the above indexes between the trial group and the control group at each time point (P > 0.05). At last follow-up, 5 cases were rated as Brantigan grade E, 13 cases as grade D, and 2 cases as grade C in the trial group; 4 cases were rated grade E, 5 cases as grade D, and 1 case as grade C in the control group. The bone fusion rate was 90% in 2 groups. The PHC Cage can effectively restore and maintain the disc height of fusion segment, normal sequence and biomechanical stability of the lumbar spine. The PHC Cage is similar to the PEEK Cage and has good clinical outcome in short-term follow-up.
- 11 January 2016
- Published by Springer Nature in Dysphagia
- Vol. 31 (2) , 134-145
A Meta-Analysis of the Incidence of Patient-Reported Dysphagia After Anterior Cervical Decompression and Fusion with the Zero-Profile Implant System
Dysphagia is a well-known complication following anterior cervical surgery. It has been reported that the Zero-profile Implant System can decrease the incidence of dysphagia following surgery, however, dysphagia after anterior cervical decompression and fusion (ACDF) with the Zero-profile Implant System remains controversial. Previous studies only focus on small sample sizes. The objective of this study was to determine the incidence of dysphagia after ACDF with the Zero-profile Implant System. Studies were collected from PubMed, EMBASE, the Cochrane library and the China Knowledge Resource Integrated Database using the keywords “Zero-profile OR Zero-p) AND (dysphagia OR [swallowing dysfunction]”. The software STATA (Version 13.0) was used for statistical analysis. Statistical heterogeneity across the various trials, a test of publication bias and sensitivity analysis was performed. 30 studies with a total of 1062 patients were included in this meta-analysis. The occurrence of post-operative transient dysphagia ranged from 0 to 76 % whilst the pooled incidence was 15.6 % (95 % CI, 12.6, 18.5 %). 23 studies reported no persistent dysphagia whilst seven studies reported persistent dysphagia ranging from 1 to 7 %). In summary, the present study observed a low incidence of both transient and persistent dysphagia after ACDF using the Zero-profile Implant System. Most of the dysphagia was mild and gradually decreased during the following months. Moderate or severe dysphagia was uncommon. Future randomized controlled multi-center studies and those focusing on the mechanisms of dysphagia and methods to reduce its incidence are required.
- 11 January 2016
- Published by Springer Nature in Dysphagia
- Vol. 31 (2) , 134-145
A Meta-Analysis of the Incidence of Patient-Reported Dysphagia After Anterior Cervical Decompression and Fusion with the Zero-Profile Implant System
Dysphagia is a well-known complication following anterior cervical surgery. It has been reported that the Zero-profile Implant System can decrease the incidence of dysphagia following surgery, however, dysphagia after anterior cervical decompression and fusion (ACDF) with the Zero-profile Implant System remains controversial. Previous studies only focus on small sample sizes. The objective of this study was to determine the incidence of dysphagia after ACDF with the Zero-profile Implant System. Studies were collected from PubMed, EMBASE, the Cochrane library and the China Knowledge Resource Integrated Database using the keywords “Zero-profile OR Zero-p) AND (dysphagia OR [swallowing dysfunction]”. The software STATA (Version 13.0) was used for statistical analysis. Statistical heterogeneity across the various trials, a test of publication bias and sensitivity analysis was performed. 30 studies with a total of 1062 patients were included in this meta-analysis. The occurrence of post-operative transient dysphagia ranged from 0 to 76 % whilst the pooled incidence was 15.6 % (95 % CI, 12.6, 18.5 %). 23 studies reported no persistent dysphagia whilst seven studies reported persistent dysphagia ranging from 1 to 7 %). In summary, the present study observed a low incidence of both transient and persistent dysphagia after ACDF using the Zero-profile Implant System. Most of the dysphagia was mild and gradually decreased during the following months. Moderate or severe dysphagia was uncommon. Future randomized controlled multi-center studies and those focusing on the mechanisms of dysphagia and methods to reduce its incidence are required.
- 1 August 2015
- Vol. 28 (8) , 717-21
[Prevention of postoperative cerebrospinal fluid leakage with absorbable hemostatic fluid gelatin].
To explore the effectiveness of absorbable hemostatic fluid gelatin in preventing postoperative cerebrospinal fluid leakage. The clinical data of 17 patients with dura mater tear were retrospectively analyzed from March to September in 2003. There were 16 males and 1 female, aged from 16 to 67 years old with an average of (39.6 ± 15.4) years. The injury site was at cervical vertebrae in 1 case, thoracic vertebrae in 9 cases, thoracolumbar junction in 4 cases, lumbar vertebrae in 3 cases. There were burst fracture in 4 cases and fracture-dislocation in 13 cases. According to ASIA grade, 12 cases were grade A, 2 cases were grade B, 2 cases were grade D, 1 case were grade E. Two cases caused by traffic accident, 10 by high falling, 4 by heavy parts crash, 1 by stairs fell during the earthquake. Absorbable hemostatic fluid gelatins were used to plug the dura mater tear,in order to prevent postoperative cerebrospinal fluid leakage. Postoperative drainage were recorded every day. Of 17 patients, 15 cases did not develop with cerebrospinal fluid leakage. Two cases develop with cerebrospinal fluid leakage after operation and their drainage were removed at 6 to 7 days after operation. In all cases, no complications related with cerebrospinal fluid leakage occurred, such as headache, dizzy, fever,neck resistance, rash, incision disunion, incision infection, hematoma, neurologic symptoms aggravation. No abnormal phenomena was found on incision surrounding at follow-up of 9 months. Using absorbable hemostatic fluid gelatin to plug the dura mater tear during operation is an effective method in preventing postoperative cerebrospinal fluid leakage.
- 1 August 2015
- Vol. 28 (8) , 717-21
[Prevention of postoperative cerebrospinal fluid leakage with absorbable hemostatic fluid gelatin].
To explore the effectiveness of absorbable hemostatic fluid gelatin in preventing postoperative cerebrospinal fluid leakage. The clinical data of 17 patients with dura mater tear were retrospectively analyzed from March to September in 2003. There were 16 males and 1 female, aged from 16 to 67 years old with an average of (39.6 ± 15.4) years. The injury site was at cervical vertebrae in 1 case, thoracic vertebrae in 9 cases, thoracolumbar junction in 4 cases, lumbar vertebrae in 3 cases. There were burst fracture in 4 cases and fracture-dislocation in 13 cases. According to ASIA grade, 12 cases were grade A, 2 cases were grade B, 2 cases were grade D, 1 case were grade E. Two cases caused by traffic accident, 10 by high falling, 4 by heavy parts crash, 1 by stairs fell during the earthquake. Absorbable hemostatic fluid gelatins were used to plug the dura mater tear,in order to prevent postoperative cerebrospinal fluid leakage. Postoperative drainage were recorded every day. Of 17 patients, 15 cases did not develop with cerebrospinal fluid leakage. Two cases develop with cerebrospinal fluid leakage after operation and their drainage were removed at 6 to 7 days after operation. In all cases, no complications related with cerebrospinal fluid leakage occurred, such as headache, dizzy, fever,neck resistance, rash, incision disunion, incision infection, hematoma, neurologic symptoms aggravation. No abnormal phenomena was found on incision surrounding at follow-up of 9 months. Using absorbable hemostatic fluid gelatin to plug the dura mater tear during operation is an effective method in preventing postoperative cerebrospinal fluid leakage.
- 1 December 2012
- Vol. 25 (12) , 1005-9
[Comparison of screw' inserting angle through the 11th and 12th rib anterior approaches for L1 burst fracture].
To compare screw's inserting angle through the 11th and 12th rib in treating L1 burst fracture, explore effects on inserting screw and postoperative angle. From October 2007 to October 2010, 108 patients with L1 brust fracture treated through anterior approach were analyzed,including 68 males and 40 females, aged from 21 to 64 years (mean 38.22 years). All patients were divided into the 11th (A, 51 cases) and 12th (B, 57 cases) approach. The data of operation time,blood loss, duration of incision pain, JOA score, Oswestry score, VAS score, quality of life (SF-36), recovery of nervous function, coronal Cobb angle, included angle between screw and plate were observed. All patients were followed up for 9 to 37 months, mean 23 months. The operation time, blood loss, duration of incision pain, in group A were lower than group B (P0.05). There were no differences in Cobb angle before operation, but had significance after operation (P=0.000). There were statistically significance between two group in angle between screw and plate (P=0.000, P=0.003). The 11th rib approach for the treatment of L1 burst fracture has less effects on screw, less trauma and less angle between screw and plate.
- 1 December 2012
- Vol. 25 (12) , 1005-9
[Comparison of screw' inserting angle through the 11th and 12th rib anterior approaches for L1 burst fracture].
To compare screw's inserting angle through the 11th and 12th rib in treating L1 burst fracture, explore effects on inserting screw and postoperative angle. From October 2007 to October 2010, 108 patients with L1 brust fracture treated through anterior approach were analyzed,including 68 males and 40 females, aged from 21 to 64 years (mean 38.22 years). All patients were divided into the 11th (A, 51 cases) and 12th (B, 57 cases) approach. The data of operation time,blood loss, duration of incision pain, JOA score, Oswestry score, VAS score, quality of life (SF-36), recovery of nervous function, coronal Cobb angle, included angle between screw and plate were observed. All patients were followed up for 9 to 37 months, mean 23 months. The operation time, blood loss, duration of incision pain, in group A were lower than group B (P0.05). There were no differences in Cobb angle before operation, but had significance after operation (P=0.000). There were statistically significance between two group in angle between screw and plate (P=0.000, P=0.003). The 11th rib approach for the treatment of L1 burst fracture has less effects on screw, less trauma and less angle between screw and plate.