Colien Hazelaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Colien Hazelaar has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Max Dahele
Department of Radiation Oncology, Cancer Center Amsterdam, VU University Medical Center, Amsterdam, The Netherlands
5 shared publicationsWilko F.A.R. Verbakel
Department of Radiation Oncology, Cancer Center Amsterdam, VU University Medical Center, Amsterdam, The Netherlands
4 shared publicationsBen J. Slotman
Department of Radiation Oncology, Cancer Center Amsterdam, VU University Medical Center, Amsterdam, The Netherlands
3 shared publicationsHassan Mostafavi
Varian Medical Systems, Palo Alto, California
3 shared publicationsLineke van der Weide
Department of Radiation Oncology, Cancer Center Amsterdam, VU University Medical Center, Amsterdam, The Netherlands
3 shared publicationsBen J Slotman
Radiation Oncology, VU University Medical Center, Amsterdam, NETHERLANDS
1 shared publication
Latest Publications
- 1 November 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 129 (2) , 234-241
Feasibility of markerless 3D position monitoring of the central airways using kilovoltage projection images: Managing the risks of central lung stereotactic radiotherapy
- 1 November 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 129 (2) , 234-241
Feasibility of markerless 3D position monitoring of the central airways using kilovoltage projection images: Managing the risks of central lung stereotactic radiotherapy
- 1 August 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 101 (5) , 1253-1258
First Experience With Markerless Online 3D Spine Position Monitoring During SBRT Delivery Using a Conventional LINAC
- 1 August 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 101 (5) , 1253-1258
First Experience With Markerless Online 3D Spine Position Monitoring During SBRT Delivery Using a Conventional LINAC
- 29 May 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (11) , 115005
Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold
Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching + triangulation of kV projection images acquired during breath-hold stereotactic treatments could determine 3D tumor position. Band-pass filtering and/or digital tomosynthesis (DTS) were used as image pre-filtering/enhancement techniques. On-board kV images continuously acquired during volumetric modulated arc irradiation of (i) a 3D-printed anthropomorphic thorax phantom with three lung tumors (n = 6 stationary datasets, n = 2 gradually moving), and (ii) four patients (13 datasets) were analyzed. 2D reference templates (filtered DRRs) were created from planning CT data. Normalized cross-correlation was used for 2D matching between templates and pre-filtered/enhanced kV images. For 3D verification, each registration was triangulated with multiple previous registrations. Generally applicable image processing/algorithm settings for lung tumors in breath-hold were identified. For the stationary phantom, the interquartile range of the 3D position vector was on average 0.25 mm for 12° DTS + band-pass filtering (average detected positions in 2D = 99.7%, 3D = 96.1%, and 3D excluding first 12° due to triangulation angle = 99.9%) compared to 0.81 mm for band-pass filtering only (55.8/52.9/55.0%). For the moving phantom, RMS errors for the lateral/longitudinal/vertical direction after 12° DTS + band-pass filtering were 1.5/0.4/1.1 mm and 2.2/0.3/3.2 mm. For the clinical data, 2D position was determined for at least 93% of each dataset and 3D position excluding first 12° for at least 82% of each dataset using 12° DTS + band-pass filtering. Template matching + triangulation using DTS + band-pass filtered images could accurately determine the position of stationary lung tumors. However, triangulation was less accurate/reliable for targets with continuous, gradual displacement in the lateral and vertical directions. This technique is therefore currently most suited to detect/monitor offsets occurring between initial setup and the start of treatment, inter-breath-hold variations, and tumors with predominantly longitudinal motion.
- 29 May 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (11) , 115005
Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold
Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching + triangulation of kV projection images acquired during breath-hold stereotactic treatments could determine 3D tumor position. Band-pass filtering and/or digital tomosynthesis (DTS) were used as image pre-filtering/enhancement techniques. On-board kV images continuously acquired during volumetric modulated arc irradiation of (i) a 3D-printed anthropomorphic thorax phantom with three lung tumors (n = 6 stationary datasets, n = 2 gradually moving), and (ii) four patients (13 datasets) were analyzed. 2D reference templates (filtered DRRs) were created from planning CT data. Normalized cross-correlation was used for 2D matching between templates and pre-filtered/enhanced kV images. For 3D verification, each registration was triangulated with multiple previous registrations. Generally applicable image processing/algorithm settings for lung tumors in breath-hold were identified. For the stationary phantom, the interquartile range of the 3D position vector was on average 0.25 mm for 12° DTS + band-pass filtering (average detected positions in 2D = 99.7%, 3D = 96.1%, and 3D excluding first 12° due to triangulation angle = 99.9%) compared to 0.81 mm for band-pass filtering only (55.8/52.9/55.0%). For the moving phantom, RMS errors for the lateral/longitudinal/vertical direction after 12° DTS + band-pass filtering were 1.5/0.4/1.1 mm and 2.2/0.3/3.2 mm. For the clinical data, 2D position was determined for at least 93% of each dataset and 3D position excluding first 12° for at least 82% of each dataset using 12° DTS + band-pass filtering. Template matching + triangulation using DTS + band-pass filtered images could accurately determine the position of stationary lung tumors. However, triangulation was less accurate/reliable for targets with continuous, gradual displacement in the lateral and vertical directions. This technique is therefore currently most suited to detect/monitor offsets occurring between initial setup and the start of treatment, inter-breath-hold variations, and tumors with predominantly longitudinal motion.
- 19 November 2017
- Published by Wiley in Medical Physics
- Vol. 45 (1) , 92-100
Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes
Purpose: Imaging phantoms are widely used for testing and optimization of imaging devices without the need to expose humans to irradiation. However, commercially available phantoms are commonly manufactured in simple, generic forms and sizes and therefore do not resemble the clinical situation for many patients.Methods: Using 3D printing techniques, we created a life‐size phantom based on a clinical CT scan of the thorax from a patient with lung cancer. It was assembled from bony structures printed in gypsum, lung structures consisting of airways, blood vessels >1 mm, and outer lung surface, three lung tumors printed in nylon, and soft tissues represented by silicone (poured into a 3D‐printed mold).Results: Kilovoltage x‐ray and CT images of the phantom closely resemble those of the real patient in terms of size, shapes, and structures. Surface comparison using 3D models obtained from the phantom and the 3D models used for printing showed mean differences <1 mm for all structures. Tensile tests of the materials used for the phantom show that the phantom is able to endure radiation doses over 24,000 Gy.Conclusions: It is feasible to create an anthropomorphic thorax phantom using 3D printing and molding techniques. The phantom closely resembles a real patient in terms of spatial accuracy and is currently being used to evaluate x‐ray‐based imaging quality and positional verification techniques for radiotherapy.
- 19 November 2017
- Published by Wiley in Medical Physics
- Vol. 45 (1) , 92-100
Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes
Purpose: Imaging phantoms are widely used for testing and optimization of imaging devices without the need to expose humans to irradiation. However, commercially available phantoms are commonly manufactured in simple, generic forms and sizes and therefore do not resemble the clinical situation for many patients.Methods: Using 3D printing techniques, we created a life‐size phantom based on a clinical CT scan of the thorax from a patient with lung cancer. It was assembled from bony structures printed in gypsum, lung structures consisting of airways, blood vessels >1 mm, and outer lung surface, three lung tumors printed in nylon, and soft tissues represented by silicone (poured into a 3D‐printed mold).Results: Kilovoltage x‐ray and CT images of the phantom closely resemble those of the real patient in terms of size, shapes, and structures. Surface comparison using 3D models obtained from the phantom and the 3D models used for printing showed mean differences <1 mm for all structures. Tensile tests of the materials used for the phantom show that the phantom is able to endure radiation doses over 24,000 Gy.Conclusions: It is feasible to create an anthropomorphic thorax phantom using 3D printing and molding techniques. The phantom closely resembles a real patient in terms of spatial accuracy and is currently being used to evaluate x‐ray‐based imaging quality and positional verification techniques for radiotherapy.
- 19 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123 (3) , 355-362
Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging
- 19 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123 (3) , 355-362
Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging
- 1 April 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 94 (5) , 1154-1162
Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions
- 1 April 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 94 (5) , 1154-1162
Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions