Christina Grothusen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christina Grothusen has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Jochen Cremer
Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany
13 shared publications - Helge Möllmann
Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
8 shared publications - Assad Haneya
Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany
7 shared publications - Clemens Eckel
Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
7 shared publications Jochen Cremer
Department of Cardiac and Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Kiel, Germany
7 shared publicationsAssad Haneya
Department of Cardiac and Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Kiel, Germany
6 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 21 (1) , 334
Neurological injury in patients with acute myocardial infarction undergoing operative myocardial revascularization within 48 h
Background: Acute myocardial infarction (AMI) is associated with an increased rate of neurological events (NE). AMI patients, who undergo coronary artery bypass graft (CABG) surgery may be at an even greater risk for peri-operative NE, but detailed data is missing. Methods: We conducted a retrospective, single-center data analysis of 1628 patients that underwent CABG within 48 h after being diagnosed with AMI. Between 01/2001 and 03/2023, 77 patients (4.7%) suffered from a peri-operative NE. This included 66 (4.0%) thromb-embolic strokes and 11 (0.7%) hypoxic brain damages. We compared the outcome between NE patients and those without (w/o) NE. Primary outcome parameters were 30-day mortality and long-term survival. Secondary outcome parameters included post-operative ICU length of stay, transfusion rates and need for renal replacement therapy (RRT). Results: Median time from AMI diagnosis to CABG was 7.6 h (4.4–16.4 h). Significantly more NE patients were smokers ( n = 36(46.8%) vs. n = 532(34.5%); p = 0.04) and presented with a severely reduced left ventricular function pre-operatively ( n = 15(20.3%) vs. n = 161(11.1%); p = 0.02). NE patients had undergone CPR pre-operatively more often than patients w/o NE ( n = 23(29.9%)vs n = 168(10.8%); p < 0.001). Accordingly, EuroScore II was significantly higher in NE patients compared to patients w/o NE (7.8 (4.2–14.3) vs. 4.9 (2.8–10.2); p < 0.001). Intra-operatively, bypass-time proved to be longer in NE patients (117 (94–149) vs. 107 (88–130)minutes; p = 0.02). Post-operatively, significantly more NE patients had to stay longer than 48 h in the ICU ( n = 72 (94.7%) vs. n = 866 (55.8%); p < 0.001). Neither transfusion rates nor need for RRT differed between the groups. Thirty day mortality was higher in NE patients ( n = 16 (20.8%) vs. n = 165 (10.7%); p < 0.01). Pre-operative diagnosis of peripheral artery disease (pad) and need for CPR were identified as independent predictors of 30-day mortality in NE patients. Ten-year survival of NE patients remained impaired compared to patients w/o NE (39% vs. 69%; p < 0.001). Conclusion: AMI Patients undergoing CABG within 48 h are at an increased risk for neurological injuries. In particular, patients with generalized atherosclerosis and those that underwent CPR pre-operatively, seem to represent a vulnerable subgroup. Further studies have to clarify whether individualized peri-operative actions may reduce the stroke rates in this setting.
- 3 June 2026
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 21 (1) , 334
Open AccessNeurological injury in patients with acute myocardial infarction undergoing operative myocardial revascularization within 48 h
Background: Acute myocardial infarction (AMI) is associated with an increased rate of neurological events (NE). AMI patients, who undergo coronary artery bypass graft (CABG) surgery may be at an even greater risk for peri-operative NE, but detailed data is missing. Methods: We conducted a retrospective, single-center data analysis of 1628 patients that underwent CABG within 48 h after being diagnosed with AMI. Between 01/2001 and 03/2023, 77 patients (4.7%) suffered from a peri-operative NE. This included 66 (4.0%) thromb-embolic strokes and 11 (0.7%) hypoxic brain damages. We compared the outcome between NE patients and those without (w/o) NE. Primary outcome parameters were 30-day mortality and long-term survival. Secondary outcome parameters included post-operative ICU length of stay, transfusion rates and need for renal replacement therapy (RRT). Results: Median time from AMI diagnosis to CABG was 7.6 h (4.4–16.4 h). Significantly more NE patients were smokers ( n = 36(46.8%) vs. n = 532(34.5%); p = 0.04) and presented with a severely reduced left ventricular function pre-operatively ( n = 15(20.3%) vs. n = 161(11.1%); p = 0.02). NE patients had undergone CPR pre-operatively more often than patients w/o NE ( n = 23(29.9%)vs n = 168(10.8%); p < 0.001). Accordingly, EuroScore II was significantly higher in NE patients compared to patients w/o NE (7.8 (4.2–14.3) vs. 4.9 (2.8–10.2); p < 0.001). Intra-operatively, bypass-time proved to be longer in NE patients (117 (94–149) vs. 107 (88–130)minutes; p = 0.02). Post-operatively, significantly more NE patients had to stay longer than 48 h in the ICU ( n = 72 (94.7%) vs. n = 866 (55.8%); p < 0.001). Neither transfusion rates nor need for RRT differed between the groups. Thirty day mortality was higher in NE patients ( n = 16 (20.8%) vs. n = 165 (10.7%); p < 0.01). Pre-operative diagnosis of peripheral artery disease (pad) and need for CPR were identified as independent predictors of 30-day mortality in NE patients. Ten-year survival of NE patients remained impaired compared to patients w/o NE (39% vs. 69%; p < 0.001). Conclusion: AMI Patients undergoing CABG within 48 h are at an increased risk for neurological injuries. In particular, patients with generalized atherosclerosis and those that underwent CPR pre-operatively, seem to represent a vulnerable subgroup. Further studies have to clarify whether individualized peri-operative actions may reduce the stroke rates in this setting.
- Open Access
The ADVanced Organ Support (ADVOS) Hemodialysis System in Postoperative Cardiogenic Shock and Multiple Organ Failure: First Results in Cardiac Surgery Patients
Background: The management of multiple organ failure in the vulnerable cohort of cardiac surgery patients with cardiogenic shock remains a significant challenge, often impairing patient survival. A multimodal approach at targeting organ dysfunction seems to be a promising strategy, encompassing both hemodynamic support as well as differentiated organ replacement therapy. Materials and Methods: In our retrospective study we examined the impact of the ADVOS (advanced organ support) system on overall outcomes and survival in an all-comers group of 22 cardiac surgery patients with postoperative cardiogenic shock and multiple organ failure. Aims: The objective of the study was to assess the feasibility and potential benefits of ADVOS treatment in this patient population. Results: The standard care management in combination with ADVOS therapy corrected acid–base balance (pH 7.33 vs. 7.44, p = 0.001; base excess −3.2 vs. 2.4 mmol/L, p < 0.001). This contributed to restoring hemodynamic balance after two consecutive ADVOS treatments (vasoactive inotropic score (VIS) 59 vs. 21, p = 0.007, noradrenaline 0.470 vs. 0.180 µg/kg/min, p = 0.009). Conclusions: Our findings indicate that ADVOS treatment is both feasible and safe, with a substantial proportion of patients demonstrating improvements in organ function and overall outcomes.
Open AccessThe ADVanced Organ Support (ADVOS) Hemodialysis System in Postoperative Cardiogenic Shock and Multiple Organ Failure: First Results in Cardiac Surgery Patients
Background: The management of multiple organ failure in the vulnerable cohort of cardiac surgery patients with cardiogenic shock remains a significant challenge, often impairing patient survival. A multimodal approach at targeting organ dysfunction seems to be a promising strategy, encompassing both hemodynamic support as well as differentiated organ replacement therapy. Materials and Methods: In our retrospective study we examined the impact of the ADVOS (advanced organ support) system on overall outcomes and survival in an all-comers group of 22 cardiac surgery patients with postoperative cardiogenic shock and multiple organ failure. Aims: The objective of the study was to assess the feasibility and potential benefits of ADVOS treatment in this patient population. Results: The standard care management in combination with ADVOS therapy corrected acid–base balance (pH 7.33 vs. 7.44, p = 0.001; base excess −3.2 vs. 2.4 mmol/L, p < 0.001). This contributed to restoring hemodynamic balance after two consecutive ADVOS treatments (vasoactive inotropic score (VIS) 59 vs. 21, p = 0.007, noradrenaline 0.470 vs. 0.180 µg/kg/min, p = 0.009). Conclusions: Our findings indicate that ADVOS treatment is both feasible and safe, with a substantial proportion of patients demonstrating improvements in organ function and overall outcomes.
- Open Access
- 8 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 1824
Does Intra-Annular Valve Design Equal Intra-Annular Valve Design? Comparison of Two Transcatheter Aortic Valve Prostheses
Background: Prosthesis-patient mismatch (PPM) has been demonstrated to affect the outcome of both surgical (SAVR) and transcatheter aortic valve replacement (TAVR) patients. Supra-annular transcatheter valves (SAV) appear to offer a superior solution to intra-annular valves (IAV) in this regard. However, data on the comparison of the intra-annular self-expanding (SE) NAVITOR and the intra-annular balloon-expandable (BE) Sapien 3 Ultra in small annuli are limited. Methods: A total of 179 patients with severe native aortic valve stenosis were treated with either the SE NAVITOR (SEV; n = 104) or the BE Sapien 3 Ultra (BEV; n = 75) between March 2019 and June 2024. We compared the clinical and hemodynamic outcomes of the cohort according to the implanted prostheses. BMI-adjusted PPM was defined in accordance with the VARC-3 recommendations. Results: The device success at 30 days was superior in patients treated with the NAVITOR prosthesis (94.2% vs. 80.0%, p < 0.001), mainly driven by a higher rate of elevated gradients in the BEV group. The post-procedural mean gradient (8.0 mmHg vs. 13.0 mmHg, p < 0.001) as well as the rate of moderate to severe prosthesis patient mismatch (12.2% vs. 33.3%, p = 0.002) was higher in BEV recipients while the rate of more than moderate paravalvular leakage (PVL) or Valve in Valve (VinV) due to PVL (1.0% vs. 1.3%, p = 1.000) was similar between both groups. Pacemaker implantations were numerically more common after SEV (18.4% vs. 8.5%, p = 0.110). There was a trend towards higher thirty-day all-cause mortality among patients treated with SAV (3.8% vs. 1.3%, p = 0.401). Conclusion: The NAVITOR system may offer a more favorable hemodynamic profile compared to the Sapien 3 Ultra device in patients with small aortic annuli.
- 8 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 1824
Open AccessDoes Intra-Annular Valve Design Equal Intra-Annular Valve Design? Comparison of Two Transcatheter Aortic Valve Prostheses
Background: Prosthesis-patient mismatch (PPM) has been demonstrated to affect the outcome of both surgical (SAVR) and transcatheter aortic valve replacement (TAVR) patients. Supra-annular transcatheter valves (SAV) appear to offer a superior solution to intra-annular valves (IAV) in this regard. However, data on the comparison of the intra-annular self-expanding (SE) NAVITOR and the intra-annular balloon-expandable (BE) Sapien 3 Ultra in small annuli are limited. Methods: A total of 179 patients with severe native aortic valve stenosis were treated with either the SE NAVITOR (SEV; n = 104) or the BE Sapien 3 Ultra (BEV; n = 75) between March 2019 and June 2024. We compared the clinical and hemodynamic outcomes of the cohort according to the implanted prostheses. BMI-adjusted PPM was defined in accordance with the VARC-3 recommendations. Results: The device success at 30 days was superior in patients treated with the NAVITOR prosthesis (94.2% vs. 80.0%, p < 0.001), mainly driven by a higher rate of elevated gradients in the BEV group. The post-procedural mean gradient (8.0 mmHg vs. 13.0 mmHg, p < 0.001) as well as the rate of moderate to severe prosthesis patient mismatch (12.2% vs. 33.3%, p = 0.002) was higher in BEV recipients while the rate of more than moderate paravalvular leakage (PVL) or Valve in Valve (VinV) due to PVL (1.0% vs. 1.3%, p = 1.000) was similar between both groups. Pacemaker implantations were numerically more common after SEV (18.4% vs. 8.5%, p = 0.110). There was a trend towards higher thirty-day all-cause mortality among patients treated with SAV (3.8% vs. 1.3%, p = 0.401). Conclusion: The NAVITOR system may offer a more favorable hemodynamic profile compared to the Sapien 3 Ultra device in patients with small aortic annuli.
- Open Access
- 9 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (17) , 5342
Impact of Accidental High or Low Implantation Depth on Peri-Procedural Outcomes after Implantation with the Self-Expanding ACURATE neo2
Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.
- 9 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (17) , 5342
Open AccessImpact of Accidental High or Low Implantation Depth on Peri-Procedural Outcomes after Implantation with the Self-Expanding ACURATE neo2
Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.
- Open Access
- 17 July 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (14) , 4187
Early Outcomes of Two Large Mitral Valve Transcatheter Edge-to-Edge Repair Devices—A Propensity Score Matched Multicenter Comparison
Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.
- 17 July 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (14) , 4187
Open AccessEarly Outcomes of Two Large Mitral Valve Transcatheter Edge-to-Edge Repair Devices—A Propensity Score Matched Multicenter Comparison
Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.
- Open Access
- 9 November 2023
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 30 (6) , 1003-1009
Long-term follow-up of patients with complex coronary artery disease treated with minimally invasive direct coronary artery bypass
Background: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive coronary artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. Methods: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). Results: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). Conclusions: Minimally invasive coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal. Background: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive coronary artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. Methods: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). Results: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). Conclusions: Minimally invasive coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal.
- 9 November 2023
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 30 (6) , 1003-1009
Open AccessLong-term follow-up of patients with complex coronary artery disease treated with minimally invasive direct coronary artery bypass
Background: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive coronary artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. Methods: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). Results: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). Conclusions: Minimally invasive coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal. Background: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive coronary artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. Methods: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). Results: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). Conclusions: Minimally invasive coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal.
- Open Access
- 12 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (12) , 3999
Comparison of the New-Generation Self-Expanding NAVITOR Transcatheter Heart Valve with Its Predecessor, the PORTICO, in Severe Native Aortic Valve Stenosis
Background: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. Aims: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. Methods: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. Results: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). Conclusions: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.
- 12 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (12) , 3999
Open AccessComparison of the New-Generation Self-Expanding NAVITOR Transcatheter Heart Valve with Its Predecessor, the PORTICO, in Severe Native Aortic Valve Stenosis
Background: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. Aims: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. Methods: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. Results: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). Conclusions: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.
- Open Access
- 6 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1357
Prognostic Impact of the Get-with-the-Guidelines Heart-Failure Risk Score (GWTG-HF) after Transcatheter Aortic Valve Replacement in Patients with Low-Flow–Low-Gradient Aortic Valve Stenosis
Objectives: This study examined the prognostic value of the get-with-the-guidelines heart-failure risk score (GWTG-HF) on mortality in patients with low-flow–low-gradient aortic valve stenosis (LFLG-AS) after transcatheter aortic valve implantation (TAVI). Background: Data on feasibility of TAVI and mortality prediction in the LFLG-AS population are scarce. Clinical risk assessment in this particular population is difficult, and a score has not yet been established for this purpose. Methods: A total of 212 heart failure (HF) patients with real LFLG-AS were enrolled. Patients were classified into low-risk (n = 108), intermediate-risk (n = 90) and high-risk (n = 14) groups calculated by the GWTG-HF score. Clinical outcomes of cardiovascular events according to Valve Academic Research Consortium (VARC-2) recommendations and composite endpoint of death and hospitalization for heart failure (HHF) were assessed at discharge and 1 year of follow-up. Results: Baseline parameters of the groups showed a median age of 81.0 years [77.0; 84.0] (79.0 vs. 82.0 vs. 86.0, respectively p < 0.001), median EuroSCORE II of 6.6 [4.3; 10.7] (5.5 vs. 7.2 vs. 9.1, p = 0.004) and median indexed stroke volume of 26.7 mL/m2 [22.0; 31.0] (28.2 vs. 25.8 vs. 25.0, p = 0.004). The groups significantly differed at follow-up in terms of all-cause mortality (10.2 vs. 21.1 vs. 28.6%; p < 0.035). There was no difference in intrahospital event rate (VARC). Postprocedural mean gradients were lower in high-risk group (7.0 vs. 7.0 vs. 5.0 mmHg, p = 0.011). No differences in postprocedural aortic valve area (1.9 vs. 1.7 vs. 1.9 cm2, p = 0.518) or rate of device failure (5.6 vs. 6.8 vs. 7.7%, p = 0.731) could be observed. After adjustment for known predictors, the GWTG score (HR 1.07 [1.01–1.14], p = 0.030) as well as pacemaker implantation (HR 3.97 [1.34–11.75], p = 0.013) turned out to be possible predictors for mortality. An increase in stroke volume index (SVI) was, in contrast, protective (HR 0.90 [0.83–0.97]; p = 0.006). Conclusions: The GWTG score may predict mortality after TAVI in LFLG-AS HF patients. Interestingly, all groups showed similar intrahospital event and mortality rates, independent of calculated mortality risk. Low SVI and new conduction disturbances associated with PPI after THV implantation had negative impact on mid-term outcome in post-TAVI HF-patients.
- 6 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1357
Open AccessPrognostic Impact of the Get-with-the-Guidelines Heart-Failure Risk Score (GWTG-HF) after Transcatheter Aortic Valve Replacement in Patients with Low-Flow–Low-Gradient Aortic Valve Stenosis
Objectives: This study examined the prognostic value of the get-with-the-guidelines heart-failure risk score (GWTG-HF) on mortality in patients with low-flow–low-gradient aortic valve stenosis (LFLG-AS) after transcatheter aortic valve implantation (TAVI). Background: Data on feasibility of TAVI and mortality prediction in the LFLG-AS population are scarce. Clinical risk assessment in this particular population is difficult, and a score has not yet been established for this purpose. Methods: A total of 212 heart failure (HF) patients with real LFLG-AS were enrolled. Patients were classified into low-risk (n = 108), intermediate-risk (n = 90) and high-risk (n = 14) groups calculated by the GWTG-HF score. Clinical outcomes of cardiovascular events according to Valve Academic Research Consortium (VARC-2) recommendations and composite endpoint of death and hospitalization for heart failure (HHF) were assessed at discharge and 1 year of follow-up. Results: Baseline parameters of the groups showed a median age of 81.0 years [77.0; 84.0] (79.0 vs. 82.0 vs. 86.0, respectively p < 0.001), median EuroSCORE II of 6.6 [4.3; 10.7] (5.5 vs. 7.2 vs. 9.1, p = 0.004) and median indexed stroke volume of 26.7 mL/m2 [22.0; 31.0] (28.2 vs. 25.8 vs. 25.0, p = 0.004). The groups significantly differed at follow-up in terms of all-cause mortality (10.2 vs. 21.1 vs. 28.6%; p < 0.035). There was no difference in intrahospital event rate (VARC). Postprocedural mean gradients were lower in high-risk group (7.0 vs. 7.0 vs. 5.0 mmHg, p = 0.011). No differences in postprocedural aortic valve area (1.9 vs. 1.7 vs. 1.9 cm2, p = 0.518) or rate of device failure (5.6 vs. 6.8 vs. 7.7%, p = 0.731) could be observed. After adjustment for known predictors, the GWTG score (HR 1.07 [1.01–1.14], p = 0.030) as well as pacemaker implantation (HR 3.97 [1.34–11.75], p = 0.013) turned out to be possible predictors for mortality. An increase in stroke volume index (SVI) was, in contrast, protective (HR 0.90 [0.83–0.97]; p = 0.006). Conclusions: The GWTG score may predict mortality after TAVI in LFLG-AS HF patients. Interestingly, all groups showed similar intrahospital event and mortality rates, independent of calculated mortality risk. Low SVI and new conduction disturbances associated with PPI after THV implantation had negative impact on mid-term outcome in post-TAVI HF-patients.
- Open Access
- 26 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (3) , 945
Procedural Outcomes of a Self-Expanding Transcatheter Heart Valve in Patients with Porcelain Aorta
Background: Severe calcification of the ascending aorta increases the peri-operative risk for neurological complications in patients with severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) seems to be an optimal treatment option in these patients. However, the impact of the extent of aortic calcification on procedural and neurological outcomes during TAVI is unclear. Methods: Data from 3010 patients with severe native aortic valve stenosis treated with ACURATE neo/neo2 from May 2012 to July 2022 were evaluated and matched by 2-to-1 nearest-neighbor matching to identify one patient with porcelain aorta (PA) (n = 492) compared with two patients without PA (n = 984). PA was additionally subdivided into circumferential (classic PA) (n = 89; 3.0%) and non-circumferential (partial PA) (n = 403; 13.4%) calcification. We compared outcomes according to VARC-3 criteria among patients with and without PA and identified predictors for occurrence of stroke in the overall population. Results: Technical success (88.5% vs. 87.4%, p = 0.589) and device success at 30 days (82.3% vs. 81.5%, p = 0.755) after transcatheter ACURATE neo/neo2 implantation according to VARC-3 definition was high and did not differ between non-calcified aortas or PA. The rate of in-hospital complications according to VARC-3-definitions was low in both groups. Rates of all stroke (3.2% (n = 31) vs. 2.6% (n = 13), p = 0.705) or transitory ischemic attacks (1.1% vs. 1.2%, p = 1.000) did not differ significantly. Thirty-day all-cause mortality did not differ (3.0% vs. 3.2%, RR 1.1; p = 0.775). Overall device migration/embolization (OR 5.0 ), severe bleeding (OR 1.79 ), and major structural cardiac complications (OR 3.37 ) were identified as independent predictors for in-hospital stroke in a multivariate analysis after implantation of ACURATE neo/neo2. Conclusion: A porcelain aorta does not increase the risk of neurological complications after transfemoral ACURATE neo/neo2 implantation. Based on these findings, transfemoral ACURATE neo/neo2 implantation is safe in these particularly vulnerable patients.- 26 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (3) , 945
Open AccessProcedural Outcomes of a Self-Expanding Transcatheter Heart Valve in Patients with Porcelain Aorta
Background: Severe calcification of the ascending aorta increases the peri-operative risk for neurological complications in patients with severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) seems to be an optimal treatment option in these patients. However, the impact of the extent of aortic calcification on procedural and neurological outcomes during TAVI is unclear. Methods: Data from 3010 patients with severe native aortic valve stenosis treated with ACURATE neo/neo2 from May 2012 to July 2022 were evaluated and matched by 2-to-1 nearest-neighbor matching to identify one patient with porcelain aorta (PA) (n = 492) compared with two patients without PA (n = 984). PA was additionally subdivided into circumferential (classic PA) (n = 89; 3.0%) and non-circumferential (partial PA) (n = 403; 13.4%) calcification. We compared outcomes according to VARC-3 criteria among patients with and without PA and identified predictors for occurrence of stroke in the overall population. Results: Technical success (88.5% vs. 87.4%, p = 0.589) and device success at 30 days (82.3% vs. 81.5%, p = 0.755) after transcatheter ACURATE neo/neo2 implantation according to VARC-3 definition was high and did not differ between non-calcified aortas or PA. The rate of in-hospital complications according to VARC-3-definitions was low in both groups. Rates of all stroke (3.2% (n = 31) vs. 2.6% (n = 13), p = 0.705) or transitory ischemic attacks (1.1% vs. 1.2%, p = 1.000) did not differ significantly. Thirty-day all-cause mortality did not differ (3.0% vs. 3.2%, RR 1.1; p = 0.775). Overall device migration/embolization (OR 5.0 ), severe bleeding (OR 1.79 ), and major structural cardiac complications (OR 3.37 ) were identified as independent predictors for in-hospital stroke in a multivariate analysis after implantation of ACURATE neo/neo2. Conclusion: A porcelain aorta does not increase the risk of neurological complications after transfemoral ACURATE neo/neo2 implantation. Based on these findings, transfemoral ACURATE neo/neo2 implantation is safe in these particularly vulnerable patients. - Open Access
- 9 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (18) , 5313
Procedural Outcomes of a Self-Expanding Transcatheter Heart Valve in Small Annuli
Background: Self-expanding transcatheter valves (THV) seem superior to balloon-expanding valves in regard to the incidence of prosthesis–patient mismatch (PPM). Data on the occurrence of PPM with the ACURATE neo/neo2 system as a representative of self-expanding prostheses in very small annuli, even below the applicable instructions for use (IFU), are scarce. Methods: Data from 654 patients with severe native aortic stenosis treated with the smallest size ACURATE neo/neo2 valve (size S, 23 mm) at two German high-volume centers from 06/2012 to 12/2021 were evaluated. We compared clinical and hemodynamic outcomes among patients with implantation in adherence to the recommended sizing (on-label n = 529) and below the recommended sizing range (off-label n = 125) and identified predictors for PPM in the overall population. BMI-adjusted PPM was defined according to VARC-3 recommendations. Results: Post-procedure, the mean gradient (10.0 mmHg vs. 9.0 mmHg, p = 0.834) and the rate of paravalvular leakage (PVL) ≥ moderate (3.2% vs. 2.8%, p = 0.770) were similar between on-label and off-label implantations. The rate of moderate to severe PPM (24%) was comparably low in ACURATE neo/neo2 S, with a very low proportion of severe PPM whether implanted off- or on-label (4.9% vs. 3.8%, p = 0.552). Thirty-day all-cause mortality was higher among patients with off-label implantations (6.5% vs. 2.3%, p = 0.036). In the subgroup of these patients, no device-related deaths occurred, and cardiac causes did not differ (each 5). Besides small annulus area and high BMI, a multivariate analysis identified a greater cover index (OR 3.26), deep implantation (OR 2.25) and severe calcification (OR 2.07) as independent predictors of PPM. Conclusions: The ACURATE neo/neo2 S subgroup shows a convincing hemodynamic outcome according to low mean gradient even outside the previous IFUs without a relevant increase in the rate of PVL or PPM. In addition to known factors such as annulus area and BMI, potential predictors for PPM are severe annulus calcification and implantation depth. Nevertheless, the ACURATE neo/neo2 system seems to be a reliable option in patients with very small annuli.
- 9 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (18) , 5313
Open AccessProcedural Outcomes of a Self-Expanding Transcatheter Heart Valve in Small Annuli
Background: Self-expanding transcatheter valves (THV) seem superior to balloon-expanding valves in regard to the incidence of prosthesis–patient mismatch (PPM). Data on the occurrence of PPM with the ACURATE neo/neo2 system as a representative of self-expanding prostheses in very small annuli, even below the applicable instructions for use (IFU), are scarce. Methods: Data from 654 patients with severe native aortic stenosis treated with the smallest size ACURATE neo/neo2 valve (size S, 23 mm) at two German high-volume centers from 06/2012 to 12/2021 were evaluated. We compared clinical and hemodynamic outcomes among patients with implantation in adherence to the recommended sizing (on-label n = 529) and below the recommended sizing range (off-label n = 125) and identified predictors for PPM in the overall population. BMI-adjusted PPM was defined according to VARC-3 recommendations. Results: Post-procedure, the mean gradient (10.0 mmHg vs. 9.0 mmHg, p = 0.834) and the rate of paravalvular leakage (PVL) ≥ moderate (3.2% vs. 2.8%, p = 0.770) were similar between on-label and off-label implantations. The rate of moderate to severe PPM (24%) was comparably low in ACURATE neo/neo2 S, with a very low proportion of severe PPM whether implanted off- or on-label (4.9% vs. 3.8%, p = 0.552). Thirty-day all-cause mortality was higher among patients with off-label implantations (6.5% vs. 2.3%, p = 0.036). In the subgroup of these patients, no device-related deaths occurred, and cardiac causes did not differ (each 5). Besides small annulus area and high BMI, a multivariate analysis identified a greater cover index (OR 3.26), deep implantation (OR 2.25) and severe calcification (OR 2.07) as independent predictors of PPM. Conclusions: The ACURATE neo/neo2 S subgroup shows a convincing hemodynamic outcome according to low mean gradient even outside the previous IFUs without a relevant increase in the rate of PVL or PPM. In addition to known factors such as annulus area and BMI, potential predictors for PPM are severe annulus calcification and implantation depth. Nevertheless, the ACURATE neo/neo2 system seems to be a reliable option in patients with very small annuli.