Federico Casanova
Research Subjects
Federico Casanova has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Benita Claire Percival
Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
2 shared publications - Martin Grootveld
Leicester School of Pharmacy, Faculty of Health and Life Sciences, De Montfort University, The Gateway, Leicester LE1 9BH, UK
2 shared publications - Philippe Barrie Wilson
Nottingham Trent University
2 shared publications - Fereshteh Jafari
Biomedical & Environmental Health, Leicester School of Pharmacy, Health and Life Sciences Faculty, DMU, Leicester, UK
1 shared publication - Jinit Masania
Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
1 shared publication - Justine Leenders
Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE8 9BH, UK
1 shared publication
Latest Publications
- Open Access
- 16 April 2020
- Published by MDPI AG in Metabolites
- Vol. 10 (4) , 155
Benchtop Low-Frequency 60 MHz NMR Analysis of Urine: A Comparative Metabolomics Investigation
Metabolomics techniques are now applied in numerous fields, with the ability to provide information concerning a large number of metabolites from a single sample in a short timeframe. Although high-frequency (HF) nuclear magnetic resonance (NMR) analysis represents a common method of choice to perform such studies, few investigations employing low-frequency (LF) NMR spectrometers have yet been published. Herein, we apply and contrast LF and HF 1H-NMR metabolomics approaches to the study of urine samples collected from type 2 diabetic patients (T2D), and apply a comparative investigation with healthy controls. Additionally, we explore the capabilities of LF 1H-1H 2D correlation spectroscopy (COSY) experiments regarding the determination of metabolites, their resolution and associated analyses in human urine samples. T2D samples were readily distinguishable from controls, with several metabolites, particularly glucose, being associated with this distinction. Comparable results were obtained with HF and LF spectrometers. Linear correlation analyses were performed to derive relationships between the intensities of 1D and 2D resonances of several metabolites, and R2 values obtained were able to confirm these, an observation attesting to the validity of employing 2D LF experiments for future applications in metabolomics studies. Our data suggest that LF spectrometers may prove to be easy-to-use, compact and inexpensive tools to perform routine metabolomics analyses in laboratories and ‘point-of-care’ sites. Furthermore, the quality of 2D spectra obtained from these instruments in half an hour would broaden the horizon of their potential applications.
- 16 April 2020
- Published by MDPI AG in Metabolites
- Vol. 10 (4) , 155
Open AccessBenchtop Low-Frequency 60 MHz NMR Analysis of Urine: A Comparative Metabolomics Investigation
Metabolomics techniques are now applied in numerous fields, with the ability to provide information concerning a large number of metabolites from a single sample in a short timeframe. Although high-frequency (HF) nuclear magnetic resonance (NMR) analysis represents a common method of choice to perform such studies, few investigations employing low-frequency (LF) NMR spectrometers have yet been published. Herein, we apply and contrast LF and HF 1H-NMR metabolomics approaches to the study of urine samples collected from type 2 diabetic patients (T2D), and apply a comparative investigation with healthy controls. Additionally, we explore the capabilities of LF 1H-1H 2D correlation spectroscopy (COSY) experiments regarding the determination of metabolites, their resolution and associated analyses in human urine samples. T2D samples were readily distinguishable from controls, with several metabolites, particularly glucose, being associated with this distinction. Comparable results were obtained with HF and LF spectrometers. Linear correlation analyses were performed to derive relationships between the intensities of 1D and 2D resonances of several metabolites, and R2 values obtained were able to confirm these, an observation attesting to the validity of employing 2D LF experiments for future applications in metabolomics studies. Our data suggest that LF spectrometers may prove to be easy-to-use, compact and inexpensive tools to perform routine metabolomics analyses in laboratories and ‘point-of-care’ sites. Furthermore, the quality of 2D spectra obtained from these instruments in half an hour would broaden the horizon of their potential applications.
- Open Access
Low-Field, Benchtop NMR Spectroscopy as a Potential Tool for Point-of-Care Diagnostics of Metabolic Conditions: Validation, Protocols and Computational Models
Novel sensing technologies for liquid biopsies offer promising prospects for the early detection of metabolic conditions through omics techniques. Indeed, high-field nuclear magnetic resonance (NMR) facilities are routinely used for metabolomics investigations on a range of biofluids in order to rapidly recognise unusual metabolic patterns in patients suffering from a range of diseases. However, these techniques are restricted by the prohibitively large size and cost of such facilities, suggesting a possible role for smaller, low-field NMR instruments in biofluid analysis. Herein we describe selected biomolecule validation on a low-field benchtop NMR spectrometer (60 MHz), and present an associated protocol for the analysis of biofluids on compact NMR instruments. We successfully detect common markers of diabetic control at low-to-medium concentrations through optimised experiments, including α-glucose (≤2.8 mmol/L) and acetone (25 µmol/L), and additionally in readily accessible biofluids, particularly human urine. We present a combined protocol for the analysis of these biofluids with low-field NMR spectrometers for metabolomics applications, and offer a perspective on the future of this technique appealing to ‘point-of-care’ applications.
Open AccessLow-Field, Benchtop NMR Spectroscopy as a Potential Tool for Point-of-Care Diagnostics of Metabolic Conditions: Validation, Protocols and Computational Models
Novel sensing technologies for liquid biopsies offer promising prospects for the early detection of metabolic conditions through omics techniques. Indeed, high-field nuclear magnetic resonance (NMR) facilities are routinely used for metabolomics investigations on a range of biofluids in order to rapidly recognise unusual metabolic patterns in patients suffering from a range of diseases. However, these techniques are restricted by the prohibitively large size and cost of such facilities, suggesting a possible role for smaller, low-field NMR instruments in biofluid analysis. Herein we describe selected biomolecule validation on a low-field benchtop NMR spectrometer (60 MHz), and present an associated protocol for the analysis of biofluids on compact NMR instruments. We successfully detect common markers of diabetic control at low-to-medium concentrations through optimised experiments, including α-glucose (≤2.8 mmol/L) and acetone (25 µmol/L), and additionally in readily accessible biofluids, particularly human urine. We present a combined protocol for the analysis of these biofluids with low-field NMR spectrometers for metabolomics applications, and offer a perspective on the future of this technique appealing to ‘point-of-care’ applications.