ASAnna-Lena Sahlberg

Anna-Lena Sahlberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna-Lena Sahlberg has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Defining Safe Light Intensity Limits of Near‐Infrared Illumination Avoiding Skin Heating in Medical Optical Diagnostic Methods

    by Anna‐Lena Sahlberg, Sophie Helene von der Sahle, Sara Bergsten, Henrik Palme, Emilie Krite Svanberg

    This study examined the thermal response of human skin in vivo to near‐infrared illumination (764 nm) delivered either as a free laser beam or through direct contact using a dermal diffusive probe. The aim was to quantify skin heating under increasing illumination intensities and to identify safe exposure thresholds for different skin tones and illumination methods. Research participants with skin tones 1–5 (ranging from light to brown) were included. The results show that skin tone significantly influenced heating under free‐beam illumination, whereas temperature increases with dermal probe illumination showed no significant dependence on skin tone. The maximum safe irradiance was determined to be 7.6 mW/mm 2 for free‐beam illumination and 2.3 mW/mm 2 for dermal probe illumination, corresponding to a maximum skin temperature of 43°C. These limits apply to skin tones 1–5, and further research is required to establish safety thresholds for skin tone 6.

  • Open Access

    Extending Human Lung Monitoring by Laser Spectroscopy From Infants Toward Adults: Initial Proof of Concept in a Porcine Lung Model

    by Henrik Palme, Yueyu Lin, Sara Bergsten, Sune Svanberg, Katarina Svanberg, Simona M. Cristescu, Emilie Krite Svanberg, Anna‐Lena Sahlberg

    Lung function monitoring and prompt diagnosis of lung impairment are essential for optimal patient care. During surgery, anesthesia and ventilator assistance are standard, and mechanical ventilation is often required in severe cases, as highlighted during the recent COVID‐19 pandemic. There is a clear need for powerful, real‐time lung surveillance techniques that can provide feedback to ventilator settings. Gas in Scattering Media Absorption Spectroscopy (GASMAS) measures oxygen and water vapor in the gas‐filled cavities of the lungs, enabling assessment of lung aeration and oxygen concentration. Proof‐of‐concept studies in neonates have demonstrated the potential of GASMAS for continuous lung monitoring. This paper presents progress toward extending the method to older children and adults. By employing a semiconductor tapered amplifier, the diode‐laser output at the oxygen absorption wavelength (764 nm) was increased from ~30 mW to 900 mW. This enhanced power enabled model experiments on a polystyrene phantom and on ventilated porcine lungs, with added pork slabs simulating up to 9 cm total tissue thickness. Strong oxygen absorption signals were detected with both external illumination and internal delivery via the tracheal tube, demonstrating the potential of GASMAS for non‐invasive lung monitoring in large tissue phantoms simulating larger patient populations.


  • Directly-excited laser-induced thermal grating spectroscopy and thermometry with carbon dioxide vibrational transition

    by Zihao Song, Ning Zhu, Weitian Wang, Anna-Lena Sahlberg, Xing Chao

    Laser-induced thermal grating spectroscopy (LITGS) has been proved for accurate thermometry and measurement of energy transfer processes in molecules. While electronic transitions are often used for excitation in previous LITGS works, here we report laser-induced thermal gratings formed by direct excitation of CO2 with an infrared (IR) laser at wavelength near 2 μm, with which high signal-to-noise ratio LITGS signals are generated (SNR ∼ 300 at room temperature). A theoretical LITGS model assuming a ‘two-steps’ energy transfer process is used to describe the recorded signal waveform, with relative fitting residuals of less than 10%. Quantitative thermometry is performed in CO2 gas flows between 293 K and 420 K, with a relative uncertainty of 1.6% and a precision of 1.1% defined as the 1-σ standard deviation of 30 repeated measurement. Furthermore, the time constants of vibrational energy transfer at different temperatures are extracted from the temporal signal waveform with a precision better than 80 ns, and the measured results are consistent with the simulation using a detailed vibrational energy transfer model. These results demonstrate IR LITGS as a potential tool for spatially-resolved measurement of the thermophysical properties of fluids, as well as molecular vibrational energy transfer processes.

  • Open Access

    Temperature and Thermal Diffusivity Diagnostics in Laminar Methane Flames Using Infrared Four-Wave Mixing Techniques

    by Zihao Song, Xing Chao, Anna-Lena Sahlberg

    Four-wave mixing techniques, such as coherent anti-Stokes Raman spectroscopy (CARS), laser-induced grating spectroscopy (LIGS), and degenerate four-wave mixing (DFWM), have been widely used in combustion diagnostics due to their advantages of high signal-to-noise ratio (S/N), coherent signal, and spatial resolution. In this work, a nano-second pulsed laser is utilized to generate mid-infrared (near 3 µm) pump beams, exciting the rovibrational transitions of nascent water in flames. Combined LIGS and DFWM measurements are demonstrated in premixed laminar CH 4 /O 2 /N 2 flames with equivalence ratios from 0.6 to 1.5, to achieve precise thermometry in a wide range of flame conditions. The flame temperatures were also measured by thermocouple as a reference, and the results from LIGS and DFWM align well with the trends shown in the thermocouple measurements. In fuel-lean flames, where the mass-to-specific-heat ratio variation is minimal, LIGS provides temperature data with a precision better than 16 K (0.8%). In fuel-rich flames, where the increased H 2 concentration in the flame introduces uncertainty in gas constants thus affecting the accuracy of LIGS thermometry, DFWM is instead employed for temperature measurement since it is less sensitive to the gas composition within the measured volume. The high-precision LIGS temperatures in lean flames serve as temperature reference during the DFWM calibration of the degree of saturation, and a precision better than 90 K (4.5%) is achieved for DFWM thermometry. In addition to temperature, a theoretical model is employed to fit LIGS signal time waveforms, extracting the local speed of sound and thermal diffusivity with precisions better than 0.5% and 1.3%, respectively. These high-precision measurements contribute additional data for flame research and simulation calculations. This way, the combined use of DFWM and LIGS proves the potential for accurate thermometry and diagnostics of other thermodynamic parameters across a wide range of flame conditions.


  • Open Access

    Mid-Infrared Generated Laser-Induced Grating Signals in Methane-Containing Gas Mixtures as Indicators of Composition, Pressure, and Temperature

    by Anna-Lena Sahlberg, Dina Hot, Zhongshan Li, Dimitrii Kozlov

    The present work is aimed at studying how spatially periodic modulations of the refractive index of the medium, i.e., laser-induced gratings (LIGs), generated in a gas mixture containing methane (CH 4 ) by nanosecond pulses of resonant mid-infrared laser radiation, can be used to measure various gas parameters. It is investigated to what extent the temporal profiles of the LIG signals, recorded as the power of the diffracted by LIGs continuous wave probe radiation, are specific to the composition, pressure, and temperature of a selected buffer gas. This specificity is illustrated by the LIG signal profiles recorded in the experiments in different gas mixtures under various conditions. Experimental data show that large LIG signals can be obtained even in mixtures with CH 4 concentrations as low as ∼100 parts per million due to the strong absorption of the excitation light and subsequent rapid, highly exothermic, and partner-dependent collisional energy exchange of the laser-excited molecules with the environment. These two factors ensure high LIG generation efficiency by a small number of CH 4 molecules and high sensitivity of signal strength and profile to variations of gas parameters.

  • Open Access

    Gas in scattering media absorption spectroscopy on small and large scales: Toward the extension of lung spectroscopic monitoring to adults

    by Yueyu Lin, Patrik Lundin, Emilie Krite Svanberg, Katarina Svanberg, Sune Svanberg, Anna‐Lena Sahlberg

    Numerous natural materials are porous, contain free gas and are scattering light strongly. Scattering brings about a strong trapping of light and an associated prolonged transit time for photons through a medium. In contrast to the matrix materials, gas enclosures require very narrowband laser radiation for probing. We have in the present study used the gas in scattering media absorption spectroscopy method to study free oxygen in thin (cm) samples utilizing a tunable diode laser, while a pulsed dye laser was employed in corresponding measurements on larger samples, up to the meter scale. Time‐resolved spectroscopy was in both cases used to assess the temporal distribution of the detected photons, mapping the path lengths through the media, which ranged between few centimeters up to 100 m. This study explores the feasibility to extend recent successful monitoring of gases in neonatal infant lungs to the case of larger children or even adults, which could have very important applications, for example, in ventilator setting optimization for severely ill patients, suffering, for example, from SARS‐CoV‐2. The conclusion of our work is that this goal most realistically can be reached by applying intratracheal laser light illumination at the 1 W power level, employing a tapered amplifier, injected with a distributed feedback diode‐laser oscillator output and combined with wavelength‐modulation spectroscopy.


  • Open Access

    Investigation of laser‐induced grating spectroscopy of O2 for accurate temperature measurements towards applications in harsh environments

    by Dina Hot, Anna‐Lena Sahlberg, Marcus Alden, Zhongshan Li

    We present an in‐depth investigation of laser‐induced grating spectroscopy (LIGS) for temperature measurements in practical applications using a narrow‐band dye laser with 760 nm wavelength and a pulse duration of 8 ns as the source for the pump beams creating the laser‐induced grating. The pump laser wavelength was set to be either resonant with the transition from the band of O2 for generation of thermal LIGS or nonresonant for generation of purely electrostrictive LIGS. Signals were generated in ambient air as well as in high‐pressure or high‐temperature dry air mixtures. Pump laser irradiances up to 11 GW/cm2 were used, which resulted in strong electrostrictive contribution to the overall LIGS signals at atmospheric pressure, with a low thermal contribution due to the weak absorption by the singlet O2 . The advantage and disadvantage of thermal or electrostrictive LIGS for temperature measurements are discussed, as well as potential applications in high‐pressure environments. Furthermore, the precision of the temperature measurement is discussed by comparing different analysis methods.


  • Open Access

    Mid-infrared laser-induced thermal grating spectroscopy of hot water lines for flame thermometry

    by Dina Hot, Anna-Lena Sahlberg, Marcus Aldén, Zhongshan Li


  • Open Access

    Saturation Dependence of Flame Thermometry Using Mid-IR Degenerate Four Wave Mixing

    by Rasmus L. Pedersen, Anna-Lena Sahlberg, Dina Hot, Zhongshan Li

    It has previously been demonstrated that the ratio of the degenerate four wave mixing signal from two hot water line groups near 3231 cm –1 can be used for seedless flame temperature measurements. This paper presents an investigation of the impact of saturation effects on the measured signal intensity from each line group, as well as an estimation of the accuracy of the method. The saturation effects observed here would result in a large systematic error if they are not taken into account when using the degenerate four-wave mixing intensity of these water line groups to calculate the flame temperature.


  • Open Access

    Mid-Infrared Polarization Spectroscopy Measurements of Species Concentrations and Temperature in a Low-Pressure Flame

    by Anna-Lena Sahlberg, Dina Hot, Rasmus Lyngbye-Pedersen, Jianfeng Zhou, Marcus Aldén, Zhongshan Li

    We demonstrate quantitative measurements of methane (CH 4 ) mole fractions in a low-pressure fuel-rich premixed dimethyl ether/oxygen/argon flat flame (Φ = 1.87, 37 mbar) using mid-infrared (IR) polarization spectroscopy (IRPS). Non-intrusive in situ detection of CH 4 , acetylene (C 2 H 2 ), and ethane (C 2 H 6 ) in the flame was realized by probing the fundamental asymmetric C–H stretching vibration bands in the respective molecules in the spectral range 2970–3340 cm −1 . The flame was stabilized on a McKenna-type porous plug burner hosted in a low-pressure chamber. The temperature at different heights above the burner (HAB) was measured from the line ratio of temperature-sensitive H 2 O spectral lines recorded using IRPS. Quantitative measurements of CH 4 mole fractions at different HAB in the flame were realized by a calibration measurement in a low-pressure gas flow of N 2 with a small admixture of known amount of CH 4 . A comprehensive study of the collision effects on the IRPS signal was performed in order to quantify the flame measurement. The concentration and temperature measurements were found to agree reasonably well with simulations using Chemkin. These measurements prove the potential of IRPS as a sensitive, non-intrusive, in situ technique in low pressure flames.