Nina Bjørk Arnfinnsdottir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nina Bjørk Arnfinnsdottir has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Astrid Aksnes
Department of Electronic Systems, Norwegian University of Science and Technology, O.S. Bragstads plass 2b, 7034 Trondheim, Norway
1 shared publication - Bjorn Torger Stokke
Norwegian University of Science and Technology (NTNU)
1 shared publication - Bjørn E. Christensen
NOBIPOL, Department of Biotechnology and Food Science, NTNU Norwegian University of Science and Technology, Sem Sælands vei 6/8, NO-7491 Trondheim, Norway
1 shared publication - Cole A. Chapman
Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
1 shared publication - Göran Widmalm
Stockholm University
1 shared publication - Marianne Øksnes Dalheim
NOBIPOL, Department of Biotechnology and Food Science, NTNU Norwegian University of Science and Technology, N-7491 Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
Impact of Silanization Parameters and Antibody Immobilization Strategy on Binding Capacity of Photonic Ring Resonators
Ring resonator-based biosensors have found widespread application as the transducing principle in “lab-on-a-chip” platforms due to their sensitivity, small size and support for multiplexed sensing. Their sensitivity is, however, not inherently selective towards biomarkers, and surface functionalization of the sensors is key in transforming the sensitivity to be specific for a particular biomarker. There is currently no consensus on process parameters for optimized functionalization of these sensors. Moreover, the procedures are typically optimized on flat silicon oxide substrates as test systems prior to applying the procedure to the actual sensor. Here we present what is, to our knowledge, the first comparison of optimization of silanization on flat silicon oxide substrates to results of protein capture on sensors where all parameters of two conjugation protocols are tested on both platforms. The conjugation protocols differed in the chosen silanization solvents and protein immobilization strategy. The data show that selection of acetic acid as the solvent in the silanization step generally yields a higher protein binding capacity for C-reactive protein (CRP) onto anti-CRP functionalized ring resonator sensors than using ethanol as the solvent. Furthermore, using the BS3 linker resulted in more consistent protein binding capacity across the silanization parameters tested. Overall, the data indicate that selection of parameters in the silanization and immobilization protocols harbor potential for improved biosensor binding capacity and should therefore be included as an essential part of the biosensor development process.
Open AccessImpact of Silanization Parameters and Antibody Immobilization Strategy on Binding Capacity of Photonic Ring Resonators
Ring resonator-based biosensors have found widespread application as the transducing principle in “lab-on-a-chip” platforms due to their sensitivity, small size and support for multiplexed sensing. Their sensitivity is, however, not inherently selective towards biomarkers, and surface functionalization of the sensors is key in transforming the sensitivity to be specific for a particular biomarker. There is currently no consensus on process parameters for optimized functionalization of these sensors. Moreover, the procedures are typically optimized on flat silicon oxide substrates as test systems prior to applying the procedure to the actual sensor. Here we present what is, to our knowledge, the first comparison of optimization of silanization on flat silicon oxide substrates to results of protein capture on sensors where all parameters of two conjugation protocols are tested on both platforms. The conjugation protocols differed in the chosen silanization solvents and protein immobilization strategy. The data show that selection of acetic acid as the solvent in the silanization step generally yields a higher protein binding capacity for C-reactive protein (CRP) onto anti-CRP functionalized ring resonator sensors than using ethanol as the solvent. Furthermore, using the BS3 linker resulted in more consistent protein binding capacity across the silanization parameters tested. Overall, the data indicate that selection of parameters in the silanization and immobilization protocols harbor potential for improved biosensor binding capacity and should therefore be included as an essential part of the biosensor development process.
- 1 May 2016
- Published by Elsevier in Carbohydrate Polymers
- Vol. 142, 91-97
The size and shape of three water-soluble, non-ionic polysaccharides produced by lactic acid bacteria: A comparative study
- 1 May 2016
- Published by Elsevier in Carbohydrate Polymers
- Vol. 142, 91-97
The size and shape of three water-soluble, non-ionic polysaccharides produced by lactic acid bacteria: A comparative study