Yoko Hori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yoko Hori has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Atsuhiro Sakamoto
Department of Anesthesiology, Nippon Medical School, Tokyo, Japan
4 shared publications - Hiroaki Kishikawa
Department of Anesthesiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan
2 shared publications Atsuhiro Sakamoto
Department of Anesthesiology, Nippon Medical School, Sendagi 1-1-5, Bunkyo-ku Tokyo, 113-8603, Japan
1 shared publication- Ayami Nakayama
Department of Anesthesiology, Nippon Medical School, Sendagi 1-1-5, Bunkyo-ku, Tokyo 113-8603, Japan
1 shared publication - Gentaro Goto
Department of Anesthesiology, Nippon Medical School, Sendagi 1-1-5, Bunkyo-ku, Tokyo 113-8603, Japan
1 shared publication Kana Taniguchi
Department of Anesthesiology, Nippon Medical School, Sendagi 1-1-5, Bunkyo-ku Tokyo, 113-8603, Japan
1 shared publication
Latest Publications
- Open Access
- 11 September 2018
- Published by Springer Nature in JA Clinical Reports
- Vol. 4 (1) , 1-2
Skin burn related to pulse oximetry during photodynamic therapy using talaporfin sodium
- 11 September 2018
- Published by Springer Nature in JA Clinical Reports
- Vol. 4 (1) , 1-2
Open AccessSkin burn related to pulse oximetry during photodynamic therapy using talaporfin sodium
- Open Access
- 3 December 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 42
Anesthetic management of a patient with esophageal penetration of a tracheal stent: a case report
Tracheal stent is a good way to maintain a patent airway in case of stenosis. Although anesthesia techniques for the placement of a stent in the trachea of patients with tracheal stenosis have been reported, the management of general anesthesia in patients with a tracheal stent is not well established. We report the anesthetic management in the patient with a partly fractured tracheal stent. A 65-year-old man with colon cancer was scheduled for colectomy under general anesthesia. Eight years ago, a tracheal stent was placed because of lung cancer. Preoperative evaluation revealed that a part of the tracheal stent had penetrated the esophagus. We induced general-epidural anesthesia via spontaneous breathing through a laryngeal mask airway to avoid mediastinal emphysema caused by positive pressure ventilation. The patient has been followed up for 2 years without any respiratory complications. General anesthesia can be safely induced under spontaneous ventilation through a laryngeal mask airway in a patient with a fractured tracheal stent.
- 3 December 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 42
Open AccessAnesthetic management of a patient with esophageal penetration of a tracheal stent: a case report
Tracheal stent is a good way to maintain a patent airway in case of stenosis. Although anesthesia techniques for the placement of a stent in the trachea of patients with tracheal stenosis have been reported, the management of general anesthesia in patients with a tracheal stent is not well established. We report the anesthetic management in the patient with a partly fractured tracheal stent. A 65-year-old man with colon cancer was scheduled for colectomy under general anesthesia. Eight years ago, a tracheal stent was placed because of lung cancer. Preoperative evaluation revealed that a part of the tracheal stent had penetrated the esophagus. We induced general-epidural anesthesia via spontaneous breathing through a laryngeal mask airway to avoid mediastinal emphysema caused by positive pressure ventilation. The patient has been followed up for 2 years without any respiratory complications. General anesthesia can be safely induced under spontaneous ventilation through a laryngeal mask airway in a patient with a fractured tracheal stent.
- Open Access
- 25 November 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 40
Surgery cancellations after entering the operating room
Surgery cancellation results in unavailability of the operating room and loss time. We identified the frequency of and reasons for operation cancellations after patients entered the operating room and assessed the preventability of such cancellations. A retrospective chart review of all scheduled surgical procedures proposed under general anesthesia in a period spanning 2008 to 2016 was performed, and the reasons for cancellation were assessed. A total of 30 surgery procedures were cancelled after the patient had entered the operation room and preparation for general anesthesia had been completed. Ten of 18 cases (55.6%) that were cancelled before general anesthesia induction could have been prevented, accounting for 36.7% of the overall cancellations. The majority of the cancellations after anesthesia were due to the patients’ health status. Improving the systems for checking patients’ medical problems and performing preoperative evaluations can reduce the number of cancellations after the patient has entered the operating room.
- 25 November 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 40
Open AccessSurgery cancellations after entering the operating room
Surgery cancellation results in unavailability of the operating room and loss time. We identified the frequency of and reasons for operation cancellations after patients entered the operating room and assessed the preventability of such cancellations. A retrospective chart review of all scheduled surgical procedures proposed under general anesthesia in a period spanning 2008 to 2016 was performed, and the reasons for cancellation were assessed. A total of 30 surgery procedures were cancelled after the patient had entered the operation room and preparation for general anesthesia had been completed. Ten of 18 cases (55.6%) that were cancelled before general anesthesia induction could have been prevented, accounting for 36.7% of the overall cancellations. The majority of the cancellations after anesthesia were due to the patients’ health status. Improving the systems for checking patients’ medical problems and performing preoperative evaluations can reduce the number of cancellations after the patient has entered the operating room.
- Open Access
- 15 January 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 2
A case of unexpectedly difficult intubation caused by a large asymptomatic choanal polyp
We report a case of unexpectedly difficult intubation in a patient with a huge but asymptomatic choanal polyp. A 77-year-old man with invasive bladder cancer was scheduled for total cystectomy under general anesthesia. However, tracheal intubation with a Macintosh laryngoscope proved impossible due to obstruction by a large oropharyngeal tumor. Using a video laryngoscope, intubation was successfully achieved. Choanal polyps are not uncommon, but large choanal polyps reaching the oropharynx appear relatively rare. Anesthesia and airway management for large oropharyngeal tumor has not been sufficiently discussed.
- 15 January 2016
- Published by Springer Nature in JA Clinical Reports
- Vol. 2 (1) , 2
Open AccessA case of unexpectedly difficult intubation caused by a large asymptomatic choanal polyp
We report a case of unexpectedly difficult intubation in a patient with a huge but asymptomatic choanal polyp. A 77-year-old man with invasive bladder cancer was scheduled for total cystectomy under general anesthesia. However, tracheal intubation with a Macintosh laryngoscope proved impossible due to obstruction by a large oropharyngeal tumor. Using a video laryngoscope, intubation was successfully achieved. Choanal polyps are not uncommon, but large choanal polyps reaching the oropharynx appear relatively rare. Anesthesia and airway management for large oropharyngeal tumor has not been sufficiently discussed.
- Open Access
- 25 September 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 82
Gastric tube insertion under direct vision using the King Vision™ video laryngoscope: a randomized, prospective, clinical trial
The frequency of malpositioning of gastric tubes in the trachea has been reported to be 0.3–15%, which may cause severe complications, such as pneumonia, if not detected promptly. If a gastric tube can be guided into the esophagus under direct vision with a video laryngoscope, misplacement of the gastric tube into the trachea can be avoided. We compared gastric tube insertion under direct vision using a video laryngoscope with the conventional method of blind insertion. We enrolled 60 patients who required a transnasal gastric tube to facilitate elective abdominal surgery under general anesthesia. The participants were recruited consecutively into one of two groups, a group of 30 patients in whom a gastric tube was inserted using a King Vision™ video laryngoscope (KV group), and a group of 30 patients who underwent conventional blind insertion of the gastric tube (Blind group). The success rate, the time taken to insert the gastric tube, and the incidence of complications were compared. In the KV group, the time required for gastric tube placement was 52.5 ± 17.1 seconds, with a success rate of 100%. Slight oral hemorrhage occurred in two participants and slight epistaxis in one participant. In the Blind group, the time required for gastric tube placement was 65.9 ± 39.9 seconds, with a success rate of 90% (27 out of 30 patients). Slight oral hemorrhage occurred in two participants, slight epistaxis occurred in two participants, and tracheal malposition occurred in one participant but was detected promptly and corrected using the video laryngoscope. There were no significant differences in the time required for placing the gastric tube, the success rate, or the incidence of complications between the groups. Gastric tube insertion using a King Vision video laryngoscope was straightforward, and was particularly useful for detecting and correcting tracheal malpositioning. Trial registry number: UMIN000011014 .
- 25 September 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 82
Open AccessGastric tube insertion under direct vision using the King Vision™ video laryngoscope: a randomized, prospective, clinical trial
The frequency of malpositioning of gastric tubes in the trachea has been reported to be 0.3–15%, which may cause severe complications, such as pneumonia, if not detected promptly. If a gastric tube can be guided into the esophagus under direct vision with a video laryngoscope, misplacement of the gastric tube into the trachea can be avoided. We compared gastric tube insertion under direct vision using a video laryngoscope with the conventional method of blind insertion. We enrolled 60 patients who required a transnasal gastric tube to facilitate elective abdominal surgery under general anesthesia. The participants were recruited consecutively into one of two groups, a group of 30 patients in whom a gastric tube was inserted using a King Vision™ video laryngoscope (KV group), and a group of 30 patients who underwent conventional blind insertion of the gastric tube (Blind group). The success rate, the time taken to insert the gastric tube, and the incidence of complications were compared. In the KV group, the time required for gastric tube placement was 52.5 ± 17.1 seconds, with a success rate of 100%. Slight oral hemorrhage occurred in two participants and slight epistaxis in one participant. In the Blind group, the time required for gastric tube placement was 65.9 ± 39.9 seconds, with a success rate of 90% (27 out of 30 patients). Slight oral hemorrhage occurred in two participants, slight epistaxis occurred in two participants, and tracheal malposition occurred in one participant but was detected promptly and corrected using the video laryngoscope. There were no significant differences in the time required for placing the gastric tube, the success rate, or the incidence of complications between the groups. Gastric tube insertion using a King Vision video laryngoscope was straightforward, and was particularly useful for detecting and correcting tracheal malpositioning. Trial registry number: UMIN000011014 .