Jürgen Schmidt
Jürgen Schmidt has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jens Denecke
CSE Center of Safety Excellence (CSE-Institut), Joseph-von-Fraunhofer-Str. 9, 76327 Pfinztal, Germany
2 shared publications - Deniz Quick
CSE Center of Safety Excellence (CSE-Institut), 76327 Pfinztal, Germany
1 shared publication - Hans-Peter Schildberg
BASF SE, Safety Engineering, Ludwigshafen 67056, Germany
1 shared publication - Matthias Müller
Hochschule Karlsruhe - University of Applied Sciences, Karlsruhe 76133, Germany; Pfinztal 76327, Germany
1 shared publication - Otto-Ernst Bernhardi
Hochschule Karlsruhe - University of Applied Sciences, Karlsruhe 76133, Germany
1 shared publication
Latest Publications
- Open Access
Enhancing Acoustic Leak Detection with Data Augmentation: Overcoming Background Noise Challenges
A leak detection method is developed for leaks typically encountered in industrial production. Leaks of 1 mm diameter and less are considered at operating pressures up to 10 bar. The system uses two separate datasets—one for the leak noises and the other for the background noises—both are linked using a developed mixup technique and thus simulate leaks trained in background noises. A specific frequency window between 11 and 20 kHz is utilized to generate a quadratic input for image recognition. With this method, detection accuracies of over 95% with a false alarm rate under 2% can be achieved on a test dataset under the background noises of hydraulic machines in laboratory conditions.
Open AccessEnhancing Acoustic Leak Detection with Data Augmentation: Overcoming Background Noise Challenges
A leak detection method is developed for leaks typically encountered in industrial production. Leaks of 1 mm diameter and less are considered at operating pressures up to 10 bar. The system uses two separate datasets—one for the leak noises and the other for the background noises—both are linked using a developed mixup technique and thus simulate leaks trained in background noises. A specific frequency window between 11 and 20 kHz is utilized to generate a quadratic input for image recognition. With this method, detection accuracies of over 95% with a false alarm rate under 2% can be achieved on a test dataset under the background noises of hydraulic machines in laboratory conditions.
- 8 April 2024
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 146 (3) , 1-52
Analysis of Plastic Deformation of Pipes Due to Deflagration to Detonation Transition Using Static Equivalent Pressure
Explosions of premixed gases with deflagration to detonation transition (DDT) are a risk in the process industry with potentially catastrophic consequences. Robust and simple design methods are required for industrial use. Such a simplified design method based on finite element analysis is proposed to model the dynamic behavior of pipes loaded by gas explosions of premixed gases including DDT. The focus is on so-called long pipes, where the DDT is not affected by reflections at blind flanges. First, it is reviewed how the pressure load of the gas explosion and the resulting material behavior has been modeled in previous publications. The analytical equations are then extended for describing the pressure load as a function of time and location by considering the leading compression wave as it affects the pressure load of the overdriven detonation. The extended analytical equations are parameterized using Chapman-Jouguet conditions and experimental results from publications for both static equivalent pressure and the location of the DDT. To describe the plastic material behavior at high strain rates, the well-known Johnson-Cook plasticity model is used. The material parameters of the model are derived from simple experiments, which are available in an industrial environment. The comparison of a finite element simulation with experimental data shows that the concept of equivalent static pressure can be extended to an finite element analysis, which in the future will allow the sizing of complete pipe systems including tees, bends, and flanges while considering plastic deformation.
- 8 April 2024
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 146 (3) , 1-52
Analysis of Plastic Deformation of Pipes Due to Deflagration to Detonation Transition Using Static Equivalent Pressure
Explosions of premixed gases with deflagration to detonation transition (DDT) are a risk in the process industry with potentially catastrophic consequences. Robust and simple design methods are required for industrial use. Such a simplified design method based on finite element analysis is proposed to model the dynamic behavior of pipes loaded by gas explosions of premixed gases including DDT. The focus is on so-called long pipes, where the DDT is not affected by reflections at blind flanges. First, it is reviewed how the pressure load of the gas explosion and the resulting material behavior has been modeled in previous publications. The analytical equations are then extended for describing the pressure load as a function of time and location by considering the leading compression wave as it affects the pressure load of the overdriven detonation. The extended analytical equations are parameterized using Chapman-Jouguet conditions and experimental results from publications for both static equivalent pressure and the location of the DDT. To describe the plastic material behavior at high strain rates, the well-known Johnson-Cook plasticity model is used. The material parameters of the model are derived from simple experiments, which are available in an industrial environment. The comparison of a finite element simulation with experimental data shows that the concept of equivalent static pressure can be extended to an finite element analysis, which in the future will allow the sizing of complete pipe systems including tees, bends, and flanges while considering plastic deformation.
- 14 November 2019
- Published by Springer Nature
- p. 1487-1519
L2.4 Kritische Massenströme durch Düsen, Ventile und Rohreinbauten
- 14 November 2019
- Published by Springer Nature
- p. 1487-1519
L2.4 Kritische Massenströme durch Düsen, Ventile und Rohreinbauten
- 14 November 2019
- Published by Springer Nature
- p. 1469-1485
L2.3 Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate
- 14 November 2019
- Published by Springer Nature
- p. 1469-1485
L2.3 Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate
- 5 October 2018
- Published by Springer Nature
- p. 1-34
Kritische Massenströme durch Düsen, Ventile und Rohreinbauten
- 5 October 2018
- Published by Springer Nature
- p. 1-34
Kritische Massenströme durch Düsen, Ventile und Rohreinbauten
- 29 August 2018
- Published by Springer Nature
- p. 1-17
Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate
- 29 August 2018
- Published by Springer Nature
- p. 1-17
Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate