Nils Roar Gjerdet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nils Roar Gjerdet has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Amanda S. Pellowe
School of Engineering and Applied Sciences, Yale University, New Haven, CT 06511, USA
1 shared publication - Anneli Skjold
Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Aarstadveien 19, Bergen N-5009, Norway
1 shared publication - Astvaldur J. Arthursson
Department of Orthopaedic Surgery, Stavanger University Hospital, Stavanger, Norway
1 shared publication - Cathrine H. Enoksen
Department of Orthopaedic Surgery, Stavanger University Hospital, Stavanger, Norway
1 shared publication - Christian Schriwer
Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Aarstadveien 19, Bergen N-5009, Norway
1 shared publication - Einar K. Kristoffersen
Department of Clinical Science, University of Bergen, N-5021 Bergen, Norway
1 shared publication
Latest Publications
- Open Access
- 27 August 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 125, 104271
Fractographic analysis of 35 clinically fractured bi-layered and monolithic zirconia crowns
- 27 August 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 125, 104271
Open AccessFractographic analysis of 35 clinically fractured bi-layered and monolithic zirconia crowns
- Open Access
- 6 April 2018
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 19 (4) , 1101
Novel Nanoparticulate and Ionic Titanium Antigens for Hypersensitivity Testing
Titanium is used in a wide variety of materials ranging from medical devices to materials used in everyday life. Adverse biological reactions that could occur in patients, consumers, and workers should be monitored and prevented. There is a lack of available agents to test and predict titanium-related hypersensitivity. The aim of this study was to develop two bioavailable titanium substances in ionic and nanoparticulate form to serve as antigens for hypersensitivity testing in vitro. Peripheral blood mononuclear cells from 20 test subjects were stimulated with the antigens and secretion of monocytic and lymphatic cytokines and chemokines were measured by a multiplex bead assay. Lymphocyte stimulation indices were also determined in a subset of test subjects by measuring CD69 and HLA-DR expression by flow cytometry. Cytokine profiling revealed that both antigens increased production of typical monocyte and macrophage secreted cytokines after 24 h, with significant increases in IL-1β, IL-7, IL-10, IL-12, IL-2R, IL-6, GM-CSF, TNF-α, IL-1RA, MIP-1α, MIP-1β, IFN-α, and IL-15. Lymphatic cytokines and chemokines were not significantly induced by activation. After seven days of stimulation, ionic-Ti (2.5 μg/mL) caused proliferation (stimulation index > 2) of CD4+ cells and CD8+ cells in all persons tested (N = 6), while titanium dioxide nanoparticles (50 μg/mL) only caused significant proliferation of CD4+ cells. Our preliminary results show that the experimental titanium antigens, especially the ionic form, induce a general inflammatory response in vitro. A relevant cohort of test subjects is required to further elucidate their potential for predictive hypersensitivity testing.
- 6 April 2018
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 19 (4) , 1101
Open AccessNovel Nanoparticulate and Ionic Titanium Antigens for Hypersensitivity Testing
Titanium is used in a wide variety of materials ranging from medical devices to materials used in everyday life. Adverse biological reactions that could occur in patients, consumers, and workers should be monitored and prevented. There is a lack of available agents to test and predict titanium-related hypersensitivity. The aim of this study was to develop two bioavailable titanium substances in ionic and nanoparticulate form to serve as antigens for hypersensitivity testing in vitro. Peripheral blood mononuclear cells from 20 test subjects were stimulated with the antigens and secretion of monocytic and lymphatic cytokines and chemokines were measured by a multiplex bead assay. Lymphocyte stimulation indices were also determined in a subset of test subjects by measuring CD69 and HLA-DR expression by flow cytometry. Cytokine profiling revealed that both antigens increased production of typical monocyte and macrophage secreted cytokines after 24 h, with significant increases in IL-1β, IL-7, IL-10, IL-12, IL-2R, IL-6, GM-CSF, TNF-α, IL-1RA, MIP-1α, MIP-1β, IFN-α, and IL-15. Lymphatic cytokines and chemokines were not significantly induced by activation. After seven days of stimulation, ionic-Ti (2.5 μg/mL) caused proliferation (stimulation index > 2) of CD4+ cells and CD8+ cells in all persons tested (N = 6), while titanium dioxide nanoparticles (50 μg/mL) only caused significant proliferation of CD4+ cells. Our preliminary results show that the experimental titanium antigens, especially the ionic form, induce a general inflammatory response in vitro. A relevant cohort of test subjects is required to further elucidate their potential for predictive hypersensitivity testing.
- 16 March 2017
- Published by The Norwegian Dental Journal in Den norske tannlegeforenings Tidende
- Vol. 127 (3) , 242-5
Uedle legeringer til fast protetikk
English summary: Base metal alloys for fixed prosthodontics 242-5 Cobalt-chromium alloys are now commonly used for fixed dentures and single crowns. The alloys are attractive because they are light and provide high stiffness due to their high elastic modulus (Young's modulus) compared with noble metal alloys, pure titanium or titanium alloys. Recent processing techniques, such as selective laser melting (SLM), affect the properties. The biological responses in biological laboratory tests appear to be mild. Contact allergy could be a concern in susceptible patients.
- 16 March 2017
- Published by The Norwegian Dental Journal in Den norske tannlegeforenings Tidende
- Vol. 127 (3) , 242-5
Uedle legeringer til fast protetikk
English summary: Base metal alloys for fixed prosthodontics 242-5 Cobalt-chromium alloys are now commonly used for fixed dentures and single crowns. The alloys are attractive because they are light and provide high stiffness due to their high elastic modulus (Young's modulus) compared with noble metal alloys, pure titanium or titanium alloys. Recent processing techniques, such as selective laser melting (SLM), affect the properties. The biological responses in biological laboratory tests appear to be mild. Contact allergy could be a concern in susceptible patients.
- 1 February 2016
- Published by Elsevier in Clinical Biomechanics
- Vol. 32, 28-33
Deformation pattern and load transfer of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs
- 1 February 2016
- Published by Elsevier in Clinical Biomechanics
- Vol. 32, 28-33
Deformation pattern and load transfer of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs