MFMaria Luisa Forchielli

Maria Luisa Forchielli

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maria Luisa Forchielli has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Insulin Instability in Parenteral Nutrition Admixtures

    by Maria Luisa Forchielli, Franco Bongiovanni, Livia Platé, Giulia Piazza, Cristina Puggioli, Antonietta D'Alise, Germana Bersani

    Background: Biosynthetic human recombinant short‐acting insulin is added to parenteral nutrition (PN) admixtures to nourish glucose‐intolerant patients. Insulin, however, is electrostatically attracted and inactivated by ethyl‐vinyl‐acetate (EVA) bags and filling system tubes. Our aim was to verify and quantify the presence of insulin in PN with and without intravenous lipid emulsion (ILE), just after addition (T0) until the infusion's end (T24).Methods: Four undiluted samples of 12 different PN complete admixtures (6 with ILE and 6 without), each containing 250 g of glucose in a 2000 mL volume, were taken and analyzed at T0 and T24 by an automated electrochemiluminescence immunoassay after the addition of biosynthetic human recombinant short‐acting insulin at increasing doses (from 6 to 72 IU/bag) by an automated compounding device. Assay sensitivity was set at 2 μIU/mL. Admixtures with and without ILE were compared in terms of insulin‐detected amounts at T0 and T24.Results: Regardless of the amount initially provided, insulin was missing in PN without ILE. In admixtures with ILE, the greater the insulin and ILE doses initially included, the higher the insulin availability at T0 and T24, both in absolute terms and as a percentage of the initial amount (from 3 to 81% at T0 and from 2.5 to 72.5% at T24). ILE may prevent insulin attraction to plastic surfaces.Conclusions: Insulin is recovered in the presence of ILE in PN even though considerable amounts are untraceable. This aspect needs verification. Until then, insulin should safely be injected in a different manner in uncontrolled situations.


  • Potential intake of vitamins “A” and “D” through branded intravenous lipid emulsions: Liquid Chromatography-Tandem Mass Spectrometry Analysis

    by Maria Luisa Forchielli, Matteo Conti, Daniela Patrono, Rita Mancini, Andrea Pession, Cristina Puggioli, Germana Bersani


  • Pediatric parenteral admixture compounding in a highly specialized university hospital

    by Germana Bersani, Alessandra Stancari, Silvia Maselli, Anna Maria Guarguaglini, Lucia Loredana Bruno, Maria Luisa Forchielli, Cristina Puggioli

  • Success Rates and Cost‐Effectiveness of Antibiotic Combinations for Initial Treatment of Central‐Venous‐Line Infections During Total Parenteral Nutrition

    by M. Luisa Forchielli, Kathleen Gura, Eugenio Anessi‐Pessina, Denise Richardson, Wei Cai, Clifford W. Lo

    Background: Central‐venous‐line infections can be successfully treated with appropriate antibiotics, thus avoiding the need for catheter removal. Based on our experience, vancomycin, gentamicin, piperacillin, ceftazidime, and amphotericin, alone or in combination, are usually administered, pending sensitivity results. This empirical list, however, has never been verified against actual sensitivity results nor has it been tested for cost or efficacy. Methods: Medical records of inpatients on hyperalimentation over 1 year were reviewed. Success rate, therapy duration, and drug acquisition cost and charge were assessed for central‐venous‐line infections. Antibiotics then were paired and evaluated in terms of charge and efficacy against all microorganisms as determined by sensitivity results. Results: In 500 inpatients receiving hyperalimentation for 9698 patient‐days, 8.4 central‐venous‐line infections/1000 patient‐days occurred. Staphylococcus non‐aureus, Candida species, Enterococcus faecium, and Staphylococcus aureus predominantly were isolated. Of the infections, 51 (67%) were sensitive to one or more of the initial antibiotics. A 2‐week course of antibiotics successfully treated 50 (66%) catheter infections without line removal. Appropriate initial therapy on average reduced treatment duration by 8 to 10 days and drug charges by $400 to $700. Conclusions: Amikacin‐vancomycin appears to be the most cost‐effective selection for presumed central‐venous‐line infections, pending sensitivity results, followed by valid alternatives. Lower failure rates are well worth the extra cost in pharmaceutical charges. (Journal of Parenteral and Enteral Nutrition 24:119–125, 2000)