Mei Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mei Sun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Morton A. Barlaz
Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Campus Box 7908, Raleigh, North Carolina 27695-7908, United States
2 shared publications Catalina Lopez-Velandia
Department of Civil, Construction, and Environmental Engineering, North Carolina State University , Campus Box 7908, Raleigh, North Carolina 28223, United States
1 shared publication- Detlef R. U. Knappe
Department of Civil, Construction, and Environmental Engineering North Carolina State University Raleigh North Carolina USA
1 shared publication - Joel J. Ducoste
Civil, Construction and Environmental Engineering Department at North Carolina State University
1 shared publication - Wenjie Sun
Department of Civil and Environmental Engineering, Southern Methodist University, Dallas, USA
1 shared publication - Zisu Hao
Dept. of Civil, Construction, and Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States
1 shared publication
Latest Publications
- 30 March 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 281-288
A Model to Describe Heat Generation and Accumulation at Municipal Solid Waste Landfills
There have been reports of landfills in North America that are experiencing elevated temperatures that are resulting in challenging issues for landfill management. The objective of this study is to develop a box model to describe the generation, consumption and release of heat in landfills and subsequently to predict temperature profiles. Initially, a box model was developed that treats the landfill as a completely mixed system in which all relevant reactions are described. This model will make it possible to identify processes and reactions that are most significant. The model is based on thermodynamic principles and accounts for all significant heat sources and sinks in landfills. Heat sources include energy from biotic and abiotic reactions and condensation. Heat removal processes include convection of methane and carbon dioxide, infiltration, leachate collection and evaporation. The model was used to evaluate the heat generation performance of aerobic and anaerobic biodegradation of waste with and without the presence of ash (from coal or municipal solid waste). The model analysis showed that the hydration of ash can increase landfill temperature above that predicted for the disposal of municipal solid waste alone.
- 30 March 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 281-288
A Model to Describe Heat Generation and Accumulation at Municipal Solid Waste Landfills
There have been reports of landfills in North America that are experiencing elevated temperatures that are resulting in challenging issues for landfill management. The objective of this study is to develop a box model to describe the generation, consumption and release of heat in landfills and subsequently to predict temperature profiles. Initially, a box model was developed that treats the landfill as a completely mixed system in which all relevant reactions are described. This model will make it possible to identify processes and reactions that are most significant. The model is based on thermodynamic principles and accounts for all significant heat sources and sinks in landfills. Heat sources include energy from biotic and abiotic reactions and condensation. Heat removal processes include convection of methane and carbon dioxide, infiltration, leachate collection and evaporation. The model was used to evaluate the heat generation performance of aerobic and anaerobic biodegradation of waste with and without the presence of ash (from coal or municipal solid waste). The model analysis showed that the hydration of ash can increase landfill temperature above that predicted for the disposal of municipal solid waste alone.
- 1 May 2016
- Published by Elsevier in Science of The Total Environment
- Vol. 551-552, 23-31
A batch assay to measure microbial hydrogen sulfide production from sulfur-containing solid wastes
- 1 May 2016
- Published by Elsevier in Science of The Total Environment
- Vol. 551-552, 23-31
A batch assay to measure microbial hydrogen sulfide production from sulfur-containing solid wastes
- 15 February 2016
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 50 (5) , 2246-2254
Determination of 1,4-Dioxane in the Cape Fear River Watershed by Heated Purge-and-Trap Preconcentration and Gas Chromatography–Mass Spectrometry
Recent U.S. Environmental Protection Agency data show that 1,4-dioxane is frequently detected in U.S. drinking water derived from both groundwater and surface water. 1,4-Dioxane is a likely human carcinogen, and an excess 10–6 cancer risk is associated with a drinking water concentration of 0.35 μg/L. To support 1,4-dioxane occurrence investigations, source identification and exposure assessment, a rapid and sensitive analytical method capable of quantifying 1,4-dioxane over a wide concentration range in a broad spectrum of aqueous matrices was developed. The fully automated method is based on heated purge-and-trap preconcentration and gas chromatography/mass spectrometry with selected-ion storage and has a reporting limit of 0.15 μg/L. Quantification of 1,4-dioxane was accomplished by isotope dilution using mass-labeled 1,4-dioxane-d8 as internal standard. Matrix spikes yielded recoveries of 86–115% in drinking water, groundwater, surface water, and wastewater treatment plant (WWTP) effluent. Also, 1,3-dioxane can be distinguished from 1,4-dioxane. The method was applied to investigate 1,4-dioxane occurrence and sources in the Cape Fear River watershed of North Carolina. 1,4-Dioxane concentrations ranged from <0.15 μg/L in nonimpacted surface water to 436 μg/L downstream of a WWTP discharge. In WWTP effluent, 1,4-dioxane concentrations varied widely, with a range of 1.3–2.7 μg/L in one community and 105–1,405 μg/L in another. Discharges from three municipal WWTPs were primarily responsible for elevated 1,4-dioxane concentrations in the Cape Fear River watershed.
- 15 February 2016
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 50 (5) , 2246-2254
Determination of 1,4-Dioxane in the Cape Fear River Watershed by Heated Purge-and-Trap Preconcentration and Gas Chromatography–Mass Spectrometry
Recent U.S. Environmental Protection Agency data show that 1,4-dioxane is frequently detected in U.S. drinking water derived from both groundwater and surface water. 1,4-Dioxane is a likely human carcinogen, and an excess 10–6 cancer risk is associated with a drinking water concentration of 0.35 μg/L. To support 1,4-dioxane occurrence investigations, source identification and exposure assessment, a rapid and sensitive analytical method capable of quantifying 1,4-dioxane over a wide concentration range in a broad spectrum of aqueous matrices was developed. The fully automated method is based on heated purge-and-trap preconcentration and gas chromatography/mass spectrometry with selected-ion storage and has a reporting limit of 0.15 μg/L. Quantification of 1,4-dioxane was accomplished by isotope dilution using mass-labeled 1,4-dioxane-d8 as internal standard. Matrix spikes yielded recoveries of 86–115% in drinking water, groundwater, surface water, and wastewater treatment plant (WWTP) effluent. Also, 1,3-dioxane can be distinguished from 1,4-dioxane. The method was applied to investigate 1,4-dioxane occurrence and sources in the Cape Fear River watershed of North Carolina. 1,4-Dioxane concentrations ranged from <0.15 μg/L in nonimpacted surface water to 436 μg/L downstream of a WWTP discharge. In WWTP effluent, 1,4-dioxane concentrations varied widely, with a range of 1.3–2.7 μg/L in one community and 105–1,405 μg/L in another. Discharges from three municipal WWTPs were primarily responsible for elevated 1,4-dioxane concentrations in the Cape Fear River watershed.