Stina Jorstig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stina Jorstig has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Micael Waldenborg
School of Medical Sciences, Faculty of Medicine and Health, Örebro University, 70182, Örebro, Sweden
2 shared publications - Per Thunberg
Department of Medical Physics, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
2 shared publications Maciej Wodecki
Department of Clinical Physiology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
1 shared publicationMats Lidén
School of Health and Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
1 shared publication- Mats Lidén
Department of Radiology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
1 shared publication
Latest Publications
- Open Access
- 7 March 2017
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 15 (1) , 1-9
Right ventricular ejection fraction measurements using two-dimensional transthoracic echocardiography by applying an ellipsoid model
There is today no established approach to estimate right ventricular ejection fraction (RVEF) using 2D transthoracic echocardiography (TTE). The aim of this study was to evaluate a new method for RVEF calculations using 2D TTE and compare the results with cardiac magnetic resonance (CMR) imaging and tricuspid annular plane systolic excursion (TAPSE). A total of 37 subjects, 25 retrospectively included patients and twelve healthy volunteers, were included to give a wide range of RVEF. The right ventricle (RV) was modeled as a part of an ellipsoid enabling calculation of the RV volume by combining three distance measurements. RVEF calculated according to the model, RVEFTTE, were compared with reference CMR-derived RVEF, RVEFCMR. Further, TAPSE was measured in the TTE images and the correlations were calculated between RVEFTTE, TAPSE and RVEFCMR. The mean values were RVEFCMR = 43 ± 12% (range 20–66%) and RVEFTTE = 50 ± 9% (range 34–65%). There was a high correlation (r = 0.80, p < 0.001) between RVEFTTE and RVEFCMR. Bland-Altman analysis showed a mean difference between RVEFCMR and RVEFTTE of 6 percentage points (ppt) with limits of agreement from −11 to 23 ppt. The mean value for TAPSE was 19 ± 5 mm and the correlation between TAPSE and RVEFCMR was moderate (r = 0.54, p < 0.001). The correlation between RVEFTTE and RVEFCMR was significantly higher (p < 0.05) than the correlation between TAPSE and RVEFCMR. The ellipsoid model shows promise for RVEF calculations using 2D TTE for a wide range of RVEF, providing RVEF estimates that were significantly better correlated to RVEF obtained from CMR compared to TAPSE.
- 7 March 2017
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 15 (1) , 1-9
Open AccessRight ventricular ejection fraction measurements using two-dimensional transthoracic echocardiography by applying an ellipsoid model
There is today no established approach to estimate right ventricular ejection fraction (RVEF) using 2D transthoracic echocardiography (TTE). The aim of this study was to evaluate a new method for RVEF calculations using 2D TTE and compare the results with cardiac magnetic resonance (CMR) imaging and tricuspid annular plane systolic excursion (TAPSE). A total of 37 subjects, 25 retrospectively included patients and twelve healthy volunteers, were included to give a wide range of RVEF. The right ventricle (RV) was modeled as a part of an ellipsoid enabling calculation of the RV volume by combining three distance measurements. RVEF calculated according to the model, RVEFTTE, were compared with reference CMR-derived RVEF, RVEFCMR. Further, TAPSE was measured in the TTE images and the correlations were calculated between RVEFTTE, TAPSE and RVEFCMR. The mean values were RVEFCMR = 43 ± 12% (range 20–66%) and RVEFTTE = 50 ± 9% (range 34–65%). There was a high correlation (r = 0.80, p < 0.001) between RVEFTTE and RVEFCMR. Bland-Altman analysis showed a mean difference between RVEFCMR and RVEFTTE of 6 percentage points (ppt) with limits of agreement from −11 to 23 ppt. The mean value for TAPSE was 19 ± 5 mm and the correlation between TAPSE and RVEFCMR was moderate (r = 0.54, p < 0.001). The correlation between RVEFTTE and RVEFCMR was significantly higher (p < 0.05) than the correlation between TAPSE and RVEFCMR. The ellipsoid model shows promise for RVEF calculations using 2D TTE for a wide range of RVEF, providing RVEF estimates that were significantly better correlated to RVEF obtained from CMR compared to TAPSE.
- 3 February 2016
- Published by Wiley in Echocardiography
- Vol. 33 (6) , 844-853
Determination of Right Ventricular Volume by Combining Echocardiographic Distance Measurements
Background: The position of the right ventricle (RV), often partly behind the sternum, implies difficulties to image the RV free wall using transthoracic echocardiography (TTE) and consequently limits the possibilities of stroke volume calculations. The aim of this study was to evaluate whether the volume of the right ventricle (RV) can be determined by combining TTE distance measurements that do not need the RV free wall to be fully visualized.Methods: The RV volume was approximated by an ellipsoid composed of three distances. Distance measurements, modeled RV stroke volumes (RVSV), and RV ejection fraction (RVEF) were compared to reference values obtained from cardiac magnetic resonance (CMR) imaging for 12 healthy volunteers.Results: Inter‐modality comparisons showed that distance measurements were significantly underestimated in TTE compared to CMR. The modeled RV volumes using TTE distance measurements were underestimated compared to reference CMR volumes. There was, however, for TTE an agreement between modeled RVSV and left ventricular stroke volumes determined by biplane Simpson's rule. Similar agreement was shown between modeled RVSV based on CMR distance measurements and the CMR reference. Regarding RVEF, further studies including patients with a wider range of RVEF are needed to evaluate the method.Conclusion: In conclusion, the ellipsoid model of the RV provides good estimates of RVSVs, but volumes based on distance measurements from different modalities cannot be used interchangeably.
- 3 February 2016
- Published by Wiley in Echocardiography
- Vol. 33 (6) , 844-853
Determination of Right Ventricular Volume by Combining Echocardiographic Distance Measurements
Background: The position of the right ventricle (RV), often partly behind the sternum, implies difficulties to image the RV free wall using transthoracic echocardiography (TTE) and consequently limits the possibilities of stroke volume calculations. The aim of this study was to evaluate whether the volume of the right ventricle (RV) can be determined by combining TTE distance measurements that do not need the RV free wall to be fully visualized.Methods: The RV volume was approximated by an ellipsoid composed of three distances. Distance measurements, modeled RV stroke volumes (RVSV), and RV ejection fraction (RVEF) were compared to reference values obtained from cardiac magnetic resonance (CMR) imaging for 12 healthy volunteers.Results: Inter‐modality comparisons showed that distance measurements were significantly underestimated in TTE compared to CMR. The modeled RV volumes using TTE distance measurements were underestimated compared to reference CMR volumes. There was, however, for TTE an agreement between modeled RVSV and left ventricular stroke volumes determined by biplane Simpson's rule. Similar agreement was shown between modeled RVSV based on CMR distance measurements and the CMR reference. Regarding RVEF, further studies including patients with a wider range of RVEF are needed to evaluate the method.Conclusion: In conclusion, the ellipsoid model of the RV provides good estimates of RVSVs, but volumes based on distance measurements from different modalities cannot be used interchangeably.