Hua Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hua Liang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Like Xie
Science and Technology on Plasma Dynamics Laboratory, Air Force Engineering University, Xi'an 710038, China
3 shared publications - Zhi Su
Aeronautical Engineering College, Air Force Engineering University, Xi’an 710038, China
3 shared publications - Biao Wei
Aeronautical Engineering College, Air Force Engineering University, Xi’an 710038, China
2 shared publications - Yuhao Jia
College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
2 shared publications - Zhong-Guo Niu
Science and Technology on Plasma Dynamics Laboratory, Air Force Engineering University 1 , Xi’an 710038, China
2 shared publications Bing-Liang Tang
Air Force Engn Univ, Sci & Technol Plasma Dynam Lab, Xian 710038, Peoples R China
1 shared publication
Latest Publications
- 10 November 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (12) , 125503
Parametric study of high-frequency characteristics of plasma synthetic jet actuator
A major issue of plasma synthetic jet actuator (PSJA) is the severe performance deterioration at high working frequency. In this study, experiments and numerical simulation are combined together to investigate the influence of thermal conductivity, throat length (L th) and discharge duration (T d) on the high-frequency characteristics of PSJA. Results show that the variation of the actuator thermal conductivity and discharge duration will not alter the saturation frequency of the actuator, whereas decreasing the throat length results in an increase of the saturation frequency. For a short-duration capacitive discharge of 1.7 μs, a clear shock wave is issued from the orifice, followed by a weak jet. As a comparison, when the discharge duration is increased up to 202.6 μs, a strong jet column is formed and no obvious shock wave can be visualized. Based on numerical simulation results, it becomes clear that the long-duration pulse-DC discharge is able to heat the cavity gas to a much higher temperature (3141 K) than capacitive discharge, greatly improving the conversion efficiency of the arc discharge energy to the internal energy of the cavity gas. In addition, high-speed Schlieren imaging is deployed to study the performance degradation mechanism of PSJA at high working frequency. Monitor of the exit jet grayscale indicates that as long as the saturation frequency is exceeded, the actuator becomes unstable due to insufficient refresh time. The higher the discharge frequency, the more frequently the phenomenon of ‘misfires’ will occur, which explains well the decaying jet total pressure at above saturation frequency.
- 10 November 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (12) , 125503
Parametric study of high-frequency characteristics of plasma synthetic jet actuator
A major issue of plasma synthetic jet actuator (PSJA) is the severe performance deterioration at high working frequency. In this study, experiments and numerical simulation are combined together to investigate the influence of thermal conductivity, throat length (L th) and discharge duration (T d) on the high-frequency characteristics of PSJA. Results show that the variation of the actuator thermal conductivity and discharge duration will not alter the saturation frequency of the actuator, whereas decreasing the throat length results in an increase of the saturation frequency. For a short-duration capacitive discharge of 1.7 μs, a clear shock wave is issued from the orifice, followed by a weak jet. As a comparison, when the discharge duration is increased up to 202.6 μs, a strong jet column is formed and no obvious shock wave can be visualized. Based on numerical simulation results, it becomes clear that the long-duration pulse-DC discharge is able to heat the cavity gas to a much higher temperature (3141 K) than capacitive discharge, greatly improving the conversion efficiency of the arc discharge energy to the internal energy of the cavity gas. In addition, high-speed Schlieren imaging is deployed to study the performance degradation mechanism of PSJA at high working frequency. Monitor of the exit jet grayscale indicates that as long as the saturation frequency is exceeded, the actuator becomes unstable due to insufficient refresh time. The higher the discharge frequency, the more frequently the phenomenon of ‘misfires’ will occur, which explains well the decaying jet total pressure at above saturation frequency.
- 26 October 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (5) , 055201
Flow separation control in S-shaped ∼inlet with a nanosecond pulsed surface dielectric barrier discharge plasma actuator
A nanosecond pulsed surface dielectric barrier discharge (nSDBD) plasma actuator is proposed to eliminate the complex 3D flow separation in an S-shaped ∼engine inlet. A set of wind tunnel experiments based on pressure measurements are conducted to verify the flow control effectiveness and obtain the influence laws of actuation voltage, pulse frequency, actuator layout and coverage area. The results show that nSDBD can effectively eliminate flow separation, leading to a noticeable improvement in the total pressure distribution at the outlet, manifested as a reduction in the low-pressure zone and an extension of the high-pressure zone. The spanwise layout nSDBD delivers a better flow control effect compared to the streamwise layout. For the same geometrical layout, the flow control effect improves with increasing voltage, and the optimal actuation frequency corresponds to a Strouhal number of approximately F + = 0.5. In particular, with a spanwise array of nSDBD plasma actuators operating at V p-p = 10 kV and F + = 0.5, the flow separation region is completely suppressed. The mechanism of flow separation with nSDBD can be ascribed to the mixing enhancement between the boundary layer and the main flow, which improves the boundary layer’s ability to resist the adverse pressure gradient.
- 26 October 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (5) , 055201
Flow separation control in S-shaped ∼inlet with a nanosecond pulsed surface dielectric barrier discharge plasma actuator
A nanosecond pulsed surface dielectric barrier discharge (nSDBD) plasma actuator is proposed to eliminate the complex 3D flow separation in an S-shaped ∼engine inlet. A set of wind tunnel experiments based on pressure measurements are conducted to verify the flow control effectiveness and obtain the influence laws of actuation voltage, pulse frequency, actuator layout and coverage area. The results show that nSDBD can effectively eliminate flow separation, leading to a noticeable improvement in the total pressure distribution at the outlet, manifested as a reduction in the low-pressure zone and an extension of the high-pressure zone. The spanwise layout nSDBD delivers a better flow control effect compared to the streamwise layout. For the same geometrical layout, the flow control effect improves with increasing voltage, and the optimal actuation frequency corresponds to a Strouhal number of approximately F + = 0.5. In particular, with a spanwise array of nSDBD plasma actuators operating at V p-p = 10 kV and F + = 0.5, the flow separation region is completely suppressed. The mechanism of flow separation with nSDBD can be ascribed to the mixing enhancement between the boundary layer and the main flow, which improves the boundary layer’s ability to resist the adverse pressure gradient.
- 14 September 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (11) , 115502
Experimental study on dynamic stall control based on AC-DBD actuation
- 14 September 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (11) , 115502
Experimental study on dynamic stall control based on AC-DBD actuation
- 2 February 2021
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 107 (3) , 631-651
Flow Separation Control of Nacelle in Crosswind by Microsecond Pulsed Surface Dielectric Barrier Discharge Plasma Actuator
- 2 February 2021
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 107 (3) , 631-651
Flow Separation Control of Nacelle in Crosswind by Microsecond Pulsed Surface Dielectric Barrier Discharge Plasma Actuator
- 5 October 2020
- Published by Wiley in Contributions to Plasma Physics
- Vol. 61 (2) , e202000067
Experimental study on high‐energy surface arc plasma excitation control of cylindrical detached shock wave
In this study, an electrical parameter test system and a high‐speed Schlieren system are used to study the control of a cylindrical detached shock wave through high‐energy surface arc plasma excitation. The results show that, when plasma excitation is not applied, the bow shockwave angle around the cylinder is 52°. After the plasma excitation is applied, the arc discharge releases a large amount of heat within a short time, generating a shockwave and a control gas bulb (CGB). As a result, the bow shockwave angle first decreases and then increases, the pressure ratio before and after the shockwave decreases, and the intensity of the bow shockwave weakens. At t = 280 μs, the bow shockwave angle is reduced to a minimum of 46°. The effective interference time of high‐energy surface arc plasma excitation on a cylindrical detached shockwave is 820 μs. A high temperature is used to control the heating effect of the bubbles, which will increase the local sound velocity near the wall, reduce the local Mach number, cause the sound velocity to move online, and eventually push the bow shockwave away from the cylinder. Concurrently, heating will accelerate the gas flow, reduce the pressure, and cause the mass flow in the unit flow area of the heated area to decrease, resulting in a strong compression effect, which deforms the bow shockwave. The high‐energy surface arc plasma excitation will provide a potential technical means for high‐speed aircraft detached shockwave control.
- 5 October 2020
- Published by Wiley in Contributions to Plasma Physics
- Vol. 61 (2) , e202000067
Experimental study on high‐energy surface arc plasma excitation control of cylindrical detached shock wave
In this study, an electrical parameter test system and a high‐speed Schlieren system are used to study the control of a cylindrical detached shock wave through high‐energy surface arc plasma excitation. The results show that, when plasma excitation is not applied, the bow shockwave angle around the cylinder is 52°. After the plasma excitation is applied, the arc discharge releases a large amount of heat within a short time, generating a shockwave and a control gas bulb (CGB). As a result, the bow shockwave angle first decreases and then increases, the pressure ratio before and after the shockwave decreases, and the intensity of the bow shockwave weakens. At t = 280 μs, the bow shockwave angle is reduced to a minimum of 46°. The effective interference time of high‐energy surface arc plasma excitation on a cylindrical detached shockwave is 820 μs. A high temperature is used to control the heating effect of the bubbles, which will increase the local sound velocity near the wall, reduce the local Mach number, cause the sound velocity to move online, and eventually push the bow shockwave away from the cylinder. Concurrently, heating will accelerate the gas flow, reduce the pressure, and cause the mass flow in the unit flow area of the heated area to decrease, resulting in a strong compression effect, which deforms the bow shockwave. The high‐energy surface arc plasma excitation will provide a potential technical means for high‐speed aircraft detached shockwave control.
- 1 October 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (10) , 105204
Influence of low ambient pressure on the performance of a high-energy array surface arc plasma actuator
In order to solve the problem of single arc plasma actuator’s failure to suppress the boundary layer separation, the effectiveness of the array surface arc plasma actuator to enhance the excitation intensity is verified by experiment. In this study, an electrical parameter measurement system and high-speed schlieren technology were adopted to delve into the electrical, flow field, and excitation characteristics of the high-energy array surface arc plasma actuator under low ambient pressure. The high-energy array surface arc discharge released considerable heat rapidly; as a result, two characteristic structures were generated, i.e., the precursor shock wave and thermal deposition area. The duration increased with the increase in environmental pressure. The lower the pressure, the wider the thermal deposition area’s influence range. The precursor shock wave exhibited a higher propagation speed at the initial phase of discharge; it tended to decay over time and finally remained at 340 m/s. The lower the environmental pressure, the higher the speed would be at the initial phase. High-energy array surface arc plasma actuator can be employed to achieve effective high-speed aircraft flow control.
- 1 October 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (10) , 105204
Influence of low ambient pressure on the performance of a high-energy array surface arc plasma actuator
In order to solve the problem of single arc plasma actuator’s failure to suppress the boundary layer separation, the effectiveness of the array surface arc plasma actuator to enhance the excitation intensity is verified by experiment. In this study, an electrical parameter measurement system and high-speed schlieren technology were adopted to delve into the electrical, flow field, and excitation characteristics of the high-energy array surface arc plasma actuator under low ambient pressure. The high-energy array surface arc discharge released considerable heat rapidly; as a result, two characteristic structures were generated, i.e., the precursor shock wave and thermal deposition area. The duration increased with the increase in environmental pressure. The lower the pressure, the wider the thermal deposition area’s influence range. The precursor shock wave exhibited a higher propagation speed at the initial phase of discharge; it tended to decay over time and finally remained at 340 m/s. The lower the environmental pressure, the higher the speed would be at the initial phase. High-energy array surface arc plasma actuator can be employed to achieve effective high-speed aircraft flow control.
- Open Access
- 1 December 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (12) , 125120
Flying wing flow separation control by microsecond pulsed dielectric barrier discharge at high Reynolds number
In this study, a microsecond pulsed dielectric barrier discharge (μs-DBD) plasma actuator is utilized to improve the aerodynamic performance of a flying wing. The wind tunnel experiments were conducted by the μs-DBD plasma actuator at a high Reynolds number (Re = 2.61 × 106). The effects of discharge position and pulse frequency on the flow control performance were studied by force measurements. The particle image velocimetry test was used to reveal the influence of plasma actuation on the detailed velocity field at the suction side of the flying wing. Results show that plasma actuation can significantly improve the aerodynamic performance of the flying wing under high Reynolds number. The best flow control effect is obtained when the plasma actuator is mounted near stagnation point (0.1% C). There is an optimal excitation frequency (100 Hz) at Re = 2.61 × 106 (corresponding to the wind speed of 70 m/s), at which the flow instability can be effectively excited. In the optimal situation, the relative improvement of the maximum lift coefficient reaches 20.51% and the stall angle is delayed by 6°. The flow control performance is mainly achieved at the outer part of the wing because the flow separation develops gradually from the wing tip to the root. These experimental results contribute to the free flight test in the wind tunnel and the flight test in real air conditions.
- 1 December 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (12) , 125120
Open AccessFlying wing flow separation control by microsecond pulsed dielectric barrier discharge at high Reynolds number
In this study, a microsecond pulsed dielectric barrier discharge (μs-DBD) plasma actuator is utilized to improve the aerodynamic performance of a flying wing. The wind tunnel experiments were conducted by the μs-DBD plasma actuator at a high Reynolds number (Re = 2.61 × 106). The effects of discharge position and pulse frequency on the flow control performance were studied by force measurements. The particle image velocimetry test was used to reveal the influence of plasma actuation on the detailed velocity field at the suction side of the flying wing. Results show that plasma actuation can significantly improve the aerodynamic performance of the flying wing under high Reynolds number. The best flow control effect is obtained when the plasma actuator is mounted near stagnation point (0.1% C). There is an optimal excitation frequency (100 Hz) at Re = 2.61 × 106 (corresponding to the wind speed of 70 m/s), at which the flow instability can be effectively excited. In the optimal situation, the relative improvement of the maximum lift coefficient reaches 20.51% and the stall angle is delayed by 6°. The flow control performance is mainly achieved at the outer part of the wing because the flow separation develops gradually from the wing tip to the root. These experimental results contribute to the free flight test in the wind tunnel and the flight test in real air conditions.
- Open Access
Experimental Study on Plasma Flow Control of Symmetric Flying Wing Based on Two Kinds of Scaling Models
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.
Open AccessExperimental Study on Plasma Flow Control of Symmetric Flying Wing Based on Two Kinds of Scaling Models
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.
- Open Access
- 11 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1889
Experimental Study on Anti-Icing Performance of NS-DBD Plasma Actuator
An experimental study was conducted to evaluate the anti-icing performance of NS-DBD plasma actuator under the conditions of airflow speed U = 65 m/s, ambient temperature T = −10 °C, liquid water content LWC = 0.5 g/m3, mean-volume diameter MVD = 25 μm, mainly to clarify the effect of pulse frequency and voltage amplitude of actuation on anti-icing performance. A NACA0012 airfoil model with a chord length of c = 280 mm was used in the tests. The NS-DBD plasma actuator was mounted at the front part of the airfoil. A FLIR infrared (IR) imager and CCD camera were used to record the anti-icing process of the NS-DBD plasma actuator. Two typical discharge conditions were selected for the anti-icing experiments. The first was HV-LF discharge, corresponding to discharge under higher voltage amplitude with lower pulse frequency; the second was LV-HF discharge, corresponding to discharge under lower voltage amplitude with higher pulse frequency. Results reveal that NS-DBD is a very promising method for anti-icing. With the same power consumption, the LV-HF discharge shows a better anti-icing performance compared to HV-LF discharge under the same icing conditions. In view of pulse duration and duty circle, combined with heat dissipation, it is suggested that there is a threshold frequency, corresponding to the voltage amplitude of electric actuation signal and the incoming flow condition, to achieve effective anti-icing performance.
- 11 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1889
Open AccessExperimental Study on Anti-Icing Performance of NS-DBD Plasma Actuator
An experimental study was conducted to evaluate the anti-icing performance of NS-DBD plasma actuator under the conditions of airflow speed U = 65 m/s, ambient temperature T = −10 °C, liquid water content LWC = 0.5 g/m3, mean-volume diameter MVD = 25 μm, mainly to clarify the effect of pulse frequency and voltage amplitude of actuation on anti-icing performance. A NACA0012 airfoil model with a chord length of c = 280 mm was used in the tests. The NS-DBD plasma actuator was mounted at the front part of the airfoil. A FLIR infrared (IR) imager and CCD camera were used to record the anti-icing process of the NS-DBD plasma actuator. Two typical discharge conditions were selected for the anti-icing experiments. The first was HV-LF discharge, corresponding to discharge under higher voltage amplitude with lower pulse frequency; the second was LV-HF discharge, corresponding to discharge under lower voltage amplitude with higher pulse frequency. Results reveal that NS-DBD is a very promising method for anti-icing. With the same power consumption, the LV-HF discharge shows a better anti-icing performance compared to HV-LF discharge under the same icing conditions. In view of pulse duration and duty circle, combined with heat dissipation, it is suggested that there is a threshold frequency, corresponding to the voltage amplitude of electric actuation signal and the incoming flow condition, to achieve effective anti-icing performance.
- 1 February 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (2) , 024703
Wind tunnel experiments on flow separation control of an Unmanned Air Vehicle by nanosecond discharge plasma aerodynamic actuation
- 1 February 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (2) , 024703
Wind tunnel experiments on flow separation control of an Unmanned Air Vehicle by nanosecond discharge plasma aerodynamic actuation