Elisabeth Leiss-Holzinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisabeth Leiss-Holzinger has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Christian Rankl
Research Center for Non Destructive Testing GmbH (RECENDT)
3 shared publications - Günther Hannesschläger
Research Center for Non-Destructive Testing (RECENDT)-GmbH, 4040 Linz, Austria
2 shared publications - Michael Pfleger
Research Center for Non-Destructive Testing (RECENDT) GmbH, Altenberger Strasse 66a, 4040 Linz, Austria
2 shared publications - Sandrine van Frank
Research Center for Non-Destructive Testing (RECENDT) GmbH, Altenberger Strasse 66a, 4040 Linz, Austria
2 shared publications - Alexandra Nemeth
RECENDT Res Ctr Non Destruct Testing GmbH, A-4040 Linz, Austria
1 shared publication - Bernhard Baumann
Medical University of Innsbruck, Institute of Biomedical Physics
1 shared publication
Latest Publications
- Open Access
In-Mould OCT Sensors Combined with Piezo-Actuated Positioning Devices for Compensating for Displacement in Injection Overmoulding of Optoelectronic Parts
When overmoulding optoelectronic devices with optical elements, precise alignment of the overmoulded part and the mould is of great importance. However, mould-integrated positioning sensors and actuators are not yet available as standard components. As a solution, we present a mould-integrated optical coherence tomography (OCT) device that is combined with a piezo-driven mechatronic actuator, which is capable of performing the necessary displacement correction. Because of the complex geometric structure optoelectronic devices may have, a 3D imaging method was preferable, so OCT was chosen. It is shown that the overall concept leads to sufficient alignment accuracy and, apart from compensating for the in-plane position error, provides valuable additional information about the sample both before and after the injection process. The increased alignment accuracy leads to better energy efficiency, improved overall performance and less scrap parts, and thus even a zero-waste production process might be feasible.
Open AccessIn-Mould OCT Sensors Combined with Piezo-Actuated Positioning Devices for Compensating for Displacement in Injection Overmoulding of Optoelectronic Parts
When overmoulding optoelectronic devices with optical elements, precise alignment of the overmoulded part and the mould is of great importance. However, mould-integrated positioning sensors and actuators are not yet available as standard components. As a solution, we present a mould-integrated optical coherence tomography (OCT) device that is combined with a piezo-driven mechatronic actuator, which is capable of performing the necessary displacement correction. Because of the complex geometric structure optoelectronic devices may have, a 3D imaging method was preferable, so OCT was chosen. It is shown that the overall concept leads to sufficient alignment accuracy and, apart from compensating for the in-plane position error, provides valuable additional information about the sample both before and after the injection process. The increased alignment accuracy leads to better energy efficiency, improved overall performance and less scrap parts, and thus even a zero-waste production process might be feasible.
- Open Access
Terahertz Time-Domain Polarimetry in Reflection for Film Characterization
Terahertz time-domain spectroscopy is a useful technique to characterize layered samples and thin films. It gives access to their optical properties and thickness. Such measurements are done in transmission, which requires access to the sample from opposite sides. In reality this is not always possible. In such cases, reflection measurements are the only option, but they are more difficult to implement. Here we propose a method to characterize films in reflection geometry using a polarimetric approach based on the identification of Brewster angle and modeling of the measured signal to extract the refractive index and thickness of the sample. The technique is demonstrated experimentally on an unsupported single layer thin film sample. The extracted optical properties and thickness were in good agreement with established transmission terahertz spectroscopy measurements. The new method has the potential to cover a wide range of applications, both for research and industrial purposes.
Open AccessTerahertz Time-Domain Polarimetry in Reflection for Film Characterization
Terahertz time-domain spectroscopy is a useful technique to characterize layered samples and thin films. It gives access to their optical properties and thickness. Such measurements are done in transmission, which requires access to the sample from opposite sides. In reality this is not always possible. In such cases, reflection measurements are the only option, but they are more difficult to implement. Here we propose a method to characterize films in reflection geometry using a polarimetric approach based on the identification of Brewster angle and modeling of the measured signal to extract the refractive index and thickness of the sample. The technique is demonstrated experimentally on an unsupported single layer thin film sample. The extracted optical properties and thickness were in good agreement with established transmission terahertz spectroscopy measurements. The new method has the potential to cover a wide range of applications, both for research and industrial purposes.
- Open Access
- 19 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 5, 19961-19970
A Localized Analysis of the Sterilization Process by Direct Steam Monitoring
Steam sterilization is a standard tool in the field of healthcare and medical equipment as it is economical, effective, and reliable. Considering the increase of antibiotic resistance and the challenge in sterilizing narrow tubes used for keyhole surgery, a safe process control is required. To achieve this, a full understanding of the local dynamics of the sterilization process inside the sterilizer is crucial. In this paper, water condensation under high temperature and high pressure, focusing on sterilization conditions, is qualitatively analyzed. An infrared sensor system was designed supplied by two LEDs, at a steam-absorbing and a non-absorbing wavelength, respectively. The local water vapor concentration was directly detected by evaluating the absorbance of infrared light as it passes through steam. Based on the absorbance monitored by this optical sensor, the condition of the steam was classified with respect to saturation and the onset of condensation. For typical sterilization cycles, differences as well as identical behavior between the local sensor measurements and the global results calculated from the temperature and pressure sensors are discussed.
- 19 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 5, 19961-19970
Open AccessA Localized Analysis of the Sterilization Process by Direct Steam Monitoring
Steam sterilization is a standard tool in the field of healthcare and medical equipment as it is economical, effective, and reliable. Considering the increase of antibiotic resistance and the challenge in sterilizing narrow tubes used for keyhole surgery, a safe process control is required. To achieve this, a full understanding of the local dynamics of the sterilization process inside the sterilizer is crucial. In this paper, water condensation under high temperature and high pressure, focusing on sterilization conditions, is qualitatively analyzed. An infrared sensor system was designed supplied by two LEDs, at a steam-absorbing and a non-absorbing wavelength, respectively. The local water vapor concentration was directly detected by evaluating the absorbance of infrared light as it passes through steam. Based on the absorbance monitored by this optical sensor, the condition of the steam was classified with respect to saturation and the onset of condensation. For typical sterilization cycles, differences as well as identical behavior between the local sensor measurements and the global results calculated from the temperature and pressure sensors are discussed.
- Open Access
- 6 March 2013
- Published by IntechOpen
Optical Coherence Tomography – Applications in Non- Destructive Testing and Evaluation
- 6 March 2013
- Published by IntechOpen
Open AccessOptical Coherence Tomography – Applications in Non- Destructive Testing and Evaluation
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7889, 78890Z-78890Z-8
Spectral domain polarization sensitive optical coherence tomography at 1.55 μm: novel developments and applications for dynamic studies in materials science
In this paper it is demonstrated, how research in optical coherence tomography (OCT) for biomedical diagnostics successfully triggered new developments in the field of mechanical material testing. With the help of a specifically designed, compact and robust spectral domain polarization sensitive OCT (SD-PS-OCT) setup, which is operating at 1.55 μm, dynamic investigations of technical materials - like bulk polymers and composite samples - can be performed under various conditions. Already by evaluating the speckle pattern of the standard SD-OCT images with advanced image processing methods, valuable information on the deformation and flow characteristics of samples subjected to tensile tests can be obtained. By additionally taking the birefringence properties into account, complementary knowledge on the evolvement of the internal stress situation is obtained in a spatially resolved way.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7889, 78890Z-78890Z-8
Spectral domain polarization sensitive optical coherence tomography at 1.55 μm: novel developments and applications for dynamic studies in materials science
In this paper it is demonstrated, how research in optical coherence tomography (OCT) for biomedical diagnostics successfully triggered new developments in the field of mechanical material testing. With the help of a specifically designed, compact and robust spectral domain polarization sensitive OCT (SD-PS-OCT) setup, which is operating at 1.55 μm, dynamic investigations of technical materials - like bulk polymers and composite samples - can be performed under various conditions. Already by evaluating the speckle pattern of the standard SD-OCT images with advanced image processing methods, valuable information on the deformation and flow characteristics of samples subjected to tensile tests can be obtained. By additionally taking the birefringence properties into account, complementary knowledge on the evolvement of the internal stress situation is obtained in a spatially resolved way.