RSRon B. Schifman

Ron B. Schifman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ron B. Schifman has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel R. Luevano

    From the Department of Pathology & Laboratory Medicine, Southern Arizona VA Healthcare System (Dr Schifman and Mr Luevano), Tucson; and the Department of Pathology, University of Arizona, Tucson (Dr Schifman)

    2 shared publications
  • Peter J. Howanitz

    The Department of Pathology, State University of New York Downstate Medical Center, Brooklyn (Dr Howanitz)

    2 shared publications
  • Rhona J. Souers

    From the Diagnostics Department, Southern Arizona VA Healthcare System, Tuscon (Dr Schifman); the Department of Pathology, University of Arizona, Tucson (Dr Schifman); the Department of Pathology, University of Oklahoma Health Sciences Center, Oklahoma City (Dr Talbert); and the Surveys Department, College of American Pathologists, Northfield, Illinois (Ms Souers)

    2 shared publications
  • Richard J. Zarbo

    Department of Pathology, Henry Ford Hospital, Detroit, MI 48202, USA

    2 shared publications
  • Barbara J. Blond

    From Pathology and Laboratory Medicine, Southern Arizona VA Healthcare System, and the Department of Pathology, University of Arizona, Tucson (Dr Schifman); the Department of Pathology, University of West Virginia, and Clinical Laboratories, West Virginia University Hospital, Morgantown (Dr Perrotta); and Biostatistics (Ms Souers) and Surveys-Cytopathology (Ms Blond), College of American Pathologists, Northfield, Illinois

    1 shared publication
  • Bruce A. Jones

    From the Department of Anatomic Pathology, Cleveland Clinic, Cleveland, Ohio (Dr Dyhdalo); the Department of Pathology, SUNY Downstate Medical Center, Brooklyn, New York (Dr Howanitz); the Department of Pathology, Virginia Commonwealth University, Richmond (Dr Wilkinson); the Department of Biostatistics, College of American Pathologists, Northfield, Illinois (Ms Souers); and the Department of Pathology, Henry Ford West Bloomfield Hospital, Detroit, Michigan (Dr Jones)

    1 shared publication

Latest Publications

  • Open Access

    Value and Use of Urinalysis for Myoglobinuria

    by Ron B. Schifman, Daniel R. Luevano

    Context.—: Urine myoglobin testing is primarily indicated for diagnosis and risk assessment of kidney injury in patients with rhabdomyolysis. However, its utility is limited by a lack of rapid and reliable results. Myoglobin reacts positively for blood by urine dipstick, which can serve as an indicator of myoglobinuria. Objective.—: To evaluate the performance and value of blood and red cell measurements by urinalysis as a surrogate test for myoglobinuria in routine clinical practice. Design.—: This study is a retrospective observational study involving analysis of hemoglobin and red blood cell results by urinalysis in patients tested for urine myoglobin. Results.—: A total of 13 139 urine myoglobin results from 88 Veterans Affairs facilities during a 15-year period ending in October 2014 were evaluated. Among methods used by each laboratory, qualitative urine myoglobin tests declined from 25 of 53 (47.1%) in 2000 to 5 of 77 (6.4%) in 2013. Of 7311 tests (55.6%) performed by quantitative methods with concomitant urinalysis, 3915 (53.5%) showed negative to trace blood results, of which myoglobin was 1000 μg/L or greater in 17 (0.4%). Among 1875 (25.5%) with 3+ (large) blood results, urine myoglobin was ≥1000 μg/L in 273 of 1533 (17.8%) with hematuria (≥5 red blood cells per microliter) and 109 of 342 (31.9%) without hematuria. Conclusions.—: Urinalysis results reliably predicted the absence of myoglobinuria and could be used to avert overtesting for urine myoglobin while also providing useful diagnostic information when urine myoglobin test results are not immediately available.


  • A Q-Probes Study Involving Utilization of Free Prostate-Specific Antigen, Factor V Leiden, and Hepatitis A Serology Tests

    by Ron B. Schifman, Peter L. Perrotta, Rhona Souers, Barbara J. Blond

    Context.—: Managing the utilization of laboratory tests is an important quality improvement activity that adds value to health care. Objective.—: To examine utilization of 3 laboratory tests and identify factors that impact performance. Design.—: Test utilization performance was evaluated by determining the frequency with which appropriate preconditions for testing were met. This included 30 testing episodes each involving (1) free prostate-specific antigen (PSA) when total PSA was within an appropriate interpretable range, (2) total anti–hepatitis A virus antibody when previous anti–hepatitis A virus antibody results were either negative or not done, and (3) factor V Leiden mutation when a previous result was not already available. Participants also provided information regarding some of their utilization policies and procedures for these 3 tests. Results.—: The overall frequency with which testing criteria were met was 20.6% (163 of 790), 91.5% (649 of 709), and 95.2% (799 of 839) for free PSA, anti–hepatitis A virus antibody, and factor V Leiden, respectively. Utilization review was infrequent and done by 20.7% (6 of 29) of participants for factor V Leiden, 3.6% (1 of 28) for anti–hepatitis A virus antibody, and 3.6% (1 of 28) for free PSA. No practice or demographic characteristics were significantly associated with utilization performance for any test. Conclusions.—: Utilization review was infrequent for the 3 tests examined. Variable amounts of unnecessary testing were observed for all tests, most frequently for free PSA, for which reporting results carried the added risk of diagnostic error from misinterpretation of results.


  • Aluminum Toxicity: Evaluation of 16-Year Trend Among 14 919 Patients and 45 480 Results

    by Ron B. Schifman, Daniel R. Luevano

    Context.—: Annual monitoring with serum aluminum measurements is recommended for dialysis patients who are susceptible to toxic accumulation from contaminated dialysis fluid or from ingestion of aluminum-containing medications. Objective.—: To evaluate long-term trends in serum aluminum concentrations and frequency of chronic toxicity. Design.—: A retrospective observational study was conducted by analyzing serum aluminum results obtained from the Veterans Affairs corporate data warehouse. Serum aluminum concentrations of 60 μg/L or greater were considered false positives and not indicative of chronic toxicity if another specimen retested within 45 days had a concentration below 20 μg/L. Results.—: A total of 45 480 serum aluminum results involving 14 919 patients and 119 Veteran Affairs facilities during a 16-year period ending in October 2016 were evaluated. The percentage of elevated (≥20 μg/L) serum aluminum results declined from 31.5% in 2000 to 2.0% in 2015. Average testing intervals changed from every 159 days in 2000 to every 238 days in 2015. Of 529 patients with serum aluminum concentrations of 60 μg/L or greater, 216 (40.8%) were retested within 45 days (average = 21 days); of these, 83 (38.4%) had concentrations below 20 μg/L after repeated measurements. Retesting rates increased with higher initial serum aluminum concentrations. Conclusions.—: Aluminum toxicity, as assessed by serum levels, has substantially declined over time and is now rare. Many serum aluminum concentrations in the toxic range were not confirmed after retesting. Patients with toxic serum aluminum concentrations should be retested with another specimen before undergoing treatment or investigating sources of exposure to verify abnormal results.


  • Delta Check Practices and Outcomes: A Q-Probes Study Involving 49 Health Care Facilities and 6541 Delta Check Alerts

    by Ron B. Schifman, Michael Talbert, Rhona J. Souers

    Context.—: Delta checks serve as a patient-based quality control tool to detect testing problems. Objective.—: To evaluate delta check practices and outcomes. Design.—: Q-Probes participants provided information about delta check policies and procedures. Information about investigations, problems, and corrective actions was prospectively collected for up to 100 testing episodes involving delta check alerts. Results.—: Among 4505 testing episodes involving 6541 delta check alerts, the median frequencies of actions taken among 49 laboratories were clinical review, 38.0%; retest, 25.0%, or recheck, 20.2%; current specimen, nothing, 15.4%; analytical check, 5.0%; other; 2%; and retest or check previous specimen, 0%. Rates of any action taken by analyte ranged from 84 of 179 (46.9%) for glucose to 748 of 868 (86.2%) for hemoglobin and potassium. Among 4505 testing episodes, nontesting problems included physiologic causes (1472; 32.7%); treatment causes (1318; 19.2%); and transfusion causes (846; 9.9%). Testing problems included 77 interference (1.7%), 62 contamination (1.4%), 51 clotting (1.1%), 27 other (0.6%), 12 mislabeling (0.3%), and 5 analytical (0.1%). Testing problems by analyte ranged from 13 of 457 (2.8%) for blood urea nitrogen to 12 of 46 (26.1%) for mean corpuscular hemoglobin concentration. Using more delta check analytes was associated with detecting more testing problems (P = .04). More delta check alerts per testing episode resulted in more actions taken (P = .001) and more problems identified (P < .001). The most common outcome among 4500 testing episodes was reporting results without modifications or comments in 2512 (55.8%); results were not reported in 136 (3.0%). Conclusions.—: Actions taken in response to delta check alerts varied widely, and most testing problems detected were preanalytical. Using a higher number of different analytes and evaluating previous specimens may improve delta check practices.


  • Point-of-Care Glucose Critical Values: A Q-Probes Study Involving 50 Health Care Facilities and 2349 Critical Results

    by Ron B. Schifman, Peter J. Howanitz, Rhona J. Souers

    Context: Accuracy of blood glucose measurements in the critical value range is important for properly treating patients with severe hypoglycemia and hyperglycemia. Objective: To evaluate the performance and reliability of point-of-care glucose (POCG) results in the critical value range among multiple facilities. Design: Q-Probes participants retrospectively collected data from up to 50 POCG results in their critical value range including patient location, type of testing operator, repeat glucose results, and caregiver notification. A repeat measurement at 10 minutes or less that was within 15 mg/dL of initial critical low or 20% of initial critical high value was considered a confirmed result. Results: Fifty facilities submitted data. Of 2349 critical POCG measurements, 1386 (59.0%) were retested. The median institutional retest rate was 56%. The retest rate was significantly higher when initial results were in the critical low range, P < .001. Although 30 of 50 facilities (60%) had written procedures for retesting, this was not associated with higher retest rates (P = .34). Among 35 facilities that routinely retested critical POCG results, 23 (65.7%) had criteria defined for interpreting results. The median institutional confirmation rate for retested specimens was 81.7%. The median institutional rate for caregiver notification of critical POCG results was 85.7%. Five hundred eighty-six of 1488 critical POCG notifications (39.4%) were done on patients in whom specimens were not retested. Conclusions: This study shows that POCG results in the critical range may be unreliable because of testing errors that are not recognized from lack of confirmatory testing. In addition, notification of critical POCG results is not consistently performed.


  • Q-tracks: a College of American Pathologists program of continuous laboratory monitoring and longitudinal tracking.

    by Richard J Zarbo, Bruce A Jones, Richard C Friedberg, Paul N Valenstein, Stephen W Renner, Ron B Schifman, Molly K Walsh, Peter J Howanitz

    Continuous monitoring of key laboratory indicators of quality by hundreds of laboratories in a standardized measurement program affords an opportunity to document the influence of longitudinal tracking on performance improvement by participants focused on that outcome. To describe the results of the first 2 years of participation in a unique continuous performance assessment program for pathology and laboratory medicine. Participants in any of 6 modules in the 1999 and 2000 College of American Pathologists (CAP) Q-Tracks program collected data according to defined methods and sampling intervals on standardized input forms. Data were submitted quarterly to CAP for statistical analysis. Interinstitutional comparison reports returned in 6 weeks provided each laboratory with its performance profile of key indicators and its percentile ranking compared with all participants in that quarter. This also included longitudinal comparisons of performance during previous cumulative quarters. Control charts graphically displayed data with flags identifying performance points that were out of statistical control. Hospital-based laboratories in the United States (98%), Canada, and Australia. Voluntary subscriber laboratories in the CAP Q-Tracks performance measurement program: roughly 70% from hospitals of 300 occupied beds or fewer, 65% from private, nonprofit institutions, slightly more than half located in cities, one third from teaching hospitals, and 20% with pathology residency training programs. Each module measured several major and additional minor quality indicators and unbenchmarked individualized data for internal use. Participants in 4 of 6 Q-Tracks continuous monitors demonstrated statistically significant performance improvement trends in 1999 and 2000, which were most marked for laboratories that continued participation throughout both years. These monitors were wristband patient identification, laboratory specimen acceptability, blood product wastage, and intraoperative frozen section consultation. Key continuous indicators chosen on the basis of a decade's experience in the CAP Q-Probes quality improvement program are useful measurement and benchmarking tools for laboratories to improve performance. In general, measures in which there is a broad range of demonstrable performance initially are most optimal for subsequent improvement using continuous monitoring. These studies have shown that quality is not static, but rather is a moving benchmark of performance as seen in the redefinition of benchmarks over time by participants in the first 2 years of the CAP Q-Tracks program.


  • A NATIONWIDE QUALITY ASSURANCE PROGRAM CAN DESCRIBE STANDARDS FOR TITLE PRACTICE OF PATHOLOGY AND LABORATORY MEDICINE

    by Peter J. Howanitz, Gerald G. Hoffman, Ron B. Schifman, Richard J. Zarbo, Steven J. Steindel, Keith Walker

    An important component of quality assessment is the analysis of peer group comparisons, although little data are available for evaluation. We developed and tested six interlastirutional quality indicators related to Pathology and Laboratory Medicine among 36 institutions. Results showed that the mean frequency of intraoperative frozen section consultations (6.0%), sensitivity of fine needle aspiration cytology diagnosis (87%), nosocomial infections (5.0%) and average cross-match to trans fusion ratio (2.1%) was comparable with previous studies, but the range of values was large. The median stat laboratory turnaround time of approximately 1 hr for CSF cell count, glucose, protein and gram smear was considerably longer than expected from previous investigations, and was longer for larger institutions. Analysis of serious laboratory reporting errors showed the lowest number detected by individuals working in transfusion medicine, and highest numbers among hematology workers. We conclude that interinstitulional comparison of data from quality assurance programs can be used to describe performance standards related to the quality and effectiveness of care.