Ryan B. Berke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ryan B. Berke has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
Brandon A. Furman
Mechanical and Aerospace Engineering Utah State University Logan Utah USA
5 shared publications- Prasenjit Dewanjee
Mechanical and Aerospace Engineering Utah State University Logan Utah USA
4 shared publications - Renee Vickerman Galliher
Utah State University
4 shared publications - Robert Scott Hansen
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
4 shared publications - Harley Cragun3 shared publications
- Joshua G. Parmenter
School of Counseling and Counseling Psychology, Arizona State University
3 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Elsevier in SSRN Electronic Journal
A Surrogate Window to Benchmark Camera-based Strain Measurements at INL’s Hot Fuels Examination Facility
Post-Irradiation Examination (PIE) is a critical step towards qualifying nuclear structural materials for safe use in a nuclear reactor. Hot cell facilities such as INL's Hot Fuels Examination Facility (HFEF) enable PIE by protecting scientists from radiation and contamination environments. As an alternative to sending contact-based measurements inside the hot cell, where they quickly degrade and become rad-contaminated; camera-based methods such as Digital Image Correlation (DIC) become preferable. However, although DIC has been widely demonstrated in literature through viewing windows on the order of 1 cm thick, the windows at HFEF are on the order of 4-feet thick, making DIC measurements through them much more susceptible to thick-glass distortions. This paper presents the design and construction of a low-cost, surrogate window which mimics the expected thick-glass distortions at HFEF. Benchmark DIC experiments are then performed through the window to quantify the experimental uncertainty of measurements to be performed at HFEF. Additional insights from troubleshooting the DIC measurements are also presented to help in designing future experiments at HFEF.
- 6 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Surrogate Window to Benchmark Camera-based Strain Measurements at INL’s Hot Fuels Examination Facility
Post-Irradiation Examination (PIE) is a critical step towards qualifying nuclear structural materials for safe use in a nuclear reactor. Hot cell facilities such as INL's Hot Fuels Examination Facility (HFEF) enable PIE by protecting scientists from radiation and contamination environments. As an alternative to sending contact-based measurements inside the hot cell, where they quickly degrade and become rad-contaminated; camera-based methods such as Digital Image Correlation (DIC) become preferable. However, although DIC has been widely demonstrated in literature through viewing windows on the order of 1 cm thick, the windows at HFEF are on the order of 4-feet thick, making DIC measurements through them much more susceptible to thick-glass distortions. This paper presents the design and construction of a low-cost, surrogate window which mimics the expected thick-glass distortions at HFEF. Benchmark DIC experiments are then performed through the window to quantify the experimental uncertainty of measurements to be performed at HFEF. Additional insights from troubleshooting the DIC measurements are also presented to help in designing future experiments at HFEF.
- Open Access
- 3 September 2026
- Published by Springer Nature in Experimental Mechanics
- p. 1-18
Full-Field Measurement Uncertainty Quantification for Luminescence Phosphor Thermography on Surfaces in 3D Space
Background: The luminescent intensity ratio (LIR) method of measuring temperature with thermographic phosphors has long been reported to exhibit sensitivities to experimental geometry as a test article moves in 3D space. Objective: This work aims to evaluate the sensitivity of combined thermographic phosphor digital image correlation (TP+DIC) to experimental geometry and test article motion. In doing so, two novel geometry compensated formulations of LIR are derived that ensure consistent phosphor emission volume is measured in both cameras and compared against the traditional LIR methods. Methods: Full-field uncertainty quantification techniques were applied to compare traditional LIR methods to the novel LIR methods as the phosphor moved throughout a measurement volume representative of a thermomechanical experiment. Three experiments were performed: (Experiment A) systematic rotation at room temperature to evaluate the angular emission profile of the phosphor coating, (Experiment B) systematic translation where temperature calibrations were taken at each fixed location in space, and (Experiment C) compound translation/rotation at two steady-state temperatures. Results: Experiment A showed that the phosphor coating was non-Lambertian, and compensation was achieved using the viewing angle measured from DIC. Experiment B showed that while mean filtered traditional LIR measurements may yield accurate temperature measurements at a single position in space, they often suffer from significant bias during material motion that can be reduced by 3x by moving to geometry compensated LIR techniques. Finally, Experiment C confirmed that applying mean filters to traditional LIR methods causes significant over-confidence in the measurement and showed that the temperature calibration of the non-Lambertian geometry compensated LIR method remained reliable at all positions within the working volume. Conclusion: Through all three experiments, it is shown that the geometry compensated, non-Lambertian (GCNL) method remains consistently aligned with the temperature calibration. Therefore, the new GCNL LIR method presented herein can be applied to complex thermomechanical experiments while using the prediction interval from the temperature calibration as a reasonable full-field uncertainty estimate throughout deformation.
- 3 September 2026
- Published by Springer Nature in Experimental Mechanics
- p. 1-18
Open AccessFull-Field Measurement Uncertainty Quantification for Luminescence Phosphor Thermography on Surfaces in 3D Space
Background: The luminescent intensity ratio (LIR) method of measuring temperature with thermographic phosphors has long been reported to exhibit sensitivities to experimental geometry as a test article moves in 3D space. Objective: This work aims to evaluate the sensitivity of combined thermographic phosphor digital image correlation (TP+DIC) to experimental geometry and test article motion. In doing so, two novel geometry compensated formulations of LIR are derived that ensure consistent phosphor emission volume is measured in both cameras and compared against the traditional LIR methods. Methods: Full-field uncertainty quantification techniques were applied to compare traditional LIR methods to the novel LIR methods as the phosphor moved throughout a measurement volume representative of a thermomechanical experiment. Three experiments were performed: (Experiment A) systematic rotation at room temperature to evaluate the angular emission profile of the phosphor coating, (Experiment B) systematic translation where temperature calibrations were taken at each fixed location in space, and (Experiment C) compound translation/rotation at two steady-state temperatures. Results: Experiment A showed that the phosphor coating was non-Lambertian, and compensation was achieved using the viewing angle measured from DIC. Experiment B showed that while mean filtered traditional LIR measurements may yield accurate temperature measurements at a single position in space, they often suffer from significant bias during material motion that can be reduced by 3x by moving to geometry compensated LIR techniques. Finally, Experiment C confirmed that applying mean filters to traditional LIR methods causes significant over-confidence in the measurement and showed that the temperature calibration of the non-Lambertian geometry compensated LIR method remained reliable at all positions within the working volume. Conclusion: Through all three experiments, it is shown that the geometry compensated, non-Lambertian (GCNL) method remains consistently aligned with the temperature calibration. Therefore, the new GCNL LIR method presented herein can be applied to complex thermomechanical experiments while using the prediction interval from the temperature calibration as a reasonable full-field uncertainty estimate throughout deformation.
- 24 August 2026
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 49 (11) , 4999-5016
A High‐Throughput Approach for Load‐Controlled Tension–Tension Fatigue Testing
Fatigue characterization, particularly for conditions associated with relatively short fatigue lives, remains time‐consuming and resource intensive. This study presents a uniaxial, load‐controlled tension–tension fatigue methodology employing a multi‐specimen, serially linked assembly to enhance experimental throughput while maintaining adherence to established testing standards. Specimens were designed with incremental cross‐sectional variations such that a single applied force produces multiple stress levels within one experiment. Four experimental configurations were investigated: individual specimen testing; serial testing with sequential removal of failed specimens; serial testing with specimen replacement until each type failed once; and serial testing with stress‐targeted replacement specimens. A total of 57 small‐scale 316 stainless steel flat coupons were tested at R ≈ 0 and maximum stresses between 510 and 590 MPa. Digital image correlation (DIC) was used to quantify strain and local damage evolution. The high‐throughput configurations yielded fatigue lives within ±2.12% of conventional single‐specimen tests while reducing overall testing time by up to a factor of 3.6.
- 24 August 2026
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 49 (11) , 4999-5016
A High‐Throughput Approach for Load‐Controlled Tension–Tension Fatigue Testing
Fatigue characterization, particularly for conditions associated with relatively short fatigue lives, remains time‐consuming and resource intensive. This study presents a uniaxial, load‐controlled tension–tension fatigue methodology employing a multi‐specimen, serially linked assembly to enhance experimental throughput while maintaining adherence to established testing standards. Specimens were designed with incremental cross‐sectional variations such that a single applied force produces multiple stress levels within one experiment. Four experimental configurations were investigated: individual specimen testing; serial testing with sequential removal of failed specimens; serial testing with specimen replacement until each type failed once; and serial testing with stress‐targeted replacement specimens. A total of 57 small‐scale 316 stainless steel flat coupons were tested at R ≈ 0 and maximum stresses between 510 and 590 MPa. Digital image correlation (DIC) was used to quantify strain and local damage evolution. The high‐throughput configurations yielded fatigue lives within ±2.12% of conventional single‐specimen tests while reducing overall testing time by up to a factor of 3.6.
- 10 August 2026
- Published by Taylor & Francis in Psychology & Sexuality
- p. 1-19
Vocational identity development of LGBTQ+ engineering college students: testing the minority stress model
Minority stress theory (MST) is a comprehensive framework originally proposed to understand how social and cultural factors affect the well-being of lesbian women (Brooks, 1981). This theory has su...
- 10 August 2026
- Published by Taylor & Francis in Psychology & Sexuality
- p. 1-19
Vocational identity development of LGBTQ+ engineering college students: testing the minority stress model
Minority stress theory (MST) is a comprehensive framework originally proposed to understand how social and cultural factors affect the well-being of lesbian women (Brooks, 1981). This theory has su...
- Open Access
- 8 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (27) , 275407
Digital image correlation at high magnification: the effect of shorter wavelength on diffraction limit of light
Digital image correlation (DIC) is an optical technique that uses image registration methods to analyze images to track the motion of an applied random speckle pattern for full-field measurements. Due to its optical nature, DIC becomes very advantageous to be used in scenarios with long working distances and high magnification applications. However, in such applications, DIC faces challenges due to the diffraction of light. According to Rayleigh’s criterion, this can be improved by either: (a) shortening the working distance, (b) using a lens with a wider aperture, and/or (c) using a shorter wavelength of light. However, longer working distances may be required in extreme environments, and a smaller aperture is often desirable in DIC for a better depth of field. In such cases, the use of a shorter wavelength becomes preferable as it can help improve diffraction-induced degradations. This work demonstrates the benefits of using a shorter wavelength of light in a long working distance and high magnification environment for providing more precise DIC measurements. In this study, four different wavelengths of light, including UV-A (365 nm), blue (470 nm), red (630 nm), and green (525 nm), were used in a three-point bending test. The results showed that shorter wavelengths produced smaller calculated Airy disk sizes and improved practical DIC performance. The Airy disk size increased from 0.027 mm (25 pixels) for UV-A to 0.046 mm (43 pixels) for red, while the root mean square (RMS) residual increased from 0.20 to 0.52 pixels, and the dropped subset percentage increased from 2.78% to 21.22%. Shorter wavelengths also enabled smaller usable subset sizes and reduced measurement scatter. Overall, the results indicate a clear wavelength dependence in DIC performance for the present high-magnification, long-working-distance optical system. While UV-A provided the best performance overall, blue illumination still offered a practical intermediate improvement, with lower RMS residuals and dropped subset percentages than the green and red wavelengths tested.
- 8 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (27) , 275407
Open AccessDigital image correlation at high magnification: the effect of shorter wavelength on diffraction limit of light
Digital image correlation (DIC) is an optical technique that uses image registration methods to analyze images to track the motion of an applied random speckle pattern for full-field measurements. Due to its optical nature, DIC becomes very advantageous to be used in scenarios with long working distances and high magnification applications. However, in such applications, DIC faces challenges due to the diffraction of light. According to Rayleigh’s criterion, this can be improved by either: (a) shortening the working distance, (b) using a lens with a wider aperture, and/or (c) using a shorter wavelength of light. However, longer working distances may be required in extreme environments, and a smaller aperture is often desirable in DIC for a better depth of field. In such cases, the use of a shorter wavelength becomes preferable as it can help improve diffraction-induced degradations. This work demonstrates the benefits of using a shorter wavelength of light in a long working distance and high magnification environment for providing more precise DIC measurements. In this study, four different wavelengths of light, including UV-A (365 nm), blue (470 nm), red (630 nm), and green (525 nm), were used in a three-point bending test. The results showed that shorter wavelengths produced smaller calculated Airy disk sizes and improved practical DIC performance. The Airy disk size increased from 0.027 mm (25 pixels) for UV-A to 0.046 mm (43 pixels) for red, while the root mean square (RMS) residual increased from 0.20 to 0.52 pixels, and the dropped subset percentage increased from 2.78% to 21.22%. Shorter wavelengths also enabled smaller usable subset sizes and reduced measurement scatter. Overall, the results indicate a clear wavelength dependence in DIC performance for the present high-magnification, long-working-distance optical system. While UV-A provided the best performance overall, blue illumination still offered a practical intermediate improvement, with lower RMS residuals and dropped subset percentages than the green and red wavelengths tested.
- Open Access
- 17 June 2026
- Published by Springer Nature in Experimental Techniques
A Novel High-Throughput Method for Performing Multiple Creep Tests Simultaneously
Creep is a phenomenon occurring in materials subjected to constant stress or load for a prolonged period of time on the scale of weeks, months, or years. In this work, we introduce a novel high-throughput technique to perform multiple creep tests simultaneously. The method works by coupling four specimens in series and loading them simultaneously. Although all specimens experience the same force, each has a different cross-sectional area, and thereby experiences a different stress. The resulting strains are then monitored using Digital Image Correlation, which facilitates the independent assessment of creep deformation in each specimen. To validate the technique, we use commercial 316 L stainless steel machined to 1/5 scale ASTM-E8 pin-loaded specimens. Two different sets of experiments are conducted at 650 °C and 325 MPa, 300 MPa, 275 MPa, and 250 MPa: (i) single-specimen tests to provide a benchmark measurement; and (ii) four specimens connected in series, to demonstrate the high-throughput technique. Successful validation showed that the high-throughput technique is capable of conducting up to four times as many creep tests within the same timeframe, thus significantly expediting the characterization of new alloys for creep resistance.
- 17 June 2026
- Published by Springer Nature in Experimental Techniques
Open AccessA Novel High-Throughput Method for Performing Multiple Creep Tests Simultaneously
Creep is a phenomenon occurring in materials subjected to constant stress or load for a prolonged period of time on the scale of weeks, months, or years. In this work, we introduce a novel high-throughput technique to perform multiple creep tests simultaneously. The method works by coupling four specimens in series and loading them simultaneously. Although all specimens experience the same force, each has a different cross-sectional area, and thereby experiences a different stress. The resulting strains are then monitored using Digital Image Correlation, which facilitates the independent assessment of creep deformation in each specimen. To validate the technique, we use commercial 316 L stainless steel machined to 1/5 scale ASTM-E8 pin-loaded specimens. Two different sets of experiments are conducted at 650 °C and 325 MPa, 300 MPa, 275 MPa, and 250 MPa: (i) single-specimen tests to provide a benchmark measurement; and (ii) four specimens connected in series, to demonstrate the high-throughput technique. Successful validation showed that the high-throughput technique is capable of conducting up to four times as many creep tests within the same timeframe, thus significantly expediting the characterization of new alloys for creep resistance.
- Open Access
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
A Multi-scale DIC Technique for Simultaneous Measurement using a Multi-color Speckle Pattern
Digital image correlation (DIC) is a commonly used optical technique for full-field deformation measurement in experimental mechanics. However, many problems involve deformation features across multiple length scales. This makes interpretation challenging when measurements are limited to a single field of view or spatial resolution. This work presents a test-ready simultaneous multiscale DIC method that allows both global and local measurements to be taken at the same time on the same specimen surface. Two different speckle patterns are applied to a single surface: a coarse red pattern for low magnification and a fine blue pattern for high magnification. Each pattern is viewed separately by applying a compatible optical band pass filter to a monochrome camera. The method is demonstrated through ring compression testing, where global bending and localization in the contact region develop together. The low-magnification fields provide global context, while the high-magnification fields clarify contact-adjacent localization at a smaller effective DIC length scale. The robustness of this method is checked using a swapped-channel contrast control, where the magnification and texture pairing is intentionally reversed. This produces predictably reduced localization contrast and blurred gradients. Measured strain fields are further evaluated through rigid-body translation checks and comparison with finite-element predictions, supporting the proposed method as a practical route to synchronized global-local interpretation in conventional mechanical testing.
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Multi-scale DIC Technique for Simultaneous Measurement using a Multi-color Speckle Pattern
Digital image correlation (DIC) is a commonly used optical technique for full-field deformation measurement in experimental mechanics. However, many problems involve deformation features across multiple length scales. This makes interpretation challenging when measurements are limited to a single field of view or spatial resolution. This work presents a test-ready simultaneous multiscale DIC method that allows both global and local measurements to be taken at the same time on the same specimen surface. Two different speckle patterns are applied to a single surface: a coarse red pattern for low magnification and a fine blue pattern for high magnification. Each pattern is viewed separately by applying a compatible optical band pass filter to a monochrome camera. The method is demonstrated through ring compression testing, where global bending and localization in the contact region develop together. The low-magnification fields provide global context, while the high-magnification fields clarify contact-adjacent localization at a smaller effective DIC length scale. The robustness of this method is checked using a swapped-channel contrast control, where the magnification and texture pairing is intentionally reversed. This produces predictably reduced localization contrast and blurred gradients. Measured strain fields are further evaluated through rigid-body translation checks and comparison with finite-element predictions, supporting the proposed method as a practical route to synchronized global-local interpretation in conventional mechanical testing.
Tradeoffs in Lighting When Applying Digital Image Correlation to Vibration‐Based Fatigue Testing
Digital Image Correlation (DIC) is a popular camera‐based, non‐contacting method to obtain full‐field displacement and strain measurements. In a vibration‐based fatigue test, DIC is desirable because DIC can continue to monitor strain after a strain gage would have failed. When applied to vibration‐based testing, one of the major challenges of DIC is maintaining sufficient lighting. Large out‐of‐plane displacements necessitate small apertures for improved depth of field while high frequency oscillation requires short exposure times to reduce motion blur. In this work, the tradeoffs in aperture, exposure time, gain, and external lighting are examined. First, a Design of Experiment (DOE) response surface test matrix is generated for each light source and aperture size. Second, strains are estimated using a laser vibrometer for which there is a pre‐determined relationship between its measured displacement and the strains measured by a strain gauge at lower amplitudes. Third, strains are additionally measured by fitting an analytical solution to full‐field deformation obtained using DIC. Further, a Monte Carlo Method uncertainty propagation was performed to determine the uncertainty between the two strain measurements. The strobe lights provided the most accurate and stable strain measurements while the ring lights provided the smallest tolerance range. In most cases, the use of Gain was found to be relatively harmless, which runs counter to the common wisdom that it should be generally avoided in DIC. In some extreme cases, Gain even produced less error than leaving the Gain as zero, but there are also counter‐examples for which increased Gain produced worse outcomes. Thus, although in some situations Gain may be the least‐worst option based on the needs of the experiment, DIC users should be cautioned not to over‐rely on Gain without careful consideration of other lighting methods.
Tradeoffs in Lighting When Applying Digital Image Correlation to Vibration‐Based Fatigue Testing
Digital Image Correlation (DIC) is a popular camera‐based, non‐contacting method to obtain full‐field displacement and strain measurements. In a vibration‐based fatigue test, DIC is desirable because DIC can continue to monitor strain after a strain gage would have failed. When applied to vibration‐based testing, one of the major challenges of DIC is maintaining sufficient lighting. Large out‐of‐plane displacements necessitate small apertures for improved depth of field while high frequency oscillation requires short exposure times to reduce motion blur. In this work, the tradeoffs in aperture, exposure time, gain, and external lighting are examined. First, a Design of Experiment (DOE) response surface test matrix is generated for each light source and aperture size. Second, strains are estimated using a laser vibrometer for which there is a pre‐determined relationship between its measured displacement and the strains measured by a strain gauge at lower amplitudes. Third, strains are additionally measured by fitting an analytical solution to full‐field deformation obtained using DIC. Further, a Monte Carlo Method uncertainty propagation was performed to determine the uncertainty between the two strain measurements. The strobe lights provided the most accurate and stable strain measurements while the ring lights provided the smallest tolerance range. In most cases, the use of Gain was found to be relatively harmless, which runs counter to the common wisdom that it should be generally avoided in DIC. In some extreme cases, Gain even produced less error than leaving the Gain as zero, but there are also counter‐examples for which increased Gain produced worse outcomes. Thus, although in some situations Gain may be the least‐worst option based on the needs of the experiment, DIC users should be cautioned not to over‐rely on Gain without careful consideration of other lighting methods.
- Open Access
- 19 September 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (1)
Additive Manufacturing of Negative Thermal Expansion Metamaterials Using Steels
Negative thermal expansion (NTE) materials are critical for applications sensitive to thermal expansion, such as precision instrumentation and aerospace systems, but their use is often limited by reliance on rare or expensive materials. Architected NTE metamaterials fabricated from ubiquitous structural alloys like steel present a transformative and scalable alternative. This study focuses on fabricating such metamaterials using laser powder bed fusion (LPBF) of AISI 304L stainless steel and SAE grade 300 maraging steel in bi‐material configurations. Initial efforts optimize LPBF parameters to optimize interfacial strength through detailed process‐structure‐property investigations. Mechanical properties across the interface are characterized using uniaxial tensile testing, nanoindentation, and scratch resistance measurements, while scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), and electron backscatter diffraction (EBSD) are utilized to analyze interfacial microstructure and bonding. Multiple support‐free, thermally responsive bi‐material lattice topologies are computationally designed to ensure manufacturability using LPBF, with their selection informed by finite element simulations. Subsequently, lattices are fabricated using optimized LPBF parameters and experimentally evaluated for their thermal expansion performance using digital image correlation (DIC). All lattice variants demonstrate NTE behaviour, with octagonal and dodecagonal bipyramid configurations achieving the highest magnitudes of negative thermal expansion coefficient.
- 19 September 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (1)
Open AccessAdditive Manufacturing of Negative Thermal Expansion Metamaterials Using Steels
Negative thermal expansion (NTE) materials are critical for applications sensitive to thermal expansion, such as precision instrumentation and aerospace systems, but their use is often limited by reliance on rare or expensive materials. Architected NTE metamaterials fabricated from ubiquitous structural alloys like steel present a transformative and scalable alternative. This study focuses on fabricating such metamaterials using laser powder bed fusion (LPBF) of AISI 304L stainless steel and SAE grade 300 maraging steel in bi‐material configurations. Initial efforts optimize LPBF parameters to optimize interfacial strength through detailed process‐structure‐property investigations. Mechanical properties across the interface are characterized using uniaxial tensile testing, nanoindentation, and scratch resistance measurements, while scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), and electron backscatter diffraction (EBSD) are utilized to analyze interfacial microstructure and bonding. Multiple support‐free, thermally responsive bi‐material lattice topologies are computationally designed to ensure manufacturability using LPBF, with their selection informed by finite element simulations. Subsequently, lattices are fabricated using optimized LPBF parameters and experimentally evaluated for their thermal expansion performance using digital image correlation (DIC). All lattice variants demonstrate NTE behaviour, with octagonal and dodecagonal bipyramid configurations achieving the highest magnitudes of negative thermal expansion coefficient.