Robert W. Besant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert W. Besant has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carey James Simonson
Department of Mechanical Engineering, University of Saskatchewan
5 shared publications - Richard W. Evitts
Department of Chemical and Biological Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
3 shared publications Meng Li
Colt Engineering Corp. , Edmonton, Canada
2 shared publicationsWei Shang
Department of Petroleum Engineering , University of Tulsa , Tulsa, OK
2 shared publications- Farhad Fathieh
Mem. ASME Department of Mechanical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
1 shared publication - Gazi I. Mahmood
Louisiana State University, Baton Rouge, LA
1 shared publication
Latest Publications
- 5 April 2016
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 8 (3) , 031003
Effects of Heat Loss/Gain on the Transient Testing of Heat Wheels
Heat wheels are used in ventilation systems to provide indoor thermal comfort by recovering considerable amount of sensible energy from exhaust airstream. The transient single step test is a new testing method developed to determine the sensible effectiveness of heat wheels. In practice, heat loss/gain may create large uncertainty in the sensible effectiveness obtained through the transient testing. In this study, the transient analytical model in the literature is extended to account for heat loss/gain effects in the transient testing. The results state that in particular operating conditions, the sensible effectiveness can be affected by more than 10% due to heat loss/gain. A new testing facility is developed to investigate the effects of heat loss/gain on the sensible effectiveness through transient testing of a small-scale heat exchanger. After decoupling heat loss/gain effects from transient test data, less than 2% difference was observed in the sensible effectiveness while supply and exhaust flow rate was small (Re < 209) and the temperature difference between them was ΔTst < 7.0 °C. However, the sensible effectiveness decreased more than 9% while ΔTst > 37.5 °C or Re > 600. An empirical correlation was proposed based on the transient test data that correlates the sensible effectiveness with the heat capacity rate ratio. Comparing the results of proposed correlation with literature, less than 2% difference was observed at the heat capacity rate ratio of greater than 0.5 after the heat loss/gain effects were decoupled from transient test data.
- 5 April 2016
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 8 (3) , 031003
Effects of Heat Loss/Gain on the Transient Testing of Heat Wheels
Heat wheels are used in ventilation systems to provide indoor thermal comfort by recovering considerable amount of sensible energy from exhaust airstream. The transient single step test is a new testing method developed to determine the sensible effectiveness of heat wheels. In practice, heat loss/gain may create large uncertainty in the sensible effectiveness obtained through the transient testing. In this study, the transient analytical model in the literature is extended to account for heat loss/gain effects in the transient testing. The results state that in particular operating conditions, the sensible effectiveness can be affected by more than 10% due to heat loss/gain. A new testing facility is developed to investigate the effects of heat loss/gain on the sensible effectiveness through transient testing of a small-scale heat exchanger. After decoupling heat loss/gain effects from transient test data, less than 2% difference was observed in the sensible effectiveness while supply and exhaust flow rate was small (Re < 209) and the temperature difference between them was ΔTst < 7.0 °C. However, the sensible effectiveness decreased more than 9% while ΔTst > 37.5 °C or Re > 600. An empirical correlation was proposed based on the transient test data that correlates the sensible effectiveness with the heat capacity rate ratio. Comparing the results of proposed correlation with literature, less than 2% difference was observed at the heat capacity rate ratio of greater than 0.5 after the heat loss/gain effects were decoupled from transient test data.
- 1 April 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (4) , 042601
Experimental Pressure Drop and Heat Transfer in a Rectangular Channel With a Sinusoidal Porous Screen
Experiments are conducted to investigate turbulence enhancing effects of a porous mesh-screen with a sinusoidal shape normal to the flow direction inside a rectangular cross section air channel at low Reynolds numbers (i.e., Re = 1360–3800). The baseline measurements are obtained at the same channel and Reynolds numbers without the screen present. The surface of the screen pores are oriented parallel to the mean flow. Data are presented for the total and wall-static pressure drop along the channel, Nusselt number distributions on the heated wall at several constant heat rates, and air temperature distributions at the channel exit with and without (baseline cases) the screen. The heat transfer measurements are obtained with one wall heated as well as two parallel walls heated to simulate different applications for air channels in the flat plate heat exchangers. The results indicate that the ratio of screen channel to baseline Nusselt number (Nu/Nu0) and the ratio of screen channel to baseline friction factor (f/f0) increase with the Reynolds number (Re). The fully developed Nu/Nu0 is 2.0–2.5 as the fully developed f/f0 is 4.4 at 3100 < Re ≤ 3800. However, the screen channel heat convection performance index, (Nu/Nu0)/(f/f0)1/3 is only greater than 1.0 when Re > 2500 which is the design objective of reducing the pumping power and heat transfer area in the channel. Nonetheless, the screen insert is only beneficial to augment the convective heat transfer in the channel over the range of transition Reynolds number tested. The average total pressure drop across the channel and average exit air temperature suggest that the screen insert promotes good mixing of fluid across the channel for the Reynolds numbers tested.
- 1 April 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (4) , 042601
Experimental Pressure Drop and Heat Transfer in a Rectangular Channel With a Sinusoidal Porous Screen
Experiments are conducted to investigate turbulence enhancing effects of a porous mesh-screen with a sinusoidal shape normal to the flow direction inside a rectangular cross section air channel at low Reynolds numbers (i.e., Re = 1360–3800). The baseline measurements are obtained at the same channel and Reynolds numbers without the screen present. The surface of the screen pores are oriented parallel to the mean flow. Data are presented for the total and wall-static pressure drop along the channel, Nusselt number distributions on the heated wall at several constant heat rates, and air temperature distributions at the channel exit with and without (baseline cases) the screen. The heat transfer measurements are obtained with one wall heated as well as two parallel walls heated to simulate different applications for air channels in the flat plate heat exchangers. The results indicate that the ratio of screen channel to baseline Nusselt number (Nu/Nu0) and the ratio of screen channel to baseline friction factor (f/f0) increase with the Reynolds number (Re). The fully developed Nu/Nu0 is 2.0–2.5 as the fully developed f/f0 is 4.4 at 3100 < Re ≤ 3800. However, the screen channel heat convection performance index, (Nu/Nu0)/(f/f0)1/3 is only greater than 1.0 when Re > 2500 which is the design objective of reducing the pumping power and heat transfer area in the channel. Nonetheless, the screen insert is only beneficial to augment the convective heat transfer in the channel over the range of transition Reynolds number tested. The average total pressure drop across the channel and average exit air temperature suggest that the screen insert promotes good mixing of fluid across the channel for the Reynolds numbers tested.
- 11 January 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (4) , 041601
A New Technique to Determine Convection Coefficients With Flow Through Particle Beds
A new method for determining the heat transfer coefficient for air flowing steadily through beds of particles is presented. In this technique, a step change in the inlet air temperature is applied to a small test bed and temperature distributions in the bed and at the air outlet are sampled over a short time period. The convective heat transfer coefficient is determined using data from the convective heat transfer process in the bed where the analysis includes the partial differential equation that describes the transient energy storage in the particles within the bed. The analysis is performed for a short time duration when the temperature distribution in the particle bed is almost linear along the axis of the bed. This time period permits the most accurate determination of the heat transfer coefficient using the data. Using beds of spherical particles a new correlation is developed for the Nusselt number versus the Reynolds number (5<Redh<280) and includes the uncertainty bounds. This new correlation compares well with correlations developed by some other researchers for similar spherical particle beds.
- 11 January 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (4) , 041601
A New Technique to Determine Convection Coefficients With Flow Through Particle Beds
A new method for determining the heat transfer coefficient for air flowing steadily through beds of particles is presented. In this technique, a step change in the inlet air temperature is applied to a small test bed and temperature distributions in the bed and at the air outlet are sampled over a short time period. The convective heat transfer coefficient is determined using data from the convective heat transfer process in the bed where the analysis includes the partial differential equation that describes the transient energy storage in the particles within the bed. The analysis is performed for a short time duration when the temperature distribution in the particle bed is almost linear along the axis of the bed. This time period permits the most accurate determination of the heat transfer coefficient using the data. Using beds of spherical particles a new correlation is developed for the Nusselt number versus the Reynolds number (5<Redh<280) and includes the uncertainty bounds. This new correlation compares well with correlations developed by some other researchers for similar spherical particle beds.
- 1 May 2009
- Published by Taylor & Francis in HVAC&R Research
- Vol. 15 (3) , 561-582
Run-Around Energy Recovery System for Air-to-Air Applications Using Cross-Flow Exchangers Coupled with a Porous Solid Desiccant—Part II: Results and Performance Sensitivity
The model for the run-around energy recovery system was developed and verified for sensible and latent energy transfer in Part I (Li et al. 2009). In this paper, the sensible, latent, and overall effectiveness are investigated in each exchanger as well as the run-around exchanger. The overall effectiveness of the run-around energy recovery system is dependent on the airflow rate, the solid desiccant flow rate, the desiccant properties, specific surface area, the size of each exchanger, and the inlet air operating conditions. The run-around system can achieve a high overall effectiveness when the flow rates and exchanger's properties are properly chosen. Comparisons between the solid desiccant and salt solution run-around system effectiveness (Fan et al. 2006) show they are in agreement. In a sensitivity study, the thickness of desiccant on the fiber is investigated in the solid run-around system. It was found that a good performance is obtained with very thin desiccant coatings (1 or 2 μm). During the practical use of this system, a desiccant-coated fiber could be inserted into very porous balls or cages, protecting the desiccant-coated fiber from mechanical wear. The performance sensitivity for this kind of run-around system is demonstrated.
- 1 May 2009
- Published by Taylor & Francis in HVAC&R Research
- Vol. 15 (3) , 561-582
Run-Around Energy Recovery System for Air-to-Air Applications Using Cross-Flow Exchangers Coupled with a Porous Solid Desiccant—Part II: Results and Performance Sensitivity
The model for the run-around energy recovery system was developed and verified for sensible and latent energy transfer in Part I (Li et al. 2009). In this paper, the sensible, latent, and overall effectiveness are investigated in each exchanger as well as the run-around exchanger. The overall effectiveness of the run-around energy recovery system is dependent on the airflow rate, the solid desiccant flow rate, the desiccant properties, specific surface area, the size of each exchanger, and the inlet air operating conditions. The run-around system can achieve a high overall effectiveness when the flow rates and exchanger's properties are properly chosen. Comparisons between the solid desiccant and salt solution run-around system effectiveness (Fan et al. 2006) show they are in agreement. In a sensitivity study, the thickness of desiccant on the fiber is investigated in the solid run-around system. It was found that a good performance is obtained with very thin desiccant coatings (1 or 2 μm). During the practical use of this system, a desiccant-coated fiber could be inserted into very porous balls or cages, protecting the desiccant-coated fiber from mechanical wear. The performance sensitivity for this kind of run-around system is demonstrated.
- 1 May 2009
- Published by Taylor & Francis in HVAC&R Research
- Vol. 15 (3) , 537-559
Run-Around Energy Recovery System for Air-to-Air Applications Using Cross-Flow Exchangers Coupled with a Porous Solid Desiccant—Part I: Model Development and Verification
Heat and moisture transfer between supply and exhaust air streams are investigated for a run-around system in which the coupling material is a desiccant coated solid that is transported between two exchangers. The finite volume method is used to solve the governing partial differential equations of the cross-flow heat exchangers in the supply and exhaust ducts under steady state operating conditions. The outlet air properties are calculated for several inlet air operating conditions and desiccant properties. The accuracy of the model is verified by comparing the simulations with well-known theoretical solutions for a single cross flow heat exchanger and a liquid coupled run-around system. The difference between the analytical predictions and numerical model for sensible effectiveness for each exchanger and the run-around system were found to be less than 1% over a range of operating conditions. The model is also verified by modifying the boundary conditions to represent a counter flow energy wheel and comparing the calculated sensible, latent and total effectiveness values with correlations in the literature. Part II of this paper will investigate the sensible, latent and total effectivenesses during simultaneous heat and moisture transfer.
- 1 May 2009
- Published by Taylor & Francis in HVAC&R Research
- Vol. 15 (3) , 537-559
Run-Around Energy Recovery System for Air-to-Air Applications Using Cross-Flow Exchangers Coupled with a Porous Solid Desiccant—Part I: Model Development and Verification
Heat and moisture transfer between supply and exhaust air streams are investigated for a run-around system in which the coupling material is a desiccant coated solid that is transported between two exchangers. The finite volume method is used to solve the governing partial differential equations of the cross-flow heat exchangers in the supply and exhaust ducts under steady state operating conditions. The outlet air properties are calculated for several inlet air operating conditions and desiccant properties. The accuracy of the model is verified by comparing the simulations with well-known theoretical solutions for a single cross flow heat exchanger and a liquid coupled run-around system. The difference between the analytical predictions and numerical model for sensible effectiveness for each exchanger and the run-around system were found to be less than 1% over a range of operating conditions. The model is also verified by modifying the boundary conditions to represent a counter flow energy wheel and comparing the calculated sensible, latent and total effectiveness values with correlations in the literature. Part II of this paper will investigate the sensible, latent and total effectivenesses during simultaneous heat and moisture transfer.
- 24 March 2009
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 27 (2) , 166-176
The Relationship between Cake Strength of Potash Fertilizer and Initial Moisture Content, Particle Size, and Drying Time
In this study, a new correlation for the cake strength of potash as a function of initial moisture content, particle size, and drying time is developed. The correlation is based on the experimental data collected by Wang et al. ( 2006 Wang , Y. , R. W. Besant , R. W. Evitts , & A. Dolovich . 2006 . Measurement of cake strength in potash using a centrifuge . Part. Part. Syst. Charact. 23 ( 5 ): 399 – 407 . [Google Scholar] ) and Gillies et al. ( 2006 Gillies , D. , Y. Wang , R. W. Evitts , & R. W. Besant . 2006 . The effect of particle size and magnesium content of the strength of caked potash . In Proceedings of the 5th International Conference for Conveying and Handling of Particulate Solids, Sorrento, Italy . Ch. 2, paper no. 206. (CD-ROM) . [Google Scholar] ). For initial moisture content ranging from 0.25% to 6% (w/w), particle size ranging from 0.85 to 3.35 mm, and drying time constant ranging from 7 to 1900 min, the correlation shows that strength is linearly related to the product of the initial moisture content, X i , the inverse square of mean particle diameter, d pm , and , where t c is the drying time constant.
- 24 March 2009
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 27 (2) , 166-176
The Relationship between Cake Strength of Potash Fertilizer and Initial Moisture Content, Particle Size, and Drying Time
In this study, a new correlation for the cake strength of potash as a function of initial moisture content, particle size, and drying time is developed. The correlation is based on the experimental data collected by Wang et al. ( 2006 Wang , Y. , R. W. Besant , R. W. Evitts , & A. Dolovich . 2006 . Measurement of cake strength in potash using a centrifuge . Part. Part. Syst. Charact. 23 ( 5 ): 399 – 407 . [Google Scholar] ) and Gillies et al. ( 2006 Gillies , D. , Y. Wang , R. W. Evitts , & R. W. Besant . 2006 . The effect of particle size and magnesium content of the strength of caked potash . In Proceedings of the 5th International Conference for Conveying and Handling of Particulate Solids, Sorrento, Italy . Ch. 2, paper no. 206. (CD-ROM) . [Google Scholar] ). For initial moisture content ranging from 0.25% to 6% (w/w), particle size ranging from 0.85 to 3.35 mm, and drying time constant ranging from 7 to 1900 min, the correlation shows that strength is linearly related to the product of the initial moisture content, X i , the inverse square of mean particle diameter, d pm , and , where t c is the drying time constant.
- 1 October 1997
- Published by Taylor & Francis in HVAC&R Research
- Vol. 3 (4) , 351-368
Heat and Moisture Transfer in Desiccant Coated Rotary Energy Exchangers: Part II. Validation and Sensitivity Studies
In this paper, results from the numerical model for coupled heat and moisture transfer in rotary energy exchangers, presented in Part I, are compared with experimental data. The agreement between the measured and simulated effectivenesses (sensible, latent, and total energy) is close and within the experimental uncertainty. In addition, the effects of certain assumptions were investigated for sensitivity on the predicted performance of regenerative energy exchangers The sensitivity results are calculated with a 0.9 m diameter by 0.1 m long aluminum matrix wheel that is coated with a molecular sieve desiccant (20% by mass). The desiccant has a maximum moisture capacity of 20% by mass. The porosity of the wheel is 85% and the normal rotational speed is 20 rpm. The design mass flow rate of air is 0.5 kg/s [1.6 kg/(s·m2)] giving a face velocity of 1.3 m/s. Neglecting thermal and moisture storage in the air is shown to result in errors as large as 2.4% in the predicted effectiveness of a rotary energy exchanger at typical wheel speeds. Including the heat of sorption in the model affects the predicted effectiveness only slightly (<0.5%). However, the predicted effectiveness is greatly affected (up to 48%) by whether the heat of phase change is assumed to remain in the air or in the matrix. Controlling the energy rate of the energy exchanger by controlling wheel speed may be impractical because the sensitivity of each effectiveness to wheel speed differs with each operating condition. The model is also used to show the importance of the entry length and thermal conductivity on the predicted performance of rotary energy exchangers.
- 1 October 1997
- Published by Taylor & Francis in HVAC&R Research
- Vol. 3 (4) , 351-368
Heat and Moisture Transfer in Desiccant Coated Rotary Energy Exchangers: Part II. Validation and Sensitivity Studies
In this paper, results from the numerical model for coupled heat and moisture transfer in rotary energy exchangers, presented in Part I, are compared with experimental data. The agreement between the measured and simulated effectivenesses (sensible, latent, and total energy) is close and within the experimental uncertainty. In addition, the effects of certain assumptions were investigated for sensitivity on the predicted performance of regenerative energy exchangers The sensitivity results are calculated with a 0.9 m diameter by 0.1 m long aluminum matrix wheel that is coated with a molecular sieve desiccant (20% by mass). The desiccant has a maximum moisture capacity of 20% by mass. The porosity of the wheel is 85% and the normal rotational speed is 20 rpm. The design mass flow rate of air is 0.5 kg/s [1.6 kg/(s·m2)] giving a face velocity of 1.3 m/s. Neglecting thermal and moisture storage in the air is shown to result in errors as large as 2.4% in the predicted effectiveness of a rotary energy exchanger at typical wheel speeds. Including the heat of sorption in the model affects the predicted effectiveness only slightly (<0.5%). However, the predicted effectiveness is greatly affected (up to 48%) by whether the heat of phase change is assumed to remain in the air or in the matrix. Controlling the energy rate of the energy exchanger by controlling wheel speed may be impractical because the sensitivity of each effectiveness to wheel speed differs with each operating condition. The model is also used to show the importance of the entry length and thermal conductivity on the predicted performance of rotary energy exchangers.