Andrew D. Newton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew D. Newton has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Jarrod D. Predina
Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
4 shared publicationsSunil Singhal
Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
4 shared publications- Sunil Singhal
Division of Thoracic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, PA 19104, USA
4 shared publications Christopher J. Corbett
Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
2 shared publicationsJeffrey A. Drebin
Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY
2 shared publicationsLeilei Xia
Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
2 shared publications
Latest Publications
- 1 July 2019
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 270 (1) , 12-20
Intraoperative Near-infrared Imaging Can Identify Neoplasms and Aid in Real-time Margin Assessment During Pancreatic Resection
Objective: To determine if intraoperative near-infrared (NIR) imaging carries benefit in resection of pancreatic neoplasms. Background: Resection of pancreatic malignancies is hindered by high rates of local and distant recurrence from positive margins and unrecognized metastases. Improved tumor visualization could improve outcomes. We hypothesized that intraoperative NIR imaging with a clinically approved optical contrast agent could serve as a useful adjunct in assessing margins and extent of disease during pancreatic resections. Methods: Twenty patients were enrolled in an open-label clinical trial from July 2016 to May 2018. Subjects received second window indocyanine green (ICG) (2.5–5 mg/kg) 24 hours prior to pancreatic resection. NIR imaging was performed during staging laparoscopy and after pancreas mobilization in situ and following resection ex vivo. Tumor fluorescence was quantified using tumor-to-background ratio (TBR). Fluorescence at the specimen margin was compared to pathology evaluation. Results: Procedures included 9 pancreaticoduodenectomies, 10 distal pancreatectomies, and 1 total pancreatectomy; 21 total specimens were obtained. Three out of 8 noninvasive tumors were fluorescent (mean TBR 2.59 ± 2.57). Twelve out of 13 invasive malignancies (n = 12 pancreatic adenocarcinoma, n = 1 cholangiocarcinoma) were fluorescent (mean TBR 4.42 ± 2.91). Fluorescence at the transection margin correlated with final pathologic assessment in 12 of 13 patients. Following neoadjuvant therapy, 4 of 5 tumors were fluorescent; these 4 tumors showed no treatment response on pathology assessment. One tumor had a significant treatment response and showed no fluorescence. Conclusions: Second window ICG reliably accumulates in invasive pancreatic malignancies and provides real-time feedback during pancreatectomy. NIR imaging may help to assess the response to neoadjuvant therapy.
- 1 July 2019
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 270 (1) , 12-20
Intraoperative Near-infrared Imaging Can Identify Neoplasms and Aid in Real-time Margin Assessment During Pancreatic Resection
Objective: To determine if intraoperative near-infrared (NIR) imaging carries benefit in resection of pancreatic neoplasms. Background: Resection of pancreatic malignancies is hindered by high rates of local and distant recurrence from positive margins and unrecognized metastases. Improved tumor visualization could improve outcomes. We hypothesized that intraoperative NIR imaging with a clinically approved optical contrast agent could serve as a useful adjunct in assessing margins and extent of disease during pancreatic resections. Methods: Twenty patients were enrolled in an open-label clinical trial from July 2016 to May 2018. Subjects received second window indocyanine green (ICG) (2.5–5 mg/kg) 24 hours prior to pancreatic resection. NIR imaging was performed during staging laparoscopy and after pancreas mobilization in situ and following resection ex vivo. Tumor fluorescence was quantified using tumor-to-background ratio (TBR). Fluorescence at the specimen margin was compared to pathology evaluation. Results: Procedures included 9 pancreaticoduodenectomies, 10 distal pancreatectomies, and 1 total pancreatectomy; 21 total specimens were obtained. Three out of 8 noninvasive tumors were fluorescent (mean TBR 2.59 ± 2.57). Twelve out of 13 invasive malignancies (n = 12 pancreatic adenocarcinoma, n = 1 cholangiocarcinoma) were fluorescent (mean TBR 4.42 ± 2.91). Fluorescence at the transection margin correlated with final pathologic assessment in 12 of 13 patients. Following neoadjuvant therapy, 4 of 5 tumors were fluorescent; these 4 tumors showed no treatment response on pathology assessment. One tumor had a significant treatment response and showed no fluorescence. Conclusions: Second window ICG reliably accumulates in invasive pancreatic malignancies and provides real-time feedback during pancreatectomy. NIR imaging may help to assess the response to neoadjuvant therapy.
- 1 February 2019
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 228 (2) , 188-197
Optimization of Second Window Indocyanine Green for Intraoperative Near-Infrared Imaging of Thoracic Malignancy
Near-infrared (NIR) imaging using the second time window of indocyanine green (ICG) allows localization of pulmonary, pleural, and mediastinal malignancies during surgery. Based on empirical evidence, we hypothesized that different histologic tumor types fluoresce optimally at different ICG doses. Patients with thoracic tumors biopsy-proven or suspicious for malignancy were enrolled in an NIR imaging clinical trial. Patients received a range of ICG doses 1 day before surgery: 1 mg/kg (n = 8), 2 mg/kg (n = 8), 3 mg/kg (n = 13), 4 mg/kg (n = 8), and 5 mg/kg (n = 8). Intraoperatively, NIR imaging was performed. The endpoint was to identify the highest tumor-to-background fluorescence ratio (TBR) for each tumor type at each dose. Final pathology confirmed tumor histology. Of 45 patients, 41 had malignancies (18 non-small cell lung cancers [NSCLC], 3 pulmonary neuroendocrine tumors, 13 thoracic metastases, 4 thymomas, 3 mesotheliomas). At doses of 4 to 5 mg/kg, the TBR from primary NSCLC vs other malignancies was no different (2.70 vs 3.21, p = 1.00). At doses of 1 to 3 mg/kg, the TBR was greater for the NSCLCs (3.19 vs 1.49, p = 0.0006). Background fluorescence from the heart or ribs was observed in 1 of 16 cases at 1 to 2 mg/kg, 5 of 13 cases at 3 mg/kg, and 14 of 16 cases at 4 to 5 mg/kg; this was a major determinant of dose optimization. This is the first study to demonstrate that the optimal NIR contrast agent dose varies by tumor histology. Lower dose ICG (2 to 3 mg/kg) is superior for nonprimary lung cancers, and high dose ICG (4 to 5 mg/kg) is superior for lung cancers. This will have major implications as more intraoperative imaging trials surface in other specialties, will significantly reduce costs and may facilitate wider application.
- 1 February 2019
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 228 (2) , 188-197
Optimization of Second Window Indocyanine Green for Intraoperative Near-Infrared Imaging of Thoracic Malignancy
Near-infrared (NIR) imaging using the second time window of indocyanine green (ICG) allows localization of pulmonary, pleural, and mediastinal malignancies during surgery. Based on empirical evidence, we hypothesized that different histologic tumor types fluoresce optimally at different ICG doses. Patients with thoracic tumors biopsy-proven or suspicious for malignancy were enrolled in an NIR imaging clinical trial. Patients received a range of ICG doses 1 day before surgery: 1 mg/kg (n = 8), 2 mg/kg (n = 8), 3 mg/kg (n = 13), 4 mg/kg (n = 8), and 5 mg/kg (n = 8). Intraoperatively, NIR imaging was performed. The endpoint was to identify the highest tumor-to-background fluorescence ratio (TBR) for each tumor type at each dose. Final pathology confirmed tumor histology. Of 45 patients, 41 had malignancies (18 non-small cell lung cancers [NSCLC], 3 pulmonary neuroendocrine tumors, 13 thoracic metastases, 4 thymomas, 3 mesotheliomas). At doses of 4 to 5 mg/kg, the TBR from primary NSCLC vs other malignancies was no different (2.70 vs 3.21, p = 1.00). At doses of 1 to 3 mg/kg, the TBR was greater for the NSCLCs (3.19 vs 1.49, p = 0.0006). Background fluorescence from the heart or ribs was observed in 1 of 16 cases at 1 to 2 mg/kg, 5 of 13 cases at 3 mg/kg, and 14 of 16 cases at 4 to 5 mg/kg; this was a major determinant of dose optimization. This is the first study to demonstrate that the optimal NIR contrast agent dose varies by tumor histology. Lower dose ICG (2 to 3 mg/kg) is superior for nonprimary lung cancers, and high dose ICG (4 to 5 mg/kg) is superior for lung cancers. This will have major implications as more intraoperative imaging trials surface in other specialties, will significantly reduce costs and may facilitate wider application.
- 1 July 2018
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 10 (7) , E544-E548
Intraoperative near-infrared imaging can identify sub-centimeter colorectal cancer lung metastases during pulmonary metastasectomy
Intraoperative near-infrared imaging can identify subcentimeter colorectal cancer lung metastases during pulmonary metastasectomy
- 1 July 2018
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 10 (7) , E544-E548
Intraoperative near-infrared imaging can identify sub-centimeter colorectal cancer lung metastases during pulmonary metastasectomy
Intraoperative near-infrared imaging can identify subcentimeter colorectal cancer lung metastases during pulmonary metastasectomy
- 1 May 2018
- Published by Elsevier in Gastroenterology
- Vol. 154 (6) , S-1287-1287
854 - Intraoperative Molecular Imaging with a Tumor Hypoxia Targeted Near Infrared Contrast Agent Identifies Subcentimeter Tumor Deposits in a Murine Colorectal Carcinomatosis Model
- 1 May 2018
- Published by Elsevier in Gastroenterology
- Vol. 154 (6) , S-1287-1287
854 - Intraoperative Molecular Imaging with a Tumor Hypoxia Targeted Near Infrared Contrast Agent Identifies Subcentimeter Tumor Deposits in a Murine Colorectal Carcinomatosis Model
- Open Access
- 4 December 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 110
Folate receptor-targeted molecular imaging improves identification of malignancy during pulmonary resection: a case report
During minimally invasive pulmonary resection, both limited visualization and tactile feedback can make localization of pulmonary nodules and assessment for synchronous disease challenging. Intraoperative molecular imaging is an emerging technology that can enhance a surgeon’s ability to detect cancers at the time of resection. In this report, we describe the application of a folate receptor-targeted, near infrared optical contrast agent (OTL38) for the detection of an invasive pulmonary adenocarcinoma. During molecular imaging, an otherwise undetectable synchronous nodule was also identified. This finding resulted in intraoperative upstaging and operative plan modifications. This report marks the first successful utilization of a targeted, near infrared intraoperative molecular imaging probe useful for thoracic malignancies. This rapidly evolving technology may enhance the surgeon’s ability to perform a number of oncologic procedures including tumor localization, margin assessment and intraoperative staging.
- 4 December 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 110
Open AccessFolate receptor-targeted molecular imaging improves identification of malignancy during pulmonary resection: a case report
During minimally invasive pulmonary resection, both limited visualization and tactile feedback can make localization of pulmonary nodules and assessment for synchronous disease challenging. Intraoperative molecular imaging is an emerging technology that can enhance a surgeon’s ability to detect cancers at the time of resection. In this report, we describe the application of a folate receptor-targeted, near infrared optical contrast agent (OTL38) for the detection of an invasive pulmonary adenocarcinoma. During molecular imaging, an otherwise undetectable synchronous nodule was also identified. This finding resulted in intraoperative upstaging and operative plan modifications. This report marks the first successful utilization of a targeted, near infrared intraoperative molecular imaging probe useful for thoracic malignancies. This rapidly evolving technology may enhance the surgeon’s ability to perform a number of oncologic procedures including tumor localization, margin assessment and intraoperative staging.
- 16 November 2017
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 25 (1) , 318-325
Surgical Management of Early-Stage Esophageal Adenocarcinoma Based on Lymph Node Metastasis Risk
In early-stage esophageal adenocarcinoma (EAC), esophagectomy improves staging but also increases mortality compared with endoscopic resection. Our objective was to quantify esophagectomy mortality an
- 16 November 2017
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 25 (1) , 318-325
Surgical Management of Early-Stage Esophageal Adenocarcinoma Based on Lymph Node Metastasis Risk
In early-stage esophageal adenocarcinoma (EAC), esophagectomy improves staging but also increases mortality compared with endoscopic resection. Our objective was to quantify esophagectomy mortality an
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , S193
Intraoperative Near-Infrared Imaging with Second Window Indocyanine Green for Pancreatic Adenocarcinoma
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , S193
Intraoperative Near-Infrared Imaging with Second Window Indocyanine Green for Pancreatic Adenocarcinoma
- Open Access
- 17 February 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (1) , 1-5
Near-infrared operating lamp for intraoperative molecular imaging of a mediastinal tumor
Near-Infrared (NIR) intraoperative molecular imaging is a new diagnostic modality utilized during cancer surgery for the identification of tumors, metastases and lymph nodes. Surgeons typically use headlamps during an operation to increase visible light; however, these light sources are not adapted to function simultaneously with NIR molecular imaging technology. Here, we design a NIR cancelling headlamp and utilize it during surgery to assess whether intraoperative molecular imaging of mediastinal tumors is possible. A NIR cancelling headlamp was designed and tested using NIR spectroscopy preoperatively. Next, a 46 year-old-female was referred to the thoracic surgery clinic for a 5.8 cm mediastinal mass noted on chest x-ray. Prior to surgery, she was given intravenous indocyanine green (ICG). Then, the prototype headlamp was used in conjunction with our intraoperative molecular imaging device. The tumor was imaged both in vivo and following resection prior to pathological examination. NIR spectroscopy confirmed NIR light excitation of the unfiltered headlamp and the absence of NIR emitted light after addition of the filter. Next, in vivo imaging confirmed fluorescence of the tumor, but also demonstrated a significant amount of NIR background fluorescence emanating from the unfiltered headlamp. During imaging with the filtered headlamp, we again demonstrated a markedly fluorescent tumor but with a reduced false positive NIR signal. Final pathology was well-differentiated thymoma with negative surgical margins. NIR intraoperative molecular imaging using a systemic injection of intravenous ICG was successful in localizing a thymoma. Additionally, a simple design and implementation of a NIR cancelling headlamp reduces false positive NIR fluorescence.
- 17 February 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (1) , 1-5
Open AccessNear-infrared operating lamp for intraoperative molecular imaging of a mediastinal tumor
Near-Infrared (NIR) intraoperative molecular imaging is a new diagnostic modality utilized during cancer surgery for the identification of tumors, metastases and lymph nodes. Surgeons typically use headlamps during an operation to increase visible light; however, these light sources are not adapted to function simultaneously with NIR molecular imaging technology. Here, we design a NIR cancelling headlamp and utilize it during surgery to assess whether intraoperative molecular imaging of mediastinal tumors is possible. A NIR cancelling headlamp was designed and tested using NIR spectroscopy preoperatively. Next, a 46 year-old-female was referred to the thoracic surgery clinic for a 5.8 cm mediastinal mass noted on chest x-ray. Prior to surgery, she was given intravenous indocyanine green (ICG). Then, the prototype headlamp was used in conjunction with our intraoperative molecular imaging device. The tumor was imaged both in vivo and following resection prior to pathological examination. NIR spectroscopy confirmed NIR light excitation of the unfiltered headlamp and the absence of NIR emitted light after addition of the filter. Next, in vivo imaging confirmed fluorescence of the tumor, but also demonstrated a significant amount of NIR background fluorescence emanating from the unfiltered headlamp. During imaging with the filtered headlamp, we again demonstrated a markedly fluorescent tumor but with a reduced false positive NIR signal. Final pathology was well-differentiated thymoma with negative surgical margins. NIR intraoperative molecular imaging using a systemic injection of intravenous ICG was successful in localizing a thymoma. Additionally, a simple design and implementation of a NIR cancelling headlamp reduces false positive NIR fluorescence.