Edward J. Saenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Edward J. Saenz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Alan Strahler
Department of Earth and Environment, Boston University, Boston, MA 02215, USA
2 shared publications - Crystal Barker Schaaf
School for the Environment, University of Massachusetts Boston, Boston, MA 02125, USA
2 shared publications - Ian Paynter
School for the Environment, University of Massachusetts Boston, Boston, MA 02125, USA
2 shared publications - Zhan Li
GFZ German Research Centre for Geosciences, Potsdam, Germany
2 shared publications Daniel Genest
School for the Environment, University of Massachusetts Boston, Boston, MA, USA
1 shared publication- David Laurence Barry Jupp
CSIRO Land and Water,Australia,ACT 2601
1 shared publication
Latest Publications
- Open Access
- 15 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 56 (11) , 6324-6333
Quality Assessment of Terrestrial Laser Scanner Ecosystem Observations Using Pulse Trajectories
Considering the trajectories of pulses from terrestrial laser scanners (TLS) can provide refined models of occlusion and improve the assessment of observation quality in forests and other ecosystems. By considering the space traversed by light detection and ranging (lidar) pulses, we can separate empty regions of an ecosystem sample from unobserved regions of an ecosystem sample. We apply this method of TLS observation quality assessment, and analyze Compact Biomass Lidar 2 (CBL2) TLS observations of a single tree and of a deciduous forest stand. We show the contribution of information from each TLS scan to be inconsistent and the combination of multiple scans to have diminishing returns for new information, without guaranteeing complete coverage of a sample. We quantitatively investigate the effects of imposing information quality requirements on TLS sampling, for example, requiring minimum numbers of observations in each region or requiring regions to be observed from a minimum number of independent scans. We show empirically that rigid, predefined TLS sampling schemes, even with hypothetically dense coverage, cannot guarantee successful samples in geometrically complex systems such as forests. Through these methods, we lay the groundwork for on-the-fly assessment of observation quality according to several modeling-relevant metrics which enhance TLS ecosystem assessment. We also establish the value of flexible deployment options for TLS instruments, including the ability to deploy at a variety of heights.
- 15 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 56 (11) , 6324-6333
Open AccessQuality Assessment of Terrestrial Laser Scanner Ecosystem Observations Using Pulse Trajectories
Considering the trajectories of pulses from terrestrial laser scanners (TLS) can provide refined models of occlusion and improve the assessment of observation quality in forests and other ecosystems. By considering the space traversed by light detection and ranging (lidar) pulses, we can separate empty regions of an ecosystem sample from unobserved regions of an ecosystem sample. We apply this method of TLS observation quality assessment, and analyze Compact Biomass Lidar 2 (CBL2) TLS observations of a single tree and of a deciduous forest stand. We show the contribution of information from each TLS scan to be inconsistent and the combination of multiple scans to have diminishing returns for new information, without guaranteeing complete coverage of a sample. We quantitatively investigate the effects of imposing information quality requirements on TLS sampling, for example, requiring minimum numbers of observations in each region or requiring regions to be observed from a minimum number of independent scans. We show empirically that rigid, predefined TLS sampling schemes, even with hypothetically dense coverage, cannot guarantee successful samples in geometrically complex systems such as forests. Through these methods, we lay the groundwork for on-the-fly assessment of observation quality according to several modeling-relevant metrics which enhance TLS ecosystem assessment. We also establish the value of flexible deployment options for TLS instruments, including the ability to deploy at a variety of heights.
- Open Access
Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar
Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρapp are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρapp error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρapp from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.
Open AccessRadiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar
Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρapp are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρapp error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρapp from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.