Daniel C. McGillicuddy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel C. McGillicuddy has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Leon Dahomey Sanchez
Department of Emergency Medicine, Brigham and Women’s Hospital, Boston, USA
4 shared publications - Charles Harding
Independent Statistical Analyst, Seattle, WA, USA
3 shared publications - Dmitriy Burmistrov
Independent Statistical Analyst, Massachusetts
3 shared publications - Francesco Pompei
Exergen Corporation, Watertown, Massachusetts
3 shared publications - Samantha F. Bordonaro
Gates Vascular Institute, Professional Emergency Services, Buffalo, New York
3 shared publications Gary L. Horowitz
From the Department of Emergency Medicine (LDS, DCM, KAV, NJ) and the Department of Pathology (SF, GLH), Beth Israel Deaconess Medical Center, Boston, MA
1 shared publication
Latest Publications
- Open Access
- 24 June 2020
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 21 (4) , 909-917
Fever Incidence Is Much Lower in the Morning than the Evening: Boston and US National Triage Data
Introduction: In this observational study, we evaluated time-of-day variation in the incidence of fever that is seen at triage. The observed incidence of fever could change greatly over the day because body temperatures generally rise and fall in a daily cycle, yet fever is identified using a temperature threshold that is unchanging, such as ≥38.0° Celsius (C) (≥100.4° Fahrenheit [F]).Methods: We analyzed 93,225 triage temperature measurements from a Boston emergency department (ED) (2009-2012) and 264,617 triage temperature measurements from the National Hospital Ambulatory Medical Care Survey (NHAMCS, 2002-2010), making this the largest study of body temperature since the mid-1800s. Boston data were investigated exploratorily, while NHAMCS was used to corroborate Boston findings and check whether they generalized. NHAMCS results are nationally representative of United States EDs. Analyses focused on adults.Results: In the Boston ED, the proportion of patients with triage temperatures in the fever range (≥38.0°C, ≥100.4°F) increased 2.5-fold from morning to evening (7:00-8:59 PM vs 7:00-8:59 AM: risk ratio [RR] 2.5, 95% confidence interval [CI], 2.0-3.3). Similar time-of-day changes were observed when investigating alternative definitions of fever: temperatures ≥39.0°C (≥102.2°F) and ≥40.0°C (≥104.0°F) increased 2.4- and 3.6-fold from morning to evening (7:00-8:59 PM vs 7:00-8:59 AM: RRs [95% CIs] 2.4 [1.5-4.3] and 3.6 [1.5-17.7], respectively). Analyses of adult NHAMCS patients provided confirmation, showing mostly similar increases for the same fever definitions and times of day (RRs [95% CIs] 1.8 [1.6-2.1], 1.9 [1.4-2.5], and 2.8 [0.8-9.3], respectively), including after adjusting for 12 potential confounders using multivariable regression (adjusted RRs [95% CIs] 1.8 [1.5-2.1], 1.8 [1.3-2.4], and 2.7 [0.8-9.2], respectively), in age-group analyses (18-64 vs 65+ years), and in several sensitivity analyses. The patterns observed for fever mirror the circadian rhythm of body temperature, which reaches its highest and lowest points at similar times.Conclusion: Fever incidence is lower at morning triages than at evening triages. High fevers are especially rare at morning triage and may warrant special consideration for this reason. Studies should examine whether fever-causing diseases are missed or underappreciated during mornings, especially for sepsis cases and during screenings for infectious disease outbreaks. The daily cycling of fever incidence may result from the circadian rhythm.
- 24 June 2020
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 21 (4) , 909-917
Open AccessFever Incidence Is Much Lower in the Morning than the Evening: Boston and US National Triage Data
Introduction: In this observational study, we evaluated time-of-day variation in the incidence of fever that is seen at triage. The observed incidence of fever could change greatly over the day because body temperatures generally rise and fall in a daily cycle, yet fever is identified using a temperature threshold that is unchanging, such as ≥38.0° Celsius (C) (≥100.4° Fahrenheit [F]).Methods: We analyzed 93,225 triage temperature measurements from a Boston emergency department (ED) (2009-2012) and 264,617 triage temperature measurements from the National Hospital Ambulatory Medical Care Survey (NHAMCS, 2002-2010), making this the largest study of body temperature since the mid-1800s. Boston data were investigated exploratorily, while NHAMCS was used to corroborate Boston findings and check whether they generalized. NHAMCS results are nationally representative of United States EDs. Analyses focused on adults.Results: In the Boston ED, the proportion of patients with triage temperatures in the fever range (≥38.0°C, ≥100.4°F) increased 2.5-fold from morning to evening (7:00-8:59 PM vs 7:00-8:59 AM: risk ratio [RR] 2.5, 95% confidence interval [CI], 2.0-3.3). Similar time-of-day changes were observed when investigating alternative definitions of fever: temperatures ≥39.0°C (≥102.2°F) and ≥40.0°C (≥104.0°F) increased 2.4- and 3.6-fold from morning to evening (7:00-8:59 PM vs 7:00-8:59 AM: RRs [95% CIs] 2.4 [1.5-4.3] and 3.6 [1.5-17.7], respectively). Analyses of adult NHAMCS patients provided confirmation, showing mostly similar increases for the same fever definitions and times of day (RRs [95% CIs] 1.8 [1.6-2.1], 1.9 [1.4-2.5], and 2.8 [0.8-9.3], respectively), including after adjusting for 12 potential confounders using multivariable regression (adjusted RRs [95% CIs] 1.8 [1.5-2.1], 1.8 [1.3-2.4], and 2.7 [0.8-9.2], respectively), in age-group analyses (18-64 vs 65+ years), and in several sensitivity analyses. The patterns observed for fever mirror the circadian rhythm of body temperature, which reaches its highest and lowest points at similar times.Conclusion: Fever incidence is lower at morning triages than at evening triages. High fevers are especially rare at morning triage and may warrant special consideration for this reason. Studies should examine whether fever-causing diseases are missed or underappreciated during mornings, especially for sepsis cases and during screenings for infectious disease outbreaks. The daily cycling of fever incidence may result from the circadian rhythm.
- Open Access
Fevers Are Rarer in the Morning—Could We Be Missing Infectious Disease Cases by Screening for Fever Then?
We retrospectively studied US emergency department visits ( n =295,406), including nationally representative results. Patients were less likely to have detectable fevers during mornings, with especially large morning-evening differences during influenza outbreaks (national RR=0.56, 95%CI=0.47-0.66). This suggests morning screenings could miss otherwise-detectable cases. Twice-daily screenings could be a simple solution. However, similar COVID-19 research is needed. Article Summary Line: Fevers were about half as common in the morning as in the evening during influenza outbreaks, suggesting that mornings may be a bad time to perform once-daily fever screenings for infectious diseases, and that twice-daily screenings could be preferable.
Open AccessFevers Are Rarer in the Morning—Could We Be Missing Infectious Disease Cases by Screening for Fever Then?
We retrospectively studied US emergency department visits ( n =295,406), including nationally representative results. Patients were less likely to have detectable fevers during mornings, with especially large morning-evening differences during influenza outbreaks (national RR=0.56, 95%CI=0.47-0.66). This suggests morning screenings could miss otherwise-detectable cases. Twice-daily screenings could be a simple solution. However, similar COVID-19 research is needed. Article Summary Line: Fevers were about half as common in the morning as in the evening during influenza outbreaks, suggesting that mornings may be a bad time to perform once-daily fever screenings for infectious diseases, and that twice-daily screenings could be preferable.
- Open Access
- 9 March 2016
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 16 (1) , 1-8
Human temperatures for syndromic surveillance in the emergency department: data from the autumn wave of the 2009 swine flu (H1N1) pandemic and a seasonal influenza outbreak
The emergency department (ED) increasingly acts as a gateway to the evaluation and treatment of acute illnesses. Consequently, it has also become a key testing ground for systems that monitor and identify outbreaks of disease. Here, we describe a new technology that automatically collects body temperatures during triage. The technology was tested in an ED as an approach to monitoring diseases that cause fever, such as seasonal flu and some pandemics. Temporal artery thermometers that log temperature measurements were placed in a Boston ED and used for initial triage vital signs. Time-stamped measurements were collected from the thermometers to investigate the performance a real-time system would offer. The data were summarized in terms of rates of fever (temperatures ≥100.4 °F [≥38.0 °C]) and were qualitatively compared with regional disease surveillance programs in Massachusetts. From September 2009 through August 2011, 71,865 body temperatures were collected and included in our analysis, 2073 (2.6 %) of which were fevers. The period of study included the autumn–winter wave of the 2009–2010 H1N1 (swine flu) pandemic, during which the weekly incidence of fever reached a maximum of 5.6 %, as well as the 2010–2011 seasonal flu outbreak, during which the maximum weekly incidence of fever was 6.6 %. The periods of peak fever rates corresponded with the periods of regionally elevated flu activity. Temperature measurements were monitored at triage in the ED over a period of 2 years. The resulting data showed promise as a potential surveillance tool for febrile disease that could complement current disease surveillance systems. Because temperature can easily be measured by non-experts, it might also be suitable for monitoring febrile disease activity in schools, workplaces, and transportation hubs, where many traditional syndromic indicators are impractical. However, the system’s validity and generalizability should be evaluated in additional years and settings.
- 9 March 2016
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 16 (1) , 1-8
Open AccessHuman temperatures for syndromic surveillance in the emergency department: data from the autumn wave of the 2009 swine flu (H1N1) pandemic and a seasonal influenza outbreak
The emergency department (ED) increasingly acts as a gateway to the evaluation and treatment of acute illnesses. Consequently, it has also become a key testing ground for systems that monitor and identify outbreaks of disease. Here, we describe a new technology that automatically collects body temperatures during triage. The technology was tested in an ED as an approach to monitoring diseases that cause fever, such as seasonal flu and some pandemics. Temporal artery thermometers that log temperature measurements were placed in a Boston ED and used for initial triage vital signs. Time-stamped measurements were collected from the thermometers to investigate the performance a real-time system would offer. The data were summarized in terms of rates of fever (temperatures ≥100.4 °F [≥38.0 °C]) and were qualitatively compared with regional disease surveillance programs in Massachusetts. From September 2009 through August 2011, 71,865 body temperatures were collected and included in our analysis, 2073 (2.6 %) of which were fevers. The period of study included the autumn–winter wave of the 2009–2010 H1N1 (swine flu) pandemic, during which the weekly incidence of fever reached a maximum of 5.6 %, as well as the 2010–2011 seasonal flu outbreak, during which the maximum weekly incidence of fever was 6.6 %. The periods of peak fever rates corresponded with the periods of regionally elevated flu activity. Temperature measurements were monitored at triage in the ED over a period of 2 years. The resulting data showed promise as a potential surveillance tool for febrile disease that could complement current disease surveillance systems. Because temperature can easily be measured by non-experts, it might also be suitable for monitoring febrile disease activity in schools, workplaces, and transportation hubs, where many traditional syndromic indicators are impractical. However, the system’s validity and generalizability should be evaluated in additional years and settings.
- 25 February 2011
- Published by Wiley in Academic Emergency Medicine
- Vol. 18 (3) , 317-321
Effect of Two Different FDA-approved D-dimer Assays on Resource Utilization in the Emergency Department
The D-dimer assay has been shown to be an appropriate test to rule out pulmonary embolism (PE) in low-risk patients in the emergency department (ED). Multiple assays now are approved to measure D-dimer levels. Studies have shown a newer assay, Tina-quant, to have similar diagnostic accuracy to the VIDAS assay. The objective was to determine effects of transitioning from the VIDAS assay to the Tina-quant D-dimer assay on the need for computed tomography angiogram (CTA) and ED length of stay (LOS) in patients being evaluated for PE in the ED. A retrospective cohort study was conducted of patients who had D-dimer levels ordered at an urban, academic, Level I trauma center with over 55,000 annual ED visits. The results of D-dimer levels in the ED were recorded over a period of 6 months prior to and 6 months after the transition to the new D-dimer assay. The numbers of positive and negative D-dimers and need for subsequent CTAs were recorded for comparison. LOS was also recorded to determine time saved. Medians were calculated and compared using Wilcoxon rank sum. During the initial period, 875 D-dimers were ordered, with a positive rate of 41.5%. During the period after the introduction of the Tina-quant assay, 859 tests were ordered, with 25.5% having positive results. An absolute decrease of 16% in the number of necessary CTAs (p < 0.003) was seen after the transition to the Tina-quant assay. LOS data showed a mean LOS of 481 minutes in the ED for patients who underwent testing with the Tina-quant assay compared to 526 minutes with the VIDAS assay, saving an average of 45 minutes per patient (p < 0.003). The positive rate on performed imaging studies for D-dimer of > 500 rose from 13 of 308 (4.2%) to 17 of 187 (9.1%). Switching D-dimer assays reduced both LOS and number of imaging studies in our patient population.
- 25 February 2011
- Published by Wiley in Academic Emergency Medicine
- Vol. 18 (3) , 317-321
Effect of Two Different FDA-approved D-dimer Assays on Resource Utilization in the Emergency Department
The D-dimer assay has been shown to be an appropriate test to rule out pulmonary embolism (PE) in low-risk patients in the emergency department (ED). Multiple assays now are approved to measure D-dimer levels. Studies have shown a newer assay, Tina-quant, to have similar diagnostic accuracy to the VIDAS assay. The objective was to determine effects of transitioning from the VIDAS assay to the Tina-quant D-dimer assay on the need for computed tomography angiogram (CTA) and ED length of stay (LOS) in patients being evaluated for PE in the ED. A retrospective cohort study was conducted of patients who had D-dimer levels ordered at an urban, academic, Level I trauma center with over 55,000 annual ED visits. The results of D-dimer levels in the ED were recorded over a period of 6 months prior to and 6 months after the transition to the new D-dimer assay. The numbers of positive and negative D-dimers and need for subsequent CTAs were recorded for comparison. LOS was also recorded to determine time saved. Medians were calculated and compared using Wilcoxon rank sum. During the initial period, 875 D-dimers were ordered, with a positive rate of 41.5%. During the period after the introduction of the Tina-quant assay, 859 tests were ordered, with 25.5% having positive results. An absolute decrease of 16% in the number of necessary CTAs (p < 0.003) was seen after the transition to the Tina-quant assay. LOS data showed a mean LOS of 481 minutes in the ED for patients who underwent testing with the Tina-quant assay compared to 526 minutes with the VIDAS assay, saving an average of 45 minutes per patient (p < 0.003). The positive rate on performed imaging studies for D-dimer of > 500 rose from 13 of 308 (4.2%) to 17 of 187 (9.1%). Switching D-dimer assays reduced both LOS and number of imaging studies in our patient population.