David Masters
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Masters has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Sedunov
Department of Civil, Environmental & Ocean Engineering, Stevens Institute of Technology, Hoboken, NJ 07030, USA
3 shared publications - Alexander Sutin
Department of Civil, Environmental & Ocean Engineering, Stevens Institute of Technology, Hoboken, NJ 07030, USA
2 shared publications - Hady Salloum
Stevens Inst. of Technol., 711 Hudson St., Hoboken, NJ 07030
2 shared publications Nikolay Sedunov
Maritime Security Ctr., Stevens Inst. of Technol., One Castle Point on Hudson, Hoboken, NJ 07030
2 shared publications- Yegor Sinelnikov
Stevens Institute of Technology, Hoboken, NJ, USA;;;;
2 shared publications - Alexander Sutin
Acoust., Stevens Inst. of Technol., Hoboken, NJ
1 shared publication
Latest Publications
- 1 October 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (4_Suppleme) , 2555
Detection localization and tracking of aircraft using Sparse distributed passive acoustic system
Stevens Institute of Technology has conducted extensive long-term testing of acoustic systems designed to track low-flying small aircraft in remote location and recorded over 2 years of data. The system consisted of 4 nodes placed in difficult remote terrain with separation ranging 1–4 km, each node comprising a pyramid-shaped volumetric cluster of 5 microphones an embedded computer, and a pan-tilt-zoom camera steered to detected targets in real time. and communication device. Each nodes' computer performed direction of arrival finding communicated to a central computer collected that data and processed it to generate tracks and classify targets. The duration and the scale of the deployment allowed to identify and solve many problems, including the effects of propagation delays between station and on cooperative localization and tracking, the seasonal changes in environmental noise, persistent and transient noise sources, and the diversity of targets of opportunity and their signatures. The propagation delay effects led to development of separate trackers for review of target trajectories and for immediate action such as steering the camera. An overview of the algorithms is presented along with the long-term observations. [This work was funded by DHS’s S&T Directorate.]
- 1 October 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (4_Suppleme) , 2555
Detection localization and tracking of aircraft using Sparse distributed passive acoustic system
Stevens Institute of Technology has conducted extensive long-term testing of acoustic systems designed to track low-flying small aircraft in remote location and recorded over 2 years of data. The system consisted of 4 nodes placed in difficult remote terrain with separation ranging 1–4 km, each node comprising a pyramid-shaped volumetric cluster of 5 microphones an embedded computer, and a pan-tilt-zoom camera steered to detected targets in real time. and communication device. Each nodes' computer performed direction of arrival finding communicated to a central computer collected that data and processed it to generate tracks and classify targets. The duration and the scale of the deployment allowed to identify and solve many problems, including the effects of propagation delays between station and on cooperative localization and tracking, the seasonal changes in environmental noise, persistent and transient noise sources, and the diversity of targets of opportunity and their signatures. The propagation delay effects led to development of separate trackers for review of target trajectories and for immediate action such as steering the camera. An overview of the algorithms is presented along with the long-term observations. [This work was funded by DHS’s S&T Directorate.]
- 1 January 2016
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 25 (1) , 010005
Mice ultrasonic detection and localization in laboratory environment
The acoustic detection and localization of mice movement by monitoring their ultrasonicvocalization has been demonstrated in laboratory environment using ultrasonic system with three microphones that provides recording of ultrasound up to 120 kHz. The tests were approved by Stony Brook University Institutional Animal Care and Use Committee protocol. Signals were recorded in a set of discrete sequences over several hours. The locomotor activity was characterized by durations up to 3000 ms and wide spectral content, while the syllable vocalization constituted shorter 200 ms events, with a set of identifiable up and down frequency modulated tones between 3 kHz and 55 kHz. The Time Difference of Arrival (TDOA) to various microphones was calculated using cross correlation method and was applied for estimation for mice location. Mice are among the invasive species that have a potential of crossing borders of USA unnoticed in containers. This study demonstrates the feasibility of using acoustic methods for detection of potential rodent intrusions. This work was sponsored by DHS S&T.
- 1 January 2016
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 25 (1) , 010005
Mice ultrasonic detection and localization in laboratory environment
The acoustic detection and localization of mice movement by monitoring their ultrasonicvocalization has been demonstrated in laboratory environment using ultrasonic system with three microphones that provides recording of ultrasound up to 120 kHz. The tests were approved by Stony Brook University Institutional Animal Care and Use Committee protocol. Signals were recorded in a set of discrete sequences over several hours. The locomotor activity was characterized by durations up to 3000 ms and wide spectral content, while the syllable vocalization constituted shorter 200 ms events, with a set of identifiable up and down frequency modulated tones between 3 kHz and 55 kHz. The Time Difference of Arrival (TDOA) to various microphones was calculated using cross correlation method and was applied for estimation for mice location. Mice are among the invasive species that have a potential of crossing borders of USA unnoticed in containers. This study demonstrates the feasibility of using acoustic methods for detection of potential rodent intrusions. This work was sponsored by DHS S&T.
- 1 September 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (3_Suppleme) , 1791
Mice ultrasonic detection and localization in laboratory environment
The acoustic detection and localization of mice movement by monitoring their ultrasonic vocalization has been demonstrated in laboratory environment using ultrasonic system with three microphones that provides recording of ultrasound up to 120 kHz. The tests were approved by Stony Brook University Institutional Animal Care and Use Committee protocol. Signals were recorded in a set of discrete sequences over several hours. The locomotor activity was characterized by durations up to 3000 ms and wide spectral content, while the syllable vocalization constituted shorter 200 ms events, with a set of identifiable up and down frequency modulated tones between 3 kHz and 55 kHz. The Time Difference of Arrival (TDOA) to various microphones was calculated using cross correlation method and was applied for estimation for mice location. Mice are among the invasive species that have a potential of crossing borders of United States unnoticed in containers. This study demonstrates the feasibility of using acoustic methods for detection of potential rodent intrusions. [This work was sponsored by DHS S&T.]
- 1 September 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (3_Suppleme) , 1791
Mice ultrasonic detection and localization in laboratory environment
The acoustic detection and localization of mice movement by monitoring their ultrasonic vocalization has been demonstrated in laboratory environment using ultrasonic system with three microphones that provides recording of ultrasound up to 120 kHz. The tests were approved by Stony Brook University Institutional Animal Care and Use Committee protocol. Signals were recorded in a set of discrete sequences over several hours. The locomotor activity was characterized by durations up to 3000 ms and wide spectral content, while the syllable vocalization constituted shorter 200 ms events, with a set of identifiable up and down frequency modulated tones between 3 kHz and 55 kHz. The Time Difference of Arrival (TDOA) to various microphones was calculated using cross correlation method and was applied for estimation for mice location. Mice are among the invasive species that have a potential of crossing borders of United States unnoticed in containers. This study demonstrates the feasibility of using acoustic methods for detection of potential rodent intrusions. [This work was sponsored by DHS S&T.]