Ekadewi Anggraini Handoyo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ekadewi Anggraini Handoyo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Amelia
Department of Mechanical Engineering, Petra Christian University, Indonesia
1 shared publicationAndriono Slamet
Mechanical Engineering Department, Petra Christian University, Jl. Siwalankerto No.121–131 Surabaya 60236, Indonesia
1 shared publicationAnik Juniwati
Fakultas Teknik Sipil dan Perencanaan Fakultas Teknik Sipil dan Perencanaan Teknik Mesin Fakultas Teknik Industri di Surabaya. Hasil penelitian menunjukkan bahwa EAHE Universitas Kristen Petra Surabaya Universitas Kristen Petra Surabaya Universitas Kristen Petra Surabaya
1 shared publicationAntonio Hazman
Mechanical Engineering Department – Petra Christian University, Indonesia
1 shared publicationArchie G K Maxwell
Graduate School of Science and Technology, Sophia University , 7-1, Kioi-cho, Chiyoda-ku, Tokyo, 102-8554 , Japan
1 shared publicationChristian Ivan Soeyanto
Department of Mechanical Engineering, Petra Christian University, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 February 2025
- Published by LPPM ITN Malang in Pawon: Jurnal Arsitektur
- Vol. 9 (01) , 141-150
OPTIMASI EAHE SEBAGAI UPAYA PENDINGIN RUANG SIANG HARI DI SURABAYA
ABSTRAK Tinggal dan beraktifitas dalam lingkungan bersuhu tinggi di iklim tropis lembab meningkatkan risiko dehidrasi, menurunkan konsentrasi, kelelahan, menimbulkan masalah kesehatan dan menurunkan produktivitas. Upaya pendinginan pasif dengan ventilasi alami sering kali tidak efektif karena suhu tinggi, kelembaban, radiasi matahari, serta kecepatan angin yang tidak mendukung. Sedang meningkatkan kecepatan angin akan mengganggu aktifitas. Salah satu solusi untuk pendinginan adalah dengan memindahkan panas udara ke tanah, atau dikenal sebagai Earth-to-Air Heat Exchanger (EAHE). Penelitian ini merupakan eksperimental studi lanjutan untuk mendapatkan optimasi model EAHE di siang hari di Surabaya. Hasilnya menunjukkan bahwa EAHE efektif menurunkan suhu ruang hingga 2ºC. Angka ini cukup signifikan untuk dipakai sebagai pendinginan ruang. Kajian lebih lanjut diperlukan untuk menentukan kebutuhan udara dingin yang proporsional dengan volume ruang. Kata kunci: Kenyamanan Termal, Ventilasi, Pendinginan Udara, EAHE ABSTRACT People living and working in high-temperature environments are prone to dehydration, reduced concentration, and fatigue, leading to health issues and decreased productivity. Passive cooling through natural ventilation is often ineffective in humid tropical cities due to high temperatures, humidity, and low wind speeds, while high wind speeds can disrupt activities. Earth-to-Air Heat Exchanger (EAHE) systems provide a cooling solution by transferring air heat to the ground. This experimental study on ventilation using EAHE is an optimization EAHE model on daytime in Surabaya. The result showed that EAHE reduced room temperatures by up to 2ºC during the day. This confirms EAHE’s potential for cooling applications. Further research is needed to optimize the required air volume for effective space cooling. Keywords: Thermal comfort, ventilation, air-cooling, EAHE
- 1 February 2025
- Published by LPPM ITN Malang in Pawon: Jurnal Arsitektur
- Vol. 9 (01) , 141-150
Open AccessOPTIMASI EAHE SEBAGAI UPAYA PENDINGIN RUANG SIANG HARI DI SURABAYA
ABSTRAK Tinggal dan beraktifitas dalam lingkungan bersuhu tinggi di iklim tropis lembab meningkatkan risiko dehidrasi, menurunkan konsentrasi, kelelahan, menimbulkan masalah kesehatan dan menurunkan produktivitas. Upaya pendinginan pasif dengan ventilasi alami sering kali tidak efektif karena suhu tinggi, kelembaban, radiasi matahari, serta kecepatan angin yang tidak mendukung. Sedang meningkatkan kecepatan angin akan mengganggu aktifitas. Salah satu solusi untuk pendinginan adalah dengan memindahkan panas udara ke tanah, atau dikenal sebagai Earth-to-Air Heat Exchanger (EAHE). Penelitian ini merupakan eksperimental studi lanjutan untuk mendapatkan optimasi model EAHE di siang hari di Surabaya. Hasilnya menunjukkan bahwa EAHE efektif menurunkan suhu ruang hingga 2ºC. Angka ini cukup signifikan untuk dipakai sebagai pendinginan ruang. Kajian lebih lanjut diperlukan untuk menentukan kebutuhan udara dingin yang proporsional dengan volume ruang. Kata kunci: Kenyamanan Termal, Ventilasi, Pendinginan Udara, EAHE ABSTRACT People living and working in high-temperature environments are prone to dehydration, reduced concentration, and fatigue, leading to health issues and decreased productivity. Passive cooling through natural ventilation is often ineffective in humid tropical cities due to high temperatures, humidity, and low wind speeds, while high wind speeds can disrupt activities. Earth-to-Air Heat Exchanger (EAHE) systems provide a cooling solution by transferring air heat to the ground. This experimental study on ventilation using EAHE is an optimization EAHE model on daytime in Surabaya. The result showed that EAHE reduced room temperatures by up to 2ºC during the day. This confirms EAHE’s potential for cooling applications. Further research is needed to optimize the required air volume for effective space cooling. Keywords: Thermal comfort, ventilation, air-cooling, EAHE
- Open Access
- 1 March 2024
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 8 (2) , 48-59
Experimental study on the effect of micro-carbon additives in vegetable oils for aquifer thermal energy storage
Aquifer thermal energy storage is a versatile method for regulating building temperatures, utilizing groundwater as a medium for both summer cooling and winter heating. Water has high thermal conductivity and specific heat but is corrosive, creating a mineral build-up that causes scaling. Additionally, its high freezing point presents operational challenges. Vegetable oils emerge as a promising alternative, owing to their lower freezing points. In light of environmental concerns, researchers are exploring vegetable oils as substitutes for petroleum-derived mineral oils. This paper is intended as an initial study using vegetable oils, i.e. coconut and sunflower oil, as the heat-transfer medium in aquifer thermal energy storage. The experiments assess the heat-transfer coefficient of coconut, sunflower, mineral, and synthetic oils when exposed to the same heat source. The study also evaluates the impact of introducing micro-carbon (graphite and charcoal) to the oils. Results indicate that sunflower oil has the highest heat-transfer coefficient of 374.4 W/m2 K among the oils, making it suitable for aquifer thermal energy storage applications. Furthermore, augmenting sunflower oil with charcoal powder enhances its performance by increasing the heat-transfer coefficient to 474.9 W/m2 K, or a 27% increase. In contrast, coconut oil proves unsuitable for aquifer thermal energy storage deployment because of its low heat-transfer coefficient of 293.7 W/m2 K. The heat-transfer coefficient of synthetic oil increases with graphite powder but decreases with charcoal powder introduction.
- 1 March 2024
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 8 (2) , 48-59
Open AccessExperimental study on the effect of micro-carbon additives in vegetable oils for aquifer thermal energy storage
Aquifer thermal energy storage is a versatile method for regulating building temperatures, utilizing groundwater as a medium for both summer cooling and winter heating. Water has high thermal conductivity and specific heat but is corrosive, creating a mineral build-up that causes scaling. Additionally, its high freezing point presents operational challenges. Vegetable oils emerge as a promising alternative, owing to their lower freezing points. In light of environmental concerns, researchers are exploring vegetable oils as substitutes for petroleum-derived mineral oils. This paper is intended as an initial study using vegetable oils, i.e. coconut and sunflower oil, as the heat-transfer medium in aquifer thermal energy storage. The experiments assess the heat-transfer coefficient of coconut, sunflower, mineral, and synthetic oils when exposed to the same heat source. The study also evaluates the impact of introducing micro-carbon (graphite and charcoal) to the oils. Results indicate that sunflower oil has the highest heat-transfer coefficient of 374.4 W/m2 K among the oils, making it suitable for aquifer thermal energy storage applications. Furthermore, augmenting sunflower oil with charcoal powder enhances its performance by increasing the heat-transfer coefficient to 474.9 W/m2 K, or a 27% increase. In contrast, coconut oil proves unsuitable for aquifer thermal energy storage deployment because of its low heat-transfer coefficient of 293.7 W/m2 K. The heat-transfer coefficient of synthetic oil increases with graphite powder but decreases with charcoal powder introduction.
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2951 (1)
Study and analysis of an industrial compressor facing overheat problem
A compressor in a rice manufacturer, PT. X, got overheated especially on hot days. The overheat makes the compressor shut off and stops the production line. From the observation and data collected in PT. X, it was found that the overheat problem in the compressor was caused by [1] the dust on the surface of the aftercooler and the fluid cooler, and [1] the high temperature of the intake air to the compressor. The management comprehends the suggestion to clean the coolers’ surface, close the door to the compressor room, and install an intake duct to bring in cooler air input to the compressor. Carrying out the suggestion, the overheat problem is overcome and there is saving in operational cost. The savings could be more than 4000 kWh/year for eight hours of work each day. By lowering the inlet air temperature as much as 4C° for the compressor, the CO2 emission could be reduced around 4000 kg/year. A heat exchanger could replace the after cooler and the fluid cooler for recovering the waste heat of the compressor. The heat to be recovered from the compressor is approximately 40 kW. The waste heat recovery framework will produce 13 liter/min water at 70°C.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2951 (1)
Open AccessStudy and analysis of an industrial compressor facing overheat problem
A compressor in a rice manufacturer, PT. X, got overheated especially on hot days. The overheat makes the compressor shut off and stops the production line. From the observation and data collected in PT. X, it was found that the overheat problem in the compressor was caused by [1] the dust on the surface of the aftercooler and the fluid cooler, and [1] the high temperature of the intake air to the compressor. The management comprehends the suggestion to clean the coolers’ surface, close the door to the compressor room, and install an intake duct to bring in cooler air input to the compressor. Carrying out the suggestion, the overheat problem is overcome and there is saving in operational cost. The savings could be more than 4000 kWh/year for eight hours of work each day. By lowering the inlet air temperature as much as 4C° for the compressor, the CO2 emission could be reduced around 4000 kg/year. A heat exchanger could replace the after cooler and the fluid cooler for recovering the waste heat of the compressor. The heat to be recovered from the compressor is approximately 40 kW. The waste heat recovery framework will produce 13 liter/min water at 70°C.
- Open Access
- 5 April 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 30 (2) , 60-74
Best Practice of Striving Energy Sustainability in a Hot Press Machine for Clutch Facing Manufacture
A facing clutch manufacturer in Surabaya, Indonesia, PT. X uses 20 hot press machines to produce the facings. The required heating process is provided by heat transfer oil (HTO), which is heated by natural gas burned in a heater. PT. X wants to reduce its natural gas consumption. The assessment started with checking the insulation on the piping system, measuring the temperature in the hot press machines, and measuring the HTO flow rate. The insulation in the piping system is in good condition. From the measurement, it was found that the HTO flow rate is adequate and fits the need of the heating process. Another finding is that the surface temperature of the lower plate in shaft no. 4 is the lowest than in the other shafts. The existing (asbestos) insulation from the lower bed in shaft no 4 to the hydraulic component is only 3 mm thick. This is not enough to prevent heat loss from the bed in shaft no. 4. The new 18-mm asbestos replaced the old asbestos. The replacement shows that the temperature at the mold surface at shaft no. 4 increased from 162.6°C to 170.9°C on average for MC-02 and from 166.7°C to 173.1°C on average for MC-03. Another achievement obtained is that the natural gas consumption was reduced by around 7.3% or 39 MMBtu/month, or equivalent to reducing 0.312 metric tons of CO2 per month. This is a simple effort to use less energy to protect our environment.
- 5 April 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 30 (2) , 60-74
Open AccessBest Practice of Striving Energy Sustainability in a Hot Press Machine for Clutch Facing Manufacture
A facing clutch manufacturer in Surabaya, Indonesia, PT. X uses 20 hot press machines to produce the facings. The required heating process is provided by heat transfer oil (HTO), which is heated by natural gas burned in a heater. PT. X wants to reduce its natural gas consumption. The assessment started with checking the insulation on the piping system, measuring the temperature in the hot press machines, and measuring the HTO flow rate. The insulation in the piping system is in good condition. From the measurement, it was found that the HTO flow rate is adequate and fits the need of the heating process. Another finding is that the surface temperature of the lower plate in shaft no. 4 is the lowest than in the other shafts. The existing (asbestos) insulation from the lower bed in shaft no 4 to the hydraulic component is only 3 mm thick. This is not enough to prevent heat loss from the bed in shaft no. 4. The new 18-mm asbestos replaced the old asbestos. The replacement shows that the temperature at the mold surface at shaft no. 4 increased from 162.6°C to 170.9°C on average for MC-02 and from 166.7°C to 173.1°C on average for MC-03. Another achievement obtained is that the natural gas consumption was reduced by around 7.3% or 39 MMBtu/month, or equivalent to reducing 0.312 metric tons of CO2 per month. This is a simple effort to use less energy to protect our environment.
- Open Access
- 31 December 2022
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 100 (2) , 169-180
Experimental Study on Effect of Nano ZnO on the Cooling Performance of Motorcycle Radiator
An internal combustion engine requires a proper cooling system to release heat from the engine. The working fluid or coolant in a water-cooled engine impacts the overall radiator cooling performance. Several studies show that nanopowder can increase the thermal performance of the base fluids, although the pressure drops increase significantly. This paper describes the experimental study of motorcycle radiator cooling performance using nanopowder ZnO with distilled water and commercial coolant as the base fluids. The study began by measuring the boiling point and the specific heat of the base fluid (distilled water and commercial coolant) and nanofluids. Then, the flow rate of the cooling fluid was measured as the function of the engine’s rotation speed. The results show that the boiling point of all nanofluids increases with the highest boiling point achieved by 0.5% ZnO – coolant, i.e., 110.06°C. Thus, the nanopowder will keep the cooling fluid in the liquid phase and lower the fluid's specific heat. The fluid with the lowest specific heat is nanofluid 0.5% ZnO – coolant. Low specific heat relates to the higher temperature drops. Nanofluid 0.5% ZnO – coolant has the highest temperature drop. Unfortunately, nanopowder also increases pressure drop by approximately twice the base fluid. Nanofluid 0.5% ZnO – coolant gives the highest overall heat transfer coefficient than other nanofluids or the base fluid, i.e., 42.7 W/m2.°C when its flow rate is 44.2 ml/s.
- 31 December 2022
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 100 (2) , 169-180
Open AccessExperimental Study on Effect of Nano ZnO on the Cooling Performance of Motorcycle Radiator
An internal combustion engine requires a proper cooling system to release heat from the engine. The working fluid or coolant in a water-cooled engine impacts the overall radiator cooling performance. Several studies show that nanopowder can increase the thermal performance of the base fluids, although the pressure drops increase significantly. This paper describes the experimental study of motorcycle radiator cooling performance using nanopowder ZnO with distilled water and commercial coolant as the base fluids. The study began by measuring the boiling point and the specific heat of the base fluid (distilled water and commercial coolant) and nanofluids. Then, the flow rate of the cooling fluid was measured as the function of the engine’s rotation speed. The results show that the boiling point of all nanofluids increases with the highest boiling point achieved by 0.5% ZnO – coolant, i.e., 110.06°C. Thus, the nanopowder will keep the cooling fluid in the liquid phase and lower the fluid's specific heat. The fluid with the lowest specific heat is nanofluid 0.5% ZnO – coolant. Low specific heat relates to the higher temperature drops. Nanofluid 0.5% ZnO – coolant has the highest temperature drop. Unfortunately, nanopowder also increases pressure drop by approximately twice the base fluid. Nanofluid 0.5% ZnO – coolant gives the highest overall heat transfer coefficient than other nanofluids or the base fluid, i.e., 42.7 W/m2.°C when its flow rate is 44.2 ml/s.
- Open Access
- 15 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 130, 01007
Experimental Analysis on Solid Desiccant Used in An Air Conditioning
Garden by The Bay in Singapore is the world’s largest coolest conservatories. Although it is located in tropics and uses so many glasses, its electricity consumption is as much as a commercial building. The key to this low consumption is in air cooling technology. Air used for cooling the conservatories is dehumidified first using liquid desiccants before cooled. The same technology was implemented to a single-split air conditioner (AC) that works on a vapor-compression refrigeration cycle. The experiments were conducted in a room with opened and closed door. Instead of using a liquid desiccant, the experiment used a solid desiccant, i.e., silica gel which thickness was 6 mm and 8 mm with density equals to 1.27 gr cm–3. From the experiment, it is found that: (i) the thicker the silica gel, the higher outlet air temperature from silica gel, (ii) less condensate will be produced when the silica gel used is thicker, (iii) silica gel is suitable for reducing humidity of outdoor/fresh air, and (iv) the electricity consumption saving for inserting 8 mm silica gel is only 4 % when the door is closed and 31 % when the door is opened.
- 15 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 130, 01007
Open AccessExperimental Analysis on Solid Desiccant Used in An Air Conditioning
Garden by The Bay in Singapore is the world’s largest coolest conservatories. Although it is located in tropics and uses so many glasses, its electricity consumption is as much as a commercial building. The key to this low consumption is in air cooling technology. Air used for cooling the conservatories is dehumidified first using liquid desiccants before cooled. The same technology was implemented to a single-split air conditioner (AC) that works on a vapor-compression refrigeration cycle. The experiments were conducted in a room with opened and closed door. Instead of using a liquid desiccant, the experiment used a solid desiccant, i.e., silica gel which thickness was 6 mm and 8 mm with density equals to 1.27 gr cm–3. From the experiment, it is found that: (i) the thicker the silica gel, the higher outlet air temperature from silica gel, (ii) less condensate will be produced when the silica gel used is thicker, (iii) silica gel is suitable for reducing humidity of outdoor/fresh air, and (iv) the electricity consumption saving for inserting 8 mm silica gel is only 4 % when the door is closed and 31 % when the door is opened.
- Open Access
- 23 April 2019
- Published by Indonesian Mechanical Engineering Cooperation Agency in Jurnal Teknik Mesin Indonesia
- Vol. 14 (1) , 19-23
Design of heat exchanger for cooling fluid used on magnetic induction welder
Magnetic induction welding is a common process in pipe production. The impeder used in the welding machine needs to be cooled to maintain its temperature below 35oC. The cooling fluid is water with 2% cutting oil and called coolant. It should enter the impeder at 15oC. The required flow rate is as much as 30 lt/min. To ensure the impeder’s temperature be kept lower than required temperature, then the heat exchanger shall be designed to cool the coolant from 40oC to 15oC. Air-cooled water chiller type UWAP750AY3 is used to produce chilled water needed by the heat exchanger. The 5/8-inch-finned-copper pipes are used as tubes in the heat exchanger. The coolant is divided in four equally tubes from a header. To meet the heat transfer area needed, each tubes will be bent to make 10 passes (or rows). At the end of the last row, four flow will be gathered in a header. Then, the coolant will circulate to impeder with the required temperature. Numerical simulation was conducted to get the velocity vector and temperature distribution of flow inside the tube, and also the pressure drop of the flow across the tubes and header. Velocity vector of flow around return bend, flow in entrance and exit are interesting. They give understanding that the pressure drop will be higher in such accessories than in straight pipe. The pressure drop of coolant flowing inside tubes of heat exchanger is 5143.2 Pa from analytical solutions and 4611.4 Pa from numerical simulation using Fluent. Temperature of coolant at outlet got from numerical simulation is almost the same with the designed temperature, i.e. 15oC. So, the numerical simulation reinforces the design of the heat exchanger.
- 23 April 2019
- Published by Indonesian Mechanical Engineering Cooperation Agency in Jurnal Teknik Mesin Indonesia
- Vol. 14 (1) , 19-23
Open AccessDesign of heat exchanger for cooling fluid used on magnetic induction welder
Magnetic induction welding is a common process in pipe production. The impeder used in the welding machine needs to be cooled to maintain its temperature below 35oC. The cooling fluid is water with 2% cutting oil and called coolant. It should enter the impeder at 15oC. The required flow rate is as much as 30 lt/min. To ensure the impeder’s temperature be kept lower than required temperature, then the heat exchanger shall be designed to cool the coolant from 40oC to 15oC. Air-cooled water chiller type UWAP750AY3 is used to produce chilled water needed by the heat exchanger. The 5/8-inch-finned-copper pipes are used as tubes in the heat exchanger. The coolant is divided in four equally tubes from a header. To meet the heat transfer area needed, each tubes will be bent to make 10 passes (or rows). At the end of the last row, four flow will be gathered in a header. Then, the coolant will circulate to impeder with the required temperature. Numerical simulation was conducted to get the velocity vector and temperature distribution of flow inside the tube, and also the pressure drop of the flow across the tubes and header. Velocity vector of flow around return bend, flow in entrance and exit are interesting. They give understanding that the pressure drop will be higher in such accessories than in straight pipe. The pressure drop of coolant flowing inside tubes of heat exchanger is 5143.2 Pa from analytical solutions and 4611.4 Pa from numerical simulation using Fluent. Temperature of coolant at outlet got from numerical simulation is almost the same with the designed temperature, i.e. 15oC. So, the numerical simulation reinforces the design of the heat exchanger.
- Open Access
- 10 December 2018
- Published by EDP Sciences in SHS Web of Conferences
- Vol. 59, 01009
The Impact of Service Learning at Kebontunggul Village for The Students of Heat Transfer Class
Service learning is new for engineering students in PCU. When heat transfer class was adopting service learning methode last year, a small survey was done to know the students’ respond for this new methode. The survey was done via reflection they wrote in the end of the process. The students learn not only heat transfer itself, but they also learn how to apply it to an oven needed by a community in Kebontunggul, a small village in Mojokerto. The students in three groups visited the village, discussed with the villagers, and designed the oven used to dry crackers’ paste made from corn, cassava, and rice flour. Once the design was ready, the students went to workshop to manufacture the ovens. The oven was tested before sent to the village. They learned that it was difficult to make those cheap crackers. They learned a lot from the villagers in social interpersonal, social intrapersonal, emotional, and cognitive process. They are thankful to God for their being and grateful for this Service Learning class. A student even wrote, “I had changed motivation from just pursuing grade to seriously helping villagers”.
- 10 December 2018
- Published by EDP Sciences in SHS Web of Conferences
- Vol. 59, 01009
Open AccessThe Impact of Service Learning at Kebontunggul Village for The Students of Heat Transfer Class
Service learning is new for engineering students in PCU. When heat transfer class was adopting service learning methode last year, a small survey was done to know the students’ respond for this new methode. The survey was done via reflection they wrote in the end of the process. The students learn not only heat transfer itself, but they also learn how to apply it to an oven needed by a community in Kebontunggul, a small village in Mojokerto. The students in three groups visited the village, discussed with the villagers, and designed the oven used to dry crackers’ paste made from corn, cassava, and rice flour. Once the design was ready, the students went to workshop to manufacture the ovens. The oven was tested before sent to the village. They learned that it was difficult to make those cheap crackers. They learned a lot from the villagers in social interpersonal, social intrapersonal, emotional, and cognitive process. They are thankful to God for their being and grateful for this Service Learning class. A student even wrote, “I had changed motivation from just pursuing grade to seriously helping villagers”.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 020001
Optimization of wire drawing die’s cooling system
Wire drawing die wear is measured by the dilatation of die gap diameter. Many factors that contribute to wire drawing die wear, one of them is temperature of the wire during drawing process. Therefore, die cooling system have to be considered to reduce die wear. Water that is cooled by cooling tower is usually used as die coolant. If the heat is not transferred well to the coolant, then the die wear will happen faster and the die needs replacement more often. ASM International gives suggestion to maintain the die gap or the wire’s temperature at 137°C during drawing process. At this temperature, die wear will be 0.01 mm for 500 km of drawing wire that contains 0.08 % Carbon. In a wire company that produces AISI 1010, wire was drawn from diameter 5.5 mm to 4.75 mm and die wear was 0.05 mm for 332.1 km of drawing wire. This die wear showed the existing die cooling system was not enough. Assessment of existing cooling system and numerical simulation were conducted to find solution. From the assessment, the cooling tower’s average effectiveness was only 25.9%. Numerical simulation using Gambit, ANSYS Workbench, and ANSYS Fluent was conducted to obtain die gap surface temperature and some improvement of the cooling system. The mesh used in simulation is 0.7 mm interval and Standard K-Epsilon (SKE) is chosen as the viscous model. From the simulation, die gap or wire temperature was found 159.3°C. This value is much higher than 137°C that is recommended by ASM International. Some improvement proposed to the existing cooling system are: 1) Replacing the cooling tower or using water chiller to produce water flowing into die box at rate of at least 0.332 l/s and maximum temperature of 25°C; 2) Changing the die box shape into cylindrical shape.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 020001
Optimization of wire drawing die’s cooling system
Wire drawing die wear is measured by the dilatation of die gap diameter. Many factors that contribute to wire drawing die wear, one of them is temperature of the wire during drawing process. Therefore, die cooling system have to be considered to reduce die wear. Water that is cooled by cooling tower is usually used as die coolant. If the heat is not transferred well to the coolant, then the die wear will happen faster and the die needs replacement more often. ASM International gives suggestion to maintain the die gap or the wire’s temperature at 137°C during drawing process. At this temperature, die wear will be 0.01 mm for 500 km of drawing wire that contains 0.08 % Carbon. In a wire company that produces AISI 1010, wire was drawn from diameter 5.5 mm to 4.75 mm and die wear was 0.05 mm for 332.1 km of drawing wire. This die wear showed the existing die cooling system was not enough. Assessment of existing cooling system and numerical simulation were conducted to find solution. From the assessment, the cooling tower’s average effectiveness was only 25.9%. Numerical simulation using Gambit, ANSYS Workbench, and ANSYS Fluent was conducted to obtain die gap surface temperature and some improvement of the cooling system. The mesh used in simulation is 0.7 mm interval and Standard K-Epsilon (SKE) is chosen as the viscous model. From the simulation, die gap or wire temperature was found 159.3°C. This value is much higher than 137°C that is recommended by ASM International. Some improvement proposed to the existing cooling system are: 1) Replacing the cooling tower or using water chiller to produce water flowing into die box at rate of at least 0.332 l/s and maximum temperature of 25°C; 2) Changing the die box shape into cylindrical shape.