Bone Siu-Fai Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bone Siu-Fai Tang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Edmond Shiu Kwan Ma
Department of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
2 shared publications - Jonpaul St Zee
Department of Pathology, Hong Kong Sanatorium & Hospital, Hong Kong; Infection Control Team, Hong Kong Sanatorium & Hospital, Hong Kong
2 shared publications Anthony Tsz-Chun Wong
Department of Pathology, Hong Kong Sanatorium & Hospital, Hong Kong, HKSAR
1 shared publicationC. K.-C. Lai
Department of Pathology, Queen Elizabeth Hospital, Hong Kong, China
1 shared publicationCandy C. Y. Lau
Department of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong, China
1 shared publication- Chin-Pang Leung
Department of Pathology, Hong Kong Sanatorium & Hospital, Hong Kong SAR, China
1 shared publication
Latest Publications
- Open Access
Clinical Evaluation of the BIOFIRE SPOTFIRE Respiratory Panel
The BIOFIRE SPOTFIRE Respiratory (R) Panel is a novel, in vitro diagnostic PCR assay with 15 pathogen targets. The runtime is about 15 min which is the shortest among similar panels in the market. We evaluated the performance of the SPOTFIRE R Panel with 151 specimens, including 133 collected from the upper respiratory tract (URT), 13 from the lower respiratory tract (LRT) and 5 external quality assessment program (EQAP) samples. The respiratory specimens were enrolled throughout the first two post-COVID-19 influenza seasons in Hong Kong (March to December 2023). For URT specimens, full concordance was observed between the SPOTFIRE R Panel and the standard-of-care FilmArray Respiratory 2.1 plus Panel (RP2.1plus) for 109 specimens (109/133, 81.95%). After discrepant analysis, the SPOTFIRE R Panel identified more pathogens than the RP2.1plus in 15 specimens and vice versa in 3 specimens. The per-target negative and positive percentage agreement (NPA and PPA) were 92.86–100% except the PPA of adenovirus (88.24%). For LRT and EQAP samples, all results were fully concordant. To conclude, the performance of the SPOTFIRE R Panel was comparable to the RP2.1plus.
Open AccessClinical Evaluation of the BIOFIRE SPOTFIRE Respiratory Panel
The BIOFIRE SPOTFIRE Respiratory (R) Panel is a novel, in vitro diagnostic PCR assay with 15 pathogen targets. The runtime is about 15 min which is the shortest among similar panels in the market. We evaluated the performance of the SPOTFIRE R Panel with 151 specimens, including 133 collected from the upper respiratory tract (URT), 13 from the lower respiratory tract (LRT) and 5 external quality assessment program (EQAP) samples. The respiratory specimens were enrolled throughout the first two post-COVID-19 influenza seasons in Hong Kong (March to December 2023). For URT specimens, full concordance was observed between the SPOTFIRE R Panel and the standard-of-care FilmArray Respiratory 2.1 plus Panel (RP2.1plus) for 109 specimens (109/133, 81.95%). After discrepant analysis, the SPOTFIRE R Panel identified more pathogens than the RP2.1plus in 15 specimens and vice versa in 3 specimens. The per-target negative and positive percentage agreement (NPA and PPA) were 92.86–100% except the PPA of adenovirus (88.24%). For LRT and EQAP samples, all results were fully concordant. To conclude, the performance of the SPOTFIRE R Panel was comparable to the RP2.1plus.
- Open Access
Safety and Immunogenicity of a Booster Vaccination by CoronaVac or BNT162b2 in Previously Two-Dose Inactivated Virus Vaccinated Individuals with Negative Neutralizing Antibody
COVID-19 has swept across the globe since 2019 and repeated waves of infection have been caused by different variants of the original SARS-CoV-2 (wild type), with the Omicron and Delta variants having dominated recently. Vaccination is among the most important measures in the absence of widespread use of antivirals for prevention of morbidity and mortality. Inactivated virus vaccine has been abundantly used in many countries as the primary two-dose regimen. We aim to study the safety and immunogenicity of CoronaVac (three-dose inactivated virus vaccine) and the BNT162b2 (two-dose inactivated virus vaccine followed by an mRNA vaccine) booster. Both CoronaVac and BNT162b2 boosters are generally safe and have good immunogenicity against the wild type SARS-CoV-2 and the Delta variant with the majority having neutralizing antibodies (NAb) on day 30 and day 90. However, the BNT162b2 booster is associated with a much higher proportion of positive NAb against the Omicron variant. Only 8% of day 30 and day 90 samples post CoronaVac booster have NAb against the Omicron variant. In addition, more BNT162b2 booster recipients are having positive T-cell responses using interferon gamma release assay. In places using inactivated virus vaccine as the primary two-dose scheme, the heterologous mRNA vaccine booster is safe and more immunogenic against the Omicron variant and should be considered as a preferred option during the current outbreak.
Open AccessSafety and Immunogenicity of a Booster Vaccination by CoronaVac or BNT162b2 in Previously Two-Dose Inactivated Virus Vaccinated Individuals with Negative Neutralizing Antibody
COVID-19 has swept across the globe since 2019 and repeated waves of infection have been caused by different variants of the original SARS-CoV-2 (wild type), with the Omicron and Delta variants having dominated recently. Vaccination is among the most important measures in the absence of widespread use of antivirals for prevention of morbidity and mortality. Inactivated virus vaccine has been abundantly used in many countries as the primary two-dose regimen. We aim to study the safety and immunogenicity of CoronaVac (three-dose inactivated virus vaccine) and the BNT162b2 (two-dose inactivated virus vaccine followed by an mRNA vaccine) booster. Both CoronaVac and BNT162b2 boosters are generally safe and have good immunogenicity against the wild type SARS-CoV-2 and the Delta variant with the majority having neutralizing antibodies (NAb) on day 30 and day 90. However, the BNT162b2 booster is associated with a much higher proportion of positive NAb against the Omicron variant. Only 8% of day 30 and day 90 samples post CoronaVac booster have NAb against the Omicron variant. In addition, more BNT162b2 booster recipients are having positive T-cell responses using interferon gamma release assay. In places using inactivated virus vaccine as the primary two-dose scheme, the heterologous mRNA vaccine booster is safe and more immunogenic against the Omicron variant and should be considered as a preferred option during the current outbreak.
- Open Access
- 18 December 2021
- Published by Springer Nature in BMC Microbiology
- Vol. 21 (1) , 1-15
Comparison of novel rapid diagnostic of blood culture identification and antimicrobial susceptibility testing by Accelerate Pheno system and BioFire FilmArray Blood Culture Identification and BioFire FilmArray Blood Culture Identification 2 panels
Background: Conventional turnaround time (TAT) for positive blood culture (PBC) identification (ID) and antimicrobial susceptibility testing (AST) is 2–3 days. We evaluated the TAT and ID/AST performance using clinical and seeded samples directly from PBC bottles with different commercial approaches: (1) Accelerate Pheno® system (Pheno) for ID/AST; (2) BioFire® FilmArray® Blood Culture Identification (BCID) Panel and/ or BCID2 for ID; (3) direct AST by VITEK® 2 (direct AST); and (4) overnight culture using VITEK® 2 colony AST.Results: A total of 141 PBC samples were included in this evaluation. Using MALDI-TOF (Bruker MALDI Biotyper) as the reference method for ID, the overall monomicrobial ID sensitivity/specificity are as follows: Pheno 97.9/99.9%; BCID 100/100%; and BCID2 100/100%, respectively. For AST performance, broth microdilution (BMD) was used as the reference method. For gram-negatives, overall categorical and essential agreements (CA/EA) for each method were: Pheno 90.3/93.2%; direct AST 92.6/88.5%; colony AST 94.4/89.5%, respectively. For gram-positives, the overall CA/EAs were as follows: Pheno 97.2/98.89%; direct AST 97.2/100%; colony AST 97.2/100%, respectively. The BCID/BCID2 and direct AST TATs were around 9–20 h (1/9-19 h for ID with resistance markers/AST), with 15 min/sample hands-on time. In comparison, Pheno TATs were around 8–10 h (1.5/7 h for ID/AST) with 2 min/sample hands-on time, maintains a clinically relevant fast report of antibiotic minimal inhibitory concentration (MIC) and allows for less TAT and hands-on time.Conclusion: In conclusion, to the best of our knowledge, this is the first study conducted as such in Asia; all studied approaches achieved satisfactory performance, factors such as TAT, panel of antibiotics choices and hands-on time should be considered for the selection of appropriate rapid ID and AST of PBC methods in different laboratory settings.
- 18 December 2021
- Published by Springer Nature in BMC Microbiology
- Vol. 21 (1) , 1-15
Open AccessComparison of novel rapid diagnostic of blood culture identification and antimicrobial susceptibility testing by Accelerate Pheno system and BioFire FilmArray Blood Culture Identification and BioFire FilmArray Blood Culture Identification 2 panels
Background: Conventional turnaround time (TAT) for positive blood culture (PBC) identification (ID) and antimicrobial susceptibility testing (AST) is 2–3 days. We evaluated the TAT and ID/AST performance using clinical and seeded samples directly from PBC bottles with different commercial approaches: (1) Accelerate Pheno® system (Pheno) for ID/AST; (2) BioFire® FilmArray® Blood Culture Identification (BCID) Panel and/ or BCID2 for ID; (3) direct AST by VITEK® 2 (direct AST); and (4) overnight culture using VITEK® 2 colony AST.Results: A total of 141 PBC samples were included in this evaluation. Using MALDI-TOF (Bruker MALDI Biotyper) as the reference method for ID, the overall monomicrobial ID sensitivity/specificity are as follows: Pheno 97.9/99.9%; BCID 100/100%; and BCID2 100/100%, respectively. For AST performance, broth microdilution (BMD) was used as the reference method. For gram-negatives, overall categorical and essential agreements (CA/EA) for each method were: Pheno 90.3/93.2%; direct AST 92.6/88.5%; colony AST 94.4/89.5%, respectively. For gram-positives, the overall CA/EAs were as follows: Pheno 97.2/98.89%; direct AST 97.2/100%; colony AST 97.2/100%, respectively. The BCID/BCID2 and direct AST TATs were around 9–20 h (1/9-19 h for ID with resistance markers/AST), with 15 min/sample hands-on time. In comparison, Pheno TATs were around 8–10 h (1.5/7 h for ID/AST) with 2 min/sample hands-on time, maintains a clinically relevant fast report of antibiotic minimal inhibitory concentration (MIC) and allows for less TAT and hands-on time.Conclusion: In conclusion, to the best of our knowledge, this is the first study conducted as such in Asia; all studied approaches achieved satisfactory performance, factors such as TAT, panel of antibiotics choices and hands-on time should be considered for the selection of appropriate rapid ID and AST of PBC methods in different laboratory settings.
- 29 February 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 85 (2) , 174-176
Prevalence and phylogenetic characterization of human enterovirus D68 among children with respiratory infection in Hong Kong
- 29 February 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 85 (2) , 174-176
Prevalence and phylogenetic characterization of human enterovirus D68 among children with respiratory infection in Hong Kong
- 21 October 2014
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 70 (2) , 441-447
Complementary use of MALDI-TOF MS and real-time PCR-melt curve analysis for rapid identification of methicillin-resistant staphylococci and VRE
To develop a rapid method for routine screening of methicillin-resistant staphylococci and VRE for clinical isolates and positive blood cultures.Our method consisted of two parts: MALDI-TOF MS was used for identification of staphylococci and enterococci, followed by antibiotic resistance detection by real-time PCR-melt curve analysis without DNA extraction. The latter part included a triplex reaction for staphylococcal culture isolates (mecA, mecALGA251 and Panton-Valentine leucocidin genes), dual PCR of mecA/mecALGA251 and nuc genes for staphylococcal blood cultures, and a duplex reaction for enterococci (vanA and vanB genes). A total of 124 clinical isolates and 56 positive blood cultures were tested. MALDI-TOF MS was performed using Microflex LT (Bruker Daltonik, Bremen, Germany) and Rotor-Gene Q (Qiagen, Hilden, Germany) was used for real-time PCR-melt curve analysis. The total assay time was <2.5 h.The results revealed 100% concordance with antibiotic susceptibility testing or other reference methods for all culture isolates and enterococcal blood cultures. The percentage of concordance for staphylococcal blood cultures was 97.5%.The method described herein was fast, economical, reliable and capable of detecting mecALGA251, vanB1 and vanB2 genotypes, which are not included in most commercial assays. Large-scale screening is required to further test the performance of this protocol, especially for genotypes that are infrequently encountered.
- 21 October 2014
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 70 (2) , 441-447
Complementary use of MALDI-TOF MS and real-time PCR-melt curve analysis for rapid identification of methicillin-resistant staphylococci and VRE
To develop a rapid method for routine screening of methicillin-resistant staphylococci and VRE for clinical isolates and positive blood cultures.Our method consisted of two parts: MALDI-TOF MS was used for identification of staphylococci and enterococci, followed by antibiotic resistance detection by real-time PCR-melt curve analysis without DNA extraction. The latter part included a triplex reaction for staphylococcal culture isolates (mecA, mecALGA251 and Panton-Valentine leucocidin genes), dual PCR of mecA/mecALGA251 and nuc genes for staphylococcal blood cultures, and a duplex reaction for enterococci (vanA and vanB genes). A total of 124 clinical isolates and 56 positive blood cultures were tested. MALDI-TOF MS was performed using Microflex LT (Bruker Daltonik, Bremen, Germany) and Rotor-Gene Q (Qiagen, Hilden, Germany) was used for real-time PCR-melt curve analysis. The total assay time was <2.5 h.The results revealed 100% concordance with antibiotic susceptibility testing or other reference methods for all culture isolates and enterococcal blood cultures. The percentage of concordance for staphylococcal blood cultures was 97.5%.The method described herein was fast, economical, reliable and capable of detecting mecALGA251, vanB1 and vanB2 genotypes, which are not included in most commercial assays. Large-scale screening is required to further test the performance of this protocol, especially for genotypes that are infrequently encountered.
- 1 December 2009
- p. 23-6
Comparative host gene transcription by microarray analysis early after infection of the Huh7 cell line by SARS coronavirus and human coronavirus 229E.
During the early stages of infection, SARS-CoV produces more severe perturbation of host cell gene expression in a human epithelial cell line of liver origin than the HCoV-229E.
- 1 December 2009
- p. 23-6
Comparative host gene transcription by microarray analysis early after infection of the Huh7 cell line by SARS coronavirus and human coronavirus 229E.
During the early stages of infection, SARS-CoV produces more severe perturbation of host cell gene expression in a human epithelial cell line of liver origin than the HCoV-229E.