Gaocheng Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gaocheng Yan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cong Yin
School of Electric Power, Civil Engineering and Architecture, Shanxi University, Taiyuan 030006, China
1 shared publication - Huaiping Mu
School of Energy, Power and Mechanical Engineering, North China Electric Power University, Changping District, Beijing 102206, China
1 shared publication - Jiye Zhang
Guangdong University of Science and Technology, Dongguan, Guangdong, China
1 shared publication - Lixing Zheng
School of Electric Power, Civil Engineering and Architecture, Shanxi University, Taiyuan 030006, China
1 shared publication - Qianzi Ma
School of Electric Power, Civil Engineering and Architecture, Shanxi University, Taiyuan 030006, China
1 shared publication - Shi Liu
School of Energy, Power and Mechanical Engineering, North China Electric Power University, Changping District, Beijing 102206, China
1 shared publication
Latest Publications
- Open Access
Cost Sensitivity-Assisted Net Load Forecast Correction for Day-Ahead Scheduling of Wind–Solar–Coal Systems with Molten Salt Storage
Wind–solar–coal systems require flexible generation and storage operation to accommodate renewable variability while meeting regional demand and scheduled electricity exports. Coordinating coal-fired units with molten salt thermal energy storage can improve renewable integration and operating economy. However, day-ahead schedules depend on uncertain net load forecasts, and higher forecast accuracy does not necessarily yield lower operating costs. This paper proposes a cost sensitivity-assisted forecast correction framework to improve the economic value of net load predictions. Analysis of the scheduling model links forecast errors to asymmetric balancing costs, equipment state changes, and inter-temporal storage constraints. Starting from a temporal convolutional network forecast, the framework learns cost responses to signed forecast perturbations evaluated through the complete scheduling model. These responses supervise action value differences in the critics of a soft actor–critic agent, guiding joint correction of hourly forecasts to minimize realized daily cost. Tests on the Reliability Test System–Grid Modernization Laboratory Consortium benchmark show a 7.47% reduction in mean realized cost relative to the uncorrected temporal forecast, despite higher forecast error. With identical cost sensitivity inputs, auxiliary critic supervision reduces mean cost by 2.01% compared with ordinary critic training.
Open AccessCost Sensitivity-Assisted Net Load Forecast Correction for Day-Ahead Scheduling of Wind–Solar–Coal Systems with Molten Salt Storage
Wind–solar–coal systems require flexible generation and storage operation to accommodate renewable variability while meeting regional demand and scheduled electricity exports. Coordinating coal-fired units with molten salt thermal energy storage can improve renewable integration and operating economy. However, day-ahead schedules depend on uncertain net load forecasts, and higher forecast accuracy does not necessarily yield lower operating costs. This paper proposes a cost sensitivity-assisted forecast correction framework to improve the economic value of net load predictions. Analysis of the scheduling model links forecast errors to asymmetric balancing costs, equipment state changes, and inter-temporal storage constraints. Starting from a temporal convolutional network forecast, the framework learns cost responses to signed forecast perturbations evaluated through the complete scheduling model. These responses supervise action value differences in the critics of a soft actor–critic agent, guiding joint correction of hourly forecasts to minimize realized daily cost. Tests on the Reliability Test System–Grid Modernization Laboratory Consortium benchmark show a 7.47% reduction in mean realized cost relative to the uncorrected temporal forecast, despite higher forecast error. With identical cost sensitivity inputs, auxiliary critic supervision reduces mean cost by 2.01% compared with ordinary critic training.
- 22 January 2022
- Published by Springer Nature in Journal of Thermal Science
- Vol. 31 (2) , 571-581
Ignition Characteristics of Lean Coal Used a Novel Alternating-Current Plasma Arc Approach
- 22 January 2022
- Published by Springer Nature in Journal of Thermal Science
- Vol. 31 (2) , 571-581
Ignition Characteristics of Lean Coal Used a Novel Alternating-Current Plasma Arc Approach
- 1 August 2016
- Published by Elsevier in Renewable Energy
- Vol. 93, 525-535
Optimal energy use of the collector tube in solar power tower plant
- 1 August 2016
- Published by Elsevier in Renewable Energy
- Vol. 93, 525-535
Optimal energy use of the collector tube in solar power tower plant