Anko C. Eissens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anko C. Eissens has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Henderik Willem Frijlink
Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, Faculty of Science and Engineering, University of Groningen, 9713 AV Groningen, The Netherlands
4 shared publications - Bahez Gareb
University of Groningen, University Medical Center Groningen
2 shared publications - Jos G. W. Kosterink
Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
2 shared publications - Aisha A. Ahmed
Department of Clinical Pharmacy and Toxicology, Leiden University Medical Center (LUMC), Albinusdreef 2, Leiden 2333 ZA, the Netherlands
1 shared publication - Anneko B. de Waard
Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
1 shared publication - Annemarie Broesder
University of Groningen, Groningen Research Institute of Pharmacy, Department of Pharmaceutical Technology and Biopharmacy, Antonius Deusinglaan 1, 9713 AV Groningen, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 28 April 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (5) , 1354
Capsules with Ileocolonic-Targeted Release of Vitamin B2, B3, and C (ColoVit) Intended for Optimization of Gut Health: Development and Validation of the Production Process
The ileocolonic-targeted delivery of vitamins can establish beneficial alterations in gut microbial composition. Here, we describe the development of capsules containing riboflavin, nicotinic acid, and ascorbic acid covered with a pH-sensitive coating (ColoVit) to establish site-specific release in the ileocolon. Ingredient properties (particle size distribution, morphology) relevant for formulation and product quality were determined. Capsule content and the in vitro release behaviour were determined using a HPLC-method. Uncoated and coated validation batches were produced. Release characteristics were evaluated using a gastro-intestinal simulation system. All capsules met the required specifications. The contents of the ingredients were in the 90.0–120.0% range, and uniformity requirements were met. In the dissolution test a lag-time in drug release of 277–283 min was found, which meets requirements for ileocolonic release. The release itself is immediate as shown by dissolution of the vitamins of more than 75% in 1 h. The production process of the ColoVit formulation was validated and reproducible, it was shown that the vitamin blend was stable during the production process and in the finished coated product. The ColoVit is intended as an innovative treatment approach for beneficial microbiome modulation and optimization of gut health.
- 28 April 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (5) , 1354
Open AccessCapsules with Ileocolonic-Targeted Release of Vitamin B2, B3, and C (ColoVit) Intended for Optimization of Gut Health: Development and Validation of the Production Process
The ileocolonic-targeted delivery of vitamins can establish beneficial alterations in gut microbial composition. Here, we describe the development of capsules containing riboflavin, nicotinic acid, and ascorbic acid covered with a pH-sensitive coating (ColoVit) to establish site-specific release in the ileocolon. Ingredient properties (particle size distribution, morphology) relevant for formulation and product quality were determined. Capsule content and the in vitro release behaviour were determined using a HPLC-method. Uncoated and coated validation batches were produced. Release characteristics were evaluated using a gastro-intestinal simulation system. All capsules met the required specifications. The contents of the ingredients were in the 90.0–120.0% range, and uniformity requirements were met. In the dissolution test a lag-time in drug release of 277–283 min was found, which meets requirements for ileocolonic release. The release itself is immediate as shown by dissolution of the vitamins of more than 75% in 1 h. The production process of the ColoVit formulation was validated and reproducible, it was shown that the vitamin blend was stable during the production process and in the finished coated product. The ColoVit is intended as an innovative treatment approach for beneficial microbiome modulation and optimization of gut health.
- Open Access
- 28 January 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 320
Performance of Tablet Splitters, Crushers, and Grinders in Relation to Personalised Medication with Tablets
Swallowing problems and the required dose adaptations needed to obtain optimal pharmacotherapy may be a hurdle in the use of tablets in daily clinical practice. Tablet splitting, crushing, or grinding is often applied to personalise medication, especially for the elderly and children. In this study, the performance of different types of (commercially available) devices was studied. Included were splitters, screwcap crushers, manual grinders, and electric grinders. Unscored tablets without active ingredient were prepared, with a diameter of 9 and 13 mm and a hardness of 100–220 N. Tablets were split into two parts and the difference in weight was measured. The time needed to pulverise the tablets (crush time) was recorded. The residue remaining in the device (loss) was measured. The powder was sieved to obtain a particle fraction >600 µm and <600 µm. The median particle size and particle size distribution of the later fraction were determined using laser diffraction analysis. Splitting tablets into two equal parts appeared to be difficult with the devices tested. Most screwcap grinders yielded a coarse powder containing larger chunks. Manual and especially electric grinders produced a finer powder, making it suitable for administration via an enteral feeding tube as well as for use in individualised preparations such as capsules. In conclusion, for domestic and incidental use, a screwcap crusher may provide sufficient size reduction, while for the more demanding regular use in hospitals and nursing residences, a manual or electric grinder is preferred.
- 28 January 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 320
Open AccessPerformance of Tablet Splitters, Crushers, and Grinders in Relation to Personalised Medication with Tablets
Swallowing problems and the required dose adaptations needed to obtain optimal pharmacotherapy may be a hurdle in the use of tablets in daily clinical practice. Tablet splitting, crushing, or grinding is often applied to personalise medication, especially for the elderly and children. In this study, the performance of different types of (commercially available) devices was studied. Included were splitters, screwcap crushers, manual grinders, and electric grinders. Unscored tablets without active ingredient were prepared, with a diameter of 9 and 13 mm and a hardness of 100–220 N. Tablets were split into two parts and the difference in weight was measured. The time needed to pulverise the tablets (crush time) was recorded. The residue remaining in the device (loss) was measured. The powder was sieved to obtain a particle fraction >600 µm and <600 µm. The median particle size and particle size distribution of the later fraction were determined using laser diffraction analysis. Splitting tablets into two equal parts appeared to be difficult with the devices tested. Most screwcap grinders yielded a coarse powder containing larger chunks. Manual and especially electric grinders produced a finer powder, making it suitable for administration via an enteral feeding tube as well as for use in individualised preparations such as capsules. In conclusion, for domestic and incidental use, a screwcap crusher may provide sufficient size reduction, while for the more demanding regular use in hospitals and nursing residences, a manual or electric grinder is preferred.
- Open Access
- 23 November 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (12) , 1985
Formulation and In Vitro Evaluation of Pellets Containing Sulfasalazine and Caffeine to Verify Ileo-Colonic Drug Delivery
The ColoPulse coating is a pH-dependent coating that can be used to target drug release to the ileo-colonic region. ColoPulse coated tablets and capsules have demonstrated their targeting capabilities in vivo in more than 100 volunteers and patients. However, so far the ColoPulse coating has not been used for multi-particulate pellet formulations. The sulfasalazine–caffeine method can be used to confirm ileo-colonic drug delivery in vivo. Caffeine serves as a release marker in this method, while sulfasalazine serves as a marker for colonic arrival. In this study, extrusion–spheronization was used to produce microcrystalline cellulose based pellets containing both caffeine and sulfasalazine. Dissolution tests revealed that a superdisintegrant, i.e., croscarmellose sodium or sodium starch glycolate, should be incorporated in the formulation to achieve acceptable release profiles for both sulfasalazine and caffeine. However, acceptable release profiles were only obtained when the pelletizing liquid consisted of ethanol/water 1/1 (v/v) but not with pure water. This phenomenon was ascribed to the differences in the degree of swelling of the superdisintegrant in the pelletizing liquid during the granulation process. The pellets were coated with the ColoPulse coating and showed the desired pH-dependent pulsatile release profile in vitro. In future clinical studies, ileo-colonic targeting should be verified.
- 23 November 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (12) , 1985
Open AccessFormulation and In Vitro Evaluation of Pellets Containing Sulfasalazine and Caffeine to Verify Ileo-Colonic Drug Delivery
The ColoPulse coating is a pH-dependent coating that can be used to target drug release to the ileo-colonic region. ColoPulse coated tablets and capsules have demonstrated their targeting capabilities in vivo in more than 100 volunteers and patients. However, so far the ColoPulse coating has not been used for multi-particulate pellet formulations. The sulfasalazine–caffeine method can be used to confirm ileo-colonic drug delivery in vivo. Caffeine serves as a release marker in this method, while sulfasalazine serves as a marker for colonic arrival. In this study, extrusion–spheronization was used to produce microcrystalline cellulose based pellets containing both caffeine and sulfasalazine. Dissolution tests revealed that a superdisintegrant, i.e., croscarmellose sodium or sodium starch glycolate, should be incorporated in the formulation to achieve acceptable release profiles for both sulfasalazine and caffeine. However, acceptable release profiles were only obtained when the pelletizing liquid consisted of ethanol/water 1/1 (v/v) but not with pure water. This phenomenon was ascribed to the differences in the degree of swelling of the superdisintegrant in the pelletizing liquid during the granulation process. The pellets were coated with the ColoPulse coating and showed the desired pH-dependent pulsatile release profile in vitro. In future clinical studies, ileo-colonic targeting should be verified.