Thomas Fromenteze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Fromenteze has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
David Carsenat
XLIM – CNRS 123, Avenue Albert Thomas, 87060 Limoges Cedex, France
2 shared publicationsDavid R. Smith
Center for Metamaterials and Integrated Plasmonics, Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708, USA
2 shared publicationsJonah Gollub
Center for Metamaterials and Integrated Plasmonics, Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708, USA
2 shared publicationsMichael Boyarsky
Center for Metamaterials and Integrated Plasmonics, Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708, USA
2 shared publicationsXiaojun Liu
Center for Metamaterials and Integrated Plasmonics, Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708, USA
2 shared publicationsCyril Decroze
XLIM – CNRS 123, Avenue Albert Thomas, 87060 Limoges Cedex, France
1 shared publication
Latest Publications
- Open Access
- 15 July 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (15) , 16760-16776
Phaseless computational imaging with a radiating metasurface
Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized pseudo-orthogonal radiation patterns to illuminate an object of interest—notably, frequency-diverse metasurfaces have been exploited as fast and low-cost alternative to conventional coherent imaging systems. However, accurately measuring the complex-valued signals in the frequency domain can be burdensome, particularly for sub-centimeter wavelengths. Here, computational imaging is studied under the relaxed constraint of intensity-only measurements. A novel 3D imaging system is conceived based on ‘phaseless’ and compressed measurements, with benefits from recent advances in the field of phase retrieval. In this paper, the methodology associated with this novel principle is described, studied, and experimentally demonstrated in the microwave range. A comparison of the estimated images from both complex valued and phaseless measurements are presented, verifying the fidelity of phaseless computational imaging.
- 15 July 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (15) , 16760-16776
Open AccessPhaseless computational imaging with a radiating metasurface
Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized pseudo-orthogonal radiation patterns to illuminate an object of interest—notably, frequency-diverse metasurfaces have been exploited as fast and low-cost alternative to conventional coherent imaging systems. However, accurately measuring the complex-valued signals in the frequency domain can be burdensome, particularly for sub-centimeter wavelengths. Here, computational imaging is studied under the relaxed constraint of intensity-only measurements. A novel 3D imaging system is conceived based on ‘phaseless’ and compressed measurements, with benefits from recent advances in the field of phase retrieval. In this paper, the methodology associated with this novel principle is described, studied, and experimentally demonstrated in the microwave range. A comparison of the estimated images from both complex valued and phaseless measurements are presented, verifying the fidelity of phaseless computational imaging.
- Open Access
Phaseless computational imaging with a radiating metasurface
Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized pseudo-orthogonal radiation patterns to illuminate an object of interest---notably, frequency-diverse metasurfaces have been exploited as fast and low-cost alternative to conventional coherent imaging systems. However, accurately measuring the complex-valued signals in the frequency domain can be burdensome, particularly for sub-centimeter wavelengths. Here, computational imaging is studied under the relaxed constraint of intensity-only measurements. A novel 3D imaging system is conceived based on 'phaseless' and compressed measurements, with benefits from recent advances in the field of phase retrieval. In this paper, the methodology associated with this novel principle is described, studied, and experimentally demonstrated in the microwave range. A comparison of the estimated images from both complex valued and phaseless measurements are presented, verifying the fidelity of phaseless computational imaging.
Open AccessPhaseless computational imaging with a radiating metasurface
Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized pseudo-orthogonal radiation patterns to illuminate an object of interest---notably, frequency-diverse metasurfaces have been exploited as fast and low-cost alternative to conventional coherent imaging systems. However, accurately measuring the complex-valued signals in the frequency domain can be burdensome, particularly for sub-centimeter wavelengths. Here, computational imaging is studied under the relaxed constraint of intensity-only measurements. A novel 3D imaging system is conceived based on 'phaseless' and compressed measurements, with benefits from recent advances in the field of phase retrieval. In this paper, the methodology associated with this novel principle is described, studied, and experimentally demonstrated in the microwave range. A comparison of the estimated images from both complex valued and phaseless measurements are presented, verifying the fidelity of phaseless computational imaging.
- 21 March 2016
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 8 (4-5) , 815-823
Passive compression technique applied to UWB beamforming and imaging architectures
Recent works have demonstrated the feasibility of microwave imaging using compressive techniques, exempting the use of active delay lines, phase shifters, or moving parts to achieve beamforming. With this method, waves are coded in a passive way by a compressive device to reduce the complexity of the transmitter and/or receiver chains of the telecommunication and radar systems requiring beamsteering. Such a technique is based on the exploitation of the frequency diversity, implying that a reduction of the compressive device's volume imposes a diminution of the number of driven antennas. In this paper, the improvement brought by simultaneous excitations of the compressive device is presented. Adapting a new mathematical formulation, it is shown that M inputs can send independent waveforms allowing the beamsteering of an N-elements antenna array, while maintaining N > M.
- 21 March 2016
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 8 (4-5) , 815-823
Passive compression technique applied to UWB beamforming and imaging architectures
Recent works have demonstrated the feasibility of microwave imaging using compressive techniques, exempting the use of active delay lines, phase shifters, or moving parts to achieve beamforming. With this method, waves are coded in a passive way by a compressive device to reduce the complexity of the transmitter and/or receiver chains of the telecommunication and radar systems requiring beamsteering. Such a technique is based on the exploitation of the frequency diversity, implying that a reduction of the compressive device's volume imposes a diminution of the number of driven antennas. In this paper, the improvement brought by simultaneous excitations of the compressive device is presented. Adapting a new mathematical formulation, it is shown that M inputs can send independent waveforms allowing the beamsteering of an N-elements antenna array, while maintaining N > M.
- Open Access
- 17 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 4, 1050-1060
Single-Shot Compressive Multiple-Inputs Multiple-Outputs Radar Imaging Using a Two-Port Passive Device
This paper presents a compressive technique that simplifies the architecture of multiple-input multiple-output (MIMO) radar imaging systems. By means of a passive device connected to an MIMO array of antennae, a novel approach is introduced to extract the interaction between antennae from a compressed signal measured between two ports. This technique relies on a multiplexing principle that exploits the frequency diversity and it is thus particularly suitable for ultrawideband imaging systems. This paper presents the theoretical principle underlying this compressive technique, defining the key parameters affecting the information retrieval from a measured frequency signal and the prior characterization of the compressive device's transfer functions. Simulations are performed to demonstrate the potential of the technique for MIMO ultrawideband imaging systems and its compatibility with fast range migration algorithms based on fast Fourier transforms. Finally, an experimental validation is performed with a two-dimensional radiating aperture connected to a compressive device, allowing for the three-dimensional near-field imaging of different targets.
- 17 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 4, 1050-1060
Open AccessSingle-Shot Compressive Multiple-Inputs Multiple-Outputs Radar Imaging Using a Two-Port Passive Device
This paper presents a compressive technique that simplifies the architecture of multiple-input multiple-output (MIMO) radar imaging systems. By means of a passive device connected to an MIMO array of antennae, a novel approach is introduced to extract the interaction between antennae from a compressed signal measured between two ports. This technique relies on a multiplexing principle that exploits the frequency diversity and it is thus particularly suitable for ultrawideband imaging systems. This paper presents the theoretical principle underlying this compressive technique, defining the key parameters affecting the information retrieval from a measured frequency signal and the prior characterization of the compressive device's transfer functions. Simulations are performed to demonstrate the potential of the technique for MIMO ultrawideband imaging systems and its compatibility with fast range migration algorithms based on fast Fourier transforms. Finally, an experimental validation is performed with a two-dimensional radiating aperture connected to a compressive device, allowing for the three-dimensional near-field imaging of different targets.