Gerard F. Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gerard F. Jones has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aaron P. Wemhoff
Department of Mechanical Engineering, Villanova University, 800 Lancaster Avenue, Villanova, PA 19085
3 shared publications - Amy S. Fleischer
College of Engineering, California Polytechnic State University, San Luis Obispo, CA, USA
3 shared publications - Sebastian Araya
Department of Mechanical Engineering, Villanova University, 800 Lancaster Avenue, Villanova, PA 19085
3 shared publications - Finley R. Shapiro
Department of Engineering Leadership and Society, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
2 shared publications - Alfonso Ortega1 shared publication
- Carol Caceres1 shared publication
Latest Publications
- Open Access
- 19 May 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (10) , 6154
A Validated Model, Scalability, and Plant Growth Results for an Agrivoltaic Greenhouse
We developed an agrivoltaic greenhouse (a ‘test cell’) that partially trapped waste heat from two photovoltaic (PV) panels. These panels served as parts of the roof of the enclosure to extend the growing season. Relative humidity, internal air temperature, incident solar radiation, wind speed, and wind direction were measured for one year. A locally 1-D transient heat and moisture transport model, as well as a shadowing model, was developed and validated with experimental data. The models were used to investigate the effects of altering various parameters of the greenhouse in a scalability study. The design kept test cell air temperatures generally above ambient throughout the year, with the test cell temperature below freezing for 36% less of the year than ambient. Plant growth experiments showed that kale, Brassica oleraceae, a shade-tolerant plant, can be grown within the test cell throughout the winter. The simulations showed that enlarging the greenhouse will increase cell air temperatures but that powering an electric load from the PV panels will reduce cell air temperatures.
- 19 May 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (10) , 6154
Open AccessA Validated Model, Scalability, and Plant Growth Results for an Agrivoltaic Greenhouse
We developed an agrivoltaic greenhouse (a ‘test cell’) that partially trapped waste heat from two photovoltaic (PV) panels. These panels served as parts of the roof of the enclosure to extend the growing season. Relative humidity, internal air temperature, incident solar radiation, wind speed, and wind direction were measured for one year. A locally 1-D transient heat and moisture transport model, as well as a shadowing model, was developed and validated with experimental data. The models were used to investigate the effects of altering various parameters of the greenhouse in a scalability study. The design kept test cell air temperatures generally above ambient throughout the year, with the test cell temperature below freezing for 36% less of the year than ambient. Plant growth experiments showed that kale, Brassica oleraceae, a shade-tolerant plant, can be grown within the test cell throughout the winter. The simulations showed that enlarging the greenhouse will increase cell air temperatures but that powering an electric load from the PV panels will reduce cell air temperatures.
- 6 April 2022
- Published by Elsevier in Solar Energy
- Vol. 237, 135-143
Reconsidering beam and diffuse solar fractions for agrivoltaics
- 6 April 2022
- Published by Elsevier in Solar Energy
- Vol. 237, 135-143
Reconsidering beam and diffuse solar fractions for agrivoltaics
- Open Access
- 16 July 2021
- Published by ASME International
Thermo-Economic Assessment of Recovering Waste Heat From Data Centers Through an Organic Rankine Cycle
- 16 July 2021
- Published by ASME International
Open AccessThermo-Economic Assessment of Recovering Waste Heat From Data Centers Through an Organic Rankine Cycle
- Open Access
- 16 July 2021
- Published by ASME International
Thermo-Economic Assessment of Recovering Waste Heat From Data Centers Through an Organic Rankine Cycle
Reusing the waste heat from data centers has undoubtedly generated interest for reducing a data center’s total electricity consumption. A thermo-economic model is presented to analyze the economic benefits of applying an organic Rankine cycle (ORC) as a waste heat recovery system applied in data centers. A simplified steady-state model was developed that captures the multiple
- 16 July 2021
- Published by ASME International
Open AccessThermo-Economic Assessment of Recovering Waste Heat From Data Centers Through an Organic Rankine Cycle
Reusing the waste heat from data centers has undoubtedly generated interest for reducing a data center’s total electricity consumption. A thermo-economic model is presented to analyze the economic benefits of applying an organic Rankine cycle (ORC) as a waste heat recovery system applied in data centers. A simplified steady-state model was developed that captures the multiple
- 7 August 2020
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (2)
Study of a Lab-Scale Organic Rankine Cycle for the Ultra-Low-Temperature Waste Heat Recovery Associated With Data Centers
The ongoing growth in data center rack power density leads to an increased capability for waste heat recovery. Recent studies revealed the organic Rankine cycle (ORC) as a viable means for data center waste heat recovery since the ORC uses waste heat to generate on-site, low-cost electricity, which can produce economic benefits by reducing the overall data center power consumption. This paper describes the first experimental and theoretical study of a lab-scale ORC designed for ultralow grade (40–85 °C) waste heat conditions typical of a data center server rack, and it outlines the implementation of a similar ORC system for a data center. The experimental results show thermal efficiencies ranging from 1.9% at 43 °C to 4.6% at 81 °C. The largest contributors to ORC exergy destruction are the evaporator and condenser due to large fluid temperature differences in the heat exchangers. The average isentropic efficiency of the expander is 70%. A second-law analysis estimates a reduction of 4–8% in data center power requirements when ORC power is fed back into the servers at a waste heat temperature of 90 °C. The data from the lab-scale experiment, when complemented by the thermodynamic model, provide the necessary first step toward advancing this type of waste heat recovery for data centers (DCs).
- 7 August 2020
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (2)
Study of a Lab-Scale Organic Rankine Cycle for the Ultra-Low-Temperature Waste Heat Recovery Associated With Data Centers
The ongoing growth in data center rack power density leads to an increased capability for waste heat recovery. Recent studies revealed the organic Rankine cycle (ORC) as a viable means for data center waste heat recovery since the ORC uses waste heat to generate on-site, low-cost electricity, which can produce economic benefits by reducing the overall data center power consumption. This paper describes the first experimental and theoretical study of a lab-scale ORC designed for ultralow grade (40–85 °C) waste heat conditions typical of a data center server rack, and it outlines the implementation of a similar ORC system for a data center. The experimental results show thermal efficiencies ranging from 1.9% at 43 °C to 4.6% at 81 °C. The largest contributors to ORC exergy destruction are the evaporator and condenser due to large fluid temperature differences in the heat exchangers. The average isentropic efficiency of the expander is 70%. A second-law analysis estimates a reduction of 4–8% in data center power requirements when ORC power is fed back into the servers at a waste heat temperature of 90 °C. The data from the lab-scale experiment, when complemented by the thermodynamic model, provide the necessary first step toward advancing this type of waste heat recovery for data centers (DCs).
- 26 April 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 138 (8) , 082802
Optimizing a Functionally Graded Metal-Matrix Heat Sink Through Growth of a Constructal Tree of Convective Fins
Optimal material utilization in metal-matrix heat sink is investigated using constructal design (CD) in combination with fin theory to develop a constructal tree of optimally shaped convective fins. The structure is developed through systematic growth of constructs, consisting initially of a single convective fin enveloped in a convective medium. Increasingly complex convective fin structures are created and optimized at each level of complexity to determine optimal fin shapes, aspect ratios, and fin-base thickness ratios. One result of the optimized structures is a functional grading of porosity. The porosity increases as a function of distance from the heated surface in a manner ranging from linear to a power function of distance with exponent of about 2. The degree of nonlinearity in this distribution varies depending on the volume of the heat sink and average packing density and approaches a parabolic shape for large volume. For small volume, porosity approaches a linear function of distance. Thus, a parabolic (or least-material) fin shape at each construct level would not necessarily be optimal. Significant improvements in total heat transfer, up to 55% for the cases considered in this work, were observed when the fin shape is part of the optimization in a constructal tree of convective fins. The results of this work will lead to better understanding of the role played by the porosity distribution in a metal-matrix heat sink and may be applied to the analysis, optimization, and design of more effective heat sinks for electronics cooling and related areas.
- 26 April 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 138 (8) , 082802
Optimizing a Functionally Graded Metal-Matrix Heat Sink Through Growth of a Constructal Tree of Convective Fins
Optimal material utilization in metal-matrix heat sink is investigated using constructal design (CD) in combination with fin theory to develop a constructal tree of optimally shaped convective fins. The structure is developed through systematic growth of constructs, consisting initially of a single convective fin enveloped in a convective medium. Increasingly complex convective fin structures are created and optimized at each level of complexity to determine optimal fin shapes, aspect ratios, and fin-base thickness ratios. One result of the optimized structures is a functional grading of porosity. The porosity increases as a function of distance from the heated surface in a manner ranging from linear to a power function of distance with exponent of about 2. The degree of nonlinearity in this distribution varies depending on the volume of the heat sink and average packing density and approaches a parabolic shape for large volume. For small volume, porosity approaches a linear function of distance. Thus, a parabolic (or least-material) fin shape at each construct level would not necessarily be optimal. Significant improvements in total heat transfer, up to 55% for the cases considered in this work, were observed when the fin shape is part of the optimization in a constructal tree of convective fins. The results of this work will lead to better understanding of the role played by the porosity distribution in a metal-matrix heat sink and may be applied to the analysis, optimization, and design of more effective heat sinks for electronics cooling and related areas.