Antoniu-Oreste Gostian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antoniu-Oreste Gostian has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- David Schwarz
Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Cologne, Germany
5 shared publications David Pazen
3 shared publicationsDirk Beutner
3 shared publicationsAndreas Anagiotos
Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne
2 shared publications- Andreas Anagiotos
Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University of Cologne, Cologne, Germany
2 shared publications - Dirk Beutner
Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Cologne, Germany
2 shared publications
Latest Publications
- 1 August 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (7) , e197-e202
Long-term Follow-up Study of the Sandwich Cartilage Shoe Technique in Cases of Insecure Stapes Footplate
Analysis of the audiometric results after repair of a defective footplate with the sandwich cartilage shoe technique in a follow-up study.Retrospective analysis of audiometric data.Hospital.The cohort consisted of 12 patients, who underwent ossicular reconstruction after sandwich cartilage shoe technique in a case of insecure stapes footplate. The mean age was 42.7 years with an equal sex distribution. In every patient, cholesteatoma was the reason for surgery with 75% being revision cases.Sandwich cartilage shoe technique in case of insecure stapes footplate at the department of otorhinolaryngology, head and neck surgery at the University of Cologne over an 8-year period (2007-2015).The use of the "sandwich cartilage shoe technique" in case of a broken or unstable footplate allows a safe occlusion of the open vestibule.The statistical analysis revealed a significant improvement of the pure-tone average (p = 0.011) and air-bone gap (ABG) (p = 0.016) after total ossicular replacement prosthesis (TORP) implantation. The hearing was stable at 9 months of follow up.The sandwich cartilage shoe technique offers a safe and effective option as a two-stage procedure in treating patients with fractures of the stapes footplate in case of chronic otitis media. In view of the possible risk of deafness going along with a destruction of an inner ear window, our results can be considered substantial as all our patients will at least be able to regain "social hearing" as they all either achieved a hearing threshold is less than 30 dB or can be sufficiently supplied with a conventional hearing aid.
- 1 August 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (7) , e197-e202
Long-term Follow-up Study of the Sandwich Cartilage Shoe Technique in Cases of Insecure Stapes Footplate
Analysis of the audiometric results after repair of a defective footplate with the sandwich cartilage shoe technique in a follow-up study.Retrospective analysis of audiometric data.Hospital.The cohort consisted of 12 patients, who underwent ossicular reconstruction after sandwich cartilage shoe technique in a case of insecure stapes footplate. The mean age was 42.7 years with an equal sex distribution. In every patient, cholesteatoma was the reason for surgery with 75% being revision cases.Sandwich cartilage shoe technique in case of insecure stapes footplate at the department of otorhinolaryngology, head and neck surgery at the University of Cologne over an 8-year period (2007-2015).The use of the "sandwich cartilage shoe technique" in case of a broken or unstable footplate allows a safe occlusion of the open vestibule.The statistical analysis revealed a significant improvement of the pure-tone average (p = 0.011) and air-bone gap (ABG) (p = 0.016) after total ossicular replacement prosthesis (TORP) implantation. The hearing was stable at 9 months of follow up.The sandwich cartilage shoe technique offers a safe and effective option as a two-stage procedure in treating patients with fractures of the stapes footplate in case of chronic otitis media. In view of the possible risk of deafness going along with a destruction of an inner ear window, our results can be considered substantial as all our patients will at least be able to regain "social hearing" as they all either achieved a hearing threshold is less than 30 dB or can be sufficiently supplied with a conventional hearing aid.
- 1 July 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (6) , 692-697
Acoustic Properties of Collagenous Matrices of Xenogenic Origin for Tympanic Membrane Reconstruction
The acoustic properties of scaffolds made from decellularized extracellular cartilage matrices of porcine origin are comparable to those of the human tympanic membrane.Currently, the reconstruction of tympanic membrane in the context of chronic tympanic membrane defects is mostly performed using autologous fascia or cartilage. Autologous tissue may be associated with lack of graft material in revision patients and requires more invasive and longer operative time. Therefore, other materials are investigated for reconstruction. An increasingly important role could be played by scaffolds from different materials, which are known to induce constructive tissue remodeling.To analyze the acoustic properties, the vibrations of the scaffolds, cartilage, perichondrium and tympanic membrane were measured by laser scanning doppler vibrometry under different static pressures.The analysis of volume velocities serves as an indicator for sound transmission. The results of the average volume velocities at atmospheric pressure show a similar frequency response of the tympanic membrane and the scaffolds with a peak at about 800 Hz. After changing the artificial ear-canal pressure from atmospheric pressure to negative pressure (-100, -200, and -300 daPa) the vibration characteristics of the different membranes remain fairly constant, whereas the results of the perichondrium show a decrease after changing the pressure into the negative range in the frequencies 1 to 3 kHz.The present study showed that the vibration characteristics of the scaffolds under atmospheric and negative pressure can be interpreted as similar to those of thin cartilage (<0.5 mm) and human tympanic membranes. However, in relation to the behavior of these scaffolds made from decellularized extracellular cartilage matrices in vivo, further investigations should be carried out.
- 1 July 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (6) , 692-697
Acoustic Properties of Collagenous Matrices of Xenogenic Origin for Tympanic Membrane Reconstruction
The acoustic properties of scaffolds made from decellularized extracellular cartilage matrices of porcine origin are comparable to those of the human tympanic membrane.Currently, the reconstruction of tympanic membrane in the context of chronic tympanic membrane defects is mostly performed using autologous fascia or cartilage. Autologous tissue may be associated with lack of graft material in revision patients and requires more invasive and longer operative time. Therefore, other materials are investigated for reconstruction. An increasingly important role could be played by scaffolds from different materials, which are known to induce constructive tissue remodeling.To analyze the acoustic properties, the vibrations of the scaffolds, cartilage, perichondrium and tympanic membrane were measured by laser scanning doppler vibrometry under different static pressures.The analysis of volume velocities serves as an indicator for sound transmission. The results of the average volume velocities at atmospheric pressure show a similar frequency response of the tympanic membrane and the scaffolds with a peak at about 800 Hz. After changing the artificial ear-canal pressure from atmospheric pressure to negative pressure (-100, -200, and -300 daPa) the vibration characteristics of the different membranes remain fairly constant, whereas the results of the perichondrium show a decrease after changing the pressure into the negative range in the frequencies 1 to 3 kHz.The present study showed that the vibration characteristics of the scaffolds under atmospheric and negative pressure can be interpreted as similar to those of thin cartilage (<0.5 mm) and human tympanic membranes. However, in relation to the behavior of these scaffolds made from decellularized extracellular cartilage matrices in vivo, further investigations should be carried out.
- 1 June 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (5) , 524-532
Loads and Coupling Modalities Influence the Performance of the Floating Mass Transducer as a Round Window Driver
Hypothesis: High loads forcing the floating mass transducer (FMT) of a single active middle ear implant toward the round window membrane (RWM) affect the backward stimulation of the cochlea. Background: Various factors influence the backward stimulation of the cochlea. We investigated the effects of various loads applied to the FMT together with different coupling techniques at the fully exposed RWM on the vibration transmission. Methods: Experimental study on temporal bones with the FMT linked to a load cell mounted on a translation stage moving it against the fully exposed RWM with increasing loads up to 200 mN by itself, with interposed perichondrium, cartilage or connected to the round window coupler. Cochlear stimulation is measured by the volume velocities of the stapes footplate using LASER-Doppler-vibrometry. Results: Loads ranging from 5 to 20 mN induce the highest volume velocities of the stapes footplate. Increasing loads decrease the transmission of vibration in the low-frequency range but enhance the transmission of high frequencies. The interposition of perichondrium and cartilage proved to be advantageous. Conclusion: The load applied to the FMT distinctly affects the backward stimulation of the cochlea. Although increasing loads have inverse effects on the transmission of low and high frequencies, high loads lead to an overall decrease of cochlear stimulation. Out of the applied coupling techniques interposed perichondrium and cartilage allow for the most efficient stimulation.
- 1 June 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (5) , 524-532
Loads and Coupling Modalities Influence the Performance of the Floating Mass Transducer as a Round Window Driver
Hypothesis: High loads forcing the floating mass transducer (FMT) of a single active middle ear implant toward the round window membrane (RWM) affect the backward stimulation of the cochlea. Background: Various factors influence the backward stimulation of the cochlea. We investigated the effects of various loads applied to the FMT together with different coupling techniques at the fully exposed RWM on the vibration transmission. Methods: Experimental study on temporal bones with the FMT linked to a load cell mounted on a translation stage moving it against the fully exposed RWM with increasing loads up to 200 mN by itself, with interposed perichondrium, cartilage or connected to the round window coupler. Cochlear stimulation is measured by the volume velocities of the stapes footplate using LASER-Doppler-vibrometry. Results: Loads ranging from 5 to 20 mN induce the highest volume velocities of the stapes footplate. Increasing loads decrease the transmission of vibration in the low-frequency range but enhance the transmission of high frequencies. The interposition of perichondrium and cartilage proved to be advantageous. Conclusion: The load applied to the FMT distinctly affects the backward stimulation of the cochlea. Although increasing loads have inverse effects on the transmission of low and high frequencies, high loads lead to an overall decrease of cochlear stimulation. Out of the applied coupling techniques interposed perichondrium and cartilage allow for the most efficient stimulation.
- 1 April 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (4) , 339-344
Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing
The underwater technique offers a reliable nontraumatic method for electrode array insertions during cochlear implantation. The method respects the physiology of the cochlea und minimizes the pressure variations during cochlear opening and implantation.
- 1 April 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (4) , 339-344
Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing
The underwater technique offers a reliable nontraumatic method for electrode array insertions during cochlear implantation. The method respects the physiology of the cochlea und minimizes the pressure variations during cochlear opening and implantation.
- 28 March 2016
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (11) , 3651-3661
Performance of the round window soft coupler for the backward stimulation of the cochlea in a temporal bone model
The round window vibroplasty is a feasible option for the treatment of conductive, sensorineural and mixed hearing loss. Although clinical data suggest a satisfying clinical outcome with various coupling methods, the most efficient coupling technique of the floating mass transducer to the round window is still a matter of debate. For this, a soft silicone-made coupler has been developed recently that aims to ease and optimize the stimulation of the round window membrane of this middle ear implant. We performed a temporal bone study evaluating the performance of the soft coupler compared to the coupling with individually shaped cartilage, perichondrium and the titanium round window coupler with loads up to 20 mN at the unaltered and fully exposed round window niche. The stimulation of the cochlea was measured by the volume velocities of the stapes footplate detected by a laser Doppler vibrometer. The coupling method was computed as significant factor with cartilage and perichondrium allowing for the highest volume velocities followed by the soft and titanium coupler. Exposure of the round window niche allowed for higher volume velocities while the applied load did not significantly affect the results. The soft coupler allows for a good contact to the round window membrane and an effective backward stimulation of the cochlea. Clinical data are mandatory to evaluate performance of this novel coupling method in vivo.
- 28 March 2016
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (11) , 3651-3661
Performance of the round window soft coupler for the backward stimulation of the cochlea in a temporal bone model
The round window vibroplasty is a feasible option for the treatment of conductive, sensorineural and mixed hearing loss. Although clinical data suggest a satisfying clinical outcome with various coupling methods, the most efficient coupling technique of the floating mass transducer to the round window is still a matter of debate. For this, a soft silicone-made coupler has been developed recently that aims to ease and optimize the stimulation of the round window membrane of this middle ear implant. We performed a temporal bone study evaluating the performance of the soft coupler compared to the coupling with individually shaped cartilage, perichondrium and the titanium round window coupler with loads up to 20 mN at the unaltered and fully exposed round window niche. The stimulation of the cochlea was measured by the volume velocities of the stapes footplate detected by a laser Doppler vibrometer. The coupling method was computed as significant factor with cartilage and perichondrium allowing for the highest volume velocities followed by the soft and titanium coupler. Exposure of the round window niche allowed for higher volume velocities while the applied load did not significantly affect the results. The soft coupler allows for a good contact to the round window membrane and an effective backward stimulation of the cochlea. Clinical data are mandatory to evaluate performance of this novel coupling method in vivo.