NYNihal Yücel

Nihal Yücel

*This is an algorithmically generated author record based on publicly available information.

Nihal Yücel has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Age, gender and season dependent 25(OH)D levels in children and adults living in Istanbul

    by Zeynep Yildiz, Özlem Hürmeydan, Özlem Çakır Madenci, Asuman Orçun, Nihal Yücel

    Background: We evaluated population characteristics of serum 25-hydroxyvitamin D (25(OH)D) levels and determined the influence of age, gender and season in an extensive dataset. Materials and methods: Laboratory results of 103,509 adults and 19,186 children were retrospectively evaluated. Study group was classified regarding ages as; 60 years for adults and 0–1, 1–12 months,1–3, 4–6, 7–9, 10–12, 13–15 and 16–18 years for children. Seasonal values were also determined. Levels were measured by Architect i1000 SR (Abbott Diagnostics, USA). Results: The median (2.5–97.5 percentiles) of 25(OH)D levels were 38.75 (9.5–158.25) nmol/L for adults and 43.25 (11.25–125.5) nmol/L for children. There were significant gender differences for both adults and children. Values differed significantly among age subgroups (p’s < 0.01). A total of 63% of adults and 59.5% of children had 25(OH)D levels below 50 nmol/L (p < 0.001). 25(OH)D levels were significantly lower in the winter compared with summer (p’s < 0.001). Even levels in summer were moderate deficient for all group. Conclusion: The rate of 25(OH)D deficiency was remarkable during the whole year. This will provide large-scale data about 25(OH)D status in Turkish people and may contribute to the prevention and treatment of this condition for better healthcare outcomes.


  • Alkaline phosphatase ınterference in an unconjugated estriol assay causing a false positive Down syndrome screening result

    by Zeynep Yildiz, Özlem Çakır Madenci, Asuman Orçun, Özlem Hürmeydan, Lale Köroğlu Dağdelen, Nihal Yücel

    Objective: Decreased unconjugated estriol (uE3) concentrations increase calculated risk of Down syndrome. Therefore, falsely low uE3, due to assay interference, have the potential to cause false-positive screening results. Here we present a 35 years old woman with a pregnancy of 17+2 weeks. Materials and methods: Second-trimester screening test was performed on the UniCelDxI 800 (Beckman Coulter, Brea, CA, USA) analyzer and her uE3 level was 0.21 ng/mL (0.21 MoM). Risk calculated for DS was 1/8. Measurements were repeated on IMMULITE 2000 XPi (Siemens Healthcare Diagnostics Inc., USA). uE3 result was 0.614 ng/mL (0.97 MoM). The risk for DS was negative with this system. There was no sign of fetal anomaly on three-dimensional ultrasound examination and cell-free fetal DNA screening test. We suspected assay interference for uE3. Results: Serial dilutions of serum samples revealed nonlinearity. 36.3% increase was observed with heterophile antibody blocking tubes. The post-polyethylene glycol treatment resulted approximately the same uE3 levels as IMMULITE system. Addition of alkaline phosphatase Scavenger to serum increased the result by 90% showing that falsely low E3 result was due to an interferent reacting on assay medium. Conclusion: Laboratories should be aware that falsely low uE3 results due to interference may be obtained.


  • Open Access

    Czy galektyna-3 ma związek z nerkowym wydalaniem albumin w cukrzycy typu 2?

    by Nihal Yücel, Özlem Çakır Madenci, Aycan Bölük, Lale Köroğlu Dağdelen, Yusuf Temel, Mehmet Sargın, Asuman Orçun

    The relationship between galectin-3 and diabetes mellitus or renal function has recently been investigated. In this study, we tried to evaluate the association of galectin-3 in urinary albumin excretion levels in type 2 diabetic patients. In a group of 137 type 2 diabetes patients, the mean of the last three urinary microalbumin/creatinine ratios and galectin-3 levels were evaluated. The patient group was divided into three subgroups according to their level of albuminuria calculated with urine microalbumin/creatinine ratio. There was no significant difference between the galectin values of the three subgroups. Significant differences were observed between GFR results of group 1 vs. 3 (p < 0.0001) and group 2 vs. 3 (p = 0.0006), and serum creatinine results of group 1 vs. 3 (p = 0.0003) and group 2 vs. 3 (p < 0.0001). The three subgroups did not reveal any significant difference concerning the age, BMI, duration of DM, FPG, and HbA1c levels. We concluded that serum galectin-3 values are not affected by the levels of urinary albumin excretion in DM patients. We could not find any relation between galectin-3 and the parameters of DM such as FPG, HbA1c, and duration of the disease. (Endokrynol Pol 2016; 67 (6): 580-584).


  • A paraprotein interference and its management in clinical laboratory / Bir paraprotein interferansı vakasının klinik laboratuvarda yönetimi

    by Özlem Çakır Madenci, Nihal Yücel, Lale Köroğlu Dağdelen, Yusuf Temel, Aycan Bölük, Asuman Orçun Kaptanağası

    In the present study we describe a patient who has interference due to paraproteinemia in her labaratory results. In a patient with a total protein concentration of 10.8 g/dL, a direct bilirubin result higher than total was detected. She also had discordant results in her whole blood count parameters. Further investigation was performed on this patient. Presence of any cold agglutinin and cryoglobulin was tested and excluded first. After 2-mercaptoethanol (2-ME) treatment, patient was idendified as Ig-M Kappa monoclonal gammapathy on immunofixation electrophoresis (IFE). Direct bilirubin interference disappeared after removal of the paraprotein by polyethylene glycol (PEG) precipitation. Laboratory specialist should know paraprotein interference and be able to manage it.


    • 1 January 2015
      • Vol. 61  (12) , 1947-52

    A Comparison of Three Widely Used Immunoassay Systems in Cortisol Measurement.

    by Nihal Yücel, Özlem Çakir Madenci, Aycan Bölük, Lale Köroğlu, Yusuf Temel, Asuman Orçun

    Interassay variability is one of the challenging issues of routine clinical laboratory practice. Commercial plasma cortisol immunoassays are also subject to this issue. In this study, we intended to evaluate the interchangeability of cortisol results of three widely used immunoassay systems. The cortisol values of 150 serum samples measured by three immunoassay systems, Beckman Coulter DXI 800, Roche Modular E170, and Siemens Immulite 2500, were compared. A degree of proportional biases was observed between all three methods; DXI 800 showed the worst biases with the other two systems (slope values 0.67 and 0.77 with E170 and Immulite 2500, respectively). DXI 800 showed poor agreement with other methods (CCC: 0.83 and 0.87, respectively). There was a moderate agreement between E170 and Immulite 2500 (CCC: 0.92). All three methods showed a degree of variability among themselves. DXI 800 results were not interchangeable with the other two systems.


  • Changes of Thyroid Function Tests in Pregnancy and Contribution of Trimester Specific Reference Ranges to Diagnosis

    by Özlem Çakir Madenci̇, Nihal Yücel, Lale Köroğlu Dağdelen, Gülşen Mutluoğlu, Hasan Emin Kaya, Asuman Orçun


  • Open Access

    A Case of Hemoglobin Beckman; An example of Hemoglobin Variants Interfering with HbA1c Measurement

    by Nihal Yucel, Ozlem Cakir Madenci, Lale Dagdelen, Derya Aksoy, Asuman Orcun Kaptanagasi


  • Open Access

    The Relationship Between Glycemic Control And Asymmetrical Dimethylarginine Levels

    by Ozlem Cakir Madenci, Nihal Yucel, Zeynep Arikan, Mehmet Sargin, Derya Akbaba, Osman Kaya, Asuman Orcun Kaptanagasi