John F. Rudan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
John F. Rudan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Randy E. Ellis
School of Computing, Queen’s University, Kingston, ON K7L 2N8, Canada
3 shared publications Andrew W L Dickinson
2 shared publications- Brian J. Rasquinha
School of Computing, Department of Mechanical and Materials Engineering, Queen's University, Kingston, K7L 3N6, Canada.
2 shared publications - Kevin J. Deluzio
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada
2 shared publications - Mohamed S. Hefny
Queen’s University
2 shared publications Randy E Ellis
School of Computing, Queen's University, Kingston, Ontario, Canada
2 shared publications
Latest Publications
- 1 June 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 58, 37-44
How symmetric are metal-on-metal hip resurfacing patients during gait? Insights for the rehabilitation
- 1 June 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 58, 37-44
How symmetric are metal-on-metal hip resurfacing patients during gait? Insights for the rehabilitation
- 1 January 2017
- Published by Elsevier in Gait & Posture
- Vol. 51, 153-158
Correcting waveform bias using principal component analysis: Applications in multicentre motion analysis studies
- 1 January 2017
- Published by Elsevier in Gait & Posture
- Vol. 51, 153-158
Correcting waveform bias using principal component analysis: Applications in multicentre motion analysis studies
- 1 January 2016
- Vol. 220, 98-102
Personalized Guides for Registration in Surgical Navigation.
Personalized guides are increasingly used in orthopedic procedures but do not provide for intraoperative re-planning. This work presents a tracked guide that used physical registration to provide an anatomy-to-tracking coordinate frame transformation for surgical navigation. In a study using seven femoral models derived from clinical CT scans used for hip resurfacing, a guide characterization FRE of 0.4°±0.2°, drill-path drill-path angular TRE of 0.9°±0.4° and a positional TRE of 1.2mm±0.4mm were found; these values are comparable to conventional optical tracking accuracy. This novel use of a tracked guide may be particularly applicable to procedures that require a small surgical exposure, or when operating on anatomical regions with small bones that are difficult to track or reliably register.
- 1 January 2016
- Vol. 220, 98-102
Personalized Guides for Registration in Surgical Navigation.
Personalized guides are increasingly used in orthopedic procedures but do not provide for intraoperative re-planning. This work presents a tracked guide that used physical registration to provide an anatomy-to-tracking coordinate frame transformation for surgical navigation. In a study using seven femoral models derived from clinical CT scans used for hip resurfacing, a guide characterization FRE of 0.4°±0.2°, drill-path drill-path angular TRE of 0.9°±0.4° and a positional TRE of 1.2mm±0.4mm were found; these values are comparable to conventional optical tracking accuracy. This novel use of a tracked guide may be particularly applicable to procedures that require a small surgical exposure, or when operating on anatomical regions with small bones that are difficult to track or reliably register.
- 1 January 2016
- Vol. 220, 301-7
A Toroidal Probe for Measuring Surgically Exposed Joint Centers.
Maintaining the hip center can improve the success of a total hip arthroplasty. A novel probe design, based on mating a toroid with a sphere, was used for kinematic measurements of the femoral head center and implant center in a pre-clinical study of hip joints. In an electromagnetically tracked implementation tested in a laboratory environment, the device measured a spherical center to within 1.2±0.2 mm in a technical validation. Applied to a plastic model of a cadaveric femur, the center of the femoral head was measured to 1.8±0.4 mm and the implant was measured to within 1.5±0.5 mm. Because leg length changes and offset changes in conventional hip arthroplasty can be as much as 16 mm, this device has relatively high accuracy that may improve implant localization for the hip.
- 1 January 2016
- Vol. 220, 301-7
A Toroidal Probe for Measuring Surgically Exposed Joint Centers.
Maintaining the hip center can improve the success of a total hip arthroplasty. A novel probe design, based on mating a toroid with a sphere, was used for kinematic measurements of the femoral head center and implant center in a pre-clinical study of hip joints. In an electromagnetically tracked implementation tested in a laboratory environment, the device measured a spherical center to within 1.2±0.2 mm in a technical validation. Applied to a plastic model of a cadaveric femur, the center of the femoral head was measured to 1.8±0.4 mm and the implant was measured to within 1.5±0.5 mm. Because leg length changes and offset changes in conventional hip arthroplasty can be as much as 16 mm, this device has relatively high accuracy that may improve implant localization for the hip.
- 1 May 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (6) , 707-715
Computer-assisted hip resurfacing planning using Lie group shape models
Introduction Hip resurfacing is a surgical option for osteoarthritis young and active patients. Early failures has been reported due to improper implant placement. Computer-assisted surgery is a promising avenue for more successful procedures. Purpose This paper presents a novel automatic surgical planning for computer-assisted hip resurfacing procedures. The plan defined the femoral head axis that was used to place the implant. The automatic planning was based on a Lie group statistical shape model. Methods A statistical shape model was constructed using 50 femurs from osteoarthritis patients who underwent computer-assisted hip resurfacing. The model was constructed using product Lie groups representation of shapes and nonlinear analysis on the manifold of shapes. A surgical plan was drawn for the derived base shape. The base shape was transformed to 14 femurs with known manual plans. The transformed base plan was used as the computed plan for each femur. Both actual and computed plans were compared. Results The method showed a success by computing plans that differ from the actual plans within the surgical admissible ranges. The minimum crossing distance between the two plans had a mean of 0.75 mm with a standard deviation of 0.54 mm. The angular difference between the two plans had the mean of 5.94\(^{\circ }\) with a standard deviation of 2.14\(^{\circ }\). Conclusion Product Lie groups shape models were proved to be successful in automatic planning for hip resurfacing computer-assisted surgeries. The method can be extended to other orthopedic and general surgeries.- 1 May 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (6) , 707-715
Computer-assisted hip resurfacing planning using Lie group shape models
Introduction Hip resurfacing is a surgical option for osteoarthritis young and active patients. Early failures has been reported due to improper implant placement. Computer-assisted surgery is a promising avenue for more successful procedures. Purpose This paper presents a novel automatic surgical planning for computer-assisted hip resurfacing procedures. The plan defined the femoral head axis that was used to place the implant. The automatic planning was based on a Lie group statistical shape model. Methods A statistical shape model was constructed using 50 femurs from osteoarthritis patients who underwent computer-assisted hip resurfacing. The model was constructed using product Lie groups representation of shapes and nonlinear analysis on the manifold of shapes. A surgical plan was drawn for the derived base shape. The base shape was transformed to 14 femurs with known manual plans. The transformed base plan was used as the computed plan for each femur. Both actual and computed plans were compared. Results The method showed a success by computing plans that differ from the actual plans within the surgical admissible ranges. The minimum crossing distance between the two plans had a mean of 0.75 mm with a standard deviation of 0.54 mm. The angular difference between the two plans had the mean of 5.94\(^{\circ }\) with a standard deviation of 2.14\(^{\circ }\). Conclusion Product Lie groups shape models were proved to be successful in automatic planning for hip resurfacing computer-assisted surgeries. The method can be extended to other orthopedic and general surgeries.- 1 January 2014
- Vol. 196, 163-9
A matrix lie group approach to statistical shape analysis of bones.
Statistical shape models using a principal-component analysis are inadequate for studying shapes that are in non-linear manifolds. Principal tangent components use a matrix Lie group that maps a non-linear manifold to a corresponding linear tangent space. Computations that are performed on the tangent space of the manifold use linear statistics to analyze non-linear shape spaces. The method was tested on bone surface from proximal femurs. Using only three components, the new model recovered 94% of the medical dataset, whereas a conventional method that used linear principal components needed 24 components to achieve the same reconstruction accuracy.
- 1 January 2014
- Vol. 196, 163-9
A matrix lie group approach to statistical shape analysis of bones.
Statistical shape models using a principal-component analysis are inadequate for studying shapes that are in non-linear manifolds. Principal tangent components use a matrix Lie group that maps a non-linear manifold to a corresponding linear tangent space. Computations that are performed on the tangent space of the manifold use linear statistics to analyze non-linear shape spaces. The method was tested on bone surface from proximal femurs. Using only three components, the new model recovered 94% of the medical dataset, whereas a conventional method that used linear principal components needed 24 components to achieve the same reconstruction accuracy.
- 1 January 2011
- Vol. 163, 18-24
On the use of laser scans to validate reverse engineering of bony anatomy.
There is a growing body of evidence to suggest the arthritic hip is an irregularly-shaped, aspherical joint, especially in severely pathological cases. Current methods used to study the shape and motion of the hip in-vivo, are invasive and impractical. This study aimed to assess whether a plastic model of the hip joint can be accurately made from a pelvic CT scan. A cadaver hemi-pelvis was CT imaged and segmented from which a 3D plastic model of the proximal femur and hemi-pelvis were fabricated using rapid-prototyping. Both the plastic model and the cadaver were then imaged using a high-resolution laser scanner. A three-way shape analysis was performed to compare the goodness-of-fit between the cadaver, image segmentation, and the plastic model. Overall, we obtained sub-millimeter fit accuracy between all three hip representations. Shape fit was least favorable in areas where the boundary between cartilage and bone is difficult to distinguish. We submit that rapid-prototyping is an accurate and efficient mechanism for obtaining 3D specimens as a means to further study the irregular geometry of the hip.
- 1 January 2011
- Vol. 163, 18-24
On the use of laser scans to validate reverse engineering of bony anatomy.
There is a growing body of evidence to suggest the arthritic hip is an irregularly-shaped, aspherical joint, especially in severely pathological cases. Current methods used to study the shape and motion of the hip in-vivo, are invasive and impractical. This study aimed to assess whether a plastic model of the hip joint can be accurately made from a pelvic CT scan. A cadaver hemi-pelvis was CT imaged and segmented from which a 3D plastic model of the proximal femur and hemi-pelvis were fabricated using rapid-prototyping. Both the plastic model and the cadaver were then imaged using a high-resolution laser scanner. A three-way shape analysis was performed to compare the goodness-of-fit between the cadaver, image segmentation, and the plastic model. Overall, we obtained sub-millimeter fit accuracy between all three hip representations. Shape fit was least favorable in areas where the boundary between cartilage and bone is difficult to distinguish. We submit that rapid-prototyping is an accurate and efficient mechanism for obtaining 3D specimens as a means to further study the irregular geometry of the hip.
- 1 January 2011
- Vol. 163, 283-9
Registration stability of physical templates in hip surgery.
We tested the registration stability of individualized templates in a consecutive study with 80 patients undergoing hip-resurfacing surgery. These templates physically encode registration and navigation parameters but do not require a computer during the actual surgery. The surgical target was the placement of the femoral guidance pin during hip resurfacing, which is a difficult and highly variable task using conventional instruments. The drill trajectory for the guidance pin of the femoral component was planned on a 3D computer model of the femur derived from a preoperative computed tomography (CT) scan. A surface-matched drilling template was designed to perform mechanical registration on the bone surface and had a hole for the drill guide; the template was created using a rapid prototyping machine. Intraoperatively, the individualized template was positioned on the patient anatomy and the pin was drilled into the femoral neck. The final achieved pin orientation and position were measured using an optoelectronic CT-based navigation system. The measured mean deviation between planned and actual central pin alignment of 0.05° in valgus and 2.8° in anteversion shows that the proposed individualized templates for hip resurfacing have reliable registration.
- 1 January 2011
- Vol. 163, 283-9
Registration stability of physical templates in hip surgery.
We tested the registration stability of individualized templates in a consecutive study with 80 patients undergoing hip-resurfacing surgery. These templates physically encode registration and navigation parameters but do not require a computer during the actual surgery. The surgical target was the placement of the femoral guidance pin during hip resurfacing, which is a difficult and highly variable task using conventional instruments. The drill trajectory for the guidance pin of the femoral component was planned on a 3D computer model of the femur derived from a preoperative computed tomography (CT) scan. A surface-matched drilling template was designed to perform mechanical registration on the bone surface and had a hole for the drill guide; the template was created using a rapid prototyping machine. Intraoperatively, the individualized template was positioned on the patient anatomy and the pin was drilled into the femoral neck. The final achieved pin orientation and position were measured using an optoelectronic CT-based navigation system. The measured mean deviation between planned and actual central pin alignment of 0.05° in valgus and 2.8° in anteversion shows that the proposed individualized templates for hip resurfacing have reliable registration.