Brad W. Hanks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brad W. Hanks has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Brian D. Jensen
Department of Mechanical Engineering, Brigham Young University, Provo, UT, USA
3 shared publications - John Sessions
Department of Forest Engineering, Resources and Management, Oregon State University, Corvallis, OR, USA
3 shared publications - Dallin L. Lindstrom
Department of Exercise Science, Brigham Young University, Provo, UT 84602, USA
2 shared publications - Sandra Hope
Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT 84602, USA
2 shared publications - Craig S. Skousen
Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT USA
1 shared publication - Jonathan K. Alder
University of Pittsburgh Division of Pulmonary, Allergy, Critical Care and Sleep Medicine; University of Pittsburgh Lung Transplant Research Center
1 shared publication
Latest Publications
- Open Access
- 9 September 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1521
CRISPR-Cas9 directed knock-out of a constitutively expressed gene using lance array nanoinjection
CRISPR-Cas9 genome editing and labeling has emerged as an important tool in biologic research, particularly in regards to potential transgenic and gene therapy applications. Delivery of CRISPR-Cas9 plasmids to target cells is typically done by non-viral methods (chemical, physical, and/or electrical), which are limited by low transfection efficiencies or with viral vectors, which are limited by safety and restricted volume size. In this work, a non-viral transfection technology, named lance array nanoinjection (LAN), utilizes a microfabricated silicon chip to physically and electrically deliver genetic material to large numbers of target cells. To demonstrate its utility, we used the CRISPR-Cas9 system to edit the genome of isogenic cells. Two variables related to the LAN process were tested which include the magnitude of current used during plasmid attraction to the silicon lance array (1.5, 4.5, or 6.0 mA) and the number of times cells were injected (one or three times). Results indicate that most successful genome editing occurred after injecting three times at a current control setting of 4.5 mA, reaching a median level of 93.77 % modification. Furthermore, we found that genome editing using LAN follows a non-linear injection-dose response, meaning samples injected three times had modification rates as high as nearly 12 times analogously treated single injected samples. These findings demonstrate the LAN’s ability to deliver genetic material to cells and indicate that successful alteration of the genome is influenced by a serial injection method as well as the electrical current settings.
- 9 September 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1521
Open AccessCRISPR-Cas9 directed knock-out of a constitutively expressed gene using lance array nanoinjection
CRISPR-Cas9 genome editing and labeling has emerged as an important tool in biologic research, particularly in regards to potential transgenic and gene therapy applications. Delivery of CRISPR-Cas9 plasmids to target cells is typically done by non-viral methods (chemical, physical, and/or electrical), which are limited by low transfection efficiencies or with viral vectors, which are limited by safety and restricted volume size. In this work, a non-viral transfection technology, named lance array nanoinjection (LAN), utilizes a microfabricated silicon chip to physically and electrically deliver genetic material to large numbers of target cells. To demonstrate its utility, we used the CRISPR-Cas9 system to edit the genome of isogenic cells. Two variables related to the LAN process were tested which include the magnitude of current used during plasmid attraction to the silicon lance array (1.5, 4.5, or 6.0 mA) and the number of times cells were injected (one or three times). Results indicate that most successful genome editing occurred after injecting three times at a current control setting of 4.5 mA, reaching a median level of 93.77 % modification. Furthermore, we found that genome editing using LAN follows a non-linear injection-dose response, meaning samples injected three times had modification rates as high as nearly 12 times analogously treated single injected samples. These findings demonstrate the LAN’s ability to deliver genetic material to cells and indicate that successful alteration of the genome is influenced by a serial injection method as well as the electrical current settings.
- Open Access
- 22 February 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (4) , 045002
The effect of lance geometry and carbon coating of silicon lances on propidium iodide uptake in lance array nanoinjection of HeLa 229 cells
Connecting technology to biologic discovery is a core focus of non-viral gene therapy biotechnologies. One approach that leverages both the physical and electrical function of microelectromechanical systems (MEMS) in cellular engineering is a technology previously described as lance array nanoinjection (LAN). In brief, LAN consists of a silicon chip measuring 2 cm by 2 cm that has been etched to contain an array of 10 μm tall, solid lances that are spaced every 10 μm in a grid pattern. This array of lances is used to physically penetrate hundreds of thousands of cells simultaneously and to then electrically deliver molecular loads into cells. In this present work, two variables related to the microfabrication of the silicon lances, namely lance geometry and coating, are investigated. The purpose of both experimental variables is to assess these parameters' effect on propidium iodide (PI), a cell membrane impermeable dye, uptake to injected HeLa 229 cells. For the lance geometry experimentation, three different microfabricated lance geometries were used which include a flat/narrow (FN, 1 μm diameter), flat/wide (FW, 2–2.5 μm diameter), and pointed (P, 1 μm diameter) lance geometries. From these tests, it was shown that the FN lances had a slightly better cell viability rate of 91.73% and that the P lances had the best PI uptake rate of 75.08%. For the lance coating experimentation, two different lances were fabricated, both silicon etched lances with some being carbon coated (CC) in a <100 nm layer of carbon and the other lances being non-coated (Si). Results from this experiment showed no significant difference between lance types at three different nanoinjection protocols (0V, +1.5V DC, and +5V Pulsed) for both cell viability and PI uptake rates. One exception to this is the comparison of CC/5V Pul and Si/5V Pul samples, where the CC/5V Pul samples had a cell viability rate 5% higher. Both outcomes were unexpected and reveal how to better optimize LAN parameters for future transfection experimentation.
- 22 February 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (4) , 045002
Open AccessThe effect of lance geometry and carbon coating of silicon lances on propidium iodide uptake in lance array nanoinjection of HeLa 229 cells
Connecting technology to biologic discovery is a core focus of non-viral gene therapy biotechnologies. One approach that leverages both the physical and electrical function of microelectromechanical systems (MEMS) in cellular engineering is a technology previously described as lance array nanoinjection (LAN). In brief, LAN consists of a silicon chip measuring 2 cm by 2 cm that has been etched to contain an array of 10 μm tall, solid lances that are spaced every 10 μm in a grid pattern. This array of lances is used to physically penetrate hundreds of thousands of cells simultaneously and to then electrically deliver molecular loads into cells. In this present work, two variables related to the microfabrication of the silicon lances, namely lance geometry and coating, are investigated. The purpose of both experimental variables is to assess these parameters' effect on propidium iodide (PI), a cell membrane impermeable dye, uptake to injected HeLa 229 cells. For the lance geometry experimentation, three different microfabricated lance geometries were used which include a flat/narrow (FN, 1 μm diameter), flat/wide (FW, 2–2.5 μm diameter), and pointed (P, 1 μm diameter) lance geometries. From these tests, it was shown that the FN lances had a slightly better cell viability rate of 91.73% and that the P lances had the best PI uptake rate of 75.08%. For the lance coating experimentation, two different lances were fabricated, both silicon etched lances with some being carbon coated (CC) in a <100 nm layer of carbon and the other lances being non-coated (Si). Results from this experiment showed no significant difference between lance types at three different nanoinjection protocols (0V, +1.5V DC, and +5V Pulsed) for both cell viability and PI uptake rates. One exception to this is the comparison of CC/5V Pul and Si/5V Pul samples, where the CC/5V Pul samples had a cell viability rate 5% higher. Both outcomes were unexpected and reveal how to better optimize LAN parameters for future transfection experimentation.
- 1 November 2015
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 6 (4) , 041005
Transient Low-Temperature Effects on Propidium Iodide Uptake in Lance Array Nanoinjected HeLa Cells
Understanding environmental factors relative to transfection protocols is key for improving genetic engineering outcomes. In the following work, the effects of temperature on a nonviral transfection procedure previously described as lance array nanoinjection are examined in context of molecular delivery of propidium iodide (PI), a cell membrane impermeable nucleic acid dye, to HeLa 229 cells. For treatment samples, variables include varying the temperature of the injection solution (3C and 23C) and the magnitude of the pulsed voltage used during lance insertion into the cells (+5 V and +7 V). Results indicate that PI is delivered at levels significantly higher for samples injected at 3C as opposed to 23C at four different postinjection intervals (t = 0, 3, 6, 9 mins; p-value ≤ 0.005), reaching a maximum value of 8.3 times the positive control for 3 C/7 V pulsed samples. Suggested in this work is that between 3 and 6 mins postinjection, a large number of induced pores from the injection event close. While residual levels of PI still continue to enter the treatment samples after 6 mins, it occurs at decreased levels, suggesting from a physiological perspective that many lance array nanoinjection (LAN) induced pores have closed, some are still present.
- 1 November 2015
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 6 (4) , 041005
Transient Low-Temperature Effects on Propidium Iodide Uptake in Lance Array Nanoinjected HeLa Cells
Understanding environmental factors relative to transfection protocols is key for improving genetic engineering outcomes. In the following work, the effects of temperature on a nonviral transfection procedure previously described as lance array nanoinjection are examined in context of molecular delivery of propidium iodide (PI), a cell membrane impermeable nucleic acid dye, to HeLa 229 cells. For treatment samples, variables include varying the temperature of the injection solution (3C and 23C) and the magnitude of the pulsed voltage used during lance insertion into the cells (+5 V and +7 V). Results indicate that PI is delivered at levels significantly higher for samples injected at 3C as opposed to 23C at four different postinjection intervals (t = 0, 3, 6, 9 mins; p-value ≤ 0.005), reaching a maximum value of 8.3 times the positive control for 3 C/7 V pulsed samples. Suggested in this work is that between 3 and 6 mins postinjection, a large number of induced pores from the injection event close. While residual levels of PI still continue to enter the treatment samples after 6 mins, it occurs at decreased levels, suggesting from a physiological perspective that many lance array nanoinjection (LAN) induced pores have closed, some are still present.