Hugo Bergeron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hugo Bergeron has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Laura C. Sinclair
National Institute of Standards and Technology, 325 Broadway, Boulder, CO, United States
2 shared publications- Nathan R. Newbury
National Institute of Standards and Technology, Boulder, USA
2 shared publications William C. Swann
National Institute of Standards and Technology, 325 Broadway, Boulder, CO, United States
2 shared publicationsCraig W. Nelson
National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305, USA
1 shared publication- Esther Baumann
National Institute of Standards and Technology, Boulder, USA
1 shared publication - Fabrizio R. Giorgetta
National Institute of Standards and Technology, Boulder, USA
1 shared publication
Latest Publications
- 1 January 2018
- Published by Optica Publishing Group
- p. SM1L.3
Femtosecond Synchronization through Turbulent Air Off a Quadcopter
We demonstrate femtosecond-level synchronization of optical oscillators connected via a moving quadcopter. Synchronization is achieved despite 20 m/s motion and 500 m pathlength changes.
- 1 January 2018
- Published by Optica Publishing Group
- p. SM1L.3
Femtosecond Synchronization through Turbulent Air Off a Quadcopter
We demonstrate femtosecond-level synchronization of optical oscillators connected via a moving quadcopter. Synchronization is achieved despite 20 m/s motion and 500 m pathlength changes.
- Open Access
- 15 April 2016
- Published by Optica Publishing Group in Optica
- Vol. 3 (4) , 441-447
Tight real-time synchronization of a microwave clock to an optical clock across a turbulent air path
The ability to distribute the precise time and frequency from an optical clock to remote platforms could enable future precise navigation and sensing systems. Here, we demonstrate tight, real-time synchronization of a remote microwave clock to a master optical clock over a turbulent 4 km open-air path via optical two-way time–frequency transfer. Once synchronized, the 10 GHz frequency signals generated at each site agree to at 1 s and below at 1000 s. In addition, the two clock times are synchronized to over an 8-hour period. The ability to phase-synchronize 10 GHz signals across platforms supports future distributed coherent sensing, while the ability to time-synchronize multiple microwave-based clocks to a high-performance master optical clock supports future precision navigation/timing systems.- 15 April 2016
- Published by Optica Publishing Group in Optica
- Vol. 3 (4) , 441-447
Open AccessTight real-time synchronization of a microwave clock to an optical clock across a turbulent air path
The ability to distribute the precise time and frequency from an optical clock to remote platforms could enable future precise navigation and sensing systems. Here, we demonstrate tight, real-time synchronization of a remote microwave clock to a master optical clock over a turbulent 4 km open-air path via optical two-way time–frequency transfer. Once synchronized, the 10 GHz frequency signals generated at each site agree to at 1 s and below at 1000 s. In addition, the two clock times are synchronized to over an 8-hour period. The ability to phase-synchronize 10 GHz signals across platforms supports future distributed coherent sensing, while the ability to time-synchronize multiple microwave-based clocks to a high-performance master optical clock supports future precision navigation/timing systems.