Norman Uhlmann
Norman Uhlmann has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Arzig
Friedrich-Alexander University of Erlangen-Nürnberg
3 shared publications - Michael Salamon
Fraunhofer Institute for Integrated Circuits (IIS) Flugplatzstr. 75 90768 Fürth Germany
3 shared publications - Peter J. Wellmann
Friedrich-Alexander-Universität Erlangen-Nürnberg
3 shared publications - Stefan Gerth
Development Center X-Ray Technology , Fraunhofer IIS , Flugplatzstr. 75, 90768 Fürth , Germany
3 shared publications Michael Salamon
2 shared publications- Anja Eggert
Development Center X-Ray Technology EZRT, Fraunhofer Institute for Integrated Systems IIS, Flugplatzstraße 75, 90768 Fürth, Germany
1 shared publication
Latest Publications
- 28 June 2022
- Published by Burleigh Dodds Science Publishing Limited
- p. 123-150
Advances in the use of X-ray computed tomography in crop phenotyping
- 28 June 2022
- Published by Burleigh Dodds Science Publishing Limited
- p. 123-150
Advances in the use of X-ray computed tomography in crop phenotyping
- Open Access
- 25 November 2020
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (1) , 1-14
Exploring Flood Filling Networks for Instance Segmentation of XXL-Volumetric and Bulk Material CT Data
XXL-Computed Tomography (XXL-CT) is able to produce large scale volume datasets of scanned objects such as crash tested cars, sea and aircraft containers or cultural heritage objects. The acquired image data consists of volumes of up to and above $$\hbox {10,000}^{3}$$ voxels which can relate up to many terabytes in file size and can contain multiple 10,000 of different entities of depicted objects. In order to extract specific information about these entities from the scanned objects in such vast datasets, segmentation or delineation of these parts is necessary. Due to unknown and varying properties (shapes, densities, materials, compositions) of these objects, as well as interfering acquisition artefacts, classical (automatic) segmentation is usually not feasible. Contrarily, a complete manual delineation is error-prone and time-consuming, and can only be performed by trained and experienced personnel. Hence, an interactive and partial segmentation of so-called “chunks” into tightly coupled assemblies or sub-assemblies may help the assessment, exploration and understanding of such large scale volume data. In order to assist users with such an (possibly interactive) instance segmentation for the data exploration process, we propose to utilize delineation algorithms with an approach derived from flood filling networks. We present primary results of a flood filling network implementation adapted to non-destructive testing applications based on large scale CT from various test objects, as well as real data of an airplane and describe the adaptions to this domain. Furthermore, we address and discuss segmentation challenges due to acquisition artefacts such as scattered radiation or beam hardening resulting in reduced data quality, which can severely impair the interactive segmentation results.- 25 November 2020
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (1) , 1-14
Open AccessExploring Flood Filling Networks for Instance Segmentation of XXL-Volumetric and Bulk Material CT Data
XXL-Computed Tomography (XXL-CT) is able to produce large scale volume datasets of scanned objects such as crash tested cars, sea and aircraft containers or cultural heritage objects. The acquired image data consists of volumes of up to and above $$\hbox {10,000}^{3}$$ voxels which can relate up to many terabytes in file size and can contain multiple 10,000 of different entities of depicted objects. In order to extract specific information about these entities from the scanned objects in such vast datasets, segmentation or delineation of these parts is necessary. Due to unknown and varying properties (shapes, densities, materials, compositions) of these objects, as well as interfering acquisition artefacts, classical (automatic) segmentation is usually not feasible. Contrarily, a complete manual delineation is error-prone and time-consuming, and can only be performed by trained and experienced personnel. Hence, an interactive and partial segmentation of so-called “chunks” into tightly coupled assemblies or sub-assemblies may help the assessment, exploration and understanding of such large scale volume data. In order to assist users with such an (possibly interactive) instance segmentation for the data exploration process, we propose to utilize delineation algorithms with an approach derived from flood filling networks. We present primary results of a flood filling network implementation adapted to non-destructive testing applications based on large scale CT from various test objects, as well as real data of an airplane and describe the adaptions to this domain. Furthermore, we address and discuss segmentation challenges due to acquisition artefacts such as scattered radiation or beam hardening resulting in reduced data quality, which can severely impair the interactive segmentation results. - Open Access
Influence of the growth interface shape on the defect characteristics in the facet region of 4H-SiC single crystals
Two 75mm 4H-SiC single crystals are grown by the physical vapor transport (PVT) technique, using different insulation materials. The insulation material of higher thermal conductivity led to an increased radial temperature gradient. The evolution of the growth front was monitored using the in-situ computed tomography (CT). A slightly bent growth interface and a bigger facet are formed during the growth applying a lower radial temperature gradient while a smaller facet and steeper crystal flanks are formed in the case of the larger radial temperature gradient. Micropipes are deflected laterally by large surface steps on the steep crystal flanks and a reduction of threading edge dislocations by 60% is revealed by KOH defect etching.
Open AccessInfluence of the growth interface shape on the defect characteristics in the facet region of 4H-SiC single crystals
Two 75mm 4H-SiC single crystals are grown by the physical vapor transport (PVT) technique, using different insulation materials. The insulation material of higher thermal conductivity led to an increased radial temperature gradient. The evolution of the growth front was monitored using the in-situ computed tomography (CT). A slightly bent growth interface and a bigger facet are formed during the growth applying a lower radial temperature gradient while a smaller facet and steeper crystal flanks are formed in the case of the larger radial temperature gradient. Micropipes are deflected laterally by large surface steps on the steep crystal flanks and a reduction of threading edge dislocations by 60% is revealed by KOH defect etching.
- Open Access
Comparison of Achievable Contrast Features in Computed Tomography Observing the Growth of a 4H-SiC Bulk Crystal
Today the physical vapor transport process is regularly applied for the growth of bulk SiC crystals. Due to the required high temperature of up to 2400 °C, and low gas pressure of several Mbar inside the crucible, the systems are encapsulated by several layers for heating, cooling and isolation inhibiting the operator from observing the growth. Also, the crucible itself is fully encapsulated to avoid impurities from being inserted into the crystal or disturbing the temperature field distribution. Thus, once the crucible has been set up with SiC powder and the seed crystal, the visible access to the progress of growth is limited. In the past, X-ray radiography has allowed this limitation to be overcome by placing the crucible in between an X-ray source and a radiographic film. Recently these two-dimensional attenuation signals have been extended to three-dimensional density distribution by the technique of computed tomography (CT). Beside the classic X-ray attenuation signal dominated by photoelectric effect, Compton effect and Rayleigh scattering, X-ray diffraction resulting in the crystalline structure of the 4H-SiC superimposes the reconstructed result. In this contribution, the achievable material contrast related to the level of X-ray energy and the absorption effects is analyzed using different CT systems with energies from 125 kV to 9 MeV. Furthermore the X-ray diffraction influence is shown by the comparison between the advanced helical-CT method and the classical 3D-CT.
Open AccessComparison of Achievable Contrast Features in Computed Tomography Observing the Growth of a 4H-SiC Bulk Crystal
Today the physical vapor transport process is regularly applied for the growth of bulk SiC crystals. Due to the required high temperature of up to 2400 °C, and low gas pressure of several Mbar inside the crucible, the systems are encapsulated by several layers for heating, cooling and isolation inhibiting the operator from observing the growth. Also, the crucible itself is fully encapsulated to avoid impurities from being inserted into the crystal or disturbing the temperature field distribution. Thus, once the crucible has been set up with SiC powder and the seed crystal, the visible access to the progress of growth is limited. In the past, X-ray radiography has allowed this limitation to be overcome by placing the crucible in between an X-ray source and a radiographic film. Recently these two-dimensional attenuation signals have been extended to three-dimensional density distribution by the technique of computed tomography (CT). Beside the classic X-ray attenuation signal dominated by photoelectric effect, Compton effect and Rayleigh scattering, X-ray diffraction resulting in the crystalline structure of the 4H-SiC superimposes the reconstructed result. In this contribution, the achievable material contrast related to the level of X-ray energy and the absorption effects is analyzed using different CT systems with energies from 125 kV to 9 MeV. Furthermore the X-ray diffraction influence is shown by the comparison between the advanced helical-CT method and the classical 3D-CT.
- Open Access
Influence of Morphological Changes in a Source Material on the Growth Interface of 4H-SiC Single Crystals
In this study, the change of mass distribution in a source material is tracked using an in situ computer tomography (CT) setup during the bulk growth of 4H- silicon carbide (SiC) via physical vapor depostion (PVT). The changing properties of the source material due to recrystallization and densification are evaluated. Laser flash measurement showed that the thermal properties of different regions of the source material change significantly before and after the growth run. The Si-depleted area at the bottom of the crucible is thermally insulating, while the residual SiC source showed increased thermal conductivity compared to the initially charged powder. Ex situ CT measurements revealed a needle-like structure with elongated pores causing anisotropic behavior for the heat conductivity. Models to assess the thermal conductivity are applied in order to calculate the changes in the temperature field in the crucible and the changes in growth kinetics are discussed.
Open AccessInfluence of Morphological Changes in a Source Material on the Growth Interface of 4H-SiC Single Crystals
In this study, the change of mass distribution in a source material is tracked using an in situ computer tomography (CT) setup during the bulk growth of 4H- silicon carbide (SiC) via physical vapor depostion (PVT). The changing properties of the source material due to recrystallization and densification are evaluated. Laser flash measurement showed that the thermal properties of different regions of the source material change significantly before and after the growth run. The Si-depleted area at the bottom of the crucible is thermally insulating, while the residual SiC source showed increased thermal conductivity compared to the initially charged powder. Ex situ CT measurements revealed a needle-like structure with elongated pores causing anisotropic behavior for the heat conductivity. Models to assess the thermal conductivity are applied in order to calculate the changes in the temperature field in the crucible and the changes in growth kinetics are discussed.
- Open Access
- 1 February 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (2) , 025108
Correction of beam hardening in X-ray radiograms
The intensity of a monochromatic X-ray beam decreases exponentially with the distance it has traveled inside a material; this behavior is commonly referred to as Beer-Lambert’s law. Knowledge of the material-specific attenuation coefficient μ allows us to determine the thickness of a sample from the intensity decrease the beam has experienced. However, classical X-ray tubes emit a polychromatic bremsstrahlung-spectrum. And the attenuation coefficients of all materials depend on the photon energy: photons with high energy are attenuated less than photons with low energy. In consequence, the X-ray spectrum changes while traveling through the medium; due to the relative increase in high energy photons, this effect is called beam hardening. For this varying spectrum, the Beer-Lambert law only remains valid if μ is replaced by an effective attenuation coefficient μeff which depends not only on the material but also on its thickness x and the details of the X-ray setup used. We present here a way to deduce μeff(x) from a small number of auxiliary measurements using a phenomenological model. This model can then be used to determine an unknown material thickness or in the case of a granular media its volume fraction.
- 1 February 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (2) , 025108
Open AccessCorrection of beam hardening in X-ray radiograms
The intensity of a monochromatic X-ray beam decreases exponentially with the distance it has traveled inside a material; this behavior is commonly referred to as Beer-Lambert’s law. Knowledge of the material-specific attenuation coefficient μ allows us to determine the thickness of a sample from the intensity decrease the beam has experienced. However, classical X-ray tubes emit a polychromatic bremsstrahlung-spectrum. And the attenuation coefficients of all materials depend on the photon energy: photons with high energy are attenuated less than photons with low energy. In consequence, the X-ray spectrum changes while traveling through the medium; due to the relative increase in high energy photons, this effect is called beam hardening. For this varying spectrum, the Beer-Lambert law only remains valid if μ is replaced by an effective attenuation coefficient μeff which depends not only on the material but also on its thickness x and the details of the X-ray setup used. We present here a way to deduce μeff(x) from a small number of auxiliary measurements using a phenomenological model. This model can then be used to determine an unknown material thickness or in the case of a granular media its volume fraction.
- Open Access
- 11 March 2015
- Published by Springer Nature in Plant Methods
- Vol. 11 (1) , 17-11
Direct comparison of MRI and X-ray CT technologies for 3D imaging of root systems in soil: potential and challenges for root trait quantification
Roots are vital to plants for soil exploration and uptake of water and nutrients. Root performance is critical for growth and yield of plants, in particular when resources are limited. Since roots develop in strong interaction with the soil matrix, tools are required that can visualize and quantify root growth in opaque soil at best in 3D. Two modalities that are suited for such investigations are X-ray Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Due to the different physical principles they are based on, these modalities have their specific potentials and challenges for root phenotyping. We compared the two methods by imaging the same root systems grown in 3 different pot sizes with inner diameters of 34 mm, 56 mm or 81 mm. Both methods successfully visualized roots of two weeks old bean plants in all three pot sizes. Similar root images and almost the same root length were obtained for roots grown in the small pot, while more root details showed up in the CT images compared to MRI. For the medium sized pot, MRI showed more roots and higher root lengths whereas at some spots thin roots were only found by CT and the high water content apparently affected CT more than MRI. For the large pot, MRI detected much more roots including some laterals than CT. Both techniques performed equally well for pots with small diameters which are best suited to monitor root development of seedlings. To investigate specific root details or finely graduated root diameters of thin roots, CT was advantageous as it provided the higher spatial resolution. For larger pot diameters, MRI delivered higher fractions of the root systems than CT, most likely because of the strong root-to-soil contrast achievable by MRI. Since complementary information can be gathered with CT and MRI, a combination of the two modalities could open a whole range of additional possibilities like analysis of root system traits in different soil structures or under varying soil moisture.
- 11 March 2015
- Published by Springer Nature in Plant Methods
- Vol. 11 (1) , 17-11
Open AccessDirect comparison of MRI and X-ray CT technologies for 3D imaging of root systems in soil: potential and challenges for root trait quantification
Roots are vital to plants for soil exploration and uptake of water and nutrients. Root performance is critical for growth and yield of plants, in particular when resources are limited. Since roots develop in strong interaction with the soil matrix, tools are required that can visualize and quantify root growth in opaque soil at best in 3D. Two modalities that are suited for such investigations are X-ray Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Due to the different physical principles they are based on, these modalities have their specific potentials and challenges for root phenotyping. We compared the two methods by imaging the same root systems grown in 3 different pot sizes with inner diameters of 34 mm, 56 mm or 81 mm. Both methods successfully visualized roots of two weeks old bean plants in all three pot sizes. Similar root images and almost the same root length were obtained for roots grown in the small pot, while more root details showed up in the CT images compared to MRI. For the medium sized pot, MRI showed more roots and higher root lengths whereas at some spots thin roots were only found by CT and the high water content apparently affected CT more than MRI. For the large pot, MRI detected much more roots including some laterals than CT. Both techniques performed equally well for pots with small diameters which are best suited to monitor root development of seedlings. To investigate specific root details or finely graduated root diameters of thin roots, CT was advantageous as it provided the higher spatial resolution. For larger pot diameters, MRI delivered higher fractions of the root systems than CT, most likely because of the strong root-to-soil contrast achievable by MRI. Since complementary information can be gathered with CT and MRI, a combination of the two modalities could open a whole range of additional possibilities like analysis of root system traits in different soil structures or under varying soil moisture.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8506, 850617
High-resolution and high-speed CT in industry and research
The application of industrial CT covers many orders of magnitude of object sizes, ranging from freight containers (few meters) down to liquid foams (i.e. for food industry) or even parts of insects which are only several hundreds of micrometers in size. Similarly, the specifications for acquisition speed extend over some orders of magnitude, from hours to sub-second CT. We present the current technology in terms of X-ray sources and detectors, along with numerous applications from industry and materials research: e.g. industrial high-speed CT of car pistons, in situ micro-CT of milk foam decay at micrometer spatial resolution and 8 s scan time, as well as ex situ scans of tensile tested Nickel-alloys. The Fraunhofer Development Center X-ray Technology (Fürth, Germany) and the Chair of X-ray Microscopy (University Würzburg, Germany) are currently working on extending the technological limits, demonstrated, e,g. by the development of advanced X-ray detectors or a new inhouse CT system which comprises a high-brilliance liquid metal jet anode.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8506, 850617
High-resolution and high-speed CT in industry and research
The application of industrial CT covers many orders of magnitude of object sizes, ranging from freight containers (few meters) down to liquid foams (i.e. for food industry) or even parts of insects which are only several hundreds of micrometers in size. Similarly, the specifications for acquisition speed extend over some orders of magnitude, from hours to sub-second CT. We present the current technology in terms of X-ray sources and detectors, along with numerous applications from industry and materials research: e.g. industrial high-speed CT of car pistons, in situ micro-CT of milk foam decay at micrometer spatial resolution and 8 s scan time, as well as ex situ scans of tensile tested Nickel-alloys. The Fraunhofer Development Center X-ray Technology (Fürth, Germany) and the Chair of X-ray Microscopy (University Würzburg, Germany) are currently working on extending the technological limits, demonstrated, e,g. by the development of advanced X-ray detectors or a new inhouse CT system which comprises a high-brilliance liquid metal jet anode.
- Open Access
- 1 January 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (01) , C01095
Simulation study of a highly efficient, high resolution X-ray sensor based on self-organizing aluminum oxide
State of the art X-ray imaging sensors comprise a trade-off between the achievable efficiency and the spatial resolution. To overcome such limitations, the use of structured and scintillator filled aluminum oxide (AlOx) matrices has been investigated. We used Monte-Carlo (MC) X-ray simulations to determine the X-ray imaging quality of these AlOx matrices. Important factors which influence the behavior of the matrices are: filling factor (surface ratio between channels and `closed` AlOx), channel diameter, aspect ratio, filling material etc. Therefore we modeled the porous AlOx matrix in several different ways with the MC X-ray simulation tool ROSI [1] and evaluated its properties to investigate the achievable performance at different X-ray spectra, with different filling materials (i.e. scintillators) and varying channel height and pixel readout. In this paper we focus on the quantum efficiency, the spatial resolution and image homogeneity.
- 1 January 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (01) , C01095
Open AccessSimulation study of a highly efficient, high resolution X-ray sensor based on self-organizing aluminum oxide
State of the art X-ray imaging sensors comprise a trade-off between the achievable efficiency and the spatial resolution. To overcome such limitations, the use of structured and scintillator filled aluminum oxide (AlOx) matrices has been investigated. We used Monte-Carlo (MC) X-ray simulations to determine the X-ray imaging quality of these AlOx matrices. Important factors which influence the behavior of the matrices are: filling factor (surface ratio between channels and `closed` AlOx), channel diameter, aspect ratio, filling material etc. Therefore we modeled the porous AlOx matrix in several different ways with the MC X-ray simulation tool ROSI [1] and evaluated its properties to investigate the achievable performance at different X-ray spectra, with different filling materials (i.e. scintillators) and varying channel height and pixel readout. In this paper we focus on the quantum efficiency, the spatial resolution and image homogeneity.