MMMohammad Mehdi Movahedi

Mohammad Mehdi Movahedi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Mehdi Movahedi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Hardware-Software System for Accurate Segmentation of Phonocardiogram Signal

    by Mohammad Mehdi Movahedi, Mohamadreza Shakerpour, Shahrokh Mousavi, Ahmad Nori, Seyyed Hesam Mousavian Dehkordi, Hossein Parsaei

    Background: Phonocardiogram (PCG) signal provides valuable information for diagnosing heart diseases. However, its applications in quantitative analyses of heart function are limited because the interpretation of this signal is difficult. A key step in quantitative PCG is the identification of the first and second sounds (S1 and S2) in this signal. Objective: This study aims to develop a hardware-software system for synchronized acquisition of two signals electrocardiogram (ECG) and PCG and to segment the recorded PCG signal via the information provided in the acquired ECG signal. Material and Methods: In this analytical study, we developed a hardware-software system for real-time identification of the first and second heart sounds in the PCG signal. A portable device to capture synchronized ECG and PCG signals was developed. Wavelet de-noising technique was used to remove noise from the signal. Finally, by fusing the information provided by the ECG signal (R-peaks and T-end) into a hidden Markov model (HMM), the first and second heart sounds were identified in the PCG signal. Results: ECG and PCG signals from 15 healthy adults were acquired and analyzed using the developed system. The average accuracy of the system in correctly detecting the heart sounds was 95.6% for S1 and 93.4% for S2. Conclusion: The presented system is cost-effective, user-friendly, and accurate in identifying S1 and S2 in PCG signals. Therefore, it might be effective in quantitative PCG and diagnosing heart diseases.


  • Open Access

    Investigation Myocardial Perfusion Scan Parameters and Walls Motion in Patients undergoing Cardiac Surgery

    by Mohammad Mehdi Movahedi, Hamidreza Arianfar, Mohammad Atefi, Ali Tavakoli Golpaygani, Farshid Gheisari, Tahereh Mahmoudi

    Background: Coronary heart disease the most prevalent form of cardiovascular disease, results from the blockage of blood flow through arteries. The Myocardial Perfusion Scan (MPS) is considered a non-invasive method to assess the heart condition and provides valuable information, such as End Diastolic Volume (EDV), End Systolic Volume (ESV), Ejection Fraction (EF), Lung to Heart Ratio (LHR), and Transient Ischemic Dilatation (TID).Objective: This study aimed to investigate changes in gated heart scan parameters to diagnose patients, who are candidates for heart surgery.Material and Methods: In this descriptive cross-sectional study, 40 patients who are candidates for heart surgery were enrolled to evaluate the relation between the parameters of the gated heart scan and the amount of ischemic area of the heart. After scanning the patients, TID, ESV, LHR, and EF and also the movements of the heart walls are examined and analyzed in these patients.Results: According to the results of the one-sample t-test showing a significant difference between the parameters, the results were within the normal range (P-value<0.0001). Additionally, all patients showed changes in cardiac output and wall movement issues. Conclusion: The evaluation of Myocardial Perfusion Scan (MPS) and gated heart scan parameters can provide an effective method for diagnosing patients who may require heart surgery.

  • Open Access

    Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran

    by Seyed Mohammad Javad Mortazavi, Samira Zarei, Mohammad Taheri, Saeed Tajbakhsh, Sahar Ranjbar, Fatemeh Momeni, Samaneh Masoomi, Leila Ansari, Mohammad Mehdi Movahedi, Shahram Taeb, et al.

    Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran


  • 3D cerebral MR image segmentation using multiple-classifier system

    by Saba Amiri, Mohammad Mehdi Movahedi, Kamran Kazemi, Hossein Parsaei

    The three soft brain tissues white matter (WM), gray matter (GM), and cerebral spinal fluid (CSF) identified in a magnetic resonance (MR) image via image segmentation techniques can aid in structural and functional brain analysis, brain’s anatomical structures measurement and visualization, neurodegenerative disorders diagnosis, and surgical planning and image-guided interventions, but only if obtained segmentation results are correct. This paper presents a multiple-classifier-based system for automatic brain tissue segmentation from cerebral MR images. The developed system categorizes each voxel of a given MR image as GM, WM, and CSF. The algorithm consists of preprocessing, feature extraction, and supervised classification steps. In the first step, intensity non-uniformity in a given MR image is corrected and then non-brain tissues such as skull, eyeballs, and skin are removed from the image. For each voxel, statistical features and non-statistical features were computed and used a feature vector representing the voxel. Three multilayer perceptron (MLP) neural networks trained using three different datasets were used as the base classifiers of the multiple-classifier system. The output of the base classifiers was fused using majority voting scheme. Evaluation of the proposed system was performed using Brainweb simulated MR images with different noise and intensity non-uniformity and internet brain segmentation repository (IBSR) real MR images. The quantitative assessment of the proposed method using Dice, Jaccard, and conformity coefficient metrics demonstrates improvement (around 5 % for CSF) in terms of accuracy as compared to single MLP classifier and the existing methods and tools such FSL-FAST and SPM. As accurately segmenting a MR image is of paramount importance for successfully promoting the clinical application of MR image segmentation techniques, the improvement obtained by using multiple-classifier-based system is encouraging.


    • 8 March 2014
      • Vol. 4  (1) , 9-12
    Open Access

    Production of a Novel Mineral-based Sun Lotion for Protecting the Skin from Biohazards of Electromagnetic Radiation in the UV Region

    by M M Movahedi, A Alipour, S A R Mortazavi, M Tayebi

    Background: Sun protection materials have been one of the major concerns in pharmaceutical in­dustry since almost one century ago. Various materials have been found to have such an effect but there are still many unknown substances that have not been discovered.


  • Open Access

    Novel paint design based on nanopowder to protection against X and gamma rays

    by Mohammad Mehdi Movahedi, Adibe Abdi, Alireza Mehdizadeh, Naser Dehghan, Emad Heidari, Yusef Masumi, Mojtaba Abbaszadeh

    Background: Lead-based shields are the standard method of intraoperative radiation protection in the radiology and nuclear medicine department. Human lead toxicity is well documented. The lead used is heavy, lacks durability, is difficult to launder, and its disposal is associated with environmental hazards. The aim of this study was to design a lead free paint for protection against X and gamma rays. Materials and Methods: In this pilot st we evaluated several types of nano metal powder that seemed to have good absorption. The Monte Carlo code, MCNP4C, was used to model the attenuation of X-ray photons in paints with different designs. Experimental measurements were carried out to assess the attenuation properties of each paint design. Results: Among the different nano metal powder, nano tungsten trioxide and nano tin dioxide were the two most appropriate candidates for making paint in diagnostic photon energy range. Nano tungsten trioxide (15%) and nano tin dioxide (85%) provided the best protection in both simulation and experiments. After this step, attempts were made to produce appropriate nano tungsten trioxide-nano tin dioxide paints. The density of this nano tungsten trioxide-nano tin dioxide paint was 4.2 g/cm 3 . The MCNP simulation and experimental measurements for HVL (Half-Value Layer) values of this shield at 100 kVp were 0.25 and 0.23 mm, respectively. Conclusions: The results showed the cost-effective lead-free paint can be a great power in absorbing the X-rays and gamma rays and it can be used instead of lead.


    • 17 September 2013
      • Vol. 3  (3) , 81-86
    Open Access

    Development of a Brain Computer Interface (BCI) Speller System Based on SSVEP Signals

    by Mohammad Mehdi Movahedi, Alireza Mehdizadeh, Abolfazl Alipour

    BCI is one of the most intriguing technologies among other HCI systems, mostly because of its capability of recording brain activities. Spelling BCIs, which help paralyzed people to maintain communication, are one of the striking topics in the field of BCI. In this scientific a spelling BCI system with high transfer rate and accuracy that uses SSVEP signals is proposed.


  • The use of artificial neural networks and multiple linear regression to predict rate of medical waste generation

    by Sepideh Jahandideh, Samad Jahandideh, Ebrahim Barzegari Asadabadi, Mehrdad Askarian, Mohammad Mehdi Movahedi, Somayyeh Hosseini, Mina Jahandideh


  • Comparing performances of logistic regression and neural networks for predicting melatonin excretion patterns in the rat exposed to ELF magnetic fields

    by Samad Jahandideh, Parviz Abdolmaleki, Mohammad Mehdi Movahedi

    Various studies have been reported on the bioeffects of magnetic field exposure; however, no consensus or guideline is available for experimental designs relating to exposure conditions as yet. In this study, logistic regression (LR) and artificial neural networks (ANNs) were used in order to analyze and predict the melatonin excretion patterns in the rat exposed to extremely low frequency magnetic fields (ELF‐MF). Subsequently, on a database containing 33 experiments, performances of LR and ANNs were compared through resubstitution and jackknife tests. Predictor variables were more effective parameters and included frequency, polarization, exposure duration, and strength of magnetic fields. Also, five performance measures including accuracy, sensitivity, specificity, Matthew's Correlation Coefficient (MCC) and normalized percentage, better than random (S) were used to evaluate the performance of models. The LR as a conventional model obtained poor prediction performance. Nonetheless, LR distinguished the duration of magnetic fields as a statistically significant parameter. Also, horizontal polarization of magnetic fields with the highest logit coefficient (or parameter estimate) with negative sign was found to be the strongest indicator for experimental designs relating to exposure conditions. This means that each experiment with horizontal polarization of magnetic fields has a higher probability to result in “not changed melatonin level” pattern. On the other hand, ANNs, a more powerful model which has not been introduced in predicting melatonin excretion patterns in the rat exposed to ELF‐MF, showed high performance measure values and higher reliability, especially obtaining 0.55 value of MCC through jackknife tests. Obtained results showed that such predictor models are promising and may play a useful role in defining guidelines for experimental designs relating to exposure conditions. In conclusion, analysis of the bioelectromagnetic data could result in finding a relationship between electromagnetic fields and different biological processes. Bioelectromagnetics 31:164–171, 2010.