Marianthi‐Vasiliki Papoutsaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marianthi‐Vasiliki Papoutsaki has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- David J. Collins
Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom
2 shared publications - Jessica M. Winfield
The Royal Marsden NHS Foundation Trust, London, United Kingdom
2 shared publications - Michael A. Boss
Center for Research and Innovation, American College of Radiology, Philadelphia, USA
2 shared publications - Nandita Maria Desouza
Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom
2 shared publications - Alan Jackson
University of Manchester
1 shared publication - Alexander Weller
Departments of Radiology, Northwick Park and Central Middlesex Hospitals, London North West University Healthcare NHS Trust, Watford Road, Harrow HA1 3UJ, UK
1 shared publication
Latest Publications
- Open Access
- 27 September 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (3) , 1118-1131
Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives
For body imaging, diffusion-weighted MRI may be used for tumour detection, staging, prognostic information, assessing response and follow-up. Disease detection and staging involve qualitative, subjective assessment of images, whereas for prognosis, progression or response, quantitative evaluation of the apparent diffusion coefficient (ADC) is required. Validation and qualification of ADC in multicentre trials involves examination of i) technical performance to determine biomarker bias and reproducibility and ii) biological performance to interrogate a specific aspect of biology or to forecast outcome. Unfortunately, the variety of acquisition and analysis methodologies employed at different centres make ADC values non-comparable between them. This invalidates implementation in multicentre trials and limits utility of ADC as a biomarker. This article reviews the factors contributing to ADC variability in terms of data acquisition and analysis. Hardware and software considerations are discussed when implementing standardised protocols across multi-vendor platforms together with methods for quality assurance and quality control. Processes of data collection, archiving, curation, analysis, central reading and handling incidental findings are considered in the conduct of multicentre trials. Data protection and good clinical practice are essential prerequisites. Developing international consensus of procedures is critical to successful validation if ADC is to become a useful biomarker in oncology. Key Points • Standardised acquisition/analysis allows quantification of imaging biomarkers in multicentre trials. • Establishing “precision” of the measurement in the multicentre context is essential. • A repository with traceable data of known provenance promotes further research.
- 27 September 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (3) , 1118-1131
Open AccessImplementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives
For body imaging, diffusion-weighted MRI may be used for tumour detection, staging, prognostic information, assessing response and follow-up. Disease detection and staging involve qualitative, subjective assessment of images, whereas for prognosis, progression or response, quantitative evaluation of the apparent diffusion coefficient (ADC) is required. Validation and qualification of ADC in multicentre trials involves examination of i) technical performance to determine biomarker bias and reproducibility and ii) biological performance to interrogate a specific aspect of biology or to forecast outcome. Unfortunately, the variety of acquisition and analysis methodologies employed at different centres make ADC values non-comparable between them. This invalidates implementation in multicentre trials and limits utility of ADC as a biomarker. This article reviews the factors contributing to ADC variability in terms of data acquisition and analysis. Hardware and software considerations are discussed when implementing standardised protocols across multi-vendor platforms together with methods for quality assurance and quality control. Processes of data collection, archiving, curation, analysis, central reading and handling incidental findings are considered in the conduct of multicentre trials. Data protection and good clinical practice are essential prerequisites. Developing international consensus of procedures is critical to successful validation if ADC is to become a useful biomarker in oncology. Key Points • Standardised acquisition/analysis allows quantification of imaging biomarkers in multicentre trials. • Establishing “precision” of the measurement in the multicentre context is essential. • A repository with traceable data of known provenance promotes further research.
- Open Access
- 20 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6Part1) , 2998-3007
Development of a temperature‐controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements
Purpose: Diffusion‐weighted (DW) and dynamic contrast‐enhanced magnetic resonance imaging (MRI) are increasingly applied for the assessment of functional tissue biomarkers for diagnosis, lesion characterization, or for monitoring of treatment response. However, these techniques are vulnerable to the influence of various factors, so there is a necessity for a standardized MR quality assurance procedure utilizing a phantom to facilitate the reliable estimation of repeatability of these quantitative biomarkers arising from technical factors (e.g., B1 variation) affecting acquisition on scanners of different vendors and field strengths. The purpose of this study is to present a novel phantom designed for use in quality assurance for multicenter trials, and the associated repeatability measurements of functional and quantitative imaging protocols across different MR vendors and field strengths.Methods: A cylindrical acrylic phantom was manufactured containing 7 vials of polyvinylpyrrolidone (PVP) solutions of different concentrations, ranging from 0% (distilled water) to 25% w/w, to create a range of different MR contrast parameters. Temperature control was achieved by equilibration with ice‐water. Repeated MR imaging measurements of the phantom were performed on four clinical scanners (two at 1.5 T, two at 3.0 T; two vendors) using the same scanning protocol to assess the long‐term and short‐term repeatability. The scanning protocol consisted of DW measurements, inversion recovery (IR) T1 measurements, multiecho T2 measurement, and dynamic T1‐weighted sequence allowing multiple variable flip angle (VFA) estimation of T1 values over time. For each measurement, the corresponding calculated parameter maps were produced. On each calculated map, regions of interest (ROIs) were drawn within each vial and the median value of these voxels was assessed. For the dynamic data, the autocorrelation function and their variance were calculated; for the assessment of the repeatability, the coefficients of variation (CoV) were calculated.Results: For both field strengths across the available vendors, the apparent diffusion coefficient (ADC) at 0 °C ranged from (1.12 ± 0.01) × 10−3 mm2/s for pure water to (0.48 ± 0.02) × 10−3 mm2/s for the 25% w/w PVP concentration, presenting a minor variability between the vendors and the field strengths. T2 and IR‐T1 relaxation time results demonstrated variability between the field strengths and the vendors across the different acquisitions. Moreover, the T1 values derived from the VFA method exhibited a large variation compared with the IR‐T1 values across all the scanners for all repeated measurements, although the calculation of the standard deviation of the VFA‐T1 estimate across each ROI and the autocorrelation showed a stability of the signal for three scanners, with autocorrelation of the signal over the dynamic series revealing a periodic variation in one scanner. Finally, the ADC, the T2, and the IR‐T1 values exhibited an excellent repeatability across the scanners, whereas for the dynamic data, the CoVs were higher.Conclusions: The combination of a novel PVP phantom, with multiple compartments to give a physiologically relevant range of ADC and T1 values, together with ice‐water as a temperature‐controlled medium, allows reliable quality assurance measurements that can be used to measure agreement between MRI scanners, critical in multicenter functional and quantitative imaging studies.
- 20 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6Part1) , 2998-3007
Open AccessDevelopment of a temperature‐controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements
Purpose: Diffusion‐weighted (DW) and dynamic contrast‐enhanced magnetic resonance imaging (MRI) are increasingly applied for the assessment of functional tissue biomarkers for diagnosis, lesion characterization, or for monitoring of treatment response. However, these techniques are vulnerable to the influence of various factors, so there is a necessity for a standardized MR quality assurance procedure utilizing a phantom to facilitate the reliable estimation of repeatability of these quantitative biomarkers arising from technical factors (e.g., B1 variation) affecting acquisition on scanners of different vendors and field strengths. The purpose of this study is to present a novel phantom designed for use in quality assurance for multicenter trials, and the associated repeatability measurements of functional and quantitative imaging protocols across different MR vendors and field strengths.Methods: A cylindrical acrylic phantom was manufactured containing 7 vials of polyvinylpyrrolidone (PVP) solutions of different concentrations, ranging from 0% (distilled water) to 25% w/w, to create a range of different MR contrast parameters. Temperature control was achieved by equilibration with ice‐water. Repeated MR imaging measurements of the phantom were performed on four clinical scanners (two at 1.5 T, two at 3.0 T; two vendors) using the same scanning protocol to assess the long‐term and short‐term repeatability. The scanning protocol consisted of DW measurements, inversion recovery (IR) T1 measurements, multiecho T2 measurement, and dynamic T1‐weighted sequence allowing multiple variable flip angle (VFA) estimation of T1 values over time. For each measurement, the corresponding calculated parameter maps were produced. On each calculated map, regions of interest (ROIs) were drawn within each vial and the median value of these voxels was assessed. For the dynamic data, the autocorrelation function and their variance were calculated; for the assessment of the repeatability, the coefficients of variation (CoV) were calculated.Results: For both field strengths across the available vendors, the apparent diffusion coefficient (ADC) at 0 °C ranged from (1.12 ± 0.01) × 10−3 mm2/s for pure water to (0.48 ± 0.02) × 10−3 mm2/s for the 25% w/w PVP concentration, presenting a minor variability between the vendors and the field strengths. T2 and IR‐T1 relaxation time results demonstrated variability between the field strengths and the vendors across the different acquisitions. Moreover, the T1 values derived from the VFA method exhibited a large variation compared with the IR‐T1 values across all the scanners for all repeated measurements, although the calculation of the standard deviation of the VFA‐T1 estimate across each ROI and the autocorrelation showed a stability of the signal for three scanners, with autocorrelation of the signal over the dynamic series revealing a periodic variation in one scanner. Finally, the ADC, the T2, and the IR‐T1 values exhibited an excellent repeatability across the scanners, whereas for the dynamic data, the CoVs were higher.Conclusions: The combination of a novel PVP phantom, with multiple compartments to give a physiologically relevant range of ADC and T1 values, together with ice‐water as a temperature‐controlled medium, allows reliable quality assurance measurements that can be used to measure agreement between MRI scanners, critical in multicenter functional and quantitative imaging studies.
- 1 May 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1049) , 20140717
Development of a diffusion-weighted MRI protocol for multicentre abdominal imaging and evaluation of the effects of fasting on measurement of apparent diffusion coefficients (ADCs) in healthy liver
To assess the effect of fasting and eating on estimates of apparent diffusion coefficient (ADC) in the livers of healthy volunteers using a diffusion-weighted MRI protocol with b-values of 100, 500 and 900 s mm−2 in a multicentre study at 1.5 T. 20 volunteers were scanned using 4 clinical 1.5-T MR scanners. Volunteers were scanned after fasting for at least 4 h and after eating a meal; the scans were repeated on a subsequent day. Median ADC estimates were calculated from all pixels in three slices near the centre of the liver. Analysis of variance (ANOVA) was used to assess the difference between ADC estimates in fasted and non-fasted states and between ADC estimates on different days. ANOVA showed no difference between ADC estimates in fasted and non-fasted states (p = 0.8) nor between ADC estimates on different days (p = 0.8). The repeatability of the measurements was good, with coefficients of variation of 5.1% and 4.6% in fasted and non-fasted states, respectively. There was no significant difference in ADC estimates between fasted and non-fasted measurements, indicating that the perfusion sensitivity of ADC estimates obtained from b-values of 100, 500 and 900 s mm−2 is sufficiently low that changes in blood flow in the liver after eating are undetectable beyond the variability in the measurements. Assessment of the effect of prandial state on ADC estimates is critical, in order to determine the appropriate patient preparation for biological validation in clinical trials.
- 1 May 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1049) , 20140717
Development of a diffusion-weighted MRI protocol for multicentre abdominal imaging and evaluation of the effects of fasting on measurement of apparent diffusion coefficients (ADCs) in healthy liver
To assess the effect of fasting and eating on estimates of apparent diffusion coefficient (ADC) in the livers of healthy volunteers using a diffusion-weighted MRI protocol with b-values of 100, 500 and 900 s mm−2 in a multicentre study at 1.5 T. 20 volunteers were scanned using 4 clinical 1.5-T MR scanners. Volunteers were scanned after fasting for at least 4 h and after eating a meal; the scans were repeated on a subsequent day. Median ADC estimates were calculated from all pixels in three slices near the centre of the liver. Analysis of variance (ANOVA) was used to assess the difference between ADC estimates in fasted and non-fasted states and between ADC estimates on different days. ANOVA showed no difference between ADC estimates in fasted and non-fasted states (p = 0.8) nor between ADC estimates on different days (p = 0.8). The repeatability of the measurements was good, with coefficients of variation of 5.1% and 4.6% in fasted and non-fasted states, respectively. There was no significant difference in ADC estimates between fasted and non-fasted measurements, indicating that the perfusion sensitivity of ADC estimates obtained from b-values of 100, 500 and 900 s mm−2 is sufficiently low that changes in blood flow in the liver after eating are undetectable beyond the variability in the measurements. Assessment of the effect of prandial state on ADC estimates is critical, in order to determine the appropriate patient preparation for biological validation in clinical trials.