Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabrizio Leonforte has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    From Operational to Embodied Emissions: Insights into the LCA of Key Building Systems

    by Anna Dalla Valle, Fabrizio Leonforte, Andrea Campioli, Monica Lavagna, Claudio Del Pero, Niccolò Aste

  • Perception-Driven Discrete Color Engineering to Enhance Aesthetic Integration in BIPV

    by Fabrizio Leonforte, Claudio Del Pero, Niccolò Aste, Brando Romano, Harold Enrique Huerto-Cardenas, Alessandro Miglioli

  • Open Access

    The Role of Geometric Simplification in Building Energy Simulation: A Systematic Review with Insights on Historic Buildings

    by Zhiyuan Xin, Harold Enrique Huerto-Cardenas, Fabrizio Leonforte, Claudio Del Pero, Niccolo’ Aste

    Energy simulation software has become a widely adopted tool in both professional and academic fields, supporting tasks such as renovation evaluation, performance estimation, and energy certification. Despite its extensive use, there are still challenges in the modeling process that need further investigation, as they can affect the accuracy of the simulation results. Many of these issues are related to the geometric simplification performed during the modeling phase. In fact, energy modeling software requires a simplification process of the real building, which inevitably leads to a loss of accuracy. This issue is especially critical in historic buildings, where complex geometries increase the risk of error and require more advanced modeling expertise than new buildings. Moreover, although many previous studies have addressed the accuracy of building energy simulations, few studies have systematically addressed the role of geometric simplification in this context. The analyzed literature is not exclusively related to historic buildings but also considers new and generic constructions, as many modeling issues are common among these categories. However, historic buildings often have greater geometric complexity and therefore provide an opportunity to analyze various modeling challenges. In this regard, this research presents a systematic review of geometric model simplification strategies used in building energy simulation, studies their impact on the results, and tries to define an appropriate procedure for energy modeling to reduce the performance gap. Furthermore, the results indicate that future research is needed to develop well-documented and accurate geometric model simplification methods capable of assisting designers with their building energy simulation needs.

  • A Methodological Framework for Integrating Climate Resilience into Historical Building Rehabilitation: A Case Study in South Tyrol, Italy

    by Camille Luna Stella Blavier, Elena Maines, Harold Enrique Huerto-Cardenas, Claudio Del Pero, Fabrizio Leonforte

  • Open Access

    The Effect of Urban Morphology on Solar Potential: A Detailed Assessment of the City of Milan in Italy

    by Fabrizio Leonforte, Rajendra S. Adhikari, Niccolò Aste, Claudio Del Pero, Harold Enrique Huerto-Cardenas, Zhiyuan Xin, Ioanna Bazaki

    Solar energy plays a fundamental role in achieving decarbonization in the construction sector, and therefore, a detailed assessment of solar potential at the urban scale is a key tool in supporting this process. Within this framework, the present study focuses on the high-resolution evaluation of photovoltaic (PV) potential in urban environments, specifically targeting the city of Milan, Italy, where two representative study areas are selected. In detail, 3D city models are developed using Rhino3D 7 software, and a solar radiation analysis was performed using Ladybug components. The solar radiation received by the surfaces that comprise the roofs and facades of buildings is estimated for each floor and orientation, taking into account local climate conditions and shadows cast by surrounding buildings. To define the economic viability of PV system deployment, two threshold criteria were introduced: one concerning the size (area) of the PV system and the other the minimum annual solar radiation level that each surface receives. Based on the obtained data, it is found that approximately 28% of roof surfaces and 5% of facades meet these cost-effective thresholds for PV integration. Further analysis indicates that the balcony self-shading can be considered negligible in the high-density urban context analyzed. The results are beneficial for urban energy management, considering energy savings and investment approaches, and the possibility to transform existing buildings into zero-carbon buildings powered by renewables.


  • Open Access

    Energy Efficiency in Buildings: The Gap Between Energy Certification Methods and Real Performances

    by Niccolò Aste, Harold Enrique Huerto-Cardenas, Claudio Del Pero, Fabrizio Leonforte, Michela Buzzetti, Rajendra Singh Adhikari, Elisa Montevecchio, Camille Luna Stella Blavier

    In response to the pressing need to increase energy efficiency in buildings, new regulations are continually being introduced to enforce higher standards. The recent recast of the Energy Performance of Buildings Directive (EPBD IV) emphasizes the establishment of national performance standards, which will supposedly be based on the national Energy Performance Certificate (EPC). However, energy certifications across several European countries rely on a quasi-steady state approach, which fails to accurately represent real-performance conditions due to inherent limitations. This is more evident in buildings located in warm climates, where actual energy demands far exceed those predicted by energy certifications. To address these discrepancies, a shift towards dynamic performance assessment methods is pivotal. This research compares the heating and cooling energy demand of an office building using two approaches: the quasi-steady state, prescribed by the Italian standard, and the dynamic state. After calibrating the dynamic model, it was employed to perform a simulation incorporating more detailed user profiles and boundary conditions than those used in the quasi-steady state method. This approach allows the preservation of both reasonable accuracy and practical applicability. Finally, a sensitivity analysis of influential parameters seeks to elucidate the main causes of divergence between simulated and measured performance and to identify opportunities for improving EPC. The simulation outcomes indicate that, while the stationary model yields heating energy demand relatively aligned with the measured data, it shows substantial discrepancies (about 50%) in the cooling predictions. Moreover, the findings reinforce the inadequacy of the simpler approach and advocate for the integration of dynamic state simulation in energy performance assessment, aligning with the objectives of the recent EPBD.


  • Open Access

    A Hybrid Earth–Air Heat Exchanger with a Subsurface Water Tank: Experimental Validation in a Hot–Arid Climate

    by Safieddine Ounis, Okba Boucherit, Abdelhafid Moummi, Tallal Abdel Karim Bouzir, Djihed Berkouk, Fabrizio Leonforte, Claudio Del Pero, Mohammed M. Gomaa

    Earth–Air Heat Exchangers (EAHEs) exploit stable subsurface temperatures to pre-condition supply air. To address limitations of conventional systems in hot–arid climates, this study investigates the performance of a hybrid EAHE prototype combining a serpentine subsurface pipe with a buried water tank. Installed in a residential building in Lichana, Biskra (Algeria), the system was designed to enhance land compactness, thermal stability, and soil–water heat harvesting. Experimental monitoring was conducted across 13 intervals strategically spanning seasonal transitions and extremes and was complemented by calibrated numerical simulations. From over 30,000 data points, outlet trajectories, thermal efficiency, Coefficient of Performance (COP), and energy savings were assessed against a straight-pipe baseline. Results showed that the hybrid EAHE delivered smoother outlet profiles under moderate gradients while the baseline achieved larger instantaneous ΔT. Thermal efficiencies exceeded 90% during high-gradient episodes and averaged above 70% annually. COP values scaled with the inlet–soil gradient, ranging from 1.5 to 4.0. Cumulative recovered energy reached 80.6 kWh (3.92 kWh/day), while the heat pump electricity referred to a temperature-dependent ASHP totaled 34.59 kWh (1.40 kWh/day). Accounting for the EAHE fan yields a net saving of 25.46 kWh across the campaign, only one interval (5) was net-negative, underscoring the value of bypass/fan shut-off under weak gradients. Overall, the hybrid EAHE emerges as a footprint-efficient option for arid housing, provided operation is dynamically controlled. Future work will focus on controlling logic and soil–moisture interactions to maximize net performance.


  • Adaptive Ventilation Strategy for Climate Control in an Unheated Cathedral in Northern Italy

    by Harold Enrique Huerto-Cardenas, Niccolò Aste, Claudio Del Pero, Stefano Della Torre, Fabrizio Leonforte, Camille Luna Stella Blavier, Felice De Francesco

  • Open Access

    Appropriate Thresholds and Metrics for LEVEL(S) Key Performance Indicators (KPIs)

    by Mahsa Rastegari, Claudio Del Pero, Fabrizio Leonforte, Rajendra S. Adhikari, Niccolò Aste

    The European Union’s LEVEL(S) framework establishes a standardized methodology for evaluating and documenting the sustainability of buildings across Europe, aiming to enhance the sustainability, competitiveness, and resilience of the EU’s built environment. This study investigates the theoretical foundations and practical applications of the LEVEL(S) framework in advancing sustainable building practices. The research begins with a systematic identification of gaps in existing sustainability indicators, such as the absence of specific metrics and undefined thresholds, identified in the author’s previous work. To address these gaps, the study introduces new thresholds informed by an extensive review of the relevant literature and performance data. Additionally, the research synthesized a comprehensive Table by analyzing EU user manuals, the related academic literature, and various Green Building Rating Systems (GBRSs), thereby facilitating the extraction of pertinent standards and regulations. Collectively, these findings provide valuable resources for policymakers and stakeholders, ensuring that the recommendations are closely aligned with the LEVEL(S) framework and can be effectively applied to real-world building projects throughout Europe.


  • Open Access

    Performance Analysis of Multi-Source Heat Pumps: A Regression-Based Approach to Energy Performance Estimation

    by Reza Alijani, Fabrizio Leonforte

    The growing demand for energy-efficient heating, ventilation, and air conditioning (HVAC) systems has increased interest in multi-source heat pumps as a sustainable solution. While extensive research has been conducted on heat pump performance prediction, there is still a lack of practical tools for early-stage system evaluation. This study addresses that gap by developing regression-based models to estimate the performance of various heat pump configurations, including air-source, ground-source, and dual-source systems. A simplified performance estimation model was created, capable of delivering results with accuracy levels comparable to TRNSYS simulation outputs, making it a valuable and accessible tool for system evaluation. The analysis was conducted across nine climatic zones in Italy, considering key environmental factors such as air temperature, ground temperature, and solar irradiance. Among the tested configurations, hybrid systems like Solar-Assisted Ground-Source Heat Pumps (SAGSHP) achieved the highest performance, with SCOP values up to 4.68 in Palermo and SEER values up to 5.33 in Milan. Regression analysis confirmed strong predictive accuracy (R2 = 0.80–0.95) and statistical significance (p < 0.05), emphasizing the models’ reliability across different configurations and climatic conditions. By offering easy-to-use regression formulas, this study enables engineers and policymakers to estimate heat pump performance without relying on complex simulations.