Gudrun Abbt-Braun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gudrun Abbt-Braun has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Harald Horn
Engler-Bunte-Institut, Water Chemistry and Water Technology, Karlsruhe Institute of Technology, Engler-Bunte-Ring 9, 76131, Karlsruhe, Germany; DVGW Research Center, Water Chemistry and Water Technology, Engler-Bunte-Ring 9, 76131, Karlsruhe, Germany
2 shared publications- Aimin Li
State Key Laboratory of Water Pollution Control and Green Resource Recycling, School of Environment, Nanjing University, Nanjing, 210023, Jiangsu, China
1 shared publication Fritz H. Frimmel
Karlsruhe Institute of Technology (KIT)
1 shared publication- Harald Horn
DVGW-Research Center at the Engler-Bunte-Institut, Water Chemistry and Water Technology, Karlsruhe Institute of Technology, Engler-Bunte-Ring 9, 76131 Karlsruhe, Germany
1 shared publication Jing Jin
State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing, 210023, China
1 shared publicationKeke Xiao
Engler-Bunte-Institut, Water Chemistry and Water Technology, Karlsruhe Institute of Technology, Engler-Bunte-Ring 9, 76131, Karlsruhe, Germany; School of Environmental Science & Engineering, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, Hubei, 430074, China
1 shared publication
Latest Publications
- Open Access
Heavy Metal Removal from Aqueous Solutions Using a Customized Bipolar Membrane Electrodialysis Process
Lack of safe water availability and access to clean water cause a higher risk of infectious diseases and other diseases as well. Heavy metals (HMs) are inorganic pollutants that cause severe threats to humans, animals, and the environment. Therefore, an effective HM removal technology is urgently needed. In the present study, a customized bipolar membrane electrodialysis process was used to remove HMs from aqueous solutions. The impacts of the feed ionic strength, applied electrical potential, and the type and concentration of HMs (Cd2+, Co2+, Cr3+, Cu2+, and Ni2+) on the process performance were investigated. The results showed that feed solution pH changes occurred in four stages: it first decreased linearly before stabilizing in the acidic pH range, followed by an increase and stabilization in the basic range of the pH scale. HM speciation in the basic pH range revealed the presence of anionic HM species. The presence of HMs on anion exchange membranes confirmed the contribution of these membranes for HM removal in the base channels of the process. While no clear trend was seen in the ionic strength solution, the maximum HM removal was observed when 1.5 g/L NaCl was used. The initial HM concentration showed a linear increase in HMs removal of up to 30 mg/L. A similar trend was seen with an increase in the applied electrical potential of up to 15 V. In general, the amount of HMs removed increased in the following order: Cd2+ ˃ Ni2+ ˃ Co2+ ˃ Cu2+ ˃ Cr3+. Under some operational conditions, however, the removed amount of Cu2+, Co2+, and Ni2+ was similar. The mass balance and SEM-EDX results revealed that the removed HMs were sorbed onto the membranes. In conclusion, this process efficiently separates HMs from aqueous solutions. It showed the features of diluate pH adjustment, reduction in the overall stack electrical resistance, and contribution of anion exchange membranes in multivalent cation removal. The mechanisms involved in HMs removal were diffusion and migration from the bulk solution, followed by their sorption on both cation and anion exchange membranes.
Open AccessHeavy Metal Removal from Aqueous Solutions Using a Customized Bipolar Membrane Electrodialysis Process
Lack of safe water availability and access to clean water cause a higher risk of infectious diseases and other diseases as well. Heavy metals (HMs) are inorganic pollutants that cause severe threats to humans, animals, and the environment. Therefore, an effective HM removal technology is urgently needed. In the present study, a customized bipolar membrane electrodialysis process was used to remove HMs from aqueous solutions. The impacts of the feed ionic strength, applied electrical potential, and the type and concentration of HMs (Cd2+, Co2+, Cr3+, Cu2+, and Ni2+) on the process performance were investigated. The results showed that feed solution pH changes occurred in four stages: it first decreased linearly before stabilizing in the acidic pH range, followed by an increase and stabilization in the basic range of the pH scale. HM speciation in the basic pH range revealed the presence of anionic HM species. The presence of HMs on anion exchange membranes confirmed the contribution of these membranes for HM removal in the base channels of the process. While no clear trend was seen in the ionic strength solution, the maximum HM removal was observed when 1.5 g/L NaCl was used. The initial HM concentration showed a linear increase in HMs removal of up to 30 mg/L. A similar trend was seen with an increase in the applied electrical potential of up to 15 V. In general, the amount of HMs removed increased in the following order: Cd2+ ˃ Ni2+ ˃ Co2+ ˃ Cu2+ ˃ Cr3+. Under some operational conditions, however, the removed amount of Cu2+, Co2+, and Ni2+ was similar. The mass balance and SEM-EDX results revealed that the removed HMs were sorbed onto the membranes. In conclusion, this process efficiently separates HMs from aqueous solutions. It showed the features of diluate pH adjustment, reduction in the overall stack electrical resistance, and contribution of anion exchange membranes in multivalent cation removal. The mechanisms involved in HMs removal were diffusion and migration from the bulk solution, followed by their sorption on both cation and anion exchange membranes.
- 13 January 2022
- Published by Elsevier in Chemosphere
- Vol. 293, 133608
“Humic substances” measurement in sludge dissolved organic matter: A critical assessment of current methods
- 13 January 2022
- Published by Elsevier in Chemosphere
- Vol. 293, 133608
“Humic substances” measurement in sludge dissolved organic matter: A critical assessment of current methods
- 6 February 2018
- Published by Springer Nature in Journal of Soils and Sediments
- Vol. 18 (8) , 2668-2674
Humic matter: basis for life—a plea for humics care
- 6 February 2018
- Published by Springer Nature in Journal of Soils and Sediments
- Vol. 18 (8) , 2668-2674
Humic matter: basis for life—a plea for humics care
- 1 September 2016
- Published by Elsevier in Water Research
- Vol. 101, 262-271
Application of portable online LED UV fluorescence sensor to predict the degradation of dissolved organic matter and trace organic contaminants during ozonation
- 1 September 2016
- Published by Elsevier in Water Research
- Vol. 101, 262-271
Application of portable online LED UV fluorescence sensor to predict the degradation of dissolved organic matter and trace organic contaminants during ozonation