HZHui Zhao

Hui Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hui Zhao has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correlation between exposure (mAs) and image quality for a rapid cone‐beam CT on a ring gantry linear accelerator

    by Hui Zhao, Nicholas Nelson, Seth Streitmatter, Bradley Nordin, Thomas Martin, Ryan G. Price, Jeremy N. Kunz, Stephen Bhagroo, Y. Jessica Huang, Geoff Nelson

    Background: The adoption of HyperSight CBCT has become widespread due to its rapid CBCT scan acquisition (< 6 s) and superior image quality. Numerous studies have been conducted to evaluate HyperSight CBCT's image quality and the accuracy of treatment planning dose calculations using HyperSight CBCT. Nevertheless, for the main function of CBCT as a tool of image guided radiation therapy (IGRT), one clinically significant question remains unanswered: What is the quantitative correlation between exposure level (mAs) and desired image quality? This study aims to explore the quantitative correlation between exposure level and image quality, providing guidelines for selecting the appropriate CBCT mAs based on imaging objectives and patient size for the optimal IGRT alignment. Purpose: To investigate the correlation between HyperSight CBCT (equipped on Halcyon linear accelerator) exposure level and image quality. Methods: Nine‐series of 261 sets CBCT scans were acquired using HyperSight on the Halcyon (125 kV, 133‐971 mAs, FOV: 28.2, 36, and 53.8 cm). Three‐series were acquired with the CatPhan 604 alone, three‐series with CatPhan 604 surrounded by a 32 cm custom‐made acrylic annulus, and three series with CatPhan 604 surrounded by a 40 cm custom‐made acrylic annulus. Image quality metrics were analyzed included signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), image noise, low‐contrast visibility (LCV), uniformity index (UI), integral non‐uniformity (INU), and modulation transfer function (MTF). The correlation between mAs and image quality was evaluated. Results: The SNR and CNR for all material inserts increased with rising mAs for all scans, with a higher amplitude of increase for scans without annuli. The SNR and CNR were higher for scans without annuli. Both image noise and LCV decreased with rising mAs and were higher for scans with annuli. The UI was independent of mAs for scans of CatPhan alone and CatPhan with a small annulus, and was slightly higher for scans without annuli (∼0.1 vs ∼0.2). The INU slightly increased with rising mAs and was higher for scans without annuli. MTF was independent of mAs and with or without annuli. MTF values varied with FOV, with smaller FOV yielding better image sharpness. All parameters were FOV‐dependent except INU, and generally, the larger the FOV, the better the image quality (except spatial resolution). Conclusions: HyperSight CBCT acquisition is recommended to be performed with a maximum FOV of 53.8 cm. To meet the Rose criterion, for a 20 cm width object, CBCT should be acquired at ≥154 mAs; for a 32 cm width object, CBCT should be acquired at ≥572.6 mAs to reach a 3σ confidence level; for a 40 cm object, CBCT should be acquired at ≥572.6 mAs to reach a 3σ confidence level for all materials except polystyrene (soft‐tissue).


  • Open Access

    Comprehensive Image Quality Evaluation and Motion Phantom Studies of an Ultra-Fast (6-Second) Cone-Beam Computed Tomography Imaging System on a Ring Gantry Linear Accelerator

    by Hui Zhao, Geoff Nelson, Vikren Sarkar, Courtney Oare, Martin Szegedi, Sara St. James, Jeremy Kunz, Ryan Price, Y. Jessica Huang


  • Open Access

    Verification of surface‐guided radiation therapy (SGRT) alignment for proton breast and chest wall patients by comparison to CT‐on‐rails and kV‐2D alignment

    by Hui Zhao, Vikren Sarkar, Sara St James, Adam Paxton, Fan‐Chi Frances Su, Ryan G. Price, Christian Dial, Matthew Poppe, David Gaffney, Bill Salter

    Background: Surface‐guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited.Purpose: To assess the clinical application and alignment agreement of SGRT with CT‐on‐rails (CTOR) and kV‐2D image‐guided radiation therapy (IGRT) for breast treatment using proton therapy.Methods: Four patients receiving breast or chest wall treatment with proton therapy were the subjects of this study. Patient #1′s IGRT modalities were a combination of kV‐2D and CTOR. CTOR was the only imaging modality for patients #2 and #3, and kV‐2D was the only imaging modality for patient #4. The patients’ respiratory motions were assessed using a 2‐min surface position recorded by the SGRT system during treatment. SGRT offsets reported after IGRT shifts were recorded for each fraction of treatment. The agreement between SGRT and either kV‐2D or CTOR was evaluated.Results: The respiratory motion amplitude was ° in rotation for all patients. The mean and maximum amplitude of SGRT offsets after application of IGRT shifts were ≤(2.6 mm, 1.6°) and (6.8 mm, 4.5°) relative to kV‐2D‐based IGRT; ≤(3.0 mm, 2.6°) and (5.0 mm, 4.7°) relative to CTOR‐based IGRT without breast tissue inflammation. For patient #3, breast inflammation was observed for the last three fractions of treatment, and the maximum SGRT offsets post CTOR shifts were up to (14.0 mm, 5.2°).Conclusions: Due to the overall agreement between SGRT and IGRT within reasonable tolerance, SGRT has the potential to serve as a valuable auxiliary IGRT tool for proton breast treatment and may improve the efficiency of proton breast treatment.


  • Initial clinical evaluation of a novel combined biometric, radio-frequency identification, and surface imaging system

    by Hui Zhao, Christine Haacke, Vikren Sarkar, Adam Paxton, Y. Jessica Huang, Martin Szegedi, Ryan G. Price, Fan-Chi Frances Su, Prema Rassiah-Szegedi, Bill Salter


  • Open Access

    Importance of radiographic tumor regression during radiotherapy in squamous cell versus adenocarcinoma of the uterine cervix as assessed by MRI and cone beam CT

    by Christopher R. Weil, Fadi Haroun, Kevin Guo, Ryan Kraus, Hui Zhao, Lindsay Burt, Gita Suneja, Cristina DeCesaris, Y. Jessica Huang, David K. Gaffney

    European Journal of Gynaecological Oncology (EJGO) is an international, peer-reviewed, open access journal, which is currently indexed in SCIE, etc. It covers many aspects of gynaecologic oncology topics, including Cervical Cancer, Fallopian Tube Cancer, Breast Cancer etc.

  • A novel approach for Venezia ovoid commissioning with a comprehensive analysis of source positions in high-dose-rate brachytherapy

    by Xing Li, Jessica Huang, Robabeh Rahimi, Hui Zhao, Jeremy Kunz, Gita Suneja, Fan-Chi Su


  • Open Access

    Surface-Guided Patient Setup Versus Traditional Tattoo Markers for Radiation Therapy: Is Tattoo-Less Setup Feasible for Thorax, Abdomen and Pelvis Treatment?

    by Hui Zhao, Adam Paxton, Vikren Sarkar, Ryan G. Price, Jessica Huang, Fan-Chi Frances Su, Xing Li, Prema Rassiah, Martin Szegedi, Bill Salter

    Purpose: In this study, patient setup accuracy was compared between surface guidance and tattoo markers for radiation therapy treatment sites of the thorax, abdomen and pelvis. Methods and materials: A total of 608 setups performed on 59 patients using both surface-guided and tattoo-based patient setups were analyzed. During treatment setup, patients were aligned to room lasers using their tattoos, and then the six-degree-of-freedom (6DOF) surface-guided offsets were calculated and recorded using AlignRT system. While the patient remained in the same post-tattoo setup position, target localization imaging (radiographic or ultrasound) was performed and these image-guided shifts were recorded. Finally, surface-guided vs tattoo-based offsets were compared to the final treatment position (based on radiographic or ultrasound imaging) to evaluate the accuracy of the two setup methods. Results: The overall average offsets of tattoo-based and surface-guidance-based patient setups were comparable within 3.2 mm in three principal directions, with offsets from tattoo-based setups being slightly less. The maximum offset for tattoo setups was 2.2 cm vs. 4.3 cm for surface-guidance setups. Larger offsets (ranging from 2.0 to 4.3 cm) were observed for surface-guided setups in 14/608 setups (2.3%). For these same cases, the maximum observed tattoo-based offset was 0.7 cm. Of the cases with larger surface-guided offsets, 13/14 were for abdominal/pelvic treatment sites. Additionally, larger rotations (>3°) were recorded in 18.6% of surface-guided setups. The majority of these larger rotations were observed for abdominal and pelvic sites (~84%). Conclusions: The small average differences observed between tattoo-based and surface-guidance-based patient setups confirm the general equivalence of the two potential methods, and the feasibility of tattoo-less patient setup. However, a significant number of larger surface-guided offsets (translational and rotational) were observed, especially in the abdominal and pelvic regions. These cases should be anticipated and contingency setup methods planned for.


  • Impact of detector selection on commissioning of Leipzig surface applicators with improving immobilization in high-dose-rate brachytherapy

    by Xing Li, Fan-Chi Su, Vikren Sarkar, Hui Zhao, Sergio Ibanez, Jeremy N Kunz, Geoff Nelson, Y. Jessica Huang


  • Prevention of Radiation Therapy Treatment Deviations by a Novel Combined Biometric, Radiofrequency Identification, and Surface Imaging System

    by Hui Zhao, Adam Paxton, Vikren Sarkar, Y. Jessica Huang, Fan-Chi Frances Su, Christine Haacke, Prema Rassiah-Szegedi, Martin Szegedi, Bill Salter


  • Comparison of surface guidance and target matching for image‐guided accelerated partial breast irradiation (APBI)

    by Hui Zhao, Ned Williams, Matthew Poppe, Vikren Sarkar, Brian Wang, Prema Rassiah‐Szegedi, Y. Jessica Huang, Kristine Kokeny, David Gaffney, Bill Salter

    Purpose: We investigate the feasibility of surface guided radiation therapy (SGRT) for accelerated partial breast irradiation (APBI) by comparing it with in‐room, fan beam kV computed tomography on rails (CTOR) imaging of the targeted region. The uniqueness of our study is that all patients have multiple daily CTOR scans to compare corresponding SGRT AlignRT (VisionRT, United Kingdom) images to.Methods/materials: Twelve patients receiving APBI were enrolled in this study. Before each treatment fraction, after patients were setup on tattoos, SGRT was performed using AlignRT, and then target matching was performance using CTOR. The average and maximum difference in shifts between SGRT and CTOR were calculated and analyzed for each patient, so as the correlation between surgical cavity size and shift difference.Results: Our study showed that SGRT agreed well with CTOR for patients with small surgical cavity volume changes (<10%). There were nine patients who had a ≥5 mm maximum shift difference between SGRT and CTOR along any direction, and in two patients the difference was more than 10 mm (one patient with surgical cavity change 44.3% and one patient with 27 cc cavity volume decrease). All patients, except one, had a mean shift difference < 5 mm along any direction.Conclusion: For the patients studied here, SGRT appears to be a reasonable and potentially valuable image guidance approach for APBI for patients who experience small changes in surgical cavity volume (<10%) between CT simulation and treatment. However, there is potential for larger alignment errors (up to 11 mm) when using SGRT for patients who experience larger surgical cavity changes.