Rasim Boyacioglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rasim Boyacioglu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Dan Ma
Department of Neurosurgery Duke University Durham North Carolina USA
3 shared publications - Mark Alan Griswold
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
3 shared publications - Yong Chen
Department of Radiology Case Western Reserve University Cleveland Ohio USA
3 shared publications - Chaitra Badve
Department of Radiology University Hospitals Cleveland Medical Center Cleveland Ohio USA
2 shared publications - Debra F. McGivney
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
2 shared publications - Adonis Hijaz
University Hospitals Cleveland Medical Center, Cleveland, OH 44145, USA
1 shared publication
Latest Publications
- Open Access
- 28 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 209-217
A MR Fingerprinting Development Kit for Quantitative 3D Brain Imaging
Background: Magnetic resonance fingerprinting (MRF) is an emerging quantitative imaging technique that enables multiparametric tissue characterization, but its adoption has been hindered by the complexity of data acquisition and post‐processing. These technical and implementation challenges have limited its broader clinical deployment. Purpose: To develop a modular MRF Development Kit (MRFDK) that enables efficient sequence design, streamlined implementation, and real‐time image reconstruction. Study Type: Prospective. Population: T 1 and T 2 relaxation phantom, nine volunteers (seven males and two females), five metastatic brain cancer patients. Field Strength/Sequence: 3 T, MR Fingerprinting. Assessment: Accuracy of T 1 and T 2 quantification was estimated from phantom experiments. Manual ROIs were drawn on brain lesions and contralateral white matter for metastatic cancer patients. Statistical Tests: t ‐test, in vivo repeatability was calculated with Bland–Altman analysis on healthy volunteer scan‐rescan data, significance level p < 0.01. Results: Phantom results showed high accuracy in T 1 and T 2 assessment, with absolute percentage differences of 3% for T 1 and 5% for T 2 compared to offline MATLAB reconstruction. In vivo scans of eight healthy subjects further demonstrated excellent repeatability (bias and agreement: 0.95% ± 1.85% for T 1 ; 1.78% ± 5.08% for T 2 ). In patients, metastatic lesions showed significantly higher T 1 and T 2 values (T 1 , 1474 ms; T 2 , 61 ms) compared to normal white matter (T 1 , 913 ms; T 2 , 38 ms). With integrated B 1 correction, all T 1 and T 2 maps were available for visualization within 1 min post‐MRF scan, enabling immediate image assessment. Data Conclusion: A modular MRF development package enabling efficient 3D acquisition and rapid inline reconstruction was developed and evaluated in this study. Level of Evidence: 1. Technical Efficacy: Stage 2.
- 28 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 209-217
Open AccessA MR Fingerprinting Development Kit for Quantitative 3D Brain Imaging
Background: Magnetic resonance fingerprinting (MRF) is an emerging quantitative imaging technique that enables multiparametric tissue characterization, but its adoption has been hindered by the complexity of data acquisition and post‐processing. These technical and implementation challenges have limited its broader clinical deployment. Purpose: To develop a modular MRF Development Kit (MRFDK) that enables efficient sequence design, streamlined implementation, and real‐time image reconstruction. Study Type: Prospective. Population: T 1 and T 2 relaxation phantom, nine volunteers (seven males and two females), five metastatic brain cancer patients. Field Strength/Sequence: 3 T, MR Fingerprinting. Assessment: Accuracy of T 1 and T 2 quantification was estimated from phantom experiments. Manual ROIs were drawn on brain lesions and contralateral white matter for metastatic cancer patients. Statistical Tests: t ‐test, in vivo repeatability was calculated with Bland–Altman analysis on healthy volunteer scan‐rescan data, significance level p < 0.01. Results: Phantom results showed high accuracy in T 1 and T 2 assessment, with absolute percentage differences of 3% for T 1 and 5% for T 2 compared to offline MATLAB reconstruction. In vivo scans of eight healthy subjects further demonstrated excellent repeatability (bias and agreement: 0.95% ± 1.85% for T 1 ; 1.78% ± 5.08% for T 2 ). In patients, metastatic lesions showed significantly higher T 1 and T 2 values (T 1 , 1474 ms; T 2 , 61 ms) compared to normal white matter (T 1 , 913 ms; T 2 , 38 ms). With integrated B 1 correction, all T 1 and T 2 maps were available for visualization within 1 min post‐MRF scan, enabling immediate image assessment. Data Conclusion: A modular MRF development package enabling efficient 3D acquisition and rapid inline reconstruction was developed and evaluated in this study. Level of Evidence: 1. Technical Efficacy: Stage 2.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58, e20240104
Quantitative assessment of bladder tissue properties using magnetic resonance fingerprinting: a pilot feasibility study in healthy volunteers
Objective: To investigate the feasibility of performing magnetic resonance fingerprinting (MRF) of the bladder and quantify the T1 and T2 relaxation times of the bladder wall in healthy female volunteers, before and after voiding.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58, e20240104
Open AccessQuantitative assessment of bladder tissue properties using magnetic resonance fingerprinting: a pilot feasibility study in healthy volunteers
Objective: To investigate the feasibility of performing magnetic resonance fingerprinting (MRF) of the bladder and quantify the T1 and T2 relaxation times of the bladder wall in healthy female volunteers, before and after voiding.
- Open Access
- 9 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1600-1616
Efficient pulse sequence design framework for high‐dimensional MR fingerprinting scans using systematic error index
Purpose: For effective optimization of MR fingerprinting (MRF) pulse sequences, estimating and minimizing errors from actual scan conditions are crucial. Although virtual‐scan simulations offer an approximation to these errors, their computational demands become expensive for high‐dimensional MRF frameworks, where interactions between more than two tissue properties are considered. This complexity makes sequence optimization impractical. We introduce a new mathematical model, the systematic error index (SEI), to address the scalability challenges for high‐dimensional MRF sequence design.Methods: By eliminating the need to perform dictionary matching, the SEI model approximates quantification errors with low computational costs. The SEI model was validated in comparison with virtual‐scan simulations. The SEI model was further applied to optimize three high‐dimensional MRF sequences that quantify two to four tissue properties. The optimized scans were examined in simulations and healthy subjects.Results: The proposed SEI model closely approximated the virtual‐scan simulation outcomes while achieving hundred‐ to thousand‐times acceleration in the computational speed. In both simulation and in vivo experiments, the optimized MRF sequences yield higher measurement accuracy with fewer undersampling artifacts at shorter scan times than the heuristically designed sequences.Conclusion: We developed an efficient method for estimating real‐world errors in MRF scans with high computational efficiency. Our results illustrate that the SEI model could approximate errors both qualitatively and quantitatively. We also proved the practicality of the SEI model of optimizing sequences for high‐dimensional MRF frameworks with manageable computational power. The optimized high‐dimensional MRF scans exhibited enhanced robustness against undersampling and system imperfections with faster scan times.
- 9 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1600-1616
Open AccessEfficient pulse sequence design framework for high‐dimensional MR fingerprinting scans using systematic error index
Purpose: For effective optimization of MR fingerprinting (MRF) pulse sequences, estimating and minimizing errors from actual scan conditions are crucial. Although virtual‐scan simulations offer an approximation to these errors, their computational demands become expensive for high‐dimensional MRF frameworks, where interactions between more than two tissue properties are considered. This complexity makes sequence optimization impractical. We introduce a new mathematical model, the systematic error index (SEI), to address the scalability challenges for high‐dimensional MRF sequence design.Methods: By eliminating the need to perform dictionary matching, the SEI model approximates quantification errors with low computational costs. The SEI model was validated in comparison with virtual‐scan simulations. The SEI model was further applied to optimize three high‐dimensional MRF sequences that quantify two to four tissue properties. The optimized scans were examined in simulations and healthy subjects.Results: The proposed SEI model closely approximated the virtual‐scan simulation outcomes while achieving hundred‐ to thousand‐times acceleration in the computational speed. In both simulation and in vivo experiments, the optimized MRF sequences yield higher measurement accuracy with fewer undersampling artifacts at shorter scan times than the heuristically designed sequences.Conclusion: We developed an efficient method for estimating real‐world errors in MRF scans with high computational efficiency. Our results illustrate that the SEI model could approximate errors both qualitatively and quantitatively. We also proved the practicality of the SEI model of optimizing sequences for high‐dimensional MRF frameworks with manageable computational power. The optimized high‐dimensional MRF scans exhibited enhanced robustness against undersampling and system imperfections with faster scan times.
- Open Access
- 9 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 2074-2088
Quantifying 3D MR fingerprinting (3D‐MRF) reproducibility across subjects, sessions, and scanners automatically using MNI atlases
Purpose: Quantitative MRI techniques such as MR fingerprinting (MRF) promise more objective and comparable measurements of tissue properties at the point‐of‐care than weighted imaging. However, few direct cross‐modal comparisons of MRF's repeatability and reproducibility versus weighted acquisitions have been performed. This work proposes a novel fully automated pipeline for quantitatively comparing cross‐modal imaging performance in vivo via atlas‐based sampling.Methods: We acquire whole‐brain 3D‐MRF, turbo spin echo, and MPRAGE sequences three times each on two scanners across 10 subjects, for a total of 60 multimodal datasets. The proposed automated registration and analysis pipeline uses linear and nonlinear registration to align all qualitative and quantitative DICOM stacks to Montreal Neurological Institute (MNI) 152 space, then samples each dataset's native space through transformation inversion to compare performance within atlas regions across subjects, scanners, and repetitions.Results: Voxel values within MRF‐derived maps were found to be more repeatable (σT1 = 1.90, σT2 = 3.20) across sessions than vendor‐reconstructed MPRAGE (σT1w = 6.04) or turbo spin echo (σT2w = 5.66) images. Additionally, MRF was found to be more reproducible across scanners (σT1 = 2.21, σT2 = 3.89) than either qualitative modality (σT1w = 7.84, σT2w = 7.76). Notably, differences between repeatability and reproducibility of in vivo MRF were insignificant, unlike the weighted images.Conclusion: MRF data from many sessions and scanners can potentially be treated as a single dataset for harmonized analysis or longitudinal comparisons without the additional regularization steps needed for qualitative modalities.
- 9 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 2074-2088
Open AccessQuantifying 3D MR fingerprinting (3D‐MRF) reproducibility across subjects, sessions, and scanners automatically using MNI atlases
Purpose: Quantitative MRI techniques such as MR fingerprinting (MRF) promise more objective and comparable measurements of tissue properties at the point‐of‐care than weighted imaging. However, few direct cross‐modal comparisons of MRF's repeatability and reproducibility versus weighted acquisitions have been performed. This work proposes a novel fully automated pipeline for quantitatively comparing cross‐modal imaging performance in vivo via atlas‐based sampling.Methods: We acquire whole‐brain 3D‐MRF, turbo spin echo, and MPRAGE sequences three times each on two scanners across 10 subjects, for a total of 60 multimodal datasets. The proposed automated registration and analysis pipeline uses linear and nonlinear registration to align all qualitative and quantitative DICOM stacks to Montreal Neurological Institute (MNI) 152 space, then samples each dataset's native space through transformation inversion to compare performance within atlas regions across subjects, scanners, and repetitions.Results: Voxel values within MRF‐derived maps were found to be more repeatable (σT1 = 1.90, σT2 = 3.20) across sessions than vendor‐reconstructed MPRAGE (σT1w = 6.04) or turbo spin echo (σT2w = 5.66) images. Additionally, MRF was found to be more reproducible across scanners (σT1 = 2.21, σT2 = 3.89) than either qualitative modality (σT1w = 7.84, σT2w = 7.76). Notably, differences between repeatability and reproducibility of in vivo MRF were insignificant, unlike the weighted images.Conclusion: MRF data from many sessions and scanners can potentially be treated as a single dataset for harmonized analysis or longitudinal comparisons without the additional regularization steps needed for qualitative modalities.
- 12 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2084-2094
3D magnetic resonance fingerprinting with quadratic RF phase
Purpose: To implement 3D magnetic resonance fingerprinting (MRF) with quadratic RF phase (qRF‐MRF) for simultaneous quantification of T1, T2, ΔB0, and .Methods: 3D MRF data with effective undersampling factor of 3 in the slice direction were acquired with quadratic RF phase patterns for T1, T2, and sensitivity. Quadratic RF phase encodes the off‐resonance by modulating the on‐resonance frequency linearly in time. Transition to 3D brings practical limitations for reconstruction and dictionary matching because of increased data and dictionary sizes. Randomized singular value decomposition (rSVD)‐based compression in time and reduction in dictionary size with a quadratic interpolation method are combined to be able to process prohibitively large data sets in feasible reconstruction and matching times.Results: Accuracy of 3D qRF‐MRF maps in various resolutions and orientations are compared to 3D fast imaging with steady‐state precession (FISP) for T1 and T2 contrast and to 2D qRF‐MRF for contrast and ΔB0. The precision of 3D qRF‐MRF was 1.5‐2 times higher than routine clinical scans. 3D qRF‐MRF ΔB0 maps were further processed to highlight the susceptibility contrast.Conclusion: Natively co‐registered 3D whole brain T1, T2, , ΔB0, and QSM maps can be acquired in as short as 5 min with 3D qRF‐MRF.
- 12 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2084-2094
3D magnetic resonance fingerprinting with quadratic RF phase
Purpose: To implement 3D magnetic resonance fingerprinting (MRF) with quadratic RF phase (qRF‐MRF) for simultaneous quantification of T1, T2, ΔB0, and .Methods: 3D MRF data with effective undersampling factor of 3 in the slice direction were acquired with quadratic RF phase patterns for T1, T2, and sensitivity. Quadratic RF phase encodes the off‐resonance by modulating the on‐resonance frequency linearly in time. Transition to 3D brings practical limitations for reconstruction and dictionary matching because of increased data and dictionary sizes. Randomized singular value decomposition (rSVD)‐based compression in time and reduction in dictionary size with a quadratic interpolation method are combined to be able to process prohibitively large data sets in feasible reconstruction and matching times.Results: Accuracy of 3D qRF‐MRF maps in various resolutions and orientations are compared to 3D fast imaging with steady‐state precession (FISP) for T1 and T2 contrast and to 2D qRF‐MRF for contrast and ΔB0. The precision of 3D qRF‐MRF was 1.5‐2 times higher than routine clinical scans. 3D qRF‐MRF ΔB0 maps were further processed to highlight the susceptibility contrast.Conclusion: Natively co‐registered 3D whole brain T1, T2, , ΔB0, and QSM maps can be acquired in as short as 5 min with 3D qRF‐MRF.
- 14 June 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1981-1986
Multiband echo‐shifted echo planar imaging
Purpose To propose the technique multiband echo-shifted (MESH) echo planar imaging (EPI), which combines the principles of echo-shifted acquisition for two-dimensional multislice EPI, with both in-plane and multiband acceleration by means of partial parallel imaging techniques. Methods MESH EPI is suitable for functional MRI (fMRI) in situations where there is sufficient time to insert an additional EPI readout in the dead time between slice selection and the standard EPI readout. In such situations, MESH EPI can further accelerate data acquisition compared with standard multiband techniques. The method is particularly well suited for low static magnetic field strengths and lower spatial resolutions. We compared MESH with multiband and standard EPI with temporal signal-to-noise ratio (tSNR) measurements and resting state fMRI data. Results Results obtained at 1.5 T from healthy subjects revealed that the additional gradient switching did not additionally affect time course SNR over and above the reduction inherent to multiband imaging. Functional results were qualitatively similar between methods. MESH was not affected by the tSNR reduction and echo shifting gradients. The MESH data were acquired at a factor 2 or 3 faster than corresponding multiband acquisitions for echo shift factors of 1 and 2, respectively. Conclusion MESH can offer further acceleration of image acquisition for fMRI at no loss in sensitivity. Magn Reson Med 77:1981–1986, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- 14 June 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1981-1986
Multiband echo‐shifted echo planar imaging
Purpose To propose the technique multiband echo-shifted (MESH) echo planar imaging (EPI), which combines the principles of echo-shifted acquisition for two-dimensional multislice EPI, with both in-plane and multiband acceleration by means of partial parallel imaging techniques. Methods MESH EPI is suitable for functional MRI (fMRI) in situations where there is sufficient time to insert an additional EPI readout in the dead time between slice selection and the standard EPI readout. In such situations, MESH EPI can further accelerate data acquisition compared with standard multiband techniques. The method is particularly well suited for low static magnetic field strengths and lower spatial resolutions. We compared MESH with multiband and standard EPI with temporal signal-to-noise ratio (tSNR) measurements and resting state fMRI data. Results Results obtained at 1.5 T from healthy subjects revealed that the additional gradient switching did not additionally affect time course SNR over and above the reduction inherent to multiband imaging. Functional results were qualitatively similar between methods. MESH was not affected by the tSNR reduction and echo shifting gradients. The MESH data were acquired at a factor 2 or 3 faster than corresponding multiband acquisitions for echo shift factors of 1 and 2, respectively. Conclusion MESH can offer further acceleration of image acquisition for fMRI at no loss in sensitivity. Magn Reson Med 77:1981–1986, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Open Access
- 1 January 2013
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 7, 156
An Investigation of RSN Frequency Spectra Using Ultra-Fast Generalized Inverse Imaging
With the advancements in MRI hardware, pulse sequences and reconstruction techniques, many low TR sequences are becoming more and more popular within the fMRI community. In this study, we have investigated the spectral characteristics of resting state networks (RSNs) with a newly introduced ultra fast fMRI technique, called Generalized Inverse Imaging (GIN). The high temporal resolution of GIN (TR=50 ms) enables to sample cardiac signals without aliasing into a separate frequency band from the BOLD fluctuations. Respiration related signal changes are, on the other hand, removed from the data without the need for external physiological recordings. We have observed that the variance over the subjects is higher than the variance over RSNs.
- 1 January 2013
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 7, 156
Open AccessAn Investigation of RSN Frequency Spectra Using Ultra-Fast Generalized Inverse Imaging
With the advancements in MRI hardware, pulse sequences and reconstruction techniques, many low TR sequences are becoming more and more popular within the fMRI community. In this study, we have investigated the spectral characteristics of resting state networks (RSNs) with a newly introduced ultra fast fMRI technique, called Generalized Inverse Imaging (GIN). The high temporal resolution of GIN (TR=50 ms) enables to sample cardiac signals without aliasing into a separate frequency band from the BOLD fluctuations. Respiration related signal changes are, on the other hand, removed from the data without the need for external physiological recordings. We have observed that the variance over the subjects is higher than the variance over RSNs.