Xiang-Sheng Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiang-Sheng Xiao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Shi-Yuan Liu
5 shared publicationsChengzhou Li
Department of Radiology, The Affiliated Changzheng Hospital, Shanghai No.2 Military Medical University, Shanghai , China
4 shared publicationsShiyuan Liu
Department of Radiology, The Affiliated Changzheng Hospital, Shanghai No.2 Military Medical University, Shanghai , China
4 shared publicationsChenshi Zhang
Department of Radiology, The Affiliated Changzheng Hospital, Shanghai No.2 Military Medical University, Shanghai , China
3 shared publications- Shenjiang Li
Department of Imageology, Changzheng Hospital, The Second Military Medical University, Shanghai 200003, P.R.China
3 shared publications Huimin Li
2 shared publications
Latest Publications
- 17 November 2015
- Vol. 95 (43) , 3481-3
[Screening, dignosis and follow-up in lung cancer in early stage].
- 17 November 2015
- Vol. 95 (43) , 3481-3
[Screening, dignosis and follow-up in lung cancer in early stage].
- 20 October 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (10) , 1060-1064
Multi-detector CT features of benign and malignant pulmonary focal ground-glass opacity nodules: a binary logistic regression analysis
- 20 October 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (10) , 1060-1064
Multi-detector CT features of benign and malignant pulmonary focal ground-glass opacity nodules: a binary logistic regression analysis
- 20 June 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (6) , 625-629
Histopathologic features of rim enhancement MRI for breast infiltrating ductal carcinoma
- 20 June 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (6) , 625-629
Histopathologic features of rim enhancement MRI for breast infiltrating ductal carcinoma
- 20 December 2009
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 29 (12) , 1440-1441
Fractionated brachytherapy accelerates absorption of intratumoral hemorrhage in intracranial germ cell tumors
- 20 December 2009
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 29 (12) , 1440-1441
Fractionated brachytherapy accelerates absorption of intratumoral hemorrhage in intracranial germ cell tumors
- 14 August 2009
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 28 (8) , 979-983
Functional and molecular MR imaging in evaluating outcomes of tumor therapy
- 14 August 2009
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 28 (8) , 979-983
Functional and molecular MR imaging in evaluating outcomes of tumor therapy
- 20 May 2009
- Vol. 12 (5)
[Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size.].
The solitary pulmonary nodules (SPNs) is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI) and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.
- 20 May 2009
- Vol. 12 (5)
[Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size.].
The solitary pulmonary nodules (SPNs) is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI) and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.
- 30 April 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 70 (1) , 41-48
Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI—Initial results
- 30 April 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 70 (1) , 41-48
Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI—Initial results
- 20 February 2008
- Vol. 11 (1)
[Correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size.].
The solitary pulmonary nodules (SPNs ) is one of the most common findings on chest radiographs. It becomes possible to provide more accurately quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs ) with multi-slice spiral computed tomography (MSCT). The aim of this study is to evaluate the correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size.
- 20 February 2008
- Vol. 11 (1)
[Correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size.].
The solitary pulmonary nodules (SPNs ) is one of the most common findings on chest radiographs. It becomes possible to provide more accurately quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs ) with multi-slice spiral computed tomography (MSCT). The aim of this study is to evaluate the correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size.
- 25 December 2007
- Vol. 87 (48) , 3418-20
[Study of pulmonary parenchyma MRI with flow sensitive alternating inversion recovery].
To evaluate the feasibility of pulmonary parenchyma perfusion imaging with flow sensitive alternating inversion recovery (FAIR), which is noninvasive and doesn't necessitate injection of contrast agents. A total of 20 healthy volunteers were undergone SSFSE-FAIR imaging. Two coronal perfusion-weighted MR images were acquired, one being the posterior coronal slice, and the other being the middle slice parallel to the right pulmonary artery. The relative pulmonary blood flow (rPBF) values of bilateral lungs were calculated respectively and right to left rPBF ratio (R/L) was also evaluated. (1) The rPBF of the right lung in the posterior coronal slice was 87 +/- 24, not significantly different from that of the left lung (87 +/- 27, P > 0.05) with the R/L of 1.01 +/- 0.04. However, the rPBF of the right lung in the middle coronal slice was 41 +/- 15, significantly lower than that of the left lung (74 +/- 25, P < 0.05) with the R/L of 0.55 +/- 0.05. (2) There were significant differences in the rPBF of the homolateral lung on different slices (both P < 0.05). The rPBF values on the posterior slice of the right and left lungs were both significantly higher than those on the middle slice. Pulmonary perfusion with FAIR is feasible, but the perfusion of right and left lung may be different on certain slice due to spin saturation effect. FAIR is also sensitive to reflect perfusion heterogeneity due to gravity effect.
- 25 December 2007
- Vol. 87 (48) , 3418-20
[Study of pulmonary parenchyma MRI with flow sensitive alternating inversion recovery].
To evaluate the feasibility of pulmonary parenchyma perfusion imaging with flow sensitive alternating inversion recovery (FAIR), which is noninvasive and doesn't necessitate injection of contrast agents. A total of 20 healthy volunteers were undergone SSFSE-FAIR imaging. Two coronal perfusion-weighted MR images were acquired, one being the posterior coronal slice, and the other being the middle slice parallel to the right pulmonary artery. The relative pulmonary blood flow (rPBF) values of bilateral lungs were calculated respectively and right to left rPBF ratio (R/L) was also evaluated. (1) The rPBF of the right lung in the posterior coronal slice was 87 +/- 24, not significantly different from that of the left lung (87 +/- 27, P > 0.05) with the R/L of 1.01 +/- 0.04. However, the rPBF of the right lung in the middle coronal slice was 41 +/- 15, significantly lower than that of the left lung (74 +/- 25, P < 0.05) with the R/L of 0.55 +/- 0.05. (2) There were significant differences in the rPBF of the homolateral lung on different slices (both P < 0.05). The rPBF values on the posterior slice of the right and left lungs were both significantly higher than those on the middle slice. Pulmonary perfusion with FAIR is feasible, but the perfusion of right and left lung may be different on certain slice due to spin saturation effect. FAIR is also sensitive to reflect perfusion heterogeneity due to gravity effect.
- 13 March 2007
- Vol. 87 (10) , 673-8
[Folate-poly-L-lysine-Gd-DTPA as MR contrast agent for tumor imaging via folate receptor-targeted delivery].
To study folate-conjugated Gd-DTPA-Poly-L-Lysine (folate-PL-Gd-DTPA) as MR targeting agent to tumor cells via folate receptor, to evaluate feasibility and effectiveness by observing MR signal variations and imaging feature of pulmonary tumor xenografts in nude mice using this contrast material. (1) Using Poly-L-Lysine (PL) as linker, after PL was tethered with caDTPA, GdCl(3) was added to label DTPA-PL, then PL-Gd-DTPA was conjugated to folate, a specific MR contrast agent, was thus prepared. (2) Using high performance liquid chromatography (HPLC) to evaluate the conjugate purity, and the ICP-AES to test Gd(3+) concentration, while the activity evaluated by competitive folate receptor binding with folic acid. (3) Folate-PL-Gd-DTPA as specific contrast agents (study group, n = 6) and Gd-DTPA as non-specific contrast agents (control group, n = 4) was injected respectively into caudal vein of the nude mice which was pulmonary tumor xenografts as experimental model in the study. MRI was performed with plain scans, enhanced scans at 30 minutes, 3 hours, 6 hours, 14 hours, 24 hours, 38 hours, 48 hours, 62 hours and 72 hours after the success of injection. Signal intensities of tumors and muscles were measured. (1) folate-PL-Gd-DTPA was successfully synthesized with high affinity to folate receptor and high concentration of Gd(3+) (56 Gd(3+)/folate). (2) folate-PL-Gd-DTPA had an excellent tumor selectivity in pulmonary tumor xenografts in the animal model. After injection, the tumor signal intensity in the study group was significantly higher than that observed before injection; An average intensity increase of 125.4% was observed from pre-contrast to post-contrast images of the tumor, which was observed at 24 - 48 hours after injection; The muscle signal intensity at any time-point after injection showed no statistically difference with that observed before injection. In control group, the tumor signal intensity showed statistically difference with that observed before injection at 0.5 hour and 3 hours, the biggest difference appeared at 0.5 hour; The muscle signal intensity at 0.5 hour time-point showed statistically difference with that observed before injection. Folate-PL-Gd-DTPA could be combined to tumor cells appetencially via folate receptor and significantly targeted to tumor cells with rich folate receptors for MR imaging.
- 13 March 2007
- Vol. 87 (10) , 673-8
[Folate-poly-L-lysine-Gd-DTPA as MR contrast agent for tumor imaging via folate receptor-targeted delivery].
To study folate-conjugated Gd-DTPA-Poly-L-Lysine (folate-PL-Gd-DTPA) as MR targeting agent to tumor cells via folate receptor, to evaluate feasibility and effectiveness by observing MR signal variations and imaging feature of pulmonary tumor xenografts in nude mice using this contrast material. (1) Using Poly-L-Lysine (PL) as linker, after PL was tethered with caDTPA, GdCl(3) was added to label DTPA-PL, then PL-Gd-DTPA was conjugated to folate, a specific MR contrast agent, was thus prepared. (2) Using high performance liquid chromatography (HPLC) to evaluate the conjugate purity, and the ICP-AES to test Gd(3+) concentration, while the activity evaluated by competitive folate receptor binding with folic acid. (3) Folate-PL-Gd-DTPA as specific contrast agents (study group, n = 6) and Gd-DTPA as non-specific contrast agents (control group, n = 4) was injected respectively into caudal vein of the nude mice which was pulmonary tumor xenografts as experimental model in the study. MRI was performed with plain scans, enhanced scans at 30 minutes, 3 hours, 6 hours, 14 hours, 24 hours, 38 hours, 48 hours, 62 hours and 72 hours after the success of injection. Signal intensities of tumors and muscles were measured. (1) folate-PL-Gd-DTPA was successfully synthesized with high affinity to folate receptor and high concentration of Gd(3+) (56 Gd(3+)/folate). (2) folate-PL-Gd-DTPA had an excellent tumor selectivity in pulmonary tumor xenografts in the animal model. After injection, the tumor signal intensity in the study group was significantly higher than that observed before injection; An average intensity increase of 125.4% was observed from pre-contrast to post-contrast images of the tumor, which was observed at 24 - 48 hours after injection; The muscle signal intensity at any time-point after injection showed no statistically difference with that observed before injection. In control group, the tumor signal intensity showed statistically difference with that observed before injection at 0.5 hour and 3 hours, the biggest difference appeared at 0.5 hour; The muscle signal intensity at 0.5 hour time-point showed statistically difference with that observed before injection. Folate-PL-Gd-DTPA could be combined to tumor cells appetencially via folate receptor and significantly targeted to tumor cells with rich folate receptors for MR imaging.