René Machts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
René Machts has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jens Haueisen
Institute of Biomedical Engineering and Informatics, TU Ilmenau, Ilmenau, Germany
5 shared publications - Alexander Hunold
Institute of Biomedical Engineering and Informatics, TU Ilmenau, Ilmenau, Germany
3 shared publications Alexander Hunold
Institute of Biomedical Engineering and Informatics, Technische Universitaet Ilmenau, Ilmenau, Germany
2 shared publicationsCarsten Leu
Technische Universität Ilmenau
2 shared publicationsChristian Drebenstedt
Technische Universität Ilmenau
2 shared publications- M. Stubenrauch2 shared publications
Latest Publications
- Open Access
- 23 November 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-14
Head phantoms for bioelectromagnetic applications: a material study
Background: Assessments of source reconstruction procedures in electroencephalography and computations of transcranial electrical stimulation profiles require verification and validation with the help of ground truth configurations as implemented by physical head phantoms. For these phantoms, synthetic materials are needed, which are mechanically and electrochemically stable and possess conductivity values similar to the modeled human head tissues. Three-compartment head models comprise a scalp layer with a conductivity range of 0.137 S/m to 2.1 S/m, a skull layer with conductivity values between 0.066 S/m and 0.00275 S/m, and an intracranial volume with an often-used average conductivity value of 0.33 S/m. To establish a realistically shaped physical head phantom with a well-defined volume conduction configuration, we here characterize the electrical conductivity of synthetic materials for modeling head compartments. We analyzed agarose hydrogel, gypsum, and sodium chloride (NaCl) solution as surrogate materials for scalp, skull, and intracranial volume. We measured the impedance of all materials when immersed in NaCl solution using a four-electrode setup. The measured impedance values were used to calculate the electrical conductivity values of each material. Further, the conductivities in the longitudinal and transverse directions of reed sticks immersed in NaCl solution were measured to test their suitability for mimicking the anisotropic conductivity of white matter tracts. Results: We obtained conductivities of 0.314 S/m, 0.30 S/m, 0.311 S/m (2%, 3%, 4% agarose), 0.0425 S/m and 0.0017 S/m (gypsum with and without NaCl in the compound), and 0.332 S/m (0.17% NaCl solution). These values are within the range of the conductivity values used for EEG and TES modeling. The reed sticks showed anisotropic conductivity with a ratio of 1:2.8. Conclusion: We conclude that agarose, gypsum, and NaCl solution can serve as stable representations of the three main conductivity compartments of the head, i.e., scalp, skull, and intracranial volume. An anisotropic conductivity structure such as a fiber track in white matter can be modeled using tailored reed sticks inside a volume conductor.
- 23 November 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-14
Open AccessHead phantoms for bioelectromagnetic applications: a material study
Background: Assessments of source reconstruction procedures in electroencephalography and computations of transcranial electrical stimulation profiles require verification and validation with the help of ground truth configurations as implemented by physical head phantoms. For these phantoms, synthetic materials are needed, which are mechanically and electrochemically stable and possess conductivity values similar to the modeled human head tissues. Three-compartment head models comprise a scalp layer with a conductivity range of 0.137 S/m to 2.1 S/m, a skull layer with conductivity values between 0.066 S/m and 0.00275 S/m, and an intracranial volume with an often-used average conductivity value of 0.33 S/m. To establish a realistically shaped physical head phantom with a well-defined volume conduction configuration, we here characterize the electrical conductivity of synthetic materials for modeling head compartments. We analyzed agarose hydrogel, gypsum, and sodium chloride (NaCl) solution as surrogate materials for scalp, skull, and intracranial volume. We measured the impedance of all materials when immersed in NaCl solution using a four-electrode setup. The measured impedance values were used to calculate the electrical conductivity values of each material. Further, the conductivities in the longitudinal and transverse directions of reed sticks immersed in NaCl solution were measured to test their suitability for mimicking the anisotropic conductivity of white matter tracts. Results: We obtained conductivities of 0.314 S/m, 0.30 S/m, 0.311 S/m (2%, 3%, 4% agarose), 0.0425 S/m and 0.0017 S/m (gypsum with and without NaCl in the compound), and 0.332 S/m (0.17% NaCl solution). These values are within the range of the conductivity values used for EEG and TES modeling. The reed sticks showed anisotropic conductivity with a ratio of 1:2.8. Conclusion: We conclude that agarose, gypsum, and NaCl solution can serve as stable representations of the three main conductivity compartments of the head, i.e., scalp, skull, and intracranial volume. An anisotropic conductivity structure such as a fiber track in white matter can be modeled using tailored reed sticks inside a volume conductor.
- 31 October 2019
- Published by Springer Nature
- p. 763-772
Experimental Application of Lightning Currents to a Human Head Phantom
- 31 October 2019
- Published by Springer Nature
- p. 763-772
Experimental Application of Lightning Currents to a Human Head Phantom
- Open Access
- 26 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0223133
Measurement and analysis of partial lightning currents in a head phantom
Direct lightning strikes to the human head can lead to various effects, ranging from burnings to death. The biological and physical mechanisms of a direct lightning strike in the human head are not well understood. The aim of this paper is to design an experimental setup to measure the spatial and temporal current distribution during a direct lightning strike to physical head phantoms to establish normative values for personal lightning protection equipment design and testing. We created head phantoms made of agarose, replicating the geometric and dielectric properties of scalp, skull, and intracranial volume. The bases of the three compartments were galvanically contacted via copper electrodes to measure the current per compartment. We used pulse generators to apply aperiodic voltage and current signals that modelled lightning components. Our experiments indicated that the scalp compartment was exposed to the current with a fraction of 80–90%. The brain and skull compartments were exposed between 6–13% and 3–6% of the total measured current respectively. In case of a flashover, most of the current (98–99%) flowed through the discharge channel. Unlike previous theoretical estimates and measurements in technical setups, we observed considerably longer times for the flashover to build up. In our experiments, the time to build up a fully formed flashover varied from approximately 30–700 μs. The observed current patterns in cases without and with flashover provided information on regions of possible damage in the human head. Consequently, we identified the phenomenon of a flashover as a potential mechanism for humans to survive a lightning strike. Our measured current distributions and amplitudes formed the base for normative values, which can be used in later experimental investigations regarding the possibilities of individual lightning protection equipment for humans.
- 26 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0223133
Open AccessMeasurement and analysis of partial lightning currents in a head phantom
Direct lightning strikes to the human head can lead to various effects, ranging from burnings to death. The biological and physical mechanisms of a direct lightning strike in the human head are not well understood. The aim of this paper is to design an experimental setup to measure the spatial and temporal current distribution during a direct lightning strike to physical head phantoms to establish normative values for personal lightning protection equipment design and testing. We created head phantoms made of agarose, replicating the geometric and dielectric properties of scalp, skull, and intracranial volume. The bases of the three compartments were galvanically contacted via copper electrodes to measure the current per compartment. We used pulse generators to apply aperiodic voltage and current signals that modelled lightning components. Our experiments indicated that the scalp compartment was exposed to the current with a fraction of 80–90%. The brain and skull compartments were exposed between 6–13% and 3–6% of the total measured current respectively. In case of a flashover, most of the current (98–99%) flowed through the discharge channel. Unlike previous theoretical estimates and measurements in technical setups, we observed considerably longer times for the flashover to build up. In our experiments, the time to build up a fully formed flashover varied from approximately 30–700 μs. The observed current patterns in cases without and with flashover provided information on regions of possible damage in the human head. Consequently, we identified the phenomenon of a flashover as a potential mechanism for humans to survive a lightning strike. Our measured current distributions and amplitudes formed the base for normative values, which can be used in later experimental investigations regarding the possibilities of individual lightning protection equipment for humans.
- Open Access
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 85-88
The effect of dipole housing and feeding wires in physical phantoms for EEG
Current dipoles are well established models in the localization of neuronal activity to electroencephalography (EEG) data. In physical phantoms, current dipoles can be used as signal sources. Current dipoles are often powered by constant current sources connected via twisted pair wires mostly consisting of copper. The poles are typically formed by platinum wires. These wires as well as the dipole housing might disturb the electric potential distributions in physical phantom measurements. We aimed to quantify this distortion by comparing simulation setups with and without the wires and the housing. The electric potential distributions were simulated using finite element method (FEM). We chose a homogenous volume conductor surrounding the dipoles, which was 100 times larger than the size of the dipoles. We calculated the difference of the electric potential at the surface of the volume conductor between the simulations with and without the connecting wires and the housing. Comparing simulations neglecting all connecting wires and the housing rod to simulations considering them, the electric potential at the surface of the volume conductor differed on average by 2.85 %. Both platinum and twisted pair copper wires had a smaller effect on the electric potentials with a maximum average change of 6.38 ppm. Consequently, source localization of measurements in physical head phantoms should consider these rods in the forward model.
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 85-88
Open AccessThe effect of dipole housing and feeding wires in physical phantoms for EEG
Current dipoles are well established models in the localization of neuronal activity to electroencephalography (EEG) data. In physical phantoms, current dipoles can be used as signal sources. Current dipoles are often powered by constant current sources connected via twisted pair wires mostly consisting of copper. The poles are typically formed by platinum wires. These wires as well as the dipole housing might disturb the electric potential distributions in physical phantom measurements. We aimed to quantify this distortion by comparing simulation setups with and without the wires and the housing. The electric potential distributions were simulated using finite element method (FEM). We chose a homogenous volume conductor surrounding the dipoles, which was 100 times larger than the size of the dipoles. We calculated the difference of the electric potential at the surface of the volume conductor between the simulations with and without the connecting wires and the housing. Comparing simulations neglecting all connecting wires and the housing rod to simulations considering them, the electric potential at the surface of the volume conductor differed on average by 2.85 %. Both platinum and twisted pair copper wires had a smaller effect on the electric potentials with a maximum average change of 6.38 ppm. Consequently, source localization of measurements in physical head phantoms should consider these rods in the forward model.
- 7 May 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (3) , 953-964
Sensitivity studies and optimization of arrangements of optically pumped magnetometers in simulated magnetoencephalography
Purpose: The purpose of this paper is to present a simulation study using a model of a new optically pumped magnetometer sensor for application in the field of magnetoencephalography. The effects of sensor distance and orientation on the measurement information and the sensitivity to neuronal sources are investigated. Further, this paper uses a combinatorial optimization approach for sensor placement to measure spontaneous activity in the region of the occipital cortex. Design/methodology/approach: This paper studies the effects of sensor distance and orientation on sensitivity to cortical sources and measurement information. A three-compartment model of the head, using the boundary element method, is applied. For sensor setup optimization, a combinatorial optimization scheme is developed. Findings: The sensor distance to sources considerably affects the sensitivity and the retrieved information. A specific arrangement of four sensors for measuring spontaneous activity over the occipital part of the head is optimized by effectively avoiding position conflicts. Research limitations/implications: Individual head models, as well as more detailed noise and signal models, will increase the significance for specific-use cases in future studies. Originality/value: Effects of sensor distance and orientation are specifically evaluated for a new optically pumped magnetometer. A discrete optimization scheme for sensor optimization is introduced. The presented methodology is applicable for other sensor characterization and optimization problems. The findings contribute significantly to the development of new sensors.
- 7 May 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (3) , 953-964
Sensitivity studies and optimization of arrangements of optically pumped magnetometers in simulated magnetoencephalography
Purpose: The purpose of this paper is to present a simulation study using a model of a new optically pumped magnetometer sensor for application in the field of magnetoencephalography. The effects of sensor distance and orientation on the measurement information and the sensitivity to neuronal sources are investigated. Further, this paper uses a combinatorial optimization approach for sensor placement to measure spontaneous activity in the region of the occipital cortex. Design/methodology/approach: This paper studies the effects of sensor distance and orientation on sensitivity to cortical sources and measurement information. A three-compartment model of the head, using the boundary element method, is applied. For sensor setup optimization, a combinatorial optimization scheme is developed. Findings: The sensor distance to sources considerably affects the sensitivity and the retrieved information. A specific arrangement of four sensors for measuring spontaneous activity over the occipital part of the head is optimized by effectively avoiding position conflicts. Research limitations/implications: Individual head models, as well as more detailed noise and signal models, will increase the significance for specific-use cases in future studies. Originality/value: Effects of sensor distance and orientation are specifically evaluated for a new optically pumped magnetometer. A discrete optimization scheme for sensor optimization is introduced. The presented methodology is applicable for other sensor characterization and optimization problems. The findings contribute significantly to the development of new sensors.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Energy harvesting for active implants: powering a ruminal pH-monitoring system
Energy harvesting is a feasible method to prolong service life of implanted devices. We present a thermal energy harvesting approach for a ruminal pH-monitoring probe in cattle. Thermoelectric generators utilize the temperature gradient between the probe and the ruminal fluid during water intake. The in vivo experiment yielded a maximum electric power of 32 μW.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Energy harvesting for active implants: powering a ruminal pH-monitoring system
Energy harvesting is a feasible method to prolong service life of implanted devices. We present a thermal energy harvesting approach for a ruminal pH-monitoring probe in cattle. Thermoelectric generators utilize the temperature gradient between the probe and the ruminal fluid during water intake. The in vivo experiment yielded a maximum electric power of 32 μW.
- 1 January 2015
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 60 (s1) , s35-s46
Track C. Nano- and Physico-Chemical Systems
- 1 January 2015
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 60 (s1) , s35-s46
Track C. Nano- and Physico-Chemical Systems