Ivan O. Misiruk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ivan O. Misiruk has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Anton V. Taran
Kharkiv Institute of Physics and Technology
5 shared publications - Igor E. Garkusha
Kharkiv Institute of Physics and Technology
5 shared publications - Svitlana Romaniuk
National Centre for Nuclear Research
3 shared publications A. V. Taran
National Science Center "Kharkiv Institute of Physics and Technology" (NSC KIPT), Institute of Plasma Physics, 1 Akademicheskaya Str., Kharkiv, 61108, Ukraine
2 shared publicationsA.M. Tarasov
Kharkiv Institute of Physics and Technology
2 shared publicationsKateryna Diedkova
Sumy State Univ, 2 Rimsky Korsakov Str, UA-40007 Sumy, Ukraine
2 shared publications
Latest Publications
- 14 April 2026
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
SURFACE MODIFICATION BY ELECTROLYTIC-PLASMA POLISHING AND OXIDATION
The article examines the possibility of finishing treatment of deposited PVD films by using electrolytic-plasma polishing (EPP) or electrochemical methods. The modification results were assessed using light optical and scanning electron microscopy. The primary objective of the experimental work was to determine the conditions for eliminating the droplet phase on the surface of the deposited films. The plasma-electrolytic oxidation (PEO) method was also used as a qualitatively new step in improving the hardening of materials, combining plasma and electrochemical mechanisms for the formation of an oxide layer.
- 14 April 2026
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
SURFACE MODIFICATION BY ELECTROLYTIC-PLASMA POLISHING AND OXIDATION
The article examines the possibility of finishing treatment of deposited PVD films by using electrolytic-plasma polishing (EPP) or electrochemical methods. The modification results were assessed using light optical and scanning electron microscopy. The primary objective of the experimental work was to determine the conditions for eliminating the droplet phase on the surface of the deposited films. The plasma-electrolytic oxidation (PEO) method was also used as a qualitatively new step in improving the hardening of materials, combining plasma and electrochemical mechanisms for the formation of an oxide layer.
- 13 October 2025
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
STRUCTURE AND PHASE COMPOSITION OF Mo-N COATINGS PRODUCED BY CATHODIC ARC PVD AT VARIOUS NITROGEN PRESSURE
Mo-N coatings deposited at various nitrogen partial pressures ranging from 2∙10–3 to 1∙10–2 Torr have been investigated. The structure and chemical composition of the coatings were investigated by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Also, the structure of the coatings was analyzed by Raman spectroscopy. The microhardness of the coatings varied from 2000 to 2400 HV. Samples deposited at lower nitrogen pressures (2∙10–3 to 7∙10–3 Torr) exhibit weaker Raman responses, suggesting a lower degree of nitridation and possibly reduced structural disorder. The Raman data indicate that elevated nitrogen pressure during deposition fosters the formation of highly disordered, potentially amorphous or nanocrystalline Mo-N phases.
- 13 October 2025
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
STRUCTURE AND PHASE COMPOSITION OF Mo-N COATINGS PRODUCED BY CATHODIC ARC PVD AT VARIOUS NITROGEN PRESSURE
Mo-N coatings deposited at various nitrogen partial pressures ranging from 2∙10–3 to 1∙10–2 Torr have been investigated. The structure and chemical composition of the coatings were investigated by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Also, the structure of the coatings was analyzed by Raman spectroscopy. The microhardness of the coatings varied from 2000 to 2400 HV. Samples deposited at lower nitrogen pressures (2∙10–3 to 7∙10–3 Torr) exhibit weaker Raman responses, suggesting a lower degree of nitridation and possibly reduced structural disorder. The Raman data indicate that elevated nitrogen pressure during deposition fosters the formation of highly disordered, potentially amorphous or nanocrystalline Mo-N phases.
- Open Access
- 26 September 2022
- Published by Elsevier in Ceramics International
- Vol. 49 (3) , 4099-4108
Development of hydrophilic NbCuSi(N) &TiAlNb(N) coatings as a new strategy for medical implants modification
- 26 September 2022
- Published by Elsevier in Ceramics International
- Vol. 49 (3) , 4099-4108
Open AccessDevelopment of hydrophilic NbCuSi(N) &TiAlNb(N) coatings as a new strategy for medical implants modification
- Open Access
- 1 January 2021
- Published by Begell House Inc. Publishers in Plasma Medicine
- Vol. 11 (1) , 47-55
Application of Nd-Fe-B Permanent Magnets with Ion-Plasma ZrO2 Coating in Orthodontics
The use of braces for correcting the position of single teeth in some cases seems to be impractical, since this may lead to a violation of the position of adjacent teeth used as a support for such correction. An alternative way to displace single teeth into a normal position is to use an apparatus with permanent Nd-Fe-B magnets, which allows localizing the impact of force and the required aesthetic and functional result with fewer side effects, as well as reducing the cost of treatment. The structure, phase composition of zirconium oxide films on Nd-Fe-B magnets have been investigated by means of scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and X-ray fluorescent analysis (XRF). The influence of the ZrO2 coating in terms of its barrier properties for corrosion in quasi-physiological 0.9 NaCl solution has been studied. Clinical case of the treatment of malocclusion by using orthodontic appliances with permanent magnets is discussed.
- 1 January 2021
- Published by Begell House Inc. Publishers in Plasma Medicine
- Vol. 11 (1) , 47-55
Open AccessApplication of Nd-Fe-B Permanent Magnets with Ion-Plasma ZrO2 Coating in Orthodontics
The use of braces for correcting the position of single teeth in some cases seems to be impractical, since this may lead to a violation of the position of adjacent teeth used as a support for such correction. An alternative way to displace single teeth into a normal position is to use an apparatus with permanent Nd-Fe-B magnets, which allows localizing the impact of force and the required aesthetic and functional result with fewer side effects, as well as reducing the cost of treatment. The structure, phase composition of zirconium oxide films on Nd-Fe-B magnets have been investigated by means of scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and X-ray fluorescent analysis (XRF). The influence of the ZrO2 coating in terms of its barrier properties for corrosion in quasi-physiological 0.9 NaCl solution has been studied. Clinical case of the treatment of malocclusion by using orthodontic appliances with permanent magnets is discussed.
- 1 January 2020
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
- No. 6,p. 123-126
EFFECT OF DEPOSITION PARAMETERS ON MICROSTRUCTURE AND TRIBOLOGICAL PROPERTIES OF HARD CA-PVD MULTI-COMPONENT TiAlCrN AND TiAlCrCN COATINGS
Multicomponent TiAlCrN and TiAlCrCN coatings were deposited using vacuum arc evaporation technique on AISI 430 stainless steel. The influence of working gas pressure, C/N ratio, bias voltage on the structure and tribomechanical properties of the obtained coatings has been studied. The surface morphology, chemical compound of the coatings obtained under the various conditions has been analyzed by SEM with EDX, XRD, and XRF analysis. The dry wear pad-on-disc tests against 100Cr6 counterbody at 20 N load have been carried out. It was established that Vickers micro-hardness was varied from 26 to 41 GPa depending on deposition parameters.
- 1 January 2020
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
- No. 6,p. 123-126
EFFECT OF DEPOSITION PARAMETERS ON MICROSTRUCTURE AND TRIBOLOGICAL PROPERTIES OF HARD CA-PVD MULTI-COMPONENT TiAlCrN AND TiAlCrCN COATINGS
Multicomponent TiAlCrN and TiAlCrCN coatings were deposited using vacuum arc evaporation technique on AISI 430 stainless steel. The influence of working gas pressure, C/N ratio, bias voltage on the structure and tribomechanical properties of the obtained coatings has been studied. The surface morphology, chemical compound of the coatings obtained under the various conditions has been analyzed by SEM with EDX, XRD, and XRF analysis. The dry wear pad-on-disc tests against 100Cr6 counterbody at 20 N load have been carried out. It was established that Vickers micro-hardness was varied from 26 to 41 GPa depending on deposition parameters.
- 1 January 2020
- Published by Begell House Inc. Publishers in High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes
- Vol. 24 (1) , 9-20
ZrO2/ZrN MULTILAYERS ON BARE SINTERED NdFeB MAGNETS BY ION-PLASMA DEPOSITION WITH PULSED BIASING
Surface modification with nanocrystalline ZrO2/ZrN multilayers was performed on bare sintered NdFeB permanent magnets to improve their corrosion properties. The multilayers were deposited by ion-plasma vacuum-arc evaporation technique with curvilinear magnetic filter reducing amount of macro-particles emitted from cathode spots and using pulsed biasing mode for elimination of micro-arcs formation. The structure, chemical and phase compositions have been investigated by means of X-ray diffraction (XRD), scanning electron microscope (SEM) with energy-dispersive X-ray analysis (EDX) and X-ray fluorescence (XRF) methods. Mechanical and tribological properties were evaluated using a ball-on-disc method, Vickers microhardness and nanoindentation tests, respectively. The influence of the obtained coatings in terms of their barrier properties for corrosion in a quasi-physiological 0.9% NaCl solution has been studied. The coating had a thickness of 10 μm and achieved hardness of up to 26-30 GPa. The proposed technology, in particular, would be prospective for application of buffer multilayered coatings on NdFeB magnets used as repelling devices in orthodontics.
- 1 January 2020
- Published by Begell House Inc. Publishers in High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes
- Vol. 24 (1) , 9-20
ZrO2/ZrN MULTILAYERS ON BARE SINTERED NdFeB MAGNETS BY ION-PLASMA DEPOSITION WITH PULSED BIASING
Surface modification with nanocrystalline ZrO2/ZrN multilayers was performed on bare sintered NdFeB permanent magnets to improve their corrosion properties. The multilayers were deposited by ion-plasma vacuum-arc evaporation technique with curvilinear magnetic filter reducing amount of macro-particles emitted from cathode spots and using pulsed biasing mode for elimination of micro-arcs formation. The structure, chemical and phase compositions have been investigated by means of X-ray diffraction (XRD), scanning electron microscope (SEM) with energy-dispersive X-ray analysis (EDX) and X-ray fluorescence (XRF) methods. Mechanical and tribological properties were evaluated using a ball-on-disc method, Vickers microhardness and nanoindentation tests, respectively. The influence of the obtained coatings in terms of their barrier properties for corrosion in a quasi-physiological 0.9% NaCl solution has been studied. The coating had a thickness of 10 μm and achieved hardness of up to 26-30 GPa. The proposed technology, in particular, would be prospective for application of buffer multilayered coatings on NdFeB magnets used as repelling devices in orthodontics.
- Open Access
- 30 April 2019
- Published by Dewspublication in Nanotechnology Perceptions
- Vol. 15 (1) , 13-20
Nanostructured ZrO2 ceramic PVD coatings on Nd-Fe-B permanent magnets
- 30 April 2019
- Published by Dewspublication in Nanotechnology Perceptions
- Vol. 15 (1) , 13-20
Open AccessNanostructured ZrO2 ceramic PVD coatings on Nd-Fe-B permanent magnets
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 128-131
Data acquisition system based on Arduino platform for Langmuir probe plasma measurements
A simple data acquisition system based on Arduino Nano platform is designed. Bluetooth wireless protocol has been used for data transmission. Android OS application for data visualization and recording is developed. The system has been successfully applied for acquiring data from Langmuir probe measurements in the non-self-sustained discharge with a hollow anode.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 128-131
Data acquisition system based on Arduino platform for Langmuir probe plasma measurements
A simple data acquisition system based on Arduino Nano platform is designed. Bluetooth wireless protocol has been used for data transmission. Android OS application for data visualization and recording is developed. The system has been successfully applied for acquiring data from Langmuir probe measurements in the non-self-sustained discharge with a hollow anode.
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 61 (2) , 195-199
Non-self-sustained discharge with hollow anode for plasma-based surface treatment
The paper discusses plasma methods for surface modification using the non-self-sustained glow discharge with a hollow anode. This discharge is characterised by low voltage and high values of electron and ion currents. It can be easily excited in vacuum-arc installations that are widely used for coatings deposition. It is shown that such type of discharge may be effectively used for ion pumping, film deposition, ion etching, diffusion saturation of metallic materials, fusion and brazing of metals, and for combined application of above mentioned technologies in a single vacuum cycle.
- 1 June 2016
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 61 (2) , 195-199
Open AccessNon-self-sustained discharge with hollow anode for plasma-based surface treatment
The paper discusses plasma methods for surface modification using the non-self-sustained glow discharge with a hollow anode. This discharge is characterised by low voltage and high values of electron and ion currents. It can be easily excited in vacuum-arc installations that are widely used for coatings deposition. It is shown that such type of discharge may be effectively used for ion pumping, film deposition, ion etching, diffusion saturation of metallic materials, fusion and brazing of metals, and for combined application of above mentioned technologies in a single vacuum cycle.