Nadia Malek Taher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nadia Malek Taher has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- AlFulwah A. AlOtaibi
Department of Restorative Sciences, College of Dentistry, King Saud University, Riyadh 11362, Saudi Arabia
1 shared publication - Haifa Abdulrahman Alkhamis
College of Dentistry, KSU, P.O. Box 1897, Riyadh 11441, Saudi Arabia
1 shared publication Maha Ad'Dahash
1 shared publicationNasrien Z. Ateyah
1 shared publication- Sarah Mesha’l Dowaidi
College of Dentistry, KSU, P.O. Box 1290, Riyadh 11431, Saudi Arabia
1 shared publication Sheikha Hamed Al-Aujan
1 shared publication
Latest Publications
- Open Access
Repair Bond Strength of Two Shadeless Resin Composites Bonded to Various CAD-CAM Substrates with Different Surface Treatments
This study compared the repair bond strength values of two single-shade composite resins bonded to different computer-aided design and computer-aided manufacturing (CAD-CAM) substrates with different surface treatments. A total of 80 slice-shaped specimens were fabricated using two CAD-CAM materials: Lava Ultimate and VitaEnamic. The substrates were thermocycled and then, based on the surface treatment, each substrate material was subdivided into four groups: the air abrasion group (APA), the hydrofluoric-acid-etched group (HF) and two silicon carbide ground groups (SiCr). All of the groups received silane followed by Single Bond Universal Adhesive application prior to being repaired with a resin composite of a smaller disc shape. All the specimens were thermocycled prior to shear bond strength testing and subsequent failure analyses. Statistical analyses were conducted, and the level of statistical significance was set at 0.05. A comparison of the mean values showed a highly statistically significant difference among the eight groups. The highest value of mean shear bond strength was associated with Lava Ultimate substrates repaired using the Charisma Diamond ONE composite after APA surface treatment (36.7 ± 1.99). Meanwhile, the lowest value was recorded for the Vita Enamic group repaired using the OMNICHROMA composite after SiCr surface treatment (17.8 ± 1.6). The failure analysis revealed that cohesive failure in the substrate was the most predominant. Within the limitations of this study, Charisma Diamond ONE showed better bond strength values compared to Omnichroma. Meanwhile, APA is recommended for improved bond strength in repairs of Lava Ultimate restorations.
Open AccessRepair Bond Strength of Two Shadeless Resin Composites Bonded to Various CAD-CAM Substrates with Different Surface Treatments
This study compared the repair bond strength values of two single-shade composite resins bonded to different computer-aided design and computer-aided manufacturing (CAD-CAM) substrates with different surface treatments. A total of 80 slice-shaped specimens were fabricated using two CAD-CAM materials: Lava Ultimate and VitaEnamic. The substrates were thermocycled and then, based on the surface treatment, each substrate material was subdivided into four groups: the air abrasion group (APA), the hydrofluoric-acid-etched group (HF) and two silicon carbide ground groups (SiCr). All of the groups received silane followed by Single Bond Universal Adhesive application prior to being repaired with a resin composite of a smaller disc shape. All the specimens were thermocycled prior to shear bond strength testing and subsequent failure analyses. Statistical analyses were conducted, and the level of statistical significance was set at 0.05. A comparison of the mean values showed a highly statistically significant difference among the eight groups. The highest value of mean shear bond strength was associated with Lava Ultimate substrates repaired using the Charisma Diamond ONE composite after APA surface treatment (36.7 ± 1.99). Meanwhile, the lowest value was recorded for the Vita Enamic group repaired using the OMNICHROMA composite after SiCr surface treatment (17.8 ± 1.6). The failure analysis revealed that cohesive failure in the substrate was the most predominant. Within the limitations of this study, Charisma Diamond ONE showed better bond strength values compared to Omnichroma. Meanwhile, APA is recommended for improved bond strength in repairs of Lava Ultimate restorations.
- 1 April 2013
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 34 (4) , 408-414
Atomic force microscopy and tridimensional topography analysis of human enamel after resinous infiltration and storage in water
OBJECTIVE: To evaluate the effect of water storage on surface roughness (Ra) of human enamel after treatment with resin infiltrant and fissure sealant, by utilizing atomic force microscopy (AFM) and microtomography. METHODS: This study was conducted after registration and ethical approval clarification at the College of Dentistry Research Center, King Saud University, Riyadh, Kingdom of Saudi Arabia between January 2011 and August 2011. Thirty enamel surface specimens were prepared from caries-free human premolar teeth. Specimens were divided into 3 groups: Group I, was the control; Group II, a resin infiltrant (Icon) was applied on the enamel surfaces; and Group III, the teeth were treated with fissure sealant (SealRite). All specimens were stored in distilled water for 6 months and then, subjected to AFM Veeco CP11 1.2 analysis. A few specimens were scanned by skyscan-1072-x-ray microtomography. The Ra mean readings were recorded and statistical analysis was performed with the Statistical Package for Social Sciences Version 16 at the significance level of p<0.05. RESULTS: No significant differences in the mean Ra were recorded among the 3 groups, (Group I = 0.21+/-0.057), (Group II = 0.23+/-0.075), and (Group III = 0.20+/-0.039) at p=0.747. The AFM images of enamel surface show thin and inhomogeneous Icon resin in Group II, meanwhile, the SealRite in Group III showed a homogeneous layer in all specimens. The microtomography supported the findings of the AFM images. CONCLUSION: The persistence of the SealRite in all specimens revealed its low solubility in water and its protective effect on enamel surface.
- 1 April 2013
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 34 (4) , 408-414
Atomic force microscopy and tridimensional topography analysis of human enamel after resinous infiltration and storage in water
OBJECTIVE: To evaluate the effect of water storage on surface roughness (Ra) of human enamel after treatment with resin infiltrant and fissure sealant, by utilizing atomic force microscopy (AFM) and microtomography. METHODS: This study was conducted after registration and ethical approval clarification at the College of Dentistry Research Center, King Saud University, Riyadh, Kingdom of Saudi Arabia between January 2011 and August 2011. Thirty enamel surface specimens were prepared from caries-free human premolar teeth. Specimens were divided into 3 groups: Group I, was the control; Group II, a resin infiltrant (Icon) was applied on the enamel surfaces; and Group III, the teeth were treated with fissure sealant (SealRite). All specimens were stored in distilled water for 6 months and then, subjected to AFM Veeco CP11 1.2 analysis. A few specimens were scanned by skyscan-1072-x-ray microtomography. The Ra mean readings were recorded and statistical analysis was performed with the Statistical Package for Social Sciences Version 16 at the significance level of p<0.05. RESULTS: No significant differences in the mean Ra were recorded among the 3 groups, (Group I = 0.21+/-0.057), (Group II = 0.23+/-0.075), and (Group III = 0.20+/-0.039) at p=0.747. The AFM images of enamel surface show thin and inhomogeneous Icon resin in Group II, meanwhile, the SealRite in Group III showed a homogeneous layer in all specimens. The microtomography supported the findings of the AFM images. CONCLUSION: The persistence of the SealRite in all specimens revealed its low solubility in water and its protective effect on enamel surface.
- Open Access
- 1 April 2012
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 24 (2) , 79-84
The influence of resin infiltration system on enamel microhardness and surface roughness: An in vitro study
To investigate the effect of a resin infiltrant on the surface microhardness and roughness of healthy enamel and, as a subsidiary aim, to compare it with a fissure sealant. Twenty freshly extracted premolars were used. Sound enamel surfaces were treated with a resin infiltrant (Icon) or fissure sealant (Seal-Rite). The average roughness (R a, μm) of the specimens was measured with a profilometer (Surtronic 10 Tylor Hobson). Surface hardness was determined by utilizing Vicker's surface hardness (VHN) with a Micromet II Microhardness tester. Each specimen acted as its own control. Data were analyzed with 2-way analysis of variance (ANOVA), and mean values were compared with independent t-test. All analyses were performed with the SPSS program version 16 (USA). Differences with a P-value of ⩽0.05 were considered statistically significant. Comparison of enamel surfaces before and after application of resin infiltrant revealed no significant differences in surface hardness; however, enamel surfaces treated by infiltrant showed significantly higher VHN (244.0 ± 79.8) values than those treated with fissure sealant (37.5 ± 14.2). Surface roughness did not differ before and after application of either material to sound enamel. Enamel surfaces treated with fissure sealant (5.3 ± 1.4) were significantly smoother than those treated with infiltrant (6.9 ± 2.0). Within the limitations of the study, the results showed that enamels treated with the resin infiltrant showed approximately the same microhardness and surface roughness as sound enamel, indicating that this material might be suitable for the treatment of enamel subsurface lesions.
- 1 April 2012
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 24 (2) , 79-84
Open AccessThe influence of resin infiltration system on enamel microhardness and surface roughness: An in vitro study
To investigate the effect of a resin infiltrant on the surface microhardness and roughness of healthy enamel and, as a subsidiary aim, to compare it with a fissure sealant. Twenty freshly extracted premolars were used. Sound enamel surfaces were treated with a resin infiltrant (Icon) or fissure sealant (Seal-Rite). The average roughness (R a, μm) of the specimens was measured with a profilometer (Surtronic 10 Tylor Hobson). Surface hardness was determined by utilizing Vicker's surface hardness (VHN) with a Micromet II Microhardness tester. Each specimen acted as its own control. Data were analyzed with 2-way analysis of variance (ANOVA), and mean values were compared with independent t-test. All analyses were performed with the SPSS program version 16 (USA). Differences with a P-value of ⩽0.05 were considered statistically significant. Comparison of enamel surfaces before and after application of resin infiltrant revealed no significant differences in surface hardness; however, enamel surfaces treated by infiltrant showed significantly higher VHN (244.0 ± 79.8) values than those treated with fissure sealant (37.5 ± 14.2). Surface roughness did not differ before and after application of either material to sound enamel. Enamel surfaces treated with fissure sealant (5.3 ± 1.4) were significantly smoother than those treated with infiltrant (6.9 ± 2.0). Within the limitations of the study, the results showed that enamels treated with the resin infiltrant showed approximately the same microhardness and surface roughness as sound enamel, indicating that this material might be suitable for the treatment of enamel subsurface lesions.
- 1 February 2008
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 9 (2) , 57-64
The Effect of Different Light-Curing Methods on Temperature Changes of Dual Polymerizing Agents Cemented to Human Dentin
Aim: This in vitro study aims to measure the temperature changes of resin luting cements cemented to human dentin when using different light curing systems for photo-activitation. Methods and Materials: The three different types of light-curing units (LCUs) used for photoactivation were quartz-tungsten halogen (QTH), light emitting diode (LED), and plasma arc (PAC). Two types of dual cure resin cements were used [Variolink II™ (VL) and Choice™ (CH)]. Feltik Z250™ composite resin material was used to prepare composite discs. Thirty human dentin specimens were prepared for each resin luting cement (ten for each light source). A total of 60 specimens were fabricated. Resin cement was applied on a dentin bridge and covered with the prepared composite disc where specimens were fabricated. Temperature change was recorded with a digital thermometer. Results: The lowest temperature was recorded when VL and CH were photo-activated with the PAC unit. The PAC unit produced significantly lower recorded temperatures than the LED and QTH units. No significant difference appeared between QTH and LED units in terms of recorded temperature. Results: The lowest temperature was recorded when VL and CH were photo-activated with the PAC unit. The PAC unit produced significantly lower recorded temperatures than the LED and QTH units. No significant difference appeared between QTH and LED units in terms of recorded temperature. Conclusion: The PAC unit produced significantly lower temperature changes compared to QTH and LED curing units. The risk for temperature rise should be taken into consideration during photo-polymerization of adhesive resins with LED or QTH in deep cavities when dentin thickness is 0.5 mm. Citation: Taher NM, Al-Khairallah Y, Al-Aujan SH, Ad'dahash M. The Effect of Different Light-Curing Methods on Temperature Changes of Dual Polymerizing Agents Cemented to Human Dentin. J Contemp Dent Pract 2008 February;(9)2:057-064.
- 1 February 2008
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 9 (2) , 57-64
The Effect of Different Light-Curing Methods on Temperature Changes of Dual Polymerizing Agents Cemented to Human Dentin
Aim: This in vitro study aims to measure the temperature changes of resin luting cements cemented to human dentin when using different light curing systems for photo-activitation. Methods and Materials: The three different types of light-curing units (LCUs) used for photoactivation were quartz-tungsten halogen (QTH), light emitting diode (LED), and plasma arc (PAC). Two types of dual cure resin cements were used [Variolink II™ (VL) and Choice™ (CH)]. Feltik Z250™ composite resin material was used to prepare composite discs. Thirty human dentin specimens were prepared for each resin luting cement (ten for each light source). A total of 60 specimens were fabricated. Resin cement was applied on a dentin bridge and covered with the prepared composite disc where specimens were fabricated. Temperature change was recorded with a digital thermometer. Results: The lowest temperature was recorded when VL and CH were photo-activated with the PAC unit. The PAC unit produced significantly lower recorded temperatures than the LED and QTH units. No significant difference appeared between QTH and LED units in terms of recorded temperature. Results: The lowest temperature was recorded when VL and CH were photo-activated with the PAC unit. The PAC unit produced significantly lower recorded temperatures than the LED and QTH units. No significant difference appeared between QTH and LED units in terms of recorded temperature. Conclusion: The PAC unit produced significantly lower temperature changes compared to QTH and LED curing units. The risk for temperature rise should be taken into consideration during photo-polymerization of adhesive resins with LED or QTH in deep cavities when dentin thickness is 0.5 mm. Citation: Taher NM, Al-Khairallah Y, Al-Aujan SH, Ad'dahash M. The Effect of Different Light-Curing Methods on Temperature Changes of Dual Polymerizing Agents Cemented to Human Dentin. J Contemp Dent Pract 2008 February;(9)2:057-064.
- 1 February 2007
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 8 (2) , 25-34
Shear Bond Strength of Resin Modified Glass Ionomer Cement Bonded to Different Tooth-Colored Restorative Materials
Aim: The aim of this study was to determine in vitro the shear bond strength (MPa) and the type of bond failure when resin-modified glass ionomer cement (RMGIC) was bonded with different tooth-colored restorative materials. Methods and Materials: The RMGIC tested was Fuji II LC (FL) and the tooth-colored restorative materials used were composite resin Point-4 (P4), Compomer Dyract AP (DY), and Ormocere Admira (AD). A total number of 60 FL specimens were prepared using Teflon molds. The specimens were divided into six equal groups. Each group of ten specimens was bonded to a tested tooth-colored restorative material as follows: Group I - etched FL bonded to P4; Group II - non-etched FL bonded to P4; Group III - etched FL bonded to DY; Group IV - non-etched FL bonded to DY; Group V - etched FL bonded to AD; and Group VI - non-etched FL bonded to AD. The specimens were stored in distilled water at 37°C for 24 hours. The shear bond strength was measured in a universal testing machine, and the fractured surfaces were examined under a stereomicroscope. Results: The results of the shear bond strength indicated the lowest mean value (14.46 MPa) was in Group III, and this was significantly different from the values of other groups (p<0.05). However, Groups V and VI recorded the highest mean values (24.5 MPa and 28.39 MPa) which were significantly different (p<0.05) when compared to other groups. Groups I, II, and IV showed no significant difference with mean values of 20.06, 19.99, and 20.1 MPa which were significantly different from other groups (p<0.05). Conclusion: AD showed the highest shear bond strength to RMGIC. All groups demonstrated a cohesive failure in FL except for Group IV where a cohesive failure in DY was recorded. AD showed good shear bond strength when laminated with FL. Citation: Taher NM, Ateyah NZ. Shear Bond Strength of Resin Modified Glass Ionomer Cement Bonded to Different Tooth-Colored Restorative Materials. J Contemp Dent Pract 2007 February;(8)2:025-034.
- 1 February 2007
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 8 (2) , 25-34
Shear Bond Strength of Resin Modified Glass Ionomer Cement Bonded to Different Tooth-Colored Restorative Materials
Aim: The aim of this study was to determine in vitro the shear bond strength (MPa) and the type of bond failure when resin-modified glass ionomer cement (RMGIC) was bonded with different tooth-colored restorative materials. Methods and Materials: The RMGIC tested was Fuji II LC (FL) and the tooth-colored restorative materials used were composite resin Point-4 (P4), Compomer Dyract AP (DY), and Ormocere Admira (AD). A total number of 60 FL specimens were prepared using Teflon molds. The specimens were divided into six equal groups. Each group of ten specimens was bonded to a tested tooth-colored restorative material as follows: Group I - etched FL bonded to P4; Group II - non-etched FL bonded to P4; Group III - etched FL bonded to DY; Group IV - non-etched FL bonded to DY; Group V - etched FL bonded to AD; and Group VI - non-etched FL bonded to AD. The specimens were stored in distilled water at 37°C for 24 hours. The shear bond strength was measured in a universal testing machine, and the fractured surfaces were examined under a stereomicroscope. Results: The results of the shear bond strength indicated the lowest mean value (14.46 MPa) was in Group III, and this was significantly different from the values of other groups (p<0.05). However, Groups V and VI recorded the highest mean values (24.5 MPa and 28.39 MPa) which were significantly different (p<0.05) when compared to other groups. Groups I, II, and IV showed no significant difference with mean values of 20.06, 19.99, and 20.1 MPa which were significantly different from other groups (p<0.05). Conclusion: AD showed the highest shear bond strength to RMGIC. All groups demonstrated a cohesive failure in FL except for Group IV where a cohesive failure in DY was recorded. AD showed good shear bond strength when laminated with FL. Citation: Taher NM, Ateyah NZ. Shear Bond Strength of Resin Modified Glass Ionomer Cement Bonded to Different Tooth-Colored Restorative Materials. J Contemp Dent Pract 2007 February;(8)2:025-034.
- 1 May 2005
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 6 (2) , 18-26
The Effect of Bleaching Agents on the Surface Hardness of Tooth Colored Restorative Materials
Aim of the Study: The aim of this study was to evaluate the effect of at-home (Opalesence/Dr. kit 15%, Ultradent, Products, Inc. South Jordan, UT, USA) and in-office (Superoxol 35%, Sultan Chemists, Inc., Englewood, NJ, USA) bleaching on the surface hardness of the following tooth colored restorative materials: composite resin, Point-4 (P4), Kerr Corporation, Orange, CA, USA; ormocer, Admira (AD),VOCO, Germany; compomer Dyract AP (DY), Dentsply DeTrey GmbH, Germany; and resin modified glass ionomer cement, Fuji II LC (FL), GC Corporation, Japan. Methodology: Sixty specimens were prepared; 15 specimens of each material (each group n = 5, control after 15 days, at-home and in-office). All specimens were stored in distilled water at room temperature for 24 hrs before testing. A universal testing machine (Micromet 2100 series micro hardness testers) was used for testing Vicker's surface hardness for the three groups for every tested material. All results were statistically analyzed with one way analysis of variance (ANOVA), Post hoc Tukey HSD tests (P<0.05), and percentage changes for Tukey. Results: All the tested materials showed an increase in Vicker's surface hardness between base line (24 hrs) and the control group after 15 days storage in distilled water except DY which showed a decrease in surface hardness. All tested materials showed a decrease in surface hardness from control group after 15 days and both at-home and in-office bleaching agents except DY which showed increased values. Significance: At-home as well as in-office bleaching agents have a softening effect on some tooth colored restorative material, and the patient must be aware before using them. Citation: Taher NM. The Effect of Bleaching Agents on the Surface Hardness of Tooth Colored Restorative Materials. J Contemp Dent Pract 2005 May;(6)2:018-026.
- 1 May 2005
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 6 (2) , 18-26
The Effect of Bleaching Agents on the Surface Hardness of Tooth Colored Restorative Materials
Aim of the Study: The aim of this study was to evaluate the effect of at-home (Opalesence/Dr. kit 15%, Ultradent, Products, Inc. South Jordan, UT, USA) and in-office (Superoxol 35%, Sultan Chemists, Inc., Englewood, NJ, USA) bleaching on the surface hardness of the following tooth colored restorative materials: composite resin, Point-4 (P4), Kerr Corporation, Orange, CA, USA; ormocer, Admira (AD),VOCO, Germany; compomer Dyract AP (DY), Dentsply DeTrey GmbH, Germany; and resin modified glass ionomer cement, Fuji II LC (FL), GC Corporation, Japan. Methodology: Sixty specimens were prepared; 15 specimens of each material (each group n = 5, control after 15 days, at-home and in-office). All specimens were stored in distilled water at room temperature for 24 hrs before testing. A universal testing machine (Micromet 2100 series micro hardness testers) was used for testing Vicker's surface hardness for the three groups for every tested material. All results were statistically analyzed with one way analysis of variance (ANOVA), Post hoc Tukey HSD tests (P<0.05), and percentage changes for Tukey. Results: All the tested materials showed an increase in Vicker's surface hardness between base line (24 hrs) and the control group after 15 days storage in distilled water except DY which showed a decrease in surface hardness. All tested materials showed a decrease in surface hardness from control group after 15 days and both at-home and in-office bleaching agents except DY which showed increased values. Significance: At-home as well as in-office bleaching agents have a softening effect on some tooth colored restorative material, and the patient must be aware before using them. Citation: Taher NM. The Effect of Bleaching Agents on the Surface Hardness of Tooth Colored Restorative Materials. J Contemp Dent Pract 2005 May;(6)2:018-026.