Csilla Pesznyák
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Csilla Pesznyák has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Csaba Polgár
Sugárterápiás Központ, Országos Onkológiai Intézet, Budapest, Hungary.
5 shared publications - Tibor Major
Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary
5 shared publications András Bajcsay
1 shared publication- András Herein
National Institute of Oncology, Radiotherapy Centre , Budapest , Hungary
1 shared publication András Szilágyi
1 shared publicationBalázs Almády
1 shared publication
Latest Publications
- Open Access
- 12 April 2025
- Published by Elsevier in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
- Vol. 904, 503869
A study of radiation workers: Dosimetry, chromosomal aberrations, and cancer risk
- 12 April 2025
- Published by Elsevier in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
- Vol. 904, 503869
Open AccessA study of radiation workers: Dosimetry, chromosomal aberrations, and cancer risk
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 148
[P171] Quality control measurements for head and neck cancer patients with SHANE Phantom
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 148
[P171] Quality control measurements for head and neck cancer patients with SHANE Phantom
- 15 June 2016
- Vol. 60 (4) , 305-311
[Dosimetric comparison of different techniques for external beam accelerated partial breast irradiation].
The aim of this article is to evaluate and compare four different radiotherapy techniques of accelerated partial breast irradiation (APBI) considering planning quality, dosimetric and practical aspects. The investigated techniques are three dimensional conformal radiotherapy (3D-CRT), "step and shoot" (SS) and "sliding window" (SW) intensity-modulated radiotherapy, intensity-modulated arc therapy (RA). CT scans of 10 patients previously treated with APBI were selected for the study. Surgical clips were placed on the borders of the tumour bed during breast conserving surgery. Target volume (PTV) was defined as enlarged CTV, which was created from the tumour bed through volume expansion using individual margins. Planning objectives were set up according to the international recommendations. Non-coplanar fields were used only for the 3D-CRT plans. For each plan homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. There was no significant difference in the coverage of the target volume by the prescribed dose between the techniques. SW plans were significantly more homogeneous (HI=0.033) than the 3D-CRT (HI=0.057) and the RA (HI=0.073) plans. The homogeneity of the SS technique (HI=0.053) did not differ significantly compared to others. The conformity of the 3D-CRT technique was significantly worse (CN=0.62) than that of SS (CN=0.85), SW (CN=0.85) and RA (CN=0.86) plans. There was a significant difference between RA (29.4%) and 3D-CRT (44.1%) and SW (35.6%) plans in the V50% of the ipsilateral breast. Mean V10% of the ipsilateral lung in 3D-CRT (10.1%) plans was significantly lower than in SS (34.3%), SW (34.3%) and RA (35.3%) plans. 3D-CRT technique provided the best heart protection. The shortest treatment times were achieved with RA technique. Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all the aspects, we recommend the sliding window IMRT technique for accelerated partial breast irradiation.
- 15 June 2016
- Vol. 60 (4) , 305-311
[Dosimetric comparison of different techniques for external beam accelerated partial breast irradiation].
The aim of this article is to evaluate and compare four different radiotherapy techniques of accelerated partial breast irradiation (APBI) considering planning quality, dosimetric and practical aspects. The investigated techniques are three dimensional conformal radiotherapy (3D-CRT), "step and shoot" (SS) and "sliding window" (SW) intensity-modulated radiotherapy, intensity-modulated arc therapy (RA). CT scans of 10 patients previously treated with APBI were selected for the study. Surgical clips were placed on the borders of the tumour bed during breast conserving surgery. Target volume (PTV) was defined as enlarged CTV, which was created from the tumour bed through volume expansion using individual margins. Planning objectives were set up according to the international recommendations. Non-coplanar fields were used only for the 3D-CRT plans. For each plan homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. There was no significant difference in the coverage of the target volume by the prescribed dose between the techniques. SW plans were significantly more homogeneous (HI=0.033) than the 3D-CRT (HI=0.057) and the RA (HI=0.073) plans. The homogeneity of the SS technique (HI=0.053) did not differ significantly compared to others. The conformity of the 3D-CRT technique was significantly worse (CN=0.62) than that of SS (CN=0.85), SW (CN=0.85) and RA (CN=0.86) plans. There was a significant difference between RA (29.4%) and 3D-CRT (44.1%) and SW (35.6%) plans in the V50% of the ipsilateral breast. Mean V10% of the ipsilateral lung in 3D-CRT (10.1%) plans was significantly lower than in SS (34.3%), SW (34.3%) and RA (35.3%) plans. 3D-CRT technique provided the best heart protection. The shortest treatment times were achieved with RA technique. Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all the aspects, we recommend the sliding window IMRT technique for accelerated partial breast irradiation.
- 25 March 2015
- Vol. 59 (2) , 133-8
[Imaging protocols for the management of respiratory motions in the radiotherapy planning for early stage lung cancer patients].
The aim of our work is to present the imaging techniques used at the National Institute of Oncology for taking into consideration the breathing motion at radiation therapy treatment planning. Internationally recommended imaging techniques, such as 4D CT, respiratory gating and ITV (Internal Target Volume) definition were examined. The different imaging techniques were analysed regarding the delivered dose during imaging, the required time to adapt the technique, and the necessary equipment. The differences in size of PTVs (Planning Target Volume) due to diverse volume defining methods were compared in 5 cases. For 4D CT breath monitoring is crucial, which requires special equipment. To decrease the relatively high exposure of 4D CT it is possible to scan only a few predefined breathing phases. The possible positions of the tumour can be well approximated with CT scans taken in the inhale maximum, the exhale maximum and in intermediate phase. The intermediate phase can be exchanged with an ordinary CT image set, and the extreme phase CT images can be ensured by given verbal instructions for the patient. This way special gating equipment is not required. Based on these 3 breathing phases an ITV can be defined. Using this ITV definition method the margin between the CTV (Clinical Target Volume) and the PTV can be reduced by 1 cm. Using this imaging protocol PTV can be reduced by 30%. A further 10% PTV reduction can be achieved with respiratory gating. In the routine clinical practice respiratory motion management with a 3-phase CT-imaging protocol the PTV for early-stage lung cancer can be significantly reduced without the use of 4D CT and/or respiratory gating. For special, high precision treatment techniques 4D CT is recommended.
- 25 March 2015
- Vol. 59 (2) , 133-8
[Imaging protocols for the management of respiratory motions in the radiotherapy planning for early stage lung cancer patients].
The aim of our work is to present the imaging techniques used at the National Institute of Oncology for taking into consideration the breathing motion at radiation therapy treatment planning. Internationally recommended imaging techniques, such as 4D CT, respiratory gating and ITV (Internal Target Volume) definition were examined. The different imaging techniques were analysed regarding the delivered dose during imaging, the required time to adapt the technique, and the necessary equipment. The differences in size of PTVs (Planning Target Volume) due to diverse volume defining methods were compared in 5 cases. For 4D CT breath monitoring is crucial, which requires special equipment. To decrease the relatively high exposure of 4D CT it is possible to scan only a few predefined breathing phases. The possible positions of the tumour can be well approximated with CT scans taken in the inhale maximum, the exhale maximum and in intermediate phase. The intermediate phase can be exchanged with an ordinary CT image set, and the extreme phase CT images can be ensured by given verbal instructions for the patient. This way special gating equipment is not required. Based on these 3 breathing phases an ITV can be defined. Using this ITV definition method the margin between the CTV (Clinical Target Volume) and the PTV can be reduced by 1 cm. Using this imaging protocol PTV can be reduced by 30%. A further 10% PTV reduction can be achieved with respiratory gating. In the routine clinical practice respiratory motion management with a 3-phase CT-imaging protocol the PTV for early-stage lung cancer can be significantly reduced without the use of 4D CT and/or respiratory gating. For special, high precision treatment techniques 4D CT is recommended.
- 18 March 2015
- Vol. 59 (2) , 95-101
[Dosimetry analysis of intensity-modulated and conformal radiation therapy for head and neck tumors].
The aim of the study was to compare different treatment plans - intensity-modulated and conformal - for head and neck cancer patients. Treatment plans were developed for ten head and neck cancer patients by applying four different techniques: two conventional 3D conformal plans (forward treatment planning, with two opposing fields 90o-270o and one asymmetric anterior field, matching in isocenter /Conv/, conformal parotis sparing plans /ConPas/), 3D conformal plans with inverse treatment planning techniques /INVCRT/ and intensity-modulated radiation therapy plans /IMRT/. The plans were made for the same target volumes PTV50 (elective) and PTV66 (boost-16 Gy). The cumulative dose was 66 Gy, and the Philips Pinnacle3 v8.0m TPS was used for treatment planning. The organs at risk (OAR) were as follows: spinal cord, brain stem, left and right parotis and oral cavity. The dose constrains and conditions for optimization were determined for IMRT techniques with 7 fields. During the optimization we applied two different protocols: in one case the plans were made by 40 segments for "step and shoot" IMRT techniques and by 14 segments for INVCRT, which were converted into static fields. The homogeneity (HI) and conformity (COIN) indices were calculated for planning target volumes and the comparisons were assessed on several dosimetric parameters for OARs. The IMRT, INVCRT, Conv and ConPas techniques for PTV50 planning target volume gave the following values for homogeneity index: 0.13, 0.18, 0.22, 0.19, and for conformity index: 0.76, 0.68, 0.13, 0.09. The spinal cord received a maximum of 38 Gy, 42 Gy, 45 Gy and 44 Gy for the PTV66. Mean doses of the oral cavity outside the target volume were 33 Gy, 36 Gy, 30 Gy and 48 Gy. When the 16 Gy boost treatment was applied on one side only, the mean dose for the parotis on the contralateral side was 28 Gy, 31 Gy, 49 Gy and 43 Gy, while 39 Gy, 41 Gy, 59 Gy and 53 Gy on the same side. The objectives of adequate target coverage and sparing of critical structures were fulfilled only with IMRT technique. Although the sparing of the oral cavity was the most effectively provided by the traditional technique - due to the arrangement of the fields - it gave the worst results regarding the parotis and the target volume. The highest dose for the oral cavity was given by the ConPas technique, which can cause serious early and late side effects. By increasing the number of segments for IMRT at a reasonable level, the dose for OARs can be reduced.
- 18 March 2015
- Vol. 59 (2) , 95-101
[Dosimetry analysis of intensity-modulated and conformal radiation therapy for head and neck tumors].
The aim of the study was to compare different treatment plans - intensity-modulated and conformal - for head and neck cancer patients. Treatment plans were developed for ten head and neck cancer patients by applying four different techniques: two conventional 3D conformal plans (forward treatment planning, with two opposing fields 90o-270o and one asymmetric anterior field, matching in isocenter /Conv/, conformal parotis sparing plans /ConPas/), 3D conformal plans with inverse treatment planning techniques /INVCRT/ and intensity-modulated radiation therapy plans /IMRT/. The plans were made for the same target volumes PTV50 (elective) and PTV66 (boost-16 Gy). The cumulative dose was 66 Gy, and the Philips Pinnacle3 v8.0m TPS was used for treatment planning. The organs at risk (OAR) were as follows: spinal cord, brain stem, left and right parotis and oral cavity. The dose constrains and conditions for optimization were determined for IMRT techniques with 7 fields. During the optimization we applied two different protocols: in one case the plans were made by 40 segments for "step and shoot" IMRT techniques and by 14 segments for INVCRT, which were converted into static fields. The homogeneity (HI) and conformity (COIN) indices were calculated for planning target volumes and the comparisons were assessed on several dosimetric parameters for OARs. The IMRT, INVCRT, Conv and ConPas techniques for PTV50 planning target volume gave the following values for homogeneity index: 0.13, 0.18, 0.22, 0.19, and for conformity index: 0.76, 0.68, 0.13, 0.09. The spinal cord received a maximum of 38 Gy, 42 Gy, 45 Gy and 44 Gy for the PTV66. Mean doses of the oral cavity outside the target volume were 33 Gy, 36 Gy, 30 Gy and 48 Gy. When the 16 Gy boost treatment was applied on one side only, the mean dose for the parotis on the contralateral side was 28 Gy, 31 Gy, 49 Gy and 43 Gy, while 39 Gy, 41 Gy, 59 Gy and 53 Gy on the same side. The objectives of adequate target coverage and sparing of critical structures were fulfilled only with IMRT technique. Although the sparing of the oral cavity was the most effectively provided by the traditional technique - due to the arrangement of the fields - it gave the worst results regarding the parotis and the target volume. The highest dose for the oral cavity was given by the ConPas technique, which can cause serious early and late side effects. By increasing the number of segments for IMRT at a reasonable level, the dose for OARs can be reduced.
- 11 March 2015
- Vol. 59 (2) , 148-53
[Intraoperative and post-implant dosimetry in patients treated with permanent prostate implant brachytherapy].
The purpose of our work was to compare intraoperative and four-week post-implant dosimetry for loose and stranded seed implants for permanent prostate implant brachytherapy. In our institute low-dose-rate (LDR) prostate brachytherapy is performed with encapsulated I-125 isotopes (seeds) using transrectal ultrasound guidance and metal needles. The SPOT PRO 3.1 (Elekta, Sweden) system is used for treatment planning. In this study the first 79 patients were treated with loose seed (LS) technique, the consecutive patients were treated with stranded seed (SS) technique. During intraoperative planning the dose constraints were the same for both techniques. All LSs were placed inside the prostate capsule, while with SS a 2 mm margin around the prostate was allowed for seed positioning. The prescribed dose for the prostate was 145 Gy. This study investigated prostate dose coverage in 30-30 randomly selected patients with LS and SS. Four weeks after the implantation native CT and MRI were done and CT/MRI image fusion was performed. The target was contoured on MRI and the plan was prepared on CT data. To assess the treatment plan dose-volume histograms were used. For the target coverage V100, V90, D90, D100, for the dose inhomogeneity V150, V200, and the dose-homogeneity index (DHI), for dose conformality the conformal index (COIN) were calculated. Intraoperative and postimplant plans were compared. The mean V100 values decreased at four-week plan for SS (97% vs. 84%) and for LS (96% vs. 80%) technique, as well. Decrease was observed for all parameters except for the DHI value. The DHI increased for SS (0.38 vs. 0.41) and for LS (0.38 vs. 0.47) technique, as well. The COIN decreased for both techniques at four-week plan (SS: 0.63 vs. 0.57; LS: 0.67 vs. 0.50). All differences were significant except for the DHI value at SS technique. The percentage changes were not significant, except the COIN value. The dose coverage of the target decreased significantly at four-week plans for both techniques. The decrease was larger for LS technique, but the difference between techniques was not significant at this patient number. The dose distribution was more homogenous, but the conformality was worse at four-week plans.
- 11 March 2015
- Vol. 59 (2) , 148-53
[Intraoperative and post-implant dosimetry in patients treated with permanent prostate implant brachytherapy].
The purpose of our work was to compare intraoperative and four-week post-implant dosimetry for loose and stranded seed implants for permanent prostate implant brachytherapy. In our institute low-dose-rate (LDR) prostate brachytherapy is performed with encapsulated I-125 isotopes (seeds) using transrectal ultrasound guidance and metal needles. The SPOT PRO 3.1 (Elekta, Sweden) system is used for treatment planning. In this study the first 79 patients were treated with loose seed (LS) technique, the consecutive patients were treated with stranded seed (SS) technique. During intraoperative planning the dose constraints were the same for both techniques. All LSs were placed inside the prostate capsule, while with SS a 2 mm margin around the prostate was allowed for seed positioning. The prescribed dose for the prostate was 145 Gy. This study investigated prostate dose coverage in 30-30 randomly selected patients with LS and SS. Four weeks after the implantation native CT and MRI were done and CT/MRI image fusion was performed. The target was contoured on MRI and the plan was prepared on CT data. To assess the treatment plan dose-volume histograms were used. For the target coverage V100, V90, D90, D100, for the dose inhomogeneity V150, V200, and the dose-homogeneity index (DHI), for dose conformality the conformal index (COIN) were calculated. Intraoperative and postimplant plans were compared. The mean V100 values decreased at four-week plan for SS (97% vs. 84%) and for LS (96% vs. 80%) technique, as well. Decrease was observed for all parameters except for the DHI value. The DHI increased for SS (0.38 vs. 0.41) and for LS (0.38 vs. 0.47) technique, as well. The COIN decreased for both techniques at four-week plan (SS: 0.63 vs. 0.57; LS: 0.67 vs. 0.50). All differences were significant except for the DHI value at SS technique. The percentage changes were not significant, except the COIN value. The dose coverage of the target decreased significantly at four-week plans for both techniques. The decrease was larger for LS technique, but the difference between techniques was not significant at this patient number. The dose distribution was more homogenous, but the conformality was worse at four-week plans.