TPTanja Proctor

Tanja Proctor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tanja Proctor has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A comparison of methods for enriching network meta‐analyses in the absence of individual patient data

    by Tanja Proctor, Samuel Zimmermann, Svenja Seide, Meinhard Kieser

    During drug development, a biomarker is sometimes identified as separating a patient population into those with more and those with less benefit from evaluated treatments. Consequently, later studies might be targeted, while earlier ones are performed in mixed patient populations. This poses a challenge in evidence synthesis, especially if only aggregated data are available. Starting from this scenario, we investigate three commonly used network meta-analytic estimation methods, the naive estimation approach, the stand-alone analysis, and the network meta-regression. Additionally, we adapt and modify two methods, which are used in evidence synthesis to combine randomized controlled trials with observational studies, the enrichment-through-weighting approach, and the informative prior estimation. We evaluate all five methods in a simulation study with 32 scenarios using bias, root-mean-squared-error, coverage, precision, and power. Additionally, we revisit a clinical data set to exemplify and discuss the application. In the simulation study, none of the methods was observed to be clearly favorable over all investigated scenarios. However, the stand-alone analysis and the naive estimation performed comparably or worse than the other methods in all evaluated performance measures and simulation scenarios and are therefore not recommended. While substantial between-trial heterogeneity is challenging for all estimation approaches, the performance of the network meta-regression, the enriching-through weighting approach and the informative prior approach was dependent on the simulation scenario and the performance measure of interest. Furthermore, as these estimation methods are drawing slightly different assumptions, some of which require the presence of additional information for estimation, we recommend sensitivity-analyses wherever possible.


  • Open Access

    Diagnostic Performance of Pancreatic Cytology with the Papanicolaou Society of Cytopathology System: A Systematic Review, before Shifting into the Upcoming WHO International System

    by Ilias P. Nikas, Tanja Proctor, Svenja Seide, Stylianos S. Chatziioannou, Jordan P. Reynolds, Dimitrios Ntourakis

    The Papanicolaou Society of Cytopathology (PSC) reporting system classifies pancreatobiliary samples into six categories (I–VI), providing guidance for personalized management. As the World Health Organization (WHO) has been preparing an updated reporting system for pancreatobiliary cytopathology, this systematic review aimed to evaluate the risk of malignancy (ROM) of each PSC category, also the sensitivity and specificity of pancreatic FNA cytology using the current PSC system. Five databases were investigated with a predefined search algorithm. Inclusion and exclusion criteria were applied to select the eligible studies for subsequent data extraction. A study quality assessment was also performed. Eight studies were included in the qualitative analysis. The ROM of the PSC categories I, II, III, IV, V, VI were in the ranges of 8–50%, 0–40%, 28–100%, 0–31%, 82–100%, and 97–100%, respectively. Notably, the ROM IVB (“neoplastic—benign”) subcategory showed a 0% ROM. Four of the included studies reported separately the ROMs for the IVO subcategory (“neoplastic—other”; its overall ROM ranged from 0 to 34%) with low (LGA) and high-grade atypia (HGA). ROM for LGA ranged from 4.3 to 19%, whereas ROM for HGA from 64 to 95.2%. When the subcategory IVO with HGA was considered as cytologically positive, together with the categories V and VI, there was a higher sensitivity of pancreatic cytology, at minimal expense of the specificity. Evidence suggests the proposed WHO international system changes—shifting the IVB entities into the “benign/negative for malignancy” category and establishing two new categories, the “pancreatic neoplasm, low-risk/grade” and “pancreatic neoplasm, high-risk/grade”—could stratify pancreatic neoplasms more effectively than the current PSC system.


  • Open Access

    The Paris System for Reporting Urinary Cytology: A Meta-Analysis

    by Ilias P. Nikas, Svenja Seide, Tanja Proctor, Zoi Kleinaki, Maria Kleinaki, Jordan P. Reynolds

    The Paris System (TPS) for Reporting Urinary Cytology is a standardized, evidence-based reporting system, comprising seven diagnostic categories: nondiagnostic, negative for high-grade urothelial carcinoma (NHGUC), atypical urothelial cells (AUC), suspicious for high-grade urothelial carcinoma (SHGUC), HGUC, low-grade urothelial neoplasm (LGUN), and other malignancies. This study aimed to calculate the pooled risk of high-grade malignancy (ROHM) of each category and demonstrate the diagnostic accuracy of urine cytology reported with TPS. Four databases (PubMed, Embase, Scopus, Web of Science) were searched. Specific inclusion and exclusion criteria were applied, while data were extracted and analyzed both qualitatively and quantitatively. The pooled ROHM was 17.70% for the nondiagnostic category (95% CI, 0.0650; 0.3997), 13.04% for the NHGUC (95% CI, 0.0932; 0.1796), 38.65% for the AUC (95% CI, 0.3042; 0.4759), 12.45% for the LGUN (95% CI, 0.0431; 0.3101), 76.89 for the SHGUC (95% CI, 0.7063; 0.8216), and 91.79% for the HGUC and other malignancies (95% CI, 0.8722; 0.9482). A summary ROC curve was created and the Area Under the Curve (AUC) was 0.849, while the pooled sensitivity was 0.669 (95% CI, 0.589; 0.741) and false-positive rate was 0.101 (95% CI, 0.063; 0.158). In addition, the pooled DOR of the included studies was 21.258 (95% CI, 14.336; 31.522). TPS assigns each sample into a diagnostic category linked with a specific ROHM, guiding clinical management.


  • Open Access

    Integrated evaluation of targeted and non‐targeted therapies in a network meta‐analysis

    by Tanja Proctor, Katrin Jensen, Meinhard Kieser

    Individualized therapies for patients with biomarkers are moving more and more into the focus of research interest when developing new treatments. Hereby, the term individualized (or targeted) therapy denotes a treatment specifically developed for biomarker‐positive patients. A network meta‐analysis model for a binary endpoint combining the evidence for a targeted therapy from individual patient data with the evidence for a non‐targeted therapy from aggregate data is presented and investigated. The biomarker status of the patients is either available at patient‐level in individual patient data or at study‐level in aggregate data. Both types of biomarker information have to be included. The evidence synthesis model follows a Bayesian approach and applies a meta‐regression to the studies with aggregate data. In a simulation study, we address three treatment arms, one of them investigating a targeted therapy. The bias and the root‐mean‐square error of the treatment effect estimate for the subgroup of biomarker‐positive patients based on studies with aggregate data are investigated. Thereby, the meta‐regression approach is compared to approaches applying alternative solutions. The regression approach has a surprisingly small bias even in the presence of few studies. By contrast, the root‐mean‐square error is relatively greater. An illustrative example is provided demonstrating implementation of the presented network meta‐analysis model in a clinical setting.


  • Validation of the mobile serious game application Touch Surgery™ for cognitive training and assessment of laparoscopic cholecystectomy

    by Karl-Friedrich Kowalewski, Jonathan D. Hendrie, Mona W. Schmidt, Tanja Proctor, Sai Paul, Carly R. Garrow, Hannes G. Kenngott, Beat P. Müller-Stich, Felix Nickel

    Background Touch Surgery™ (TS) is a serious gaming application for cognitive task simulation and rehearsal of key steps in surgical procedures. The aim was to establish face, content, and construct validity of TS for laparoscopic cholecystectomy (LC). Furthermore, learning curves with TS and a virtual reality (VR) trainer were compared in a randomized trial. Methods The performance of medical students and general surgeons was compared for all three modules of LC in TS to establish construct validity. Questionnaires assessed face and content validity. For analysis of learning curves, students were randomized to train on VR or TS first, and then switched to the other training modality. Performance data were recorded. Results 54 Surgeons and 51 medical students completed the validation study. Surgeons outperformed students with TS: patient preparation (students = 45.0 ± 19.1%; surgeons = 57.3 ± 15.2%; p < 0.001), access and laparoscopy (students = 70.2 ± 10.9%; surgeons = 75.9 ± 9.7%; p = 0.008) and LC (students = 69.8 ± 12.4%; surgeons = 77.7 ± 9.6%; p < 0.001). Both groups agreed that TS was a highly useful and realistic application. 46 students were randomized for learning curve analysis. It took them 2–4 attempts to reach a 100% score with TS. Training with TS first did not improve students’ performance on the VR trainer; however, students who trained with VR first scored significantly higher in module 3 of TS. Conclusion TS is an accepted serious gaming application for learning cognitive aspects of LC with established construct, face, and content validity. There appeared to be a synergy between TS and the VR trainer. Therefore, the two training modalities should accompany one another in a multimodal training approach to laparoscopy.


  • Development and validation of a sensor- and expert model-based training system for laparoscopic surgery: the iSurgeon

    by Karl-Friedrich Kowalewski, Jonathan D. Hendrie, Mona W. Schmidt, Carly R. Garrow, Thomas Bruckner, Tanja Proctor, Sai Paul, Davud Adigüzel, Sebastian Bodenstedt, Andreas Erben, et al.

    Introduction Training and assessment outside of the operating room is crucial for minimally invasive surgery due to steep learning curves. Thus, we have developed and validated the sensor- and expert model-based laparoscopic training system, the iSurgeon. Materials Participants of different experience levels (novice, intermediate, expert) performed four standardized laparoscopic knots. Instruments and surgeons’ joint motions were tracked with an NDI Polaris camera and Microsoft Kinect v1. With frame-by-frame image analysis, the key steps of suturing and knot tying were identified and registered with motion data. Construct validity, concurrent validity, and test–retest reliability were analyzed. The Objective Structured Assessment of Technical Skills (OSATS) was used as the gold standard for concurrent validity. Results The system showed construct validity by discrimination between experience levels by parameters such as time (novice = 442.9 ± 238.5 s; intermediate = 190.1 ± 50.3 s; expert = 115.1 ± 29.1 s; p < 0.001), total path length (novice = 18,817 ± 10318 mm; intermediate = 9995 ± 3286 mm; expert = 7265 ± 2232 mm; p < 0.001), average speed (novice = 42.9 ± 8.3 mm/s; intermediate = 52.7 ± 11.2 mm/s; expert = 63.6 ± 12.9 mm/s; p < 0.001), angular path (novice = 20,573 ± 12,611°; intermediate = 8652 ± 2692°; expert = 5654 ± 1746°; p < 0.001), number of movements (novice = 2197 ± 1405; intermediate = 987 ± 367; expert = 743 ± 238; p < 0.001), number of movements per second (novice = 5.0 ± 1.4; intermediate = 5.2 ± 1.5; expert = 6.6 ± 1.6; p = 0.025), and joint angle range (for different axes and joints all p < 0.001). Concurrent validity of OSATS and iSurgeon parameters was established. Test–retest reliability was given for 7 out of 8 parameters. The key steps “wrapping the thread around the instrument” and “needle positioning” were most difficult to learn. Conclusion Validity and reliability of the self-developed sensor-and expert model-based laparoscopic training system “iSurgeon” were established. Using multiple parameters proved more reliable than single metric parameters. Wrapping of the needle around the thread and needle positioning were identified as difficult key steps for laparoscopic suturing and knot tying. The iSurgeon could generate automated real-time feedback based on expert models which may result in shorter learning curves for laparoscopic tasks. Our next steps will be the implementation and evaluation of full procedural training in an experimental model.


  • Analysing adverse events by time‐to‐event models: the CLEOPATRA study

    by Tanja Proctor, Martin Schumacher

    When analysing primary and secondary endpoints in a clinical trial with patients suffering from a chronic disease, statistical models for time‐to‐event data are commonly used and accepted. This is in contrast to the analysis of data on adverse events where often only a table with observed frequencies and corresponding test statistics is reported. An example is the recently published CLEOPATRA study where a three‐drug regimen is compared with a two‐drug regimen in patients with HER2‐positive first‐line metastatic breast cancer. Here, as described earlier, primary and secondary endpoints (progression‐free and overall survival) are analysed using time‐to‐event models, whereas adverse events are summarized in a simple frequency table, although the duration of study treatment differs substantially. In this paper, we demonstrate the application of time‐to‐event models to first serious adverse events using the data of the CLEOPATRA study. This will cover the broad range between a simple incidence rate approach over survival and competing risks models (with death as a competing event) to multi‐state models. We illustrate all approaches by means of graphical displays highlighting the temporal dynamics and compare the obtained results. For the CLEOPATRA study, the resulting hazard ratios are all in the same order of magnitude. But the use of time‐to‐event models provides valuable and additional information that would potentially be overlooked by only presenting incidence proportions. These models adequately address the temporal dynamics of serious adverse events as well as death of patients. Copyright © 2016 John Wiley & Sons, Ltd.