Mawya A. Khafaji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mawya A. Khafaji has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Abdulrahman Y. AlNajjar
Medical School, King Abdulaziz University Faculty of Medicine, Jeddah, SAU
1 shared publicationFadi Toonsi
From the Department of Radiology (Khafaji, Toonsi), Faculty of Medicine, King Abdulaziz University, from the Department of Radiodiagnostics and Medical Imaging (Albadawi), King Abdulaziz Medical City, from the Department of Radiodiagnostics and Medical Imaging (Shehata), King Faisal Specialist Hospital and Research Centre, Jeddah, and from the Department of Radiodiagnostics and Medical Imaging (Al-Amoudi, Safhi), Prince Sultan Military Medical City, Riyadh, Kingdom of Saudi Arabia
1 shared publication- Lama H. Meriky
Radiology, King Abdulaziz University Hospital, Jeddah, SAU
1 shared publication Mohammed A. Safhi
From the Department of Radiology (Khafaji, Toonsi), Faculty of Medicine, King Abdulaziz University, from the Department of Radiodiagnostics and Medical Imaging (Albadawi), King Abdulaziz Medical City, from the Department of Radiodiagnostics and Medical Imaging (Shehata), King Faisal Specialist Hospital and Research Centre, Jeddah, and from the Department of Radiodiagnostics and Medical Imaging (Al-Amoudi, Safhi), Prince Sultan Military Medical City, Riyadh, Kingdom of Saudi Arabia
1 shared publicationRoia H. Albadawi
From the Department of Radiology (Khafaji, Toonsi), Faculty of Medicine, King Abdulaziz University, from the Department of Radiodiagnostics and Medical Imaging (Albadawi), King Abdulaziz Medical City, from the Department of Radiodiagnostics and Medical Imaging (Shehata), King Faisal Specialist Hospital and Research Centre, Jeddah, and from the Department of Radiodiagnostics and Medical Imaging (Al-Amoudi, Safhi), Prince Sultan Military Medical City, Riyadh, Kingdom of Saudi Arabia
1 shared publicationSalah S. Shehata
From the Department of Radiology (Khafaji, Toonsi), Faculty of Medicine, King Abdulaziz University, from the Department of Radiodiagnostics and Medical Imaging (Albadawi), King Abdulaziz Medical City, from the Department of Radiodiagnostics and Medical Imaging (Shehata), King Faisal Specialist Hospital and Research Centre, Jeddah, and from the Department of Radiodiagnostics and Medical Imaging (Al-Amoudi, Safhi), Prince Sultan Military Medical City, Riyadh, Kingdom of Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 10 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33588
Assessing Radiation Dosage in Pediatric Head and Neck Computed Tomography Examinations During COVID-19 in a Tertiary Hospital in Saudi Arabia, Jeddah
This study aimed to assess the practice of imaging and optimization of the radiation dose in pediatric head and neck computed tomography (CT) examinations during the coronavirus disease of 2019 (COVID-19) period. This study is based on a retrospective analysis of pediatric head CT records, conducted in the Radiology Department of the King Abdulaziz University Hospital in Jeddah, Saudi Arabia. We examined the data of all pediatric patients between 0 and 14 years of age who underwent head CT scans between March and September in both 2019 (before the COVID-19 pandemic) and 2020 (during the COVID-19 pandemic). In total, we analyzed 1005 scans; 531 (52.8%) were performed before and 474 (47.2%) during COVID-19. The dose parameters were similar; however, the exposure time was significantly lower during COVID-19 (5432 ms vs. 5811 before; p < 0.001). In contrast, the mean total CTDIvol and dose-length product (DLP) were slightly higher during COVID-19 than those before (23.34 mGy vs. 22.04 mGy (p-value=0.565) and 577.36 mGy*cm vs. 518.93 mGy*cm (p-value=0.193) respectively). These changes could be attributed to the desire to limit the contact between technicians and patients. The limitation of contact with the patient allows the technicians to be independent during the scan, possibly accounting for this slight decrease.
- 10 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33588
Open AccessAssessing Radiation Dosage in Pediatric Head and Neck Computed Tomography Examinations During COVID-19 in a Tertiary Hospital in Saudi Arabia, Jeddah
This study aimed to assess the practice of imaging and optimization of the radiation dose in pediatric head and neck computed tomography (CT) examinations during the coronavirus disease of 2019 (COVID-19) period. This study is based on a retrospective analysis of pediatric head CT records, conducted in the Radiology Department of the King Abdulaziz University Hospital in Jeddah, Saudi Arabia. We examined the data of all pediatric patients between 0 and 14 years of age who underwent head CT scans between March and September in both 2019 (before the COVID-19 pandemic) and 2020 (during the COVID-19 pandemic). In total, we analyzed 1005 scans; 531 (52.8%) were performed before and 474 (47.2%) during COVID-19. The dose parameters were similar; however, the exposure time was significantly lower during COVID-19 (5432 ms vs. 5811 before; p < 0.001). In contrast, the mean total CTDIvol and dose-length product (DLP) were slightly higher during COVID-19 than those before (23.34 mGy vs. 22.04 mGy (p-value=0.565) and 577.36 mGy*cm vs. 518.93 mGy*cm (p-value=0.193) respectively). These changes could be attributed to the desire to limit the contact between technicians and patients. The limitation of contact with the patient allows the technicians to be independent during the scan, possibly accounting for this slight decrease.
- Open Access
- 11 January 2022
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 43 (1) , 53-60
Artificial intelligence in radiology
Objectives: To assess the knowledge and perception of artificial intelligence (AI) among radiology residents across Saudi Arabia and assess their interest in learning about AI. Methods: An observational cross-sectional study carried out among radiology residents enrolled in the Saudi Board of Radiology, Saudi Arabia. An anonymized, self-administered questionnaire was distributed in April 2020 and responses were collected until July 2020. Results: A total of 154 residents filled the questionnaire. The top 3 aspects of AI participants wanted to learn were: clinical use of AI applications, advantages and limitations of AI applications, and technical methods. Approximately 43.5% of participants did not expect AI to affect job positions, while 42% anticipated that job positions will decrease. Approximately 53% expected a reduction in reporting workload, while 28% expected an increase in workload. Conclusion: Currently, the exposure of radiologists to the use of AI is inadequate. It is imperative that AI is introduced to radiology trainees and that radiologists stay updated with advances in AI to be more knowledgeable on how to benefit from it.
- 11 January 2022
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 43 (1) , 53-60
Open AccessArtificial intelligence in radiology
Objectives: To assess the knowledge and perception of artificial intelligence (AI) among radiology residents across Saudi Arabia and assess their interest in learning about AI. Methods: An observational cross-sectional study carried out among radiology residents enrolled in the Saudi Board of Radiology, Saudi Arabia. An anonymized, self-administered questionnaire was distributed in April 2020 and responses were collected until July 2020. Results: A total of 154 residents filled the questionnaire. The top 3 aspects of AI participants wanted to learn were: clinical use of AI applications, advantages and limitations of AI applications, and technical methods. Approximately 43.5% of participants did not expect AI to affect job positions, while 42% anticipated that job positions will decrease. Approximately 53% expected a reduction in reporting workload, while 28% expected an increase in workload. Conclusion: Currently, the exposure of radiologists to the use of AI is inadequate. It is imperative that AI is introduced to radiology trainees and that radiologists stay updated with advances in AI to be more knowledgeable on how to benefit from it.
- 1 August 2014
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 35 (8) , 879-881
Direct digital radiograph. Technicians role in obtaining good images
OBJECTIVES: To determine the rejected rate of direct digital radiography (DRs) in our hospital, benchmark it with other institutes, and explore the causes of rejection. METHODS: Data were collected between June 2012 and May 2013 at King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. The rejected analysis was registered in the system, which is a built in software. Reasons for rejection could not be deleted, and no further imaging is allowed for the same patient without reporting the reason for rejection. Reasons for rejection are predefined by the machine. RESULTS: Of 89,797 images that were acquired, 13,371 were rejected, with a rejection rate of 15%. Positioning errors were the main reason for rejection, followed by artifact 28.5%, and motion 17.1%. As for body parts pelvis, abdomen, spine, and knee were recorded as rejected with higher rates than the average. CONCLUSION: This study has shown a number of unnecessary repeated imaging of patients. In addition, reject analysis in DR is proven to be an indicator for quality in imaging, the reasons of rejection that have high percentage for occurrence should be given more focus during patients scan.
- 1 August 2014
- Published by Armed Forces Medical Services in Saudi Medical Journal
- Vol. 35 (8) , 879-881
Direct digital radiograph. Technicians role in obtaining good images
OBJECTIVES: To determine the rejected rate of direct digital radiography (DRs) in our hospital, benchmark it with other institutes, and explore the causes of rejection. METHODS: Data were collected between June 2012 and May 2013 at King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. The rejected analysis was registered in the system, which is a built in software. Reasons for rejection could not be deleted, and no further imaging is allowed for the same patient without reporting the reason for rejection. Reasons for rejection are predefined by the machine. RESULTS: Of 89,797 images that were acquired, 13,371 were rejected, with a rejection rate of 15%. Positioning errors were the main reason for rejection, followed by artifact 28.5%, and motion 17.1%. As for body parts pelvis, abdomen, spine, and knee were recorded as rejected with higher rates than the average. CONCLUSION: This study has shown a number of unnecessary repeated imaging of patients. In addition, reject analysis in DR is proven to be an indicator for quality in imaging, the reasons of rejection that have high percentage for occurrence should be given more focus during patients scan.